| OID symbolic | OID numeric | Type | Access | Description |
| gx2Rfa1000AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.22.2.1 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| gx2Rfa1000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.22.2 | | not-accessible | This table contains gx2Rfa1000 specific parameters with
nominal and current values. |
| gx2Rfa1000Descriptor | 1.3.6.1.4.1.1166.6.1.2.22.1 | | | |
| gx2Rfa1000DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.22.3.2 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| gx2Rfa1000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.22.3 | | not-accessible | This table contains gx2Rfa1000 specific parameters with
nominal and current values. |
| gx2Rfa1000FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.22.5.4 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| gx2Rfa1000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.22.5 | | not-accessible | This table contains gx2Rfa1000 specific parameters with
nominal and current values. |
| INT gx2Rfa1000HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.22.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds. |
| gx2Rfa1000HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.22.6.5 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| INT gx2Rfa1000HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.22.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| gx2Rfa1000HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.22.6 | | not-accessible | This table contains gx2Rfa1000 specific parameters with
nominal and current values. |
| INT gx2Rfa1000HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.22.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| gx2Rfa1000StatusEntry | 1.3.6.1.4.1.1166.6.1.2.22.4.3 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| gx2Rfa1000StatusTable | 1.3.6.1.4.1.1166.6.1.2.22.4 | | not-accessible | This table contains gx2Rfa1000 specific parameters with
nominal and current values. |
| INT rfaalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of
the 12v Current Analog parameter. |
| INT rfaalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of
the Fan Current Analog parameter. |
| INT rfaalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of
the Module Temperature Analog parameter. |
| INT rfabank0CRC | 1.3.6.1.4.1.1166.6.1.2.22.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rfabank1CRC | 1.3.6.1.4.1.1166.6.1.2.22.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rfabootControlByte | 1.3.6.1.4.1.1166.6.1.2.22.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware
is currently being boot from. |
| INT rfabootStatusByte | 1.3.6.1.4.1.1166.6.1.2.22.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rfacalculateCRC | 1.3.6.1.4.1.1166.6.1.2.22.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| FLO rfacurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.30 | Float | read-only | The value of this object provides the Current value
of the 12 Volt Current Analog parameter. |
| FLO rfacurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.19 | Float | read-only | The value of this object provides the Current value
of the Fan Current Analog parameter. |
| FLO rfacurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.8 | Float | read-only | The value of this object provides the Current value
of the Module Temperature Analog parameter. |
| STR rfaenumAttnSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0. |
| STR rfaenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.22.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| STR rfaenumSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 0. |
| INT rfafactoryCRC | 1.3.6.1.4.1.1166.6.1.2.22.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rfaflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.22.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been
programmed on side A. |
| INT rfaflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.22.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been
programmed on side B. |
| STR rfafwRev0 | 1.3.6.1.4.1.1166.6.1.2.22.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR rfafwRev1 | 1.3.6.1.4.1.1166.6.1.2.22.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
| INT rfagx2Rfa1000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.22.2.1.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| INT rfagx2Rfa1000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.22.3.2.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| INT rfagx2Rfa1000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.22.5.4.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| INT rfagx2Rfa1000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.22.4.3.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| INT rfahourMeter | 1.3.6.1.4.1.1166.6.1.2.22.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| STR rfalabel12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.24 | DisplayString | read-only | The value of this object provides the label of the
12v Current Analog parameter. |
| STR rfalabelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.11 | DisplayString | read-only | The value of this object provides the label of the
Alarm Data CRC Status parameter. |
| STR rfalabelAttnCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.17 | DisplayString | read-only | The value of this object provides the label of the
Factor Cal Setting CRC Status parameter. |
| STR rfalabelAttnSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.6 | DisplayString | read-only | The value of this object provides the label of the
RX1000's AttnSetting Digital parameter. |
| STR rfalabelBoot | 1.3.6.1.4.1.1166.6.1.2.22.4.3.2 | DisplayString | read-only | The value of this object provides the label of the
Boot Status Status parameter. |
| STR rfalabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.8 | DisplayString | read-only | The value of this object provides the label of the
Factory Data CRC Status parameter. |
| STR rfalabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.22.3.2.10 | DisplayString | read-only | The value of this object provides the label of the
Factory Default Reset Digital parameter. |
| STR rfalabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.13 | DisplayString | read-only | The value of this object provides the label of the
Fan Current Analog parameter. |
| STR rfalabelFlash | 1.3.6.1.4.1.1166.6.1.2.22.4.3.5 | DisplayString | read-only | The value of this object provides the label of the
Flash Status Status parameter. |
| STR rfalabelModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.2 | DisplayString | read-only | The value of this object provides the label of the
Module Temperature Analog parameter. |
| STR rfalabelSlopeCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.14 | DisplayString | read-only | The value of this object provides the label of the
Calibration Data CRC Status parameter. |
| STR rfalabelSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.2 | DisplayString | read-only | The value of this object provides the label of the
RX1000's AttnSetting Digital parameter. |
| FLO rfamajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value
of the 12 Volt Current Analog parameter. |
| FLO rfamajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value
of the Fan Current Analog parameter. |
| FLO rfamajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value
of the Module Temperature Analog parameter. This value is a floating
point number that is represented as an IEEE 32 bit number. |
| FLO rfamajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value
of the 12 Volt Current Analog parameter. |
| FLO rfamajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value
of the Fan Current Analog parameter. |
| FLO rfamajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter. |
| FLO rfamaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.33 | Float | read-only | The value of this object provides the maximum value
of the 12 Volt Current Analog parameter. |
| FLO rfamaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.22 | Float | read-only | The value of this object provides the maximum value
of the Fan Current Analog parameter. |
| FLO rfamaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.11 | Float | read-only | The value of this object provides the maximum value
of the Module Temperature Analog parameter. |
| FLO rfaminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value
of the 12 Volt Current Analog parameter. |
| FLO rfaminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value
of the Fan Current Analog parameter. This object is not
used by this module and always returns invalid float
value of 0xFFFFFFFF . This object is kept here for persistence |
| FLO rfaminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter. |
| FLO rfaminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value
of the 12 Volt Current Analog parameter. |
| FLO rfaminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter. This object is not
used by this module and always returns invalid float
value of 0xFFFFFFFF . This object is kept here for persistence |
| FLO rfaminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter. |
| FLO rfaminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.32 | Float | read-only | The value of this object provides the minimum value
of the 12 Volt Current Analog parameter. |
| FLO rfaminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.21 | Float | read-only | The value of this object provides the minimum value
of the Fan Current Analog parameter. |
| FLO rfaminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.10 | Float | read-only | The value of this object provides the minimum value
of the Module Temperature Analog parameter. |
| INT rfaprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.22.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rfastateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.31 | INTEGER | read-only | The value of this object provides the state
of the 12v Current Analog parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.13 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagAttnCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.19 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateFlagAttnSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.9 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagBoot | 1.3.6.1.4.1.1166.6.1.2.22.4.3.4 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.10 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.22.3.2.13 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.20 | INTEGER | read-only | The value of this object provides the state
of the Fan Current Analog parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagFlash | 1.3.6.1.4.1.1166.6.1.2.22.4.3.7 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.9 | INTEGER | read-only | The value of this object provides the state
of the Module Temperature Analog parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateflagSlopeCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.16 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| INT rfastateFlagSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.5 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (1-hidden
2-read-only, 3-updateable). |
| STR rfauom12Volt | 1.3.6.1.4.1.1166.6.1.2.22.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the
12v Current Analog parameter. The unit of measure for
this parameter is mA |
| STR rfauomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.22.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the
Fan Current Analog parameter. The unit of measure for
this parameter is mA |
| STR rfauomModTemp | 1.3.6.1.4.1.1166.6.1.2.22.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the
Module Temperature Analog parameter. The unit of measure for
this parameter is Degrees C |
| INT rfavalueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.12 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueAttnCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.18 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueAttnSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer
value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 dB.
Where 1 = 0db and 21 = 5db |
| INT rfavalueBoot | 1.3.6.1.4.1.1166.6.1.2.22.4.3.3 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.9 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.22.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter.This parameter
will always read off(1) |
| INT rfavalueFlash | 1.3.6.1.4.1.1166.6.1.2.22.4.3.6 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueSlopeCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.22.4.3.15 | INTEGER | read-only | The value of this object provides the current state of
the parameter (1-ok, 2-undetermined
3-warning, 4-minor, 5-major, 6-critical). |
| INT rfavalueSlopeSetting | 1.3.6.1.4.1.1166.6.1.2.22.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer
value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB.
Where 1 = 1db and 7 = 4db |
| NTF trapRFA1000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.9 | | | This trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC. |
| NTF trapRFA1000AttnCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.12 | | | This trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm. |
| NTF trapRFA1000Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.22.0.6 | | | This trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error. |
| NTF trapRFA1000Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.22.0.7 | | | This trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error. |
| NTF trapRFA1000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.22.0.2 | | | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapRFA1000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.22.0.1 | | | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapRFA1000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.10 | | | This trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC. |
| NTF trapRFA1000FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.4 | | | This trap is issued when the RFA1000 Module's Fan Currrent parameter goes out of range. |
| NTF trapRFA1000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.8 | | | This trap is issued when the RFA1000 Module's boot or flash programming sequence has detected a Flash error. |
| NTF trapRFA1000ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.3 | | | This trap is issued when the RFA1000 Module's Temperature goes out of range. |
| NTF trapRFA1000Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.5 | | | This trap is issued when the RFA1000 Module's positive 12 volt current parameter goes out of range. |
| NTF trapRFA1000ResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.22.0.13 | | | This trap is issued when the RFA1000 resets to factory defaults |
| NTF trapRFA1000SlopeCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.22.0.11 | | | This trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC. |