OMNI-gx2CM-MIB :: hourMeter

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2CM-MIB › hourMeter

hourMeter

Module: OMNI-gx2CM-MIB

OID (symbolic): OMNI-gx2CM-MIB::hourMeter

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.3.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object provides the hour meter reading of the module.

What is hourMeter?

A running count of the hours the module has been powered on, giving admins an age/usage indicator for the hardware independent of when it was physically installed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.3.2.1.9
snmpwalk -v2c -c public <target> OMNI-gx2CM-MIB::hourMeter

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.3.2.1.9.1
snmpget -v2c -c public <target> OMNI-gx2CM-MIB::hourMeter.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2CM-MIB::hourMeter OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.3gx2CmGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.3.2gx2cmFactoryTableOMNI-gx2CM-MIB
1.3.6.1.4.1.1166.6.1.2.3.2.1gx2cmFactoryEntryOMNI-gx2CM-MIB
1.3.6.1.4.1.1166.6.1.2.3.2.1.9hourMeterOMNI-gx2CM-MIB