All MIBs › OMNI-gx2CEB-MIB
Category: CATV and HFC
Description: Manages the Cisco/Scientific Atlanta GX2 CEB (Control and Element Bus) module configuration and status in HFC networks.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2CEB-MIB?
OMNI-gx2CEB-MIB is a Blonder Tongue (BBN/GX2 HFC headend heritage) proprietary MIB reporting gx2CEB (a cable-headend combiner/EDFA-related module) analog telemetry against nominal ranges. Its analog table, keyed by index, records per-parameter (module temperature, fan current, and others) label, unit of measure, major/minor high/low threshold, current value, state flag, min/max recorded value, and alarm state, while companion status and factory tables cover discrete status and factory-set data. As a hardware-performance MIB it lets an administrator watch a gx2CEB module's temperature and fan current against alarm thresholds in an HFC headend. It is deployed on Blonder Tongue (GX2) HFC headend equipment. Engineers can download the OMNI-gx2CEB-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2CEB-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (gx2CEB combiner/EDFA module)
Monitoring Examples
An administrator monitors cebcurrentValueModTemp against cebmajorHighModTemp to catch an overheating gx2CEB module in an HFC headend before it triggers a critical alarm.
What Can Be Monitored
- gx2CEB module temperature/fan-current vs. alarm thresholds
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2CEB | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapCEBConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.20.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapCEBConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.20.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapCEBfanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.3 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCEBModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.4 | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapCEBFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.5 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapCEBBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.6 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapCEBAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.7 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapCEBFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.20.0.8 | This trap is issued when the Factory Data CRC is incorrect. | ||
| gx2CEBDescriptor | 1.3.6.1.4.1.1166.6.1.2.20.1 | |||
| gx2CEBAnalogTable | 1.3.6.1.4.1.1166.6.1.2.20.2 | not-accessible | This table contains gx2CEB specific parameters with nominal and current values. | |
| gx2CEBAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.20.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2CEBAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR ceblabelModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR cebuomModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO cebmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.8 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.10 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.11 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.20.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR ceblabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR cebuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO cebmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.19 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.21 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.22 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.20.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR ceblabelAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Analog Voltage number 01 Analog parameter. |
| STR cebuomAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter. |
| FLO cebmajorHighAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.30 | Float | read-only | The value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.32 | Float | read-only | The value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.33 | Float | read-only | The value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateAnalogVoltage01 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. |
| STR ceblabelAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Analog Voltage number 02 Analog parameter. |
| STR cebuomAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter. |
| FLO cebmajorHighAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.41 | Float | read-only | The value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.43 | Float | read-only | The value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.44 | Float | read-only | The value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateAnalogVoltage02 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter. |
| STR ceblabelAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Analog Voltage number 03 Analog parameter. |
| STR cebuomAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter. |
| FLO cebmajorHighAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.52 | Float | read-only | The value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.54 | Float | read-only | The value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.55 | Float | read-only | The value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateAnalogVoltage03 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter. |
| STR ceblabelAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Analog Voltage number 04 Analog parameter. |
| STR cebuomAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter. |
| FLO cebmajorHighAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.63 | Float | read-only | The value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.65 | Float | read-only | The value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.66 | Float | read-only | The value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateAnalogVoltage04 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter. |
| STR ceblabelAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Analog Voltage number 05 Analog parameter. |
| STR cebuomAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter. |
| FLO cebmajorHighAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebmajorLowAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorHighAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebminorLowAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused |
| FLO cebcurrentValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.74 | Float | read-only | The value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebstateFlagAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO cebminValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.76 | Float | read-only | The value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO cebmaxValueAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.77 | Float | read-only | The value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT cebalarmStateAnalogVoltage05 | 1.3.6.1.4.1.1166.6.1.2.20.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter. |
| gx2CEBStatusTable | 1.3.6.1.4.1.1166.6.1.2.20.3 | not-accessible | This table contains gx2CEB specific parameters with nominal and current values. | |
| gx2CEBStatusEntry | 1.3.6.1.4.1.1166.6.1.2.20.3.2 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2CEBStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR ceblabelBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT cebvalueBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT cebstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.20.3.2.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ceblabelFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT cebvalueFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT cebstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.20.3.2.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ceblabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT cebvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT cebstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.20.3.2.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR ceblabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT cebvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT cebstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.20.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2CEBFactoryTable | 1.3.6.1.4.1.1166.6.1.2.20.4 | not-accessible | This table contains gx2CEB specific parameters with nominal and current values. | |
| gx2CEBFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.20.4.3 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2CEBFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.20.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT cebbootControlByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT cebbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.3 | INTEGER | read-only | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail) |
| INT cebbank1CRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.4 | INTEGER | read-only | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| INT cebbank2CRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.5 | INTEGER | read-only | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| INT cebprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.20.4.3.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT cebfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT cebcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.20.4.3.8 | INTEGER | read-only | This object indicates which of the Enums will have the CRC calculated. |
| INT cebhourMeter | 1.3.6.1.4.1.1166.6.1.2.20.4.3.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT cebflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.20.4.3.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT cebflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.20.4.3.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR cebflashBankARev | 1.3.6.1.4.1.1166.6.1.2.20.4.3.12 | DisplayString | read-only | This object provides the revision of flash bank 0. The rev is 2 characters. |
| STR cebflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.20.4.3.13 | DisplayString | read-only | This object provides the revision of flash bank 1. The rev is 2 characters. |
RFC description
Manages HFC network elements for OMNISTAR DM 1550 laser module in cable systems.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2CEB combiner/EDFA module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.