All MIBs › OMNI-gx2RX1000-MIB › gx2Rx1000HoldTimeData
gx2Rx1000HoldTimeData
Module: OMNI-gx2RX1000-MIB
OID (symbolic): OMNI-gx2RX1000-MIB::gx2Rx1000HoldTimeData
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.9.6.5.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
What is gx2Rx1000HoldTimeData?
Read-write 32-bit INTEGER encoding the alarm hold/debounce timer (0-1300 seconds) used to suppress noisy alarm flapping on the analog sensor objects; an admin raises this if an alarm is toggling on transient noise instead of a real fault. The source DESCRIPTION notes byte-level layout details but leaves the per-index alarm mapping as unfilled placeholders ("Index 1 = xxx"), so exact per-index semantics are not fully documented in the source MIB.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.9.6.5.3 snmpwalk -v2c -c public <target> OMNI-gx2RX1000-MIB::gx2Rx1000HoldTimeData
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.9.6.5.3.1 snmpget -v2c -c public <target> OMNI-gx2RX1000-MIB::gx2Rx1000HoldTimeData.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.9.6.5.3.1 i <value>
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2RX1000-MIB::gx2Rx1000HoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX1000 1000 MHz optical receiver card) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.9 | gx2Rx1000 | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.9.6 | gx2Rx1000HoldTimeTable | OMNI-gx2RX1000-MIB |
| 1.3.6.1.4.1.1166.6.1.2.9.6.5 | gx2Rx1000HoldTimeEntry | OMNI-gx2RX1000-MIB |
| 1.3.6.1.4.1.1166.6.1.2.9.6.5.3 | gx2Rx1000HoldTimeData | OMNI-gx2RX1000-MIB |