All MIBs › OMNI-gx2CM-MIB
Category: CATV and HFC
Description: Manages the Cisco/Scientific Atlanta GX2 CM optical node line card status and performance in CATV HFC plants.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2CM-MIB?
OMNI-gx2CM-MIB is a Blonder Tongue (BBN/GX2 HFC headend heritage) proprietary MIB reporting gx2CM (cable-headend combiner module) factory/network/analog/digital/status/AMC/security/diagnostic telemetry. Its tables (factory, network, analog, digital, status, AMC, security, diagnostic, download, each keyed by module index) track per-parameter label/unit/thresholds/current-value for analog measurements like module temperature, alongside a trap-history table. As a hardware-performance MIB it lets an administrator watch a gx2CM module's analog telemetry against threshold bands and review its trap history in an HFC headend. It is deployed on Blonder Tongue (GX2) HFC headend equipment. Engineers can download the OMNI-gx2CM-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2CM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module)
Monitoring Examples
An administrator reviews cmTrapHistoryTable and checks majorHighModTemp thresholds to diagnose a recent alarm on a gx2CM module in an HFC headend.
What Can Be Monitored
- gx2CM module analog telemetry and trap history
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Cm | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapCMConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.3.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapCMConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.3.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapCMModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.3 | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCMEEPROMAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.4 | This trap is issued when the EEPROM detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCMFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.5 | This trap is issued when the Flash device detects an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCMHardwareAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.6 | This trap is issued when the system hardware detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCMInitEEPROMAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.7 | This trap is issued when the there is an EEPROM initializing error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCMBootAlarm | 1.3.6.1.4.1.1166.6.1.2.3.0.8 | This trap is issued when the there is a boot error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| gx2cmDescriptor | 1.3.6.1.4.1.1166.6.1.2.3.1 | |||
| gx2cmFactoryTable | 1.3.6.1.4.1.1166.6.1.2.3.2 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.3.2.1 | not-accessible | This list contains Factory data and the associated parameter descriptions. | |
| INT gx2cmFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT bootControlByte | 1.3.6.1.4.1.1166.6.1.2.3.2.1.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.3.2.1.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT bank0CRC | 1.3.6.1.4.1.1166.6.1.2.3.2.1.4 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT bank1CRC | 1.3.6.1.4.1.1166.6.1.2.3.2.1.5 | INTEGER | read-only | This object provides the CRC code of bank 2. |
| INT prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.3.2.1.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT factoryCRC | 1.3.6.1.4.1.1166.6.1.2.3.2.1.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT calculateCRC | 1.3.6.1.4.1.1166.6.1.2.3.2.1.8 | INTEGER | read-only | This object provides the CRC value of the fimware. |
| INT hourMeter | 1.3.6.1.4.1.1166.6.1.2.3.2.1.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT flashPrgCnt0 | 1.3.6.1.4.1.1166.6.1.2.3.2.1.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT flashPrgCnt1 | 1.3.6.1.4.1.1166.6.1.2.3.2.1.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR flashBank0 | 1.3.6.1.4.1.1166.6.1.2.3.2.1.12 | DisplayString | read-only | This object provides the firmware revision of the firmware in bank 0. |
| STR flashBank1 | 1.3.6.1.4.1.1166.6.1.2.3.2.1.13 | DisplayString | read-only | This object provides the firmware revision of the firmware in bank 1. |
| STR localMacAdd | 1.3.6.1.4.1.1166.6.1.2.3.2.1.14 | DisplayString | read-only | This object provides the local mac address number |
| STR netWorkMacAdd | 1.3.6.1.4.1.1166.6.1.2.3.2.1.15 | DisplayString | read-only | This object provides the network mac address number. |
| gx2cmNetworkTable | 1.3.6.1.4.1.1166.6.1.2.3.3 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmNetworkEntry | 1.3.6.1.4.1.1166.6.1.2.3.3.2 | not-accessible | This list contains Network parameters and the associated parameter descriptions. | |
| INT gx2cmNetworkTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelLocalEthIPAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.2 | DisplayString | read-only | This object provides the label for the Ethernet IP Address field. |
| STR valueLocalEthIPAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.3 | DisplayString | read-write | This object provides the Local Ethernet IP Address for the Control Module. |
| STR labelLocalEthMask | 1.3.6.1.4.1.1166.6.1.2.3.3.2.4 | DisplayString | read-only | This object provides the label for the Local Ethernet Mask field. |
| STR valueLocalEthMask | 1.3.6.1.4.1.1166.6.1.2.3.3.2.5 | DisplayString | read-write | This object provides the Local Ethernet Mask value. |
| STR labelNetworkEthAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.6 | DisplayString | read-only | This object provides the label for the Network Ethernet Address . |
| STR valueNetworkEthAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.7 | DisplayString | read-write | This object provides the value of the Network Ethernet Address. |
| STR labelNetworkEthMask | 1.3.6.1.4.1.1166.6.1.2.3.3.2.8 | DisplayString | read-only | This object provides the label for the Network Mask Address. |
| STR valueNetworkEthMask | 1.3.6.1.4.1.1166.6.1.2.3.3.2.9 | DisplayString | read-write | This object provides the value of the Network Mask Address. |
| STR labelShelfSerialNum | 1.3.6.1.4.1.1166.6.1.2.3.3.2.10 | DisplayString | read-only | This object provides the label for the Shelf Serial Number. |
| STR valueShelfSerialNum | 1.3.6.1.4.1.1166.6.1.2.3.3.2.11 | DisplayString | read-only | This object provides the value for the Shelf Serial Number. |
| STR labelGateWayIPAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.12 | DisplayString | read-only | This object provides the label for the Gateway IP address. |
| STR valueGateWayIPAdd | 1.3.6.1.4.1.1166.6.1.2.3.3.2.13 | DisplayString | read-write | This object provides the value for the IP address for the Gateway. |
| STR labelTrapDestination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.14 | DisplayString | read-only | This object provides the label the trap destination field. |
| STR valueTrapDestination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.15 | DisplayString | read-write | This object provides the address for the trap destination. |
| STR labelTFTPserver | 1.3.6.1.4.1.1166.6.1.2.3.3.2.16 | DisplayString | read-only | This object provides the label the TFTP Server address field. |
| STR valueTFTPserver | 1.3.6.1.4.1.1166.6.1.2.3.3.2.17 | DisplayString | read-write | This object provides the address for the TFTP Server. |
| STR labelTrap2Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.18 | DisplayString | read-only | This object provides the label the second trap destination field. |
| STR valueTrap2Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.19 | DisplayString | read-write | This object provides the address for the second trap destination. |
| STR labelTrap3Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.20 | DisplayString | read-only | This object provides the label the third trap destination field. |
| STR valueTrap3Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.21 | DisplayString | read-write | This object provides the address for the third trap destination. |
| STR labelTrap4Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.22 | DisplayString | read-only | This object provides the label the fourth trap destination field. |
| STR valueTrap4Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.23 | DisplayString | read-write | This object provides the address for the fourth trap destination. |
| STR labelTrap5Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.24 | DisplayString | read-only | This object provides the label the fifth trap destination field. |
| STR valueTrap5Destination | 1.3.6.1.4.1.1166.6.1.2.3.3.2.25 | DisplayString | read-write | This object provides the address for the fifth trap destination. |
| STR labelISDNMode | 1.3.6.1.4.1.1166.6.1.2.3.3.2.26 | DisplayString | read-only | This object provides the label for the ISDN mode setting. |
| INT valueISDNMode | 1.3.6.1.4.1.1166.6.1.2.3.3.2.27 | INTEGER | read-write | This object provides the value for the ISDN mode setting. In order to activate the ISDN feature, the user must set the ISDN mode to ON and provide a valid IP address. This address needs to be the IP address of the remote ISDN Modem. |
| STR labelISDNModemIPAddress | 1.3.6.1.4.1.1166.6.1.2.3.3.2.28 | DisplayString | read-only | This object provides the label for the ISDN modem IP Address. |
| STR valueISDNModemIPAddress | 1.3.6.1.4.1.1166.6.1.2.3.3.2.29 | DisplayString | read-write | This object provides the value for the ISDN modem IP Address. This Address is used by the control Module to ping the remote ISDN modem to determine if an ISDN connection is made. Only after a successful ping response to this address and the ISDN Modem Mode object is set to ON will the Control Module send traps. Factory default value is 0.0.0.0. |
| STR labelISDNTrapTimeout | 1.3.6.1.4.1.1166.6.1.2.3.3.2.30 | DisplayString | read-only | This object provides the label for the ISDN modem Timeout object. |
| INT valueISDNTrapTimeout | 1.3.6.1.4.1.1166.6.1.2.3.3.2.31 | INTEGER | read-write | This object provides the value for the ISDN modem Timeout. The value of this object sets the time period that the communication link is open for sending traps. This timer is started when the first trap is issued. The factory default for this value is 2 minutes. Unit of measure is in seconds. |
| STR labelISDNPingTimeout | 1.3.6.1.4.1.1166.6.1.2.3.3.2.32 | DisplayString | read-only | This object provides the label for the ISDN ping timeout object. |
| INT valueISDNPingTimeout | 1.3.6.1.4.1.1166.6.1.2.3.3.2.33 | INTEGER | read-write | This object provides the value for the ISDN ping timeout. Factory default value is 500 ms. User should set this value in milli-second |
| STR labelISDNBackoffTimer | 1.3.6.1.4.1.1166.6.1.2.3.3.2.34 | DisplayString | read-only | This object provides the label for the ISDN backoff timer object. |
| INT valueISDNBackoffTimer | 1.3.6.1.4.1.1166.6.1.2.3.3.2.35 | INTEGER | read-write | This object provides the value for the ISDN backoff timer. The value in this object is a hold period used to prevent traps from being sent. It is used to allow other chassis to have time to connect and communicate over the ISDN modems. This hold period starts after the valueISDNTrapTimeout period has expired. NOTE: The value of this object should be set to a value greater than the ISDN Modem's idle connection timeout period. This will allow the Modem to break the ISDN Connection. Factory default value is 2 min (120 sec). User should set this value in seconds |
| gx2cmAnalogTable | 1.3.6.1.4.1.1166.6.1.2.3.4 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.3.4.3 | not-accessible | This list contains analog parameters and the associated parameter descriptions. | |
| INT gx2cmTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Module Temp parameter. |
| STR uomModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temp parameter. |
| FLO majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.4 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temp parameter. |
| FLO majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temp parameter. |
| FLO minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temp parameter. |
| FLO minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temp parameter. |
| FLO currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.8 | Float | read-only | The value of this object provides the Current value of the Module Temp parameter. |
| INT stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.9 | INTEGER | read-only | The value of this object provides the state of the Module Temp parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.10 | Float | read-only | The value of this object provides the minimum value the Module Temp parameter can achive. |
| FLO maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.11 | Float | read-only | The value of this object provides the maximum value the Module Temp parameter can achive. |
| INT alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.3.4.3.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temp Analog parameter. |
| gx2cmDigitalTable | 1.3.6.1.4.1.1166.6.1.2.3.5 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.3.5.4 | not-accessible | This list contains digital parameters and the associated parameter descriptions. | |
| INT gx2cmDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelRemoteLocal | 1.3.6.1.4.1.1166.6.1.2.3.5.4.2 | DisplayString | read-only | The value of this object provides the label of the Remote Local Control Digital parameter. |
| STR enumRemoteLocal | 1.3.6.1.4.1.1166.6.1.2.3.5.4.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1. |
| INT valueRemoteLocal | 1.3.6.1.4.1.1166.6.1.2.3.5.4.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT stateFlagRemoteLocal | 1.3.6.1.4.1.1166.6.1.2.3.5.4.5 | INTEGER | read-only | The value of this object provides the state of the Remote Local Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelResetSlot | 1.3.6.1.4.1.1166.6.1.2.3.5.4.6 | DisplayString | read-only | The value of this object provides the label of the Reset Slot Digital parameter. |
| STR enumResetSlot | 1.3.6.1.4.1.1166.6.1.2.3.5.4.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1. |
| INT valueResetSlot | 1.3.6.1.4.1.1166.6.1.2.3.5.4.8 | INTEGER | read-write | The value of this object is the current value of the parameter. A write to this object will casue a hardware reset. 0-control module 1-18 selected slot. |
| INT stateResetSlot | 1.3.6.1.4.1.1166.6.1.2.3.5.4.9 | INTEGER | read-only | The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelIdShelf | 1.3.6.1.4.1.1166.6.1.2.3.5.4.10 | DisplayString | read-only | The value of this object provides the label of the identify shelf Digital parameter. |
| STR enumIdShelf | 1.3.6.1.4.1.1166.6.1.2.3.5.4.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1.. |
| INT valueIdShelf | 1.3.6.1.4.1.1166.6.1.2.3.5.4.12 | INTEGER | read-write | The value of this object is the current value of the parameter. Writing any non zero value to this parameter will casue the CM to blink its front panel LED. |
| INT stateFlagIdShelf | 1.3.6.1.4.1.1166.6.1.2.3.5.4.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR labelResetAlarm | 1.3.6.1.4.1.1166.6.1.2.3.5.4.14 | DisplayString | read-only | The value of this object provides the label of the Reset Alarms Digital parameter. |
| STR enumResetAlarm | 1.3.6.1.4.1.1166.6.1.2.3.5.4.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1. |
| INT valueResetAlarm | 1.3.6.1.4.1.1166.6.1.2.3.5.4.16 | INTEGER | read-write | The value of this object is the current value of the parameter. Writing any non-zero value to this object will case the CM to reset shelf alarm processing. |
| INT stateFlagResetAlarm | 1.3.6.1.4.1.1166.6.1.2.3.5.4.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2cmStatusTable | 1.3.6.1.4.1.1166.6.1.2.3.6 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmStatusEntry | 1.3.6.1.4.1.1166.6.1.2.3.6.5 | not-accessible | This list contains status parameters and the associated parameter descriptions. | |
| INT gx2cmStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.6.5.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelShelfAlarm | 1.3.6.1.4.1.1166.6.1.2.3.6.5.2 | DisplayString | read-only | The value of this object provides the label of the Shelf Alarm Status parameter. |
| INT valueShelfAlarm | 1.3.6.1.4.1.1166.6.1.2.3.6.5.3 | INTEGER | read-only | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateShelfAlarm | 1.3.6.1.4.1.1166.6.1.2.3.6.5.4 | INTEGER | read-only | The value of this object provides the current state of the parameter. |
| STR labelDataCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.5 | DisplayString | read-only | The value of this object provides the label of the Data CRC parameter. |
| INT valueDataCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.6 | INTEGER | read-only | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateDataCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.7 | INTEGER | read-only | The value of this object provides the current state of the parameter. |
| STR labelFlashStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.8 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT valueFlashStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.9 | INTEGER | read-only | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateFlashStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.10 | INTEGER | read-only | The value of this object provides the current state of the parameter. |
| STR labelBootStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.11 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT valueBootStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.12 | INTEGER | read-only | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateBootStatus | 1.3.6.1.4.1.1166.6.1.2.3.6.5.13 | INTEGER | read-only | The value of this object provides the current state of the parameter. |
| STR labelAlmLimCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.14 | DisplayString | read-only | The value of this object provides the label of the Alarm limit CRC parameter. |
| INT valueAlmLimCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.15 | INTEGER | read-only | The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT stateAlmLimCrc | 1.3.6.1.4.1.1166.6.1.2.3.6.5.16 | INTEGER | read-only | The value of this object provides the current state of the parameter. |
| gx2cmAMCTable | 1.3.6.1.4.1.1166.6.1.2.3.7 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmAMCEntry | 1.3.6.1.4.1.1166.6.1.2.3.7.6 | not-accessible | This list contains the AMC parameters and the associated parameter descriptions. | |
| INT gx2cmAMCTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.7.6.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT valueAMCslot1 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.2 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot1 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.3 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot1 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.4 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot2 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.5 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot2 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.6 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot2 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.7 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot3 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.8 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot3 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.9 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot3 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.10 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot4 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.11 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot4 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.12 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot4 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.13 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot5 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.14 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot5 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.15 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot5 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.16 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot6 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.17 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot6 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.18 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot6 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.19 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot7 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.20 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot7 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.21 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot7 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.22 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot8 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.23 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot8 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.24 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot8 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.25 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot9 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.26 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot9 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.27 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot9 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.28 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot10 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.29 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot10 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.30 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot10 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.31 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot11 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.32 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot11 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.33 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot11 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.34 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot12 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.35 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot12 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.36 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot12 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.37 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot13 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.38 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot13 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.39 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot13 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.40 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot14 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.41 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot14 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.42 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot14 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.43 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot15 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.44 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot15 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.45 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot15 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.46 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot16 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.47 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot16 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.48 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot16 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.49 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot17 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.50 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot17 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.51 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot17 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.52 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT valueAMCslot18 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.53 | INTEGER | read-write | This object provides control to enable or disable AMC for the current device in the slot. |
| STR serialAMCslot18 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.54 | DisplayString | read-only | This object provides the serial number for the AMC slot selected. |
| INT agentIDAMCslot18 | 1.3.6.1.4.1.1166.6.1.2.3.7.6.55 | INTEGER | read-only | This object provides the agentID of the AMC parameter for the selected slot. |
| INT autoQuickSwapCnt | 1.3.6.1.4.1.1166.6.1.2.3.7.6.56 | INTEGER | read-write | This object sets the time interval as to when the Control Module will update its memory with quick swap data. The Control Module will enable the quick swap feature for each module in the system. It will then retrieve the quick swap data from each module. The timer settings are as follows: 1=timeroff, 2=onehour, 3=oneday, 4=oneweek. |
| gx2cmSecurityTable | 1.3.6.1.4.1.1166.6.1.2.3.8 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmSecurityEntry | 1.3.6.1.4.1.1166.6.1.2.3.8.7 | not-accessible | This list contains Security parameters and the associated parameter descriptions. | |
| INT gx2cmSecurityTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.8.7.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR labelSecurityMode | 1.3.6.1.4.1.1166.6.1.2.3.8.7.2 | DisplayString | read-only | This object provides the label for the Current Security Mode. |
| STR enumSecurityMode | 1.3.6.1.4.1.1166.6.1.2.3.8.7.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the security mode parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1. |
| INT valueSecurityMode | 1.3.6.1.4.1.1166.6.1.2.3.8.7.4 | INTEGER | read-only | This object indicates the current Security Mode. |
| INT stateSecurityMode | 1.3.6.1.4.1.1166.6.1.2.3.8.7.5 | INTEGER | read-only | This object indicates the state of the Security Mode parameter . |
| STR labelPassword | 1.3.6.1.4.1.1166.6.1.2.3.8.7.6 | DisplayString | read-only | This object provides the label for the Password field. |
| STR valuePassword | 1.3.6.1.4.1.1166.6.1.2.3.8.7.7 | DisplayString | read-write | This object provides the value for the Password. |
| INT statePassword | 1.3.6.1.4.1.1166.6.1.2.3.8.7.8 | INTEGER | read-only | This object provides the state of the password field. |
| STR labelFactoryChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.9 | DisplayString | read-only | This object provides the lable for the Factory Change String field. |
| STR valueFactoryChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.10 | DisplayString | write-only | This object provides the value for the Factory Change String. |
| INT stateFactoryChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.11 | INTEGER | read-only | This object provides the state of the Factory Change String field. |
| STR labelOperatorChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.12 | DisplayString | read-only | This object provides the lable for the Operator Change String field. |
| STR valueOperatorChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.13 | DisplayString | write-only | This object provides the value for the Operator Change String. |
| INT stateOperatorChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.14 | INTEGER | read-only | This object provides the state of the Operator Change String field. |
| STR labelReadOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.15 | DisplayString | read-only | This object provides the lable for the Read Only Change String field. |
| STR valueReadOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.16 | DisplayString | write-only | This object provides the value for the Read Only Change String. |
| INT stateReadOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.17 | INTEGER | read-only | This object provides the state of the Read Only Change String field. |
| STR labelRemoteOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.18 | DisplayString | read-only | This object provides the lable for the Remote Only Change String field. |
| STR valueRemoteOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.19 | DisplayString | write-only | This object provides the value for the Remote Only Change String. |
| INT stateRemoteOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.20 | INTEGER | read-only | This object provides the state of the Remote Only Change String field. |
| STR labelLocalOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.21 | DisplayString | read-only | This object provides the lable for the Local Only Change String field. |
| STR valueLocalOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.22 | DisplayString | write-only | This object provides the value for the Local Only Change String. |
| INT stateLocalOnlyChgString | 1.3.6.1.4.1.1166.6.1.2.3.8.7.23 | INTEGER | read-only | This object provides the state of the Local Only Change String field. |
| gx2cmDiagnosticTable | 1.3.6.1.4.1.1166.6.1.2.3.9 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmDiagnosticEntry | 1.3.6.1.4.1.1166.6.1.2.3.9.8 | not-accessible | This list contains Diagnostic parameters and the associated parameter descriptions. | |
| INT gx2cmDiagnosticTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.9.8.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT ledTestValue | 1.3.6.1.4.1.1166.6.1.2.3.9.8.2 | INTEGER | read-write | This object provides the LED test pattern on/off control. |
| INT bpTestCnt | 1.3.6.1.4.1.1166.6.1.2.3.9.8.3 | INTEGER | read-write | The value of this object control which slot the alarm poll command will be repeatedly sent to. During this operation normal polling is disabled. 0-off, 1-18 selects the slot. |
| INT successTransSlot1 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.4 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot2 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.5 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot3 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.6 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot4 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.7 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot5 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.8 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot6 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.9 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot7 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.10 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot8 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.11 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot9 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.12 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot10 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.13 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot11 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.14 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot12 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.15 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot13 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.16 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot14 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.17 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot15 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.18 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot16 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.19 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot17 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.20 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT successTransSlot18 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.21 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot passes. |
| INT failureTransSlot1 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.22 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot2 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.23 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot3 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.24 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot4 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.25 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot5 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.26 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot6 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.27 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot7 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.28 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot8 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.29 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot9 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.30 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot10 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.31 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot11 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.32 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot12 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.33 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot13 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.34 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot14 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.35 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot15 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.36 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot16 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.37 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot17 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.38 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT failureTransSlot18 | 1.3.6.1.4.1.1166.6.1.2.3.9.8.39 | INTEGER | read-write | This object provides data on the number of time writing to the selected slot fails. |
| INT fanTestMode | 1.3.6.1.4.1.1166.6.1.2.3.9.8.40 | INTEGER | read-write | This object provides control for putting the fan in manual test mode. Writing any non-zero value will set to on |
| INT fanControl | 1.3.6.1.4.1.1166.6.1.2.3.9.8.41 | INTEGER | read-write | This object provides control over the fan mode. |
| INT relayTestMode | 1.3.6.1.4.1.1166.6.1.2.3.9.8.42 | INTEGER | read-write | This object provides control for putting the relay in manual test mode. Writing any non-zero value will set to on |
| INT relayControl | 1.3.6.1.4.1.1166.6.1.2.3.9.8.43 | INTEGER | read-write | This object provides control for putting the relay in manual test mode. |
| INT slotPollMode | 1.3.6.1.4.1.1166.6.1.2.3.9.8.44 | INTEGER | read-write | This object provides control of the slotpoll test mode. When on the slotpoll operation is disabled. |
| INT bootCount | 1.3.6.1.4.1.1166.6.1.2.3.9.8.45 | INTEGER | read-write | This object provides the value of how many times the CM went though a boot/rest process. |
| STR objectTableData | 1.3.6.1.4.1.1166.6.1.2.3.9.8.46 | DisplayString | read-only | This object provides the OID for the start loations for the status, digital and analog tables. This data is used by the web server application. |
| INT setSysTime | 1.3.6.1.4.1.1166.6.1.2.3.9.8.47 | INTEGER | read-write | Writing any value to this object will reset sysUpTime to zero. |
| gx2cmDownloadTable | 1.3.6.1.4.1.1166.6.1.2.3.10 | not-accessible | This table contains gx2Cm specific parameters with nominal and current values. | |
| gx2cmDownloadEntry | 1.3.6.1.4.1.1166.6.1.2.3.10.9 | not-accessible | This list contains Download parameters and the associated parameter descriptions. | |
| INT gx2cmDownloadTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.10.9.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT downloadValue | 1.3.6.1.4.1.1166.6.1.2.3.10.9.2 | INTEGER | read-write | This object provides the slot(s) to be downloaded. The slots to be downloaded corresponds to the following bit map. bit 0 - control module, bits 1-18 to the corresponding slot. Any combination of bit may be set. If all bits are reset this will halt the download. |
| INT autoDownloadReset | 1.3.6.1.4.1.1166.6.1.2.3.10.9.3 | INTEGER | read-write | This object determines if the module will be reset directly after a successfull download. 0 - Deactivated, 1+ Activated |
| STR downloadFilename | 1.3.6.1.4.1.1166.6.1.2.3.10.9.4 | DisplayString | read-write | This object provides the name of the file for download |
| INT downloadState | 1.3.6.1.4.1.1166.6.1.2.3.10.9.5 | INTEGER | read-write | This object provides the current state of the download process. |
| INT switchFwBank | 1.3.6.1.4.1.1166.6.1.2.3.10.9.6 | INTEGER | read-write | Writting to this object causes the firmware bank to switch and execute from that bank. The range of values that can be entered for this object is from 0 to 18. Where 0 is slot 0, and 18 is slot 18. |
| cmTrapHistoryTable | 1.3.6.1.4.1.1166.6.1.2.3.11 | not-accessible | This table contains the trap specific parameters. | |
| cmTrapHistoryEntry | 1.3.6.1.4.1.1166.6.1.2.3.11.10 | not-accessible | This list contains Trap History parameters and the associated parameter descriptions. | |
| INT cmTrapHistoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.3.11.10.1 | INTEGER | read-only | This object identifies the trap issued by the network element. |
| INT netrapId | 1.3.6.1.4.1.1166.6.1.2.3.11.10.2 | INTEGER | read-only | The value of this objest is the trap ID number provided by network element. |
| STR netrapNetworkElemModelNumber | 1.3.6.1.4.1.1166.6.1.2.3.11.10.3 | DisplayString | read-only | The value of this object is the model number of the network element. Combination of Model # and Serial # is used as the unique identifier of the NE. |
| STR netrapNetworkElemSerialNum | 1.3.6.1.4.1.1166.6.1.2.3.11.10.4 | DisplayString | read-only | The value of this object is the serial number of the network element. |
| INT netrapPerceivedSeverity | 1.3.6.1.4.1.1166.6.1.2.3.11.10.5 | INTEGER | read-only | This parameter defines five severity levels, which provide an indication of the perceived status of the managed object. |
| INT netrapNetworkElemOperState | 1.3.6.1.4.1.1166.6.1.2.3.11.10.6 | INTEGER | read-only | The current Operational State of the Network Element which generated the trap.. |
| INT netrapNetworkElemAlarmStatus | 1.3.6.1.4.1.1166.6.1.2.3.11.10.7 | INTEGER | read-only | The current Alarm Status of the Network Element. Alarm Status is always equal to the highest severity level of all outstanding alarms in this NE.. |
| INT netrapNetworkElemAdminState | 1.3.6.1.4.1.1166.6.1.2.3.11.10.8 | INTEGER | read-only | The current Adminsitrative state of the network element. |
| INT netrapNetworkElemAvailStatus | 1.3.6.1.4.1.1166.6.1.2.3.11.10.9 | INTEGER | read-only | The current Operational state of the network elment |
| STR netrapText | 1.3.6.1.4.1.1166.6.1.2.3.11.10.10 | DisplayString | read-only | This variable contains trap text. |
| TIK netrapLastTrapTimeStamp | 1.3.6.1.4.1.1166.6.1.2.3.11.10.11 | TimeTicks | read-only | This OBJECT IDENTIFIER is used to hold time when trap was generated. |
| STR netrapChangedObjectId | 1.3.6.1.4.1.1166.6.1.2.3.11.10.12 | DisplayString | read-only | This variable identifies the object that has generated the trap. |
| INT netrapAdditionalInfoInteger1 | 1.3.6.1.4.1.1166.6.1.2.3.11.10.13 | INTEGER | read-only | This 32 bit integer is used to hold specific information about the trap. |
| INT netrapAdditionalInfoInteger2 | 1.3.6.1.4.1.1166.6.1.2.3.11.10.14 | INTEGER | read-only | this 32 bit integer is used to hold specific information about the trap. |
| INT netrapAdditionalInfoInteger3 | 1.3.6.1.4.1.1166.6.1.2.3.11.10.15 | INTEGER | read-only | This 32 bit integer is used to hold specific information about the trap. |
| STR netrapChangedValueDisplayString | 1.3.6.1.4.1.1166.6.1.2.3.11.10.16 | DisplayString | read-only | This DisplayString is used to hold specific information about the trap |
| STR netrapChangedValueOID | 1.3.6.1.4.1.1166.6.1.2.3.11.10.17 | DisplayString | read-only | This OBJECT IDENTIFIER is used to hold specific information about the trap |
| INT netrapChangedValueIpAddress | 1.3.6.1.4.1.1166.6.1.2.3.11.10.18 | INTEGER | read-only | This OBJECT IDENTIFIER is used to hold specific information about the trap. |
| INT netrapChangedValueInteger | 1.3.6.1.4.1.1166.6.1.2.3.11.10.19 | INTEGER | read-only | this 32 bit integer is used to hold the data value that this object has been changed too. |
RFC description
Manages GX2 Control Module parameters for HFC (Hybrid Fiber-Coax) network elements in cable television distribution systems.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.