All MIBs › OMNI-gx2drr2x-MIB
Category: CATV and HFC
Description: Manages the Cisco/Scientific Atlanta GX2 DRR2X dual return receiver module configuration in HFC cable plants.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2drr2x-MIB?
OMNI-gx2drr2x-MIB is a vendor MIB for the Cisco/Scientific Atlanta GX2 DRR2X, a dual return receiver module used in HFC cable plants to receive upstream (return path) RF signals from subscriber-facing equipment. It exposes configuration objects for the receiver's two return-path channels along with module status information within the GX2 chassis. Its main use is monitoring the hardware health of the return receiver, so an operator can detect a failed receive channel, low receive signal level, or a module that has dropped offline, all of which would disrupt upstream data or telemetry from the plant. It belongs to the OMNI-gx2 family of modules alongside the laser, amplifier, and switch MIBs, sharing a common chassis management approach. It is typically deployed in cable headend or hub HFC plants managing return-path RF reception. Engineers can download the OMNI-gx2drr2x-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2drr2x-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR2X dual return receiver module)
Monitoring Examples
No sample object names were provided for this module; in practice an operator would poll the DRR2X's per-channel receive-level and module-status objects within the GX2 chassis tree. A drop in receive signal level on one of the two return channels would reveal a failing receiver path affecting upstream traffic from part of the plant. It is typically monitored alongside sibling OMNI-gx2 module MIBs covering the rest of the optical node or headend chassis.
What Can Be Monitored
- per-channel return receive level
- module operational status
- receiver channel configuration
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Drr2x | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapdrrConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.21.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrrConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.21.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrr12VCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.3 | This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.4 | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.5 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapdrrBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.7 | This trap is issued when the module detects an error while booting from bank 0 or bank 1. | ||
| NTF trapdrrAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.8 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapdrrHardwareErrAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.9 | This trap is issued when hardware is abnormal. | ||
| NTF trapdrrOpticalSignalAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.10 | This trap is issued when the optical signal is beyond the preset range. | ||
| NTF trapdrrFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.11 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapdrrResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.12 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapdrrTripPointAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.13 | This trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. | ||
| NTF trapdrrLinkAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.14 | This trap is issued when receiver is out of SYN with transmitter | ||
| NTF trapdrrCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.21.0.15 | This trap is issued when the Calibration Data CRC is incorrect | ||
| gx2drr2xDescriptor | 1.3.6.1.4.1.1166.6.1.2.21.1 | |||
| gx2drr2xAnalogTable | 1.3.6.1.4.1.1166.6.1.2.21.2 | not-accessible | This table contains gx2drr2x specific analog parameters with nominal,limits and current values. | |
| gx2drr2xAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.21.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2drr2xAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.21.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr2xlabelRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.2 | DisplayString | read-only | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| STR drr2xuomRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB |
| FLO drr2xmajorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.4 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xmajorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.5 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.6 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.7 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xcurrentValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.8 | Float | read-write | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. |
| INT drr2xstateFlagRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.9 | INTEGER | read-only | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.10 | Float | read-only | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. |
| FLO drr2xmaxValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.11 | Float | read-only | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. |
| INT drr2xalarmStateRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| STR drr2xlabelRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.13 | DisplayString | read-only | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| STR drr2xuomRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| FLO drr2xmajorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.15 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xmajorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.16 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.17 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.18 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence. |
| FLO drr2xcurrentValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.19 | Float | read-write | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB |
| INT drr2xstateFlagRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.20 | INTEGER | read-only | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.21 | Float | read-only | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. |
| FLO drr2xmaxValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.22 | Float | read-only | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. |
| INT drr2xalarmStateRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.21.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| STR drr2xlabelTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.24 | DisplayString | read-only | The value of this object provides the label of the trip point level Analog parameter. |
| STR drr2xuomTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| FLO drr2xmajorHighTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.26 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xmajorLowTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.27 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorHighTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.28 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorLowTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.29 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xcurrentValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.30 | Float | read-write | The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drr2xstateFlagTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.31 | INTEGER | read-only | The value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.32 | Float | read-only | The value of this object provides the minimum value the trip point level Analog parameter can achive. |
| FLO drr2xmaxValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.33 | Float | read-only | The value of this object provides the maximum value the trip point level Analog parameter can achive. |
| INT drr2xalarmStateTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.21.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| STR drr2xlabelOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Current Analog parameter. |
| STR drr2xuomOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| FLO drr2xmajorHighOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. |
| FLO drr2xmajorLowOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. |
| FLO drr2xminorHighOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.39 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorLowOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.40 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xcurrentValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr2xcurrentValueOptCurrent will report -99dBm The input optical power in higher than this value, drr2xcurrentValueOptCurrent will report 99dBm |
| INT drr2xstateFlagOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.43 | Float | read-only | This is recommended min range for display gauge |
| FLO drr2xmaxValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.44 | Float | read-only | This is recommended max range for display gauge |
| INT drr2xalarmStateOptCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| STR drr2xlabel12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.46 | DisplayString | read-only | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| STR drr2xuom12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| FLO drr2xmajorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. |
| FLO drr2xmajorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. |
| FLO drr2xminorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. |
| FLO drr2xminorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. |
| FLO drr2xcurrentValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.52 | Float | read-only | The value of this object provides the Current value of the 12v power supply Current parameter. |
| INT drr2xstateFlag12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.53 | INTEGER | read-only | The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.54 | Float | read-only | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. |
| FLO drr2xmaxValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.55 | Float | read-only | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. |
| INT drr2xalarmState12VCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| STR drr2xlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR drr2xuomModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO drr2xmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO drr2xmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO drr2xminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO drr2xminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO drr2xcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.63 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT drr2xstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.65 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| FLO drr2xmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.66 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| INT drr2xalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.21.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR drr2xlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR drr2xuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO drr2xmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| FLO drr2xmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| FLO drr2xminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.72 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.73 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr2xcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.74 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. |
| INT drr2xstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr2xminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.76 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| FLO drr2xmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.77 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| INT drr2xalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.21.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2drr2xDigitalTable | 1.3.6.1.4.1.1166.6.1.2.21.3 | not-accessible | This table contains gx2drr2x specific digital parameters with nominal and current values. | |
| gx2drr2xDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.21.3.2 | not-accessible | This list contains individual digital parameters and descriptions. | |
| INT gx2drr2xDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.21.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr2xlabelTrippointMode | 1.3.6.1.4.1.1166.6.1.2.21.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR |
| STR drr2xenumTrippointMode | 1.3.6.1.4.1.1166.6.1.2.21.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT drr2xvalueTrippointMode | 1.3.6.1.4.1.1166.6.1.2.21.3.2.4 | INTEGER | read-write | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml |
| INT drr2xstateflagTrippointMode | 1.3.6.1.4.1.1166.6.1.2.21.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.21.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR drr2xenumFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.21.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT drr2xvalueFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.21.3.2.8 | INTEGER | read-write | The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter |
| INT drr2xstateflagFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.21.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2drr2xStatusTable | 1.3.6.1.4.1.1166.6.1.2.21.4 | not-accessible | This table contains gx2drr2x specific status parameters with nominal and current values. | |
| gx2drr2xStatusEntry | 1.3.6.1.4.1.1166.6.1.2.21.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2drr2xStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.21.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr2xlabelBoot | 1.3.6.1.4.1.1166.6.1.2.21.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT drr2xvalueBoot | 1.3.6.1.4.1.1166.6.1.2.21.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.21.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelFlash | 1.3.6.1.4.1.1166.6.1.2.21.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT drr2xvalueFlash | 1.3.6.1.4.1.1166.6.1.2.21.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.21.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.21.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT drr2xvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.21.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.21.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT drr2xvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data Crc parameter. |
| INT drr2xvalueCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.21.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Module Hardware Status parameter. |
| INT drr2xvalueHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.19 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value |
| INT drr2xvalueOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.22 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr2xlabelLinkStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT drr2xvalueLinkStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr2xstateflagLinkStatus | 1.3.6.1.4.1.1166.6.1.2.21.4.3.25 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2drr2xFactoryTable | 1.3.6.1.4.1.1166.6.1.2.21.5 | not-accessible | This table contains gx2drr2x specific factory setting parameters with nominal and current values. | |
| gx2drr2xFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.21.5.4 | not-accessible | This list contains Factory setting parameters and descriptions. | |
| INT gx2drr2xFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.21.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT drr2xbootControlByte | 1.3.6.1.4.1.1166.6.1.2.21.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT drr2xbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.21.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT drr2xbank1CRC | 1.3.6.1.4.1.1166.6.1.2.21.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT drr2xbank2CRC | 1.3.6.1.4.1.1166.6.1.2.21.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT drr2xprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.21.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT drr2xfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.21.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT drr2xcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.21.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration). |
| INT drr2xhourMeter | 1.3.6.1.4.1.1166.6.1.2.21.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT drr2xflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.21.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 0 flash has been programmed. |
| INT drr2xflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.21.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR drr2xflashBankARev | 1.3.6.1.4.1.1166.6.1.2.21.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR drr2xflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.21.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| STR drr2xSubAgentRev | 1.3.6.1.4.1.1166.6.1.2.21.5.4.14 | DisplayString | read-only | This object provides the subagent revision of receiver module. |
RFC description
Omnitron Systems iConverter Management Module MIB for managing multi-chassis iConverter equipment. Defines SNMP objects for configuring secure communication protocols between management modules and remote chassis in optical conversion systems.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR2X dual return receiver module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.