All MIBs › OMNI-gx2CM-MIB › valueISDNTrapTimeout
valueISDNTrapTimeout
Module: OMNI-gx2CM-MIB
OID (symbolic): OMNI-gx2CM-MIB::valueISDNTrapTimeout
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.3.3.2.31
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object provides the value for the ISDN modem Timeout. The value of this object sets the time period that the communication link is open for sending traps. This timer is started when the first trap is issued. The factory default for this value is 2 minutes. Unit of measure is in seconds.
What is valueISDNTrapTimeout?
The number of seconds (0-3600) the ISDN communication link stays open for sending traps once the first trap starts the timer; factory default is 120 seconds (2 minutes). Admins raise this if traps are being cut off before delivery on a slow dial-up link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.3.3.2.31 snmpwalk -v2c -c public <target> OMNI-gx2CM-MIB::valueISDNTrapTimeout
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.3.3.2.31.1 snmpget -v2c -c public <target> OMNI-gx2CM-MIB::valueISDNTrapTimeout.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.3.3.2.31.1 i <value>
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2CM-MIB::valueISDNTrapTimeout OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (gx2CM combiner module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.3 | gx2Cm | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.3.3 | gx2cmNetworkTable | OMNI-gx2CM-MIB |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2 | gx2cmNetworkEntry | OMNI-gx2CM-MIB |
| 1.3.6.1.4.1.1166.6.1.2.3.3.2.31 | valueISDNTrapTimeout | OMNI-gx2CM-MIB |