OMNI-gx2RX1000-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Rx1000 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "3" Jan 20, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Forward Path Receiver Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Rx1000 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx1000 device type. -- These parameters are common across all network elements -- from gx2Rx1000 device type. -- -- The gx2Rx1000 Network Elements subgroup is -- a list of gx2Rx1000 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx1000TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Rx1000 type. -- -- Both groups are mandatory for management of gx2Rx1000 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Rx1000 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx1000 device type. -- These parameters are common across all network elements -- from gx2Rx1000 device type. gx2Rx1000Descriptor OBJECT IDENTIFIER ::= {gx2Rx1000 1} --***************************************************************************** -- gx2Rx1000 Table -- Contains a list of all gx2Rx1000 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx1000TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Rx1000 type. gx2Rx1000AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx1000 specific parameters with nominal and current values." ::= { gx2Rx1000 2 } gx2Rx1000AnalogEntry OBJECT-TYPE SYNTAX Gx2Rx1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { fprgx2Rx1000AnalogTableIndex } ::= { gx2Rx1000AnalogTable 1} --************************************************************************* gx2Rx1000DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx1000 specific parameters with nominal and current values." ::= { gx2Rx1000 3 } gx2Rx1000DigitalEntry OBJECT-TYPE SYNTAX Gx2Rx1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { fprgx2Rx1000DigitalTableIndex } ::= { gx2Rx1000DigitalTable 2} --************************************************************************* gx2Rx1000StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx1000 specific parameters with nominal and current values." ::= { gx2Rx1000 4 } gx2Rx1000StatusEntry OBJECT-TYPE SYNTAX Gx2Rx1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { fprgx2Rx1000StatusTableIndex } ::= { gx2Rx1000StatusTable 3} --************************************************************************* gx2Rx1000FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx1000 specific parameters with nominal and current values." ::= { gx2Rx1000 5 } gx2Rx1000FactoryEntry OBJECT-TYPE SYNTAX Gx2Rx1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { fprgx2Rx1000FactoryTableIndex } ::= { gx2Rx1000FactoryTable 4} --*********************************************************************** gx2Rx1000HoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx1000HoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx1000 specific parameters with nominal and current values." ::= { gx2Rx1000 6 } gx2Rx1000HoldTimeEntry OBJECT-TYPE SYNTAX Gx2Rx1000HoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx1000HoldTimeTableIndex, gx2Rx1000HoldTimeSpecIndex } ::= { gx2Rx1000HoldTimeTable 5} --*********************************************************************** Gx2Rx1000AnalogEntry ::= SEQUENCE { fprgx2Rx1000AnalogTableIndex INTEGER, -- Analog Parameters fprlabelOptPower DisplayString (SIZE (0..80)), fpruomOptPower DisplayString (SIZE (0..80)), fprmajorHighOptPower Float, fprmajorLowOptPower Float, fprminorHighOptPower Float, fprminorLowOptPower Float, fprcurrentValueOptPower Float, fprstateFlagOptPower INTEGER, fprminValueOptPower Float, fprmaxValueOptPower Float, fpralarmStateOptPower INTEGER, fprlabelModTemp DisplayString (SIZE (0..80)), fpruomModTemp DisplayString (SIZE (0..80)), fprmajorHighModTemp Float, fprmajorLowModTemp Float, fprminorHighModTemp Float, fprminorLowModTemp Float, fprcurrentValueModTemp Float, fprstateFlagModTemp INTEGER, fprminValueModTemp Float, fprmaxValueModTemp Float, fpralarmStateModTemp INTEGER, fprlabelSinkTemp DisplayString (SIZE (0..80)), fpruomSinkTemp DisplayString (SIZE (0..80)), fprmajorHighSinkTemp Float, fprmajorLowSinkTemp Float, fprminorHighSinkTemp Float, fprminorLowSinkTemp Float, fprcurrentValueSinkTemp Float, fprstateFlagSinkTemp INTEGER, fprminValueSinkTemp Float, fprmaxValueSinkTemp Float, fpralarmStateSinkTemp INTEGER, fprlabelFanCurrent DisplayString (SIZE (0..80)), fpruomFanCurrent DisplayString (SIZE (0..80)), fprmajorHighFanCurrent Float, fprmajorLowFanCurrent Float, fprminorHighFanCurrent Float, fprminorLowFanCurrent Float, fprcurrentValueFanCurrent Float, fprstateFlagFanCurrent INTEGER, fprminValueFanCurrent Float, fprmaxValueFanCurrent Float, fpralarmStateFanCurrent INTEGER, fprlabel12Volt DisplayString (SIZE (0..80)), fpruom12Volt DisplayString (SIZE (0..80)), fprmajorHigh12Volt Float, fprmajorLow12Volt Float, fprminorHigh12Volt Float, fprminorLow12Volt Float, fprcurrentValue12Volt Float, fprstateFlag12Volt INTEGER, fprminValue12Volt Float, fprmaxValue12Volt Float, fpralarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2Rx1000DigitalEntry ::= SEQUENCE { fprgx2Rx1000DigitalTableIndex INTEGER, fprlabelSlopeSetting DisplayString (SIZE (0..80)), fprvalueSlopeSetting INTEGER, fprenumSlopeSetting DisplayString (SIZE (0..80)), fprstateFlagSlopeSetting INTEGER, fprlabelAttnSetting DisplayString (SIZE (0..80)), fprvalueAttnSetting INTEGER, fprenumAttnSetting DisplayString (SIZE (0..80)), fprstateFlagAttnSetting INTEGER, fprlabelWavelength DisplayString (SIZE (0..80)), fprvalueWavelength INTEGER, fprenumWavelength DisplayString (SIZE (0..80)), fprstateFlagWavelength INTEGER, fprlabelFactoryDefault DisplayString (SIZE (0..80)), fprvalueFactoryDefault INTEGER, fprenumFactoryDefault DisplayString (SIZE (0..80)), fprstateFlagFactoryDefault INTEGER, fprlabelSwModeThreshold DisplayString (SIZE (0..80)), fprvalueSwModeThreshold INTEGER, fprenumSwModeThreshold DisplayString (SIZE (0..80)), fprstateFlagSwModeThreshold INTEGER, fprlabelSwModeSetting DisplayString (SIZE (0..80)), fprvalueSwModeSetting INTEGER, fprenumSwModeSetting DisplayString (SIZE (0..80)), fprstateFlagSwModeSetting INTEGER } -- **************** Status Parameters ************************************ Gx2Rx1000StatusEntry ::= SEQUENCE { fprgx2Rx1000StatusTableIndex INTEGER, fprlabelBoot DisplayString (SIZE (0..80)), fprvalueBoot INTEGER, fprstateflagBoot INTEGER, fprlabelFlash DisplayString (SIZE (0..80)), fprvalueFlash INTEGER, fprstateflagFlash INTEGER, fprlabelFactoryDataCRC DisplayString (SIZE (0..80)), fprvalueFactoryDataCRC INTEGER, fprstateflagFactoryDataCRC INTEGER, fprlabelAlarmDataCRC DisplayString (SIZE (0..80)), fprvalueAlarmDataCRC INTEGER, fprstateflagAlarmDataCRC INTEGER, fprlabelCalibrationDataCRC DisplayString (SIZE (0..80)), fprvalueCalibrationDataCRC INTEGER, fprstateflagCalibrationDataCRC INTEGER, fprlabelFacCalSettingCRC DisplayString (SIZE (0..80)), fprvalueFacCalSettingCRC INTEGER, fprstateflagFacCalSettingCRC INTEGER, fprlabelInputSig DisplayString (SIZE (0..80)), fprvalueInputSig INTEGER, fprstateflagInputSig INTEGER } -- **************** Factory Parameters ************************************* Gx2Rx1000FactoryEntry ::= SEQUENCE { fprgx2Rx1000FactoryTableIndex INTEGER, fprbootControlByte INTEGER, fprbootStatusByte INTEGER, fprbank0CRC INTEGER, fprbank1CRC INTEGER, fprprgEEPROMByte INTEGER, fprfactoryCRC INTEGER, fprcalculateCRC INTEGER, fprhourMeter INTEGER, fprflashPrgCntA INTEGER, fprflashPrgCntB INTEGER, fprfwRev0 DisplayString (SIZE (0..80)), fprfwRev1 DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* Gx2Rx1000HoldTimeEntry ::= SEQUENCE { gx2Rx1000HoldTimeTableIndex INTEGER, gx2Rx1000HoldTimeSpecIndex INTEGER, gx2Rx1000HoldTimeData INTEGER } -- ************** Analog Parameters **************************** fprgx2Rx1000AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx1000AnalogEntry 1} -- New Parameter fprlabelOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx1000AnalogEntry 2} fpruomOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx1000AnalogEntry 3} fprmajorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 4} fprmajorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 5} fprminorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 6} fprminorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 7} fprcurrentValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 8} fprstateFlagOptPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000AnalogEntry 9} fprminValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 10} fprmaxValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 11} fpralarmStateOptPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx1000AnalogEntry 12} -- New Parameter fprlabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 13} fpruomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 14} fprmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 15} fprmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 16} fprminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 17} fprminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 18} fprcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 19} fprstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000AnalogEntry 20} fprminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 21} fprmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 22} fpralarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 23} -- New Parameter fprlabelSinkTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 24} fpruomSinkTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 25} fprmajorHighSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 26} fprmajorLowSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 27} fprminorHighSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 28} fprminorLowSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 29} fprcurrentValueSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 30} fprstateFlagSinkTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000AnalogEntry 31} fprminValueSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 32} fprmaxValueSinkTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 33} fpralarmStateSinkTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Rx1000AnalogEntry 34} -- New Parameter fprlabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Rx1000AnalogEntry 35} fpruomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2Rx1000AnalogEntry 36} fprmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 37} fprmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 38} fprminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 39} fprminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 40} fprcurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 41} fprstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000AnalogEntry 42} fprminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 43} fprmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 44} fpralarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Rx1000AnalogEntry 45} -- New Parameter fprlabel12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2Rx1000AnalogEntry 46} fpruom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2Rx1000AnalogEntry 47} fprmajorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 48} fprmajorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 49} fprminorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 50} fprminorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 51} fprcurrentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 52} fprstateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000AnalogEntry 53} fprminValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 54} fprmaxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx1000AnalogEntry 55} fpralarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2Rx1000AnalogEntry 56} -- ************************ Digital parameters ********************************** fprgx2Rx1000DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx1000DigitalEntry 1} -- New parameter fprlabelSlopeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RX1000's AttnSetting Digital parameter." ::= { gx2Rx1000DigitalEntry 2} fprenumSlopeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0." ::= { gx2Rx1000DigitalEntry 3} fprvalueSlopeSetting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 6. Each increment represents 1/2 dB of slope from 0 to 3 dB. Where 0 = 0db and 6 = 3db" ::= { gx2Rx1000DigitalEntry 4} fprstateFlagSlopeSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 5} -- New parameter fprlabelAttnSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RX1000's AttnSetting Digital parameter." ::= { gx2Rx1000DigitalEntry 6} fprenumAttnSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0." ::= { gx2Rx1000DigitalEntry 7} fprvalueAttnSetting OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/4 dB of attenuation from 0 to 10 dB. Where 0 = 0db and 40 = 10db" ::= { gx2Rx1000DigitalEntry 8} fprstateFlagAttnSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 9} -- New parameter fprlabelWavelength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RX1000's Wavelength Digital parameter." ::= { gx2Rx1000DigitalEntry 10} fprenumWavelength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0." ::= { gx2Rx1000DigitalEntry 11} fprvalueWavelength OBJECT-TYPE SYNTAX INTEGER { nM1310(1), nM1550(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx1000DigitalEntry 12} fprstateFlagWavelength OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 13} -- New parameter fprlabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx1000DigitalEntry 14} fprenumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx1000DigitalEntry 15} fprvalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx1000DigitalEntry 16} fprstateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 17} -- New parameter fprlabelSwModeThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RX1000's Switch Mode Threshold Digital parameter." ::= { gx2Rx1000DigitalEntry 18} fprenumSwModeThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a comma. The first value has a enumerated value of 0." ::= { gx2Rx1000DigitalEntry 19} fprvalueSwModeThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 0.5 dB increments ranging from -9 to +1 dB. The user can enter a number from 0 to 20, where 0 = -9db and 20= +1db" ::= { gx2Rx1000DigitalEntry 20} fprstateFlagSwModeThreshold OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 21} -- New parameter fprlabelSwModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RX1000's Switch Mode Setting Digital parameter." ::= { gx2Rx1000DigitalEntry 22} fprenumSwModeSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0." ::= { gx2Rx1000DigitalEntry 23} fprvalueSwModeSetting OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx1000DigitalEntry 24} fprstateFlagSwModeSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000DigitalEntry 25} --*********** STATUS ***************** fprgx2Rx1000StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx1000StatusEntry 1} --New Parameter fprlabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Rx1000StatusEntry 2} fprvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 3} fprstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 4} --New Parameter fprlabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Rx1000StatusEntry 5} fprvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 6} fprstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 7} --New Parameter fprlabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Rx1000StatusEntry 8} fprvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 9} fprstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 10} --New Parameter fprlabelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data CRC Status parameter." ::= { gx2Rx1000StatusEntry 11} fprvalueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 12} fprstateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 13} --New Parameter fprlabelCalibrationDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC Status parameter." ::= { gx2Rx1000StatusEntry 14} fprvalueCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 15} fprstateflagCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 16} --New Parameter fprlabelFacCalSettingCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factor Cal Setting CRC Status parameter." ::= { gx2Rx1000StatusEntry 17} fprvalueFacCalSettingCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 18} fprstateflagFacCalSettingCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 19} --New Parameter fprlabelInputSig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Input Sig Status parameter." ::= { gx2Rx1000StatusEntry 20} fprvalueInputSig OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx1000StatusEntry 21} fprstateflagInputSig OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx1000StatusEntry 22} -- ************ FACTORY DATA **************** fprgx2Rx1000FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx1000FactoryEntry 1} fprbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Rx1000FactoryEntry 2} fprbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2Rx1000FactoryEntry 3} fprbank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2Rx1000FactoryEntry 4} fprbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2Rx1000FactoryEntry 5} fprprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Rx1000FactoryEntry 6} fprfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Rx1000FactoryEntry 7} fprcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), calibration(2), alarmdata(3), calSetting(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2Rx1000FactoryEntry 8} fprhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Rx1000FactoryEntry 9} fprflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side A." ::= { gx2Rx1000FactoryEntry 10} fprflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side B." ::= { gx2Rx1000FactoryEntry 11} fprfwRev0 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 0." ::= { gx2Rx1000FactoryEntry 12} fprfwRev1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 1." ::= { gx2Rx1000FactoryEntry 13} -- ************ Hold Time DATA **************** gx2Rx1000HoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2Rx1000HoldTimeEntry 1} gx2Rx1000HoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2Rx1000HoldTimeEntry 2} gx2Rx1000HoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2Rx1000HoldTimeEntry 3} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- RX1000 Module traps -- ************************************************************************** trapRX1000ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapRX1000ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapRX1000OpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the input Optical Power parameter goes out of range." ::= 3 trapRX1000ModuleTemperatureAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's Temperature goes out of range." ::= 4 trapRX1000HeatSinkTemperatureAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Heat Sink Temperature goes out of range." ::= 5 trapRX1000FanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's Fan Currrent parameter goes out of range." ::= 6 trapRX1000Plus12CurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's positive 12 volt current parameter goes out of range." ::= 7 trapRX1000OpticalSwitchAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Redundancy signal indicates a low input signal." ::= 8 trapRX1000Boot0Alarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's Bank 0 Boot sequence has detected an error." ::= 9 trapRX1000Boot1Alarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's Bank 1 Boot sequence has detected an error." ::= 10 trapRX1000FlashAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module's boot or flash programming sequence has detected a Flash error." ::= 11 trapRX1000AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module detects an error calculating the alarm limit CRC." ::= 12 trapRX1000FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module detects an error calculating the Factory data CRC." ::= 13 trapRX1000CalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module detects an error calculating the Calibration data CRC." ::= 14 trapRX1000ResetFacDefault TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 resets to factory defaults" ::= 15 trapRX1000FacCalSettingCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RX1000 Module detects factory calibration setting CRC alarm." ::= 16 END