OMNI-gx2RX1000-MIB :: fpralarmStateSinkTemp

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2RX1000-MIB › fpralarmStateSinkTemp

fpralarmStateSinkTemp

Module: OMNI-gx2RX1000-MIB

OID (symbolic): OMNI-gx2RX1000-MIB::fpralarmStateSinkTemp

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.9.2.1.34

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The value of this object provides the curent alarm state of the Module Temperature Analog parameter.

What is fpralarmStateSinkTemp?

Read-only INTEGER giving the current alarm condition for the heatsink temperature: noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), or informational(6). This is the single field a monitoring system should watch to know whether the the heatsink temperature channel needs attention right now. (Note: the source MIB's DESCRIPTION text for this object was copy-pasted from the ModTemp sibling and literally says "Module Temperature" instead of referring to this Sink Temperature parameter; this reading is based on the object's own name and its distinct position in the table.)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.9.2.1.34
snmpwalk -v2c -c public <target> OMNI-gx2RX1000-MIB::fpralarmStateSinkTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.9.2.1.34.1
snmpget -v2c -c public <target> OMNI-gx2RX1000-MIB::fpralarmStateSinkTemp.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2RX1000-MIB::fpralarmStateSinkTemp OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.9gx2Rx1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.9.2gx2Rx1000AnalogTableOMNI-gx2RX1000-MIB
1.3.6.1.4.1.1166.6.1.2.9.2.1gx2Rx1000AnalogEntryOMNI-gx2RX1000-MIB
1.3.6.1.4.1.1166.6.1.2.9.2.1.34fpralarmStateSinkTempOMNI-gx2RX1000-MIB