Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Lm870C-MIB?
OMNI-gx2Lm870C-MIB is a vendor MIB for the Cisco/Scientific-Atlanta GX2 LM870C, an 870 MHz laser transmitter module used in HFC optical nodes to convert RF signals to optical for fiber transport. It exposes module-specific configuration and status objects such as laser bias current, optical output power, and operating temperature relevant to the laser transmitter's health. Its principal use is monitoring the hardware status of the laser module, since laser bias drift, low optical output, or overtemperature readings are classic early indicators of laser aging or impending failure in optical nodes. It shares the common OMNI-gx2 chassis/module management framework with other GX2 modules such as the RF amplifier and RF switch MIBs. It is typically deployed in HFC optical node sites where laser transmitters feed fiber links back to the headend. Engineers can download the OMNI-gx2Lm870C-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Lm870C-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM870C 870 MHz laser transmitter module)
Monitoring Examples
No sample object names were provided for this module; in practice an operator would poll the laser module's status objects for bias current, optical output power, and module temperature within the GX2 chassis tree. A steadily declining optical output power or rising bias current reading would reveal an aging or failing LM870C laser transmitter before a complete link failure occurs. As with sibling OMNI-gx2 MIBs, it is typically read alongside the chassis-level module inventory objects.
What Can Be Monitored
- laser bias current
- optical output power
- module temperature
- module operational status
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Lm870C | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapLM870CConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.10.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLMCConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.10.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapLMCFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.3 | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMC12vAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.4 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMCModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.5 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapLMCRFPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.6 | This trap is issued when the Laser Modules RF Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMCOPTPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.7 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMCLaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.8 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMCTECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapLMCFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.10 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapLMCBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.11 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapLMCAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.12 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapLMCModSetDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.13 | This trap is issued when the Module Settings CRC is incorrect. | ||
| NTF trapLMCFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.14 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapLMCResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.15 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapLMCOPCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.16 | This trap is issued when the Optical Calibration Data CRC is incorrect. | ||
| NTF trapLMCRFCalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.17 | This trap is issued when the RF Calibration Data CRC is incorrect. | ||
| NTF trapLMCRFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.18 | This trap is issued when the RF Overload alarm occurs. | ||
| NTF trapLMCOMIoffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.10.0.19 | This trap is issued when an OMI Offset alarm occurs. | ||
| gx2Lm870CDescriptor | 1.3.6.1.4.1.1166.6.1.2.10.1 | |||
| gx2lm870CAnalogTable | 1.3.6.1.4.1.1166.6.1.2.10.2 | not-accessible | This table contains gx2Lm870C specific parameters with nominal and current values. | |
| gx2lm870CAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.10.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Lm870CAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm870ClabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR lm870CuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO lm870CmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.8 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.10 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.11 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR lm870Clabel12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.13 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR lm870Cuom12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO lm870CmajorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.19 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.20 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.21 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.22 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.10.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| STR lm870ClabelModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR lm870CuomModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO lm870CmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.30 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.32 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.33 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.10.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR lm870ClabelOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.35 | DisplayString | read-only | The value of this object provides the label of the OMI Offset Analog parameter. |
| STR lm870CuomOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the OMI Offset Analog parameter. |
| FLO lm870CmajorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.41 | Float | read-only | The value of this object provides the Current value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.42 | INTEGER | read-only | The value of this object provides the state of the OMI Offset Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.43 | Float | read-only | The value of this object provides the minimum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.44 | Float | read-only | The value of this object provides the maximum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateOmiOffset | 1.3.6.1.4.1.1166.6.1.2.10.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the OMI Offset Analog parameter. |
| STR lm870ClabelOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR lm870CuomOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter.. |
| FLO lm870CmajorHighOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.52 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.54 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.55 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateOPTPower | 1.3.6.1.4.1.1166.6.1.2.10.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR lm870ClabelLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR lm870CuomLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO lm870CmajorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.63 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.65 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.66 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.10.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR lm870ClabelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.68 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR lm870CuomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO lm870CmajorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.74 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.75 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.76 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.77 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.10.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR lm870ClabelOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.79 | DisplayString | read-only | The value of this object provides the label of the OMI Offset Alarm Setpoint Analog parameter. |
| STR lm870CuomOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the OMI Offset Alarm Setpoint Analog parameter.. |
| FLO lm870CmajorHighOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmajorLowOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorHighOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CminorLowOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CcurrentValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.85 | Float | read-only | The value of this object provides the Current value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CstateFlagOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.86 | INTEGER | read-only | The value of this object provides the state of the OMI Offset Alarm Setpoint Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO lm870CminValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.87 | Float | read-only | The value of this object provides the minimum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO lm870CmaxValueOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.88 | Float | read-only | The value of this object provides the maximum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT lm870CalarmStateOmiAlarmSetpoint | 1.3.6.1.4.1.1166.6.1.2.10.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the OMI Offset Alarm Setpoint Analog parameter. |
| gx2lm870CDigitalTable | 1.3.6.1.4.1.1166.6.1.2.10.3 | not-accessible | This table contains gx2Lm870C specific parameters with discrete values. | |
| gx2lm870CDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.10.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2Lm870CDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm870ClabelOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.2 | DisplayString | read-only | The value of this object provides the label of the OMI Offset Alarm mode Digital parameter. |
| STR lm870CenumOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the OMI Offset Alarm modeDigital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm870CvalueOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. Note that the value to be read will always be 1 or 2 because the set value (3) is always changed to the on value (2) by the firmware |
| INT lm870CstateFlagOMIOffsetAlarms | 1.3.6.1.4.1.1166.6.1.2.10.3.2.5 | INTEGER | read-only | The value of this object provides the state of the OMI Offset Alarm mode Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Reset to Factory Default Control Digital parameter. |
| STR lm870CenumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Reste to Factory Default Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm870CvalueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT lm870CstateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.10.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.10 | DisplayString | read-only | The value of this object provides the label of the OMI Setpoint Digital parameter. |
| STR lm870CenumOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the OMI Setpoint Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT lm870CvalueOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.12 | INTEGER | read-only | The value of this object is the current value of the OMI Setpoint parameter. |
| INT lm870CstateFlagOMISetpoint | 1.3.6.1.4.1.1166.6.1.2.10.3.2.13 | INTEGER | read-only | The value of this object provides the state of the OMI Setpoint Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2lm870CStatusTable | 1.3.6.1.4.1.1166.6.1.2.10.4 | not-accessible | This table contains gx2Lm870C specific parameters with current values. | |
| gx2lm870CStatusEntry | 1.3.6.1.4.1.1166.6.1.2.10.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Lm870CStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR lm870ClabelBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT lm870CvalueBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.3 | INTEGER | read-only | The value of this object provides the current value of the boot status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.10.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the boot status parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT lm870CvalueFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.6 | INTEGER | read-only | The value of this object provides the current value of the Flash Status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.10.4.3.7 | INTEGER | read-only | The value of this object provides the state current of the the Flash Status parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.8 | DisplayString | read-only | The value of this object provides the label for the RF Overload Status parameter. |
| INT lm870CvalueRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.9 | INTEGER | read-only | The value of this object provides the current value of the RF Overload parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagRFOverload | 1.3.6.1.4.1.1166.6.1.2.10.4.3.10 | INTEGER | read-only | The value of this object provides the current state of the RF Overload parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.11 | DisplayString | read-only | The value of this object provides the label for the RF Power Status parameter. |
| INT lm870CvalueRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.12 | INTEGER | read-only | The value of this object provides the current value of the RF Power parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagRFPower | 1.3.6.1.4.1.1166.6.1.2.10.4.3.13 | INTEGER | read-only | The value of this object provides the current state of the RF Power parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT lm870CvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.15 | INTEGER | read-only | The value of this object provides the current value of the Factory Data CRC parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.16 | INTEGER | read-only | The value of this object provides the current state of the the Factory Data CRC parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT lm870CvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.18 | INTEGER | read-only | The value of this object provides the current value of the Alarm Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.10.4.3.19 | INTEGER | read-only | The value of this object provides the current state of the the Alarm Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Module Settings Data Crc parameter. |
| INT lm870CvalueModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.21 | INTEGER | read-only | The value of this object provides the current value of the Module Settings Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagModSetDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.22 | INTEGER | read-only | The value of this object provides the current state of the the Module Settings Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Optical Calibration Data Crc parameter. |
| INT lm870CvalueOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.24 | INTEGER | read-only | The value of this object provides the current value of the Optical Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagOptCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.25 | INTEGER | read-only | The value of this object provides the current state of the the Optical Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR lm870ClabelRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.26 | DisplayString | read-only | The value of this object provides the label of the RF Calibration Data Crc parameter. |
| INT lm870CvalueRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.27 | INTEGER | read-only | The value of this object provides the current value of the RF Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT lm870CstateflagRFCalDataCRC | 1.3.6.1.4.1.1166.6.1.2.10.4.3.28 | INTEGER | read-only | The value of this object provides the current state of the the RF Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2lm870CFactoryTable | 1.3.6.1.4.1.1166.6.1.2.10.5 | not-accessible | This table contains gx2Lm870C specific parameters with stored factory values. | |
| gx2lm870CFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.10.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Lm870CFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.10.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT lm870CbootControlByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT lm870CbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT lm870Cbank1CRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT lm870Cbank2CRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT lm870CprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.10.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT lm870CfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT lm870CcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.10.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT lm870ChourMeter | 1.3.6.1.4.1.1166.6.1.2.10.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT lm870CflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.10.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT lm870CflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.10.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR lm870CflashBankARev | 1.3.6.1.4.1.1166.6.1.2.10.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR lm870CflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.10.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
RFC description
Manages the Cisco/Scientific-Atlanta GX2 LM870C 870 MHz laser module in HFC optical node deployments.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM870C 870 MHz laser transmitter module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.