All MIBs › LUM-EQUIPMENT-MIB
Organization: Infinera Corporation
Last Updated: 2019-08-30
Category: Hardware Inventory
Description: Monitors hardware equipment inventory and slot occupancy on Infinera chassis.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is LUM-EQUIPMENT-MIB?
LUM-EQUIPMENT-MIB is an Infinera proprietary MIB providing common equipment configuration and inventory management for optical transport network chassis. It exposes subrack, board, power supply, fan, slot, and optical module status and configuration tables, forming the hardware inventory and health backbone for the platform. It is explicitly designed for monitoring hardware status: board presence/state, power supply health, fan operational status, slot occupancy, and pluggable optical module presence, all critical for detecting hardware faults in a telecom transport node. Being a common-equipment MIB, it is typically referenced by or works alongside other Infinera/Lum MIBs (such as LUM-SYSINFO-MIB) that layer software/system-level monitoring on top of this hardware inventory. It is deployed in service-provider and carrier optical transport/DWDM network elements where NMS systems poll chassis-level hardware health across many geographically distributed nodes. Engineers can download the LUM-EQUIPMENT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in LUM-EQUIPMENT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Infinera optical transport network element / chassis
Monitoring Examples
An operator can walk equipmentSubrackTable to enumerate installed subracks/chassis and their status, then cross-reference equipmentGeneralEquipmentBoardTableSize and the board table to detect an unexpectedly removed or failed line card. Polling the power and fan tables (sized via equipmentGeneralEquipmentPowerTableSize and equipmentGeneralEquipmentFanTableSize) surfaces power supply or fan failures before they cause thermal shutdown, while equipmentGeneralEquipmentSlotTableSize and the optical module table track transceiver presence per slot for capacity and inventory planning.
What Can Be Monitored
- subrack/board presence and status
- power supply health
- fan status
- slot occupancy
- optical module (transceiver) inventory
This MIB depends on
Related MIBs
Imported Objects
From LUM-ALARM-MIB
| AlarmPerceivedSeverity |
From LUM-REG
| lumEquipmentMIB | OBJECT-IDENTITY |
| lumModules | OBJECT-IDENTITY |
From LUM-TC
| AdminStatus | |
| BoardOrInterfaceAdminStatus | |
| BoardOrInterfaceOperStatus | |
| CommandString | |
| FaultStatus | |
| MgmtNameString | |
| ObjectProperty | |
| SlotNumber | |
| SubrackNumber | |
| TruthValueWithNA |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| RowStatus | |
| TEXTUAL-CONVENTION | |
| TestAndIncr |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| lumEquipmentMIBModule | 1.3.6.1.4.1.8708.1.1.12 | The common equipment configuration MIB. - General - Subrack status - Board configuration and status - Power supply status - Fan status - Slot | ||
| lumEquipmentConfs | 1.3.6.1.4.1.8708.2.11.1 | |||
| lumEquipmentGroups | 1.3.6.1.4.1.8708.2.11.1.1 | |||
| equipmentGeneralGroup | 1.3.6.1.4.1.8708.2.11.1.1.1 | The general objects. | ||
| equipmentSubrackGroup | 1.3.6.1.4.1.8708.2.11.1.1.2 | The subrack module objects. | ||
| equipmentBoardGroup | 1.3.6.1.4.1.8708.2.11.1.1.3 | The board objects. | ||
| equipmentPowerGroup | 1.3.6.1.4.1.8708.2.11.1.1.4 | The power module objects. | ||
| equipmentFanGroup | 1.3.6.1.4.1.8708.2.11.1.1.5 | The fan module objects. | ||
| equipmentGeneralGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.6 | The equipment general objects v2. | ||
| equipmentNotificationGroup | 1.3.6.1.4.1.8708.2.11.1.1.7 | The equipment notifications. | ||
| equipmentSubrackGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.8 | The subrack module objects V2. | ||
| equipmentSubrackGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.9 | The subrack module objects V3. | ||
| equipmentBoardGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.10 | The board objects V2. | ||
| equipmentNodeGroup | 1.3.6.1.4.1.8708.2.11.1.1.11 | The node objects. | ||
| equipmentGeneralGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.12 | The equipment general objects v3. | ||
| equipmentNodeGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.13 | The node objects. | ||
| equipmentNodeGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.14 | The node objects. | ||
| equipmentSubrackGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.15 | The subrack module objects V4. | ||
| equipmentBoardGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.16 | The board objects V3. | ||
| equipmentNotificationGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.17 | The equipment notifications. | ||
| equipmentSubrackGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.18 | The subrack module objects V5. (2.2) | ||
| equipmentFanGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.19 | The fan module objects. | ||
| equipmentGeneralGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.20 | The equipment general objects v4 (3.1). | ||
| equipmentSubrackGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.21 | The subrack module objects V6. (4.0) | ||
| equipmentBoardGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.22 | The board objects V4. (4.0) | ||
| equipmentPowerGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.23 | The power module objects (4.0). | ||
| equipmentFanGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.24 | The fan module objects (4.0). | ||
| equipmentNodeGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.25 | The node objects V4 (7.0) | ||
| equipmentBoardGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.26 | The board objects V5. (7.0) | ||
| equipmentBoardGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.27 | The board objects V6. (8.0) | ||
| equipmentBoardGroupV7 | 1.3.6.1.4.1.8708.2.11.1.1.28 | The board objects V7. (9.0) | ||
| equipmentNodeGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.29 | The node objects V8 (11.0) | ||
| equipmentBoardGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.30 | The board objects V8. (12.0) | ||
| equipmentNodeGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.31 | The node objects V9 (14.0) | ||
| equipmentResourceGroup | 1.3.6.1.4.1.8708.2.11.1.1.32 | The resouce objects V1 (16.0) | ||
| equipmentSubrackGroupV7 | 1.3.6.1.4.1.8708.2.11.1.1.33 | The subrack module objects V7. (16.0) | ||
| equipmentSubrackGroupV8 | 1.3.6.1.4.1.8708.2.11.1.1.34 | The subrack module objects V8. (17.0) | ||
| equipmentBoardGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.35 | The board objects V9. (17.0) | ||
| equipmentNotificationGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.36 | The equipment notifications. | ||
| equipmentBoardGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.37 | The board objects V10. (17.0) | ||
| equipmentNodeGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.38 | The node objects V10 (18.0) | ||
| equipmentBoardGroupV11 | 1.3.6.1.4.1.8708.2.11.1.1.40 | The board objects V11. (20.0) | ||
| equipmentFanGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.41 | The fan module objects V4. (20.0) | ||
| equipmentSlotGroup | 1.3.6.1.4.1.8708.2.11.1.1.42 | The slot module objects. (20.0) | ||
| equipmentBoardGroupV12 | 1.3.6.1.4.1.8708.2.11.1.1.43 | The board objects V12. (21.0) | ||
| equipmentNodeGroupV11 | 1.3.6.1.4.1.8708.2.11.1.1.44 | The node objects V11 (21.0) | ||
| equipmentBoardGroupV13 | 1.3.6.1.4.1.8708.2.11.1.1.45 | The board objects V13. (27.0) | ||
| equipmentPowerGroupV3 | 1.3.6.1.4.1.8708.2.11.1.1.46 | The power module objects V3 (27.0). | ||
| equipmentBoardGroupV14 | 1.3.6.1.4.1.8708.2.11.1.1.47 | The board objects V14. (28.0) | ||
| equipmentSlotGroupV2 | 1.3.6.1.4.1.8708.2.11.1.1.48 | The slot module objects V2. (28.0) | ||
| equipmentSubrackGroupV9 | 1.3.6.1.4.1.8708.2.11.1.1.49 | The subrack module objects V9. (28.0) | ||
| equipmentPowerGroupV4 | 1.3.6.1.4.1.8708.2.11.1.1.50 | The power module objects V4 (28.0). | ||
| equipmentFanGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.51 | The fan module objects V5. (28.0) | ||
| equipmentGeneralGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.52 | The equipment general objects v5 (R28.0). | ||
| equipmentSubrackGroupV10 | 1.3.6.1.4.1.8708.2.11.1.1.53 | The subrack module objects V10. (29.0) | ||
| equipmentGeneralGroupV6 | 1.3.6.1.4.1.8708.2.11.1.1.54 | The equipment general objects v6 (R31.0). | ||
| equipmentOpticalModuleGroup | 1.3.6.1.4.1.8708.2.11.1.1.55 | The equipment optical module objects v6 (R31.0). | ||
| equipmentPowerGroupV5 | 1.3.6.1.4.1.8708.2.11.1.1.56 | The power module objects V5 (32.1). | ||
| lumEquipmentCompl | 1.3.6.1.4.1.8708.2.11.1.2 | |||
| lumEquipmentBasicComplV1 | 1.3.6.1.4.1.8708.2.11.1.2.1 | Basic implementation requirements for the equipment MIB. | ||
| lumEquipmentBasicComplV2 | 1.3.6.1.4.1.8708.2.11.1.2.2 | Basic implementation requirements for the equipment MIB V2. | ||
| lumEquipmentBasicComplV3 | 1.3.6.1.4.1.8708.2.11.1.2.3 | Basic implementation requirements for the equipment MIB V3. | ||
| lumEquipmentBasicComplV4 | 1.3.6.1.4.1.8708.2.11.1.2.4 | Basic implementation requirements for the equipment MIB V4. | ||
| lumEquipmentBasicComplV5 | 1.3.6.1.4.1.8708.2.11.1.2.5 | Basic implementation requirements for the equipment MIB V5. | ||
| lumEquipmentBasicComplV6 | 1.3.6.1.4.1.8708.2.11.1.2.6 | Basic implementation requirements for the equipment MIB V6. | ||
| lumEquipmentBasicComplV7 | 1.3.6.1.4.1.8708.2.11.1.2.7 | Basic implementation requirements for the equipment MIB V7. | ||
| lumEquipmentBasicComplV8 | 1.3.6.1.4.1.8708.2.11.1.2.8 | Basic implementation requirements for the equipment MIB V8. | ||
| lumEquipmentBasicComplV9 | 1.3.6.1.4.1.8708.2.11.1.2.9 | Basic implementation requirements for the equipment MIB V9. | ||
| lumEquipmentBasicComplV10 | 1.3.6.1.4.1.8708.2.11.1.2.10 | Basic implementation requirements for the equipment MIB V10. | ||
| lumEquipmentBasicComplV11 | 1.3.6.1.4.1.8708.2.11.1.2.11 | Basic implementation requirements for the equipment MIB V11. Equivalent to V10, but the notifications differ... | ||
| lumEquipmentBasicComplV12 | 1.3.6.1.4.1.8708.2.11.1.2.12 | Basic implementation requirements for the equipment MIB V12. | ||
| lumEquipmentBasicComplV13 | 1.3.6.1.4.1.8708.2.11.1.2.13 | Basic implementation requirements for the equipment MIB V13. (2.2) | ||
| lumEquipmentBasicComplV14 | 1.3.6.1.4.1.8708.2.11.1.2.14 | Basic implementation requirements for the equipment MIB V14. (2.3) | ||
| lumEquipmentBasicComplV15 | 1.3.6.1.4.1.8708.2.11.1.2.15 | Basic implementation requirements for the equipment MIB V15. (2.3.2) | ||
| lumEquipmentBasicComplV16 | 1.3.6.1.4.1.8708.2.11.1.2.16 | Basic implementation requirements for the equipment MIB V16. (3.0) | ||
| lumEquipmentBasicComplV17 | 1.3.6.1.4.1.8708.2.11.1.2.17 | Basic implementation requirements for the equipment MIB V17. (3.1) | ||
| lumEquipmentBasicComplV18 | 1.3.6.1.4.1.8708.2.11.1.2.18 | Basic implementation requirements for the equipment MIB V18. (4.0) | ||
| lumEquipmentBasicComplV19 | 1.3.6.1.4.1.8708.2.11.1.2.19 | Basic implementation requirements for the equipment MIB V19. (7.0) | ||
| lumEquipmentBasicComplV20 | 1.3.6.1.4.1.8708.2.11.1.2.20 | Basic implementation requirements for the equipment MIB V20. (8.0) | ||
| lumEquipmentBasicComplV21 | 1.3.6.1.4.1.8708.2.11.1.2.21 | Basic implementation requirements for the equipment MIB V21. (9.0) | ||
| lumEquipmentBasicComplV22 | 1.3.6.1.4.1.8708.2.11.1.2.22 | Basic implementation requirements for the equipment MIB V22. (10.0) | ||
| lumEquipmentBasicComplV23 | 1.3.6.1.4.1.8708.2.11.1.2.23 | Basic implementation requirements for the equipment MIB V23. (11.0) | ||
| lumEquipmentBasicComplV24 | 1.3.6.1.4.1.8708.2.11.1.2.24 | Basic implementation requirements for the equipment MIB V24. (12.0) | ||
| lumEquipmentBasicComplV25 | 1.3.6.1.4.1.8708.2.11.1.2.25 | Basic implementation requirements for the equipment MIB V24. (14.0) | ||
| lumEquipmentBasicComplV26 | 1.3.6.1.4.1.8708.2.11.1.2.26 | Basic implementation requirements for the equipment MIB V26. (16.0) | ||
| lumEquipmentBasicComplV27 | 1.3.6.1.4.1.8708.2.11.1.2.27 | Basic implementation requirements for the equipment MIB V26. (16.0) | ||
| lumEquipmentBasicComplV28 | 1.3.6.1.4.1.8708.2.11.1.2.28 | Basic implementation requirements for the equipment MIB V28. (17.0) | ||
| lumEquipmentBasicComplV29 | 1.3.6.1.4.1.8708.2.11.1.2.29 | Basic implementation requirements for the equipment MIB V28. (17.0) | ||
| lumEquipmentBasicComplV30 | 1.3.6.1.4.1.8708.2.11.1.2.30 | Basic implementation requirements for the equipment MIB V30. (18.0) | ||
| lumEquipmentBasicComplV31 | 1.3.6.1.4.1.8708.2.11.1.2.31 | Basic implementation requirements for the equipment MIB V31. (20.0) | ||
| lumEquipmentBasicComplV32 | 1.3.6.1.4.1.8708.2.11.1.2.32 | Basic implementation requirements for the equipment MIB V32. (21.0) | ||
| lumEquipmentBasicComplV33 | 1.3.6.1.4.1.8708.2.11.1.2.33 | Basic implementation requirements for the equipment MIB V33. (27.0) | ||
| lumEquipmentBasicComplV34 | 1.3.6.1.4.1.8708.2.11.1.2.34 | Basic implementation requirements for the equipment MIB V34. (28.0) | ||
| lumEquipmentBasicComplV35 | 1.3.6.1.4.1.8708.2.11.1.2.35 | Basic implementation requirements for the equipment MIB V35. (29.0) | ||
| lumEquipmentBasicComplV36 | 1.3.6.1.4.1.8708.2.11.1.2.36 | Basic implementation requirements for the equipment MIB V36. (31.0) | ||
| lumEquipmentBasicComplV37 | 1.3.6.1.4.1.8708.2.11.1.2.37 | Basic implementation requirements for the equipment MIB V37. (32.1) | ||
| lumEquipmentMinimalGroups | 1.3.6.1.4.1.8708.2.11.1.3 | |||
| equipmentGeneralMinimalGroupV1 | 1.3.6.1.4.1.8708.2.11.1.3.1 | The minimal general equipment MIB objects. | ||
| equipmentBoardMinimalGroupV1 | 1.3.6.1.4.1.8708.2.11.1.3.2 | The minimal board objects. | ||
| equipmentBoardMinimalGroupV2 | 1.3.6.1.4.1.8708.2.11.1.3.3 | The minimal board objects. | ||
| lumEquipmentMinimalCompl | 1.3.6.1.4.1.8708.2.11.1.4 | |||
| lumEquipmentMinimalComplV1 | 1.3.6.1.4.1.8708.2.11.1.4.1 | Minimal implementation requirements for the equipment MIB V1. | ||
| lumEquipmentMinimalComplV2 | 1.3.6.1.4.1.8708.2.11.1.4.2 | Minimal implementation requirements for the equipment MIB V2. | ||
| lumEquipmentMinimalComplV3 | 1.3.6.1.4.1.8708.2.11.1.4.3 | Minimal implementation requirements for the equipment MIB V3. | ||
| lumEquipmentMinimalComplV4 | 1.3.6.1.4.1.8708.2.11.1.4.4 | Minimal implementation requirements for the equipment MIB V4. | ||
| lumEquipmentMinimalComplV5 | 1.3.6.1.4.1.8708.2.11.1.4.5 | Minimal implementation requirements for the equipment MIB V5. | ||
| lumEquipmentMinimalComplV6 | 1.3.6.1.4.1.8708.2.11.1.4.6 | Minimal implementation requirements for the equipment MIB V6. | ||
| lumEquipmentMIBObjects | 1.3.6.1.4.1.8708.2.11.2 | |||
| equipmentGeneral | 1.3.6.1.4.1.8708.2.11.2.1 | |||
| TES equipmentGeneralTestAndIncr | 1.3.6.1.4.1.8708.2.11.2.1.1 | TestAndIncr | read-write | Protection against simultaneous access from multiple managers. See SNMPv2-TC. |
| STR equipmentGeneralMibSpecVersion | 1.3.6.1.4.1.8708.2.11.2.1.2 | DisplayString | read-write | The MIB specification version. tbd: persistent? |
| STR equipmentGeneralMibImplVersion | 1.3.6.1.4.1.8708.2.11.2.1.3 | DisplayString | read-write | The MIB implementation version. |
| DAT equipmentGeneralLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.1.4 | DateAndTime | read-only | The time when the configuration of the MIB was last changed. |
| DAT equipmentGeneralStateLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.1.5 | DateAndTime | read-only | The time when the state of the MIB was last changed. |
| U32 equipmentGeneralEquipmentSubrackTableSize | 1.3.6.1.4.1.8708.2.11.2.1.6 | Unsigned32 | read-only | Size of table |
| U32 equipmentGeneralEquipmentBoardTableSize | 1.3.6.1.4.1.8708.2.11.2.1.7 | Unsigned32 | read-only | Size of table |
| U32 equipmentGeneralEquipmentPowerTableSize | 1.3.6.1.4.1.8708.2.11.2.1.8 | Unsigned32 | read-only | Size of table |
| U32 equipmentGeneralEquipmentFanTableSize | 1.3.6.1.4.1.8708.2.11.2.1.9 | Unsigned32 | read-only | Size of table |
| U32 equipmentGeneralEquipmentSlotTableSize | 1.3.6.1.4.1.8708.2.11.2.1.10 | Unsigned32 | read-only | Size of table |
| U32 equipmentGeneralEquipmentOpticalModuleTableSize | 1.3.6.1.4.1.8708.2.11.2.1.11 | Unsigned32 | read-only | Size of table |
| equipmentSubrackList | 1.3.6.1.4.1.8708.2.11.2.2 | |||
| equipmentSubrackTable | 1.3.6.1.4.1.8708.2.11.2.2.1 | not-accessible | The subrack list. | |
| equipmentSubrackEntry | 1.3.6.1.4.1.8708.2.11.2.2.1.1 | not-accessible | An entry in the subrack list. | |
| U32 equipmentSubrackIndex | 1.3.6.1.4.1.8708.2.11.2.2.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each subrack entry. |
| STR equipmentSubrackName | 1.3.6.1.4.1.8708.2.11.2.2.1.1.2 | MgmtNameString | read-only | The name of the subrack, for example 'sub1' where the number indicates the subrack number. |
| SUB equipmentSubrackSubrack | 1.3.6.1.4.1.8708.2.11.2.2.1.1.3 | SubrackNumber | read-create | The number of the subrack. |
| STR equipmentSubrackDescr | 1.3.6.1.4.1.8708.2.11.2.2.1.1.4 | DisplayString | read-write | User configurable label. |
| U32 equipmentSubrackInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.2.1.1.5 | Unsigned32 | read-only | The row in the invPhysTable for this subrack. Set to 0 if not known. |
| FAU equipmentSubrackAllFanUnitsFailed | 1.3.6.1.4.1.8708.2.11.2.2.1.1.6 | FaultStatus | read-only | All fan units in a subrack have failed. A(ctivation): fanUnitFailed active for all fans within a subrack. D(e-activiation): fanUnitFailed cleared for one fan unit. |
| ROW equipmentSubrackRowStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.7 | RowStatus | read-create | SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| EQU equipmentSubrackExpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.8 | EquipmentSubrackType | read-write | The expected subrack type. |
| EQU equipmentSubrackActualType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.9 | EquipmentSubrackType | read-only | The actual subrack type. If an unexpected subrack has been detected this variable can be used to see what type of subrack has been detected. |
| FAU equipmentSubrackUnexpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.10 | FaultStatus | read-only | A type of subrack not matching the expected type is present. A: A subrack with type different from the expected type is present (even if the subrack is not activated). D: The type matches the expected or no subrack is present. |
| I32 equipmentSubrackTemp | 1.3.6.1.4.1.8708.2.11.2.2.1.1.11 | Integer32 | read-only | The temperature in the subrack in 0.1 degrees centigrade. |
| FAU equipmentSubrackTempHighExceeded | 1.3.6.1.4.1.8708.2.11.2.2.1.1.12 | FaultStatus | read-only | The threshold for environmental temperature in the subrack is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. |
| I32 equipmentSubrackTempThreshold | 1.3.6.1.4.1.8708.2.11.2.2.1.1.13 | Integer32 | read-write | The threshold for temperature alarm in the subrack in 0.1 degrees centigrade. |
| FAU equipmentSubrackDataChanged | 1.3.6.1.4.1.8708.2.11.2.2.1.1.14 | FaultStatus | read-only | The subrack data (dipswitches for subrackId and/or system mode) has been changed. Changing this data might affect the system behaviour after the next restart. A: The subrack data has been changed since startup D: The subrack data is changed back to the value read at startup, or the system is restarted. |
| FAU equipmentSubrackSystemModeSet | 1.3.6.1.4.1.8708.2.11.2.2.1.1.15 | FaultStatus | read-only | The value read from the system mode dipswitches at startup of the CU was diffrent from 0. This will affect the behaviour of the system. If the lowest bit is set, the backup is read from the TUs - useful at CU replacement. A: The system mode is different from 0 at startup. D: The system mode is 0 at startup. |
| U32 equipmentSubrackEffectiveSystemMode | 1.3.6.1.4.1.8708.2.11.2.2.1.1.16 | Unsigned32 | read-only | The value of the system mode dipswitches read at startup. This value determines the system behaviour. |
| U32 equipmentSubrackCurrentSystemMode | 1.3.6.1.4.1.8708.2.11.2.2.1.1.17 | Unsigned32 | read-only | The current value of the system mode dipswitches. Will be used at the next restart. |
| INT equipmentSubrackAdminStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.18 | INTEGER | read-write | The administrative state of the subrack. down - This subrack should not be monitored. Suppresses alarms. up - The subrack should be monitored. |
| INT equipmentSubrackOperStatus | 1.3.6.1.4.1.8708.2.11.2.2.1.1.19 | INTEGER | read-only | The operational state of the subrack. notPresent - The subrack is not available. down - The subrack remains in the 'down'-state when adminStatus is set to 'down'. up - The subrack is active and monitored. |
| OBJ equipmentSubrackObjectProperty | 1.3.6.1.4.1.8708.2.11.2.2.1.1.20 | ObjectProperty | read-only | Property mask. |
| U32 equipmentSubrackShelfLength | 1.3.6.1.4.1.8708.2.11.2.2.1.1.21 | Unsigned32 | read-write | Length of the half-height slot divider shelf. To be manually entered by the user. A value of 0 is interpreted as 'not yet defined by user'. |
| FAU equipmentSubrackLANModuleMissing | 1.3.6.1.4.1.8708.2.11.2.2.1.1.22 | FaultStatus | read-only | The subrack LAN/DCN module is missing. A(ctivation): LAN/DCN module disconnected from subrack for more than 2 seconds. D(e-activiation): LAN/DCN module connected to subrack for more than 2 seconds. |
| FIR equipmentSubrackExpectedFirstPbSlot | 1.3.6.1.4.1.8708.2.11.2.2.1.1.23 | FirstPbSlot | read-write | The lowest slot number where it is possible to configure a passive board. Automatically configured to the actual value supported by hardware if the hardware is present on subrack configuration. If no hardware is present at configuration time, this value is set to 'undefined' until changed by the user. The 'undefined' value allows passive board configuration in the same slots as the highest possible firstPbSlot setting of the subrack type. |
| FIR equipmentSubrackActualFirstPbSlot | 1.3.6.1.4.1.8708.2.11.2.2.1.1.24 | FirstPbSlot | read-only | The actual lowest slot number where it is possible to configure a passive board. When no subrack hardware is present, this value is 'undefined'. |
| FAU equipmentSubrackFirstPbSlotMismatch | 1.3.6.1.4.1.8708.2.11.2.2.1.1.25 | FaultStatus | read-only | The expected first passive slot allows more passive boards than the hardware supports. A(ctivation): A subrack and control unit combination which supports fewer passive boards than configured is present. D(e-activiation): A subrack and control unit combination which supports the current configuration is present. |
| STR equipmentSubrackAid | 1.3.6.1.4.1.8708.2.11.2.2.1.1.26 | DisplayString | read-only | The access identifier (AID) of the product. The format is according to GR-833. |
| STR equipmentSubrackPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.2.1.1.27 | DisplayString | read-only | The Physical location of the product. The format is according to GR-833. |
| STR equipmentSubrackChangeExpectedType | 1.3.6.1.4.1.8708.2.11.2.2.1.1.28 | CommandString | read-only | Command to change expected type, used when upgrading subrack to a new version, e.g TM3000 to TM3000/II |
| equipmentBoardList | 1.3.6.1.4.1.8708.2.11.2.3 | |||
| equipmentBoardTable | 1.3.6.1.4.1.8708.2.11.2.3.1 | not-accessible | The board list. | |
| equipmentBoardEntry | 1.3.6.1.4.1.8708.2.11.2.3.1.1 | not-accessible | An entry in the board list. One entry for each slot. | |
| U32 equipmentBoardIndex | 1.3.6.1.4.1.8708.2.11.2.3.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each board entry. |
| STR equipmentBoardName | 1.3.6.1.4.1.8708.2.11.2.3.1.1.2 | MgmtNameString | read-only | The name of the board, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the board is present and the second number in which slot. |
| EQU equipmentBoardExpectedType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.3 | EquipmentBoardType | read-create | The expected board type. |
| EQU equipmentBoardActualType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.4 | EquipmentBoardType | read-only | The actual board type. If an unexpected board has been detected this variable can be used to see what type of board has been detected. |
| STR equipmentBoardDescr | 1.3.6.1.4.1.8708.2.11.2.3.1.1.5 | DisplayString | read-write | User configurable label. |
| SUB equipmentBoardSubrack | 1.3.6.1.4.1.8708.2.11.2.3.1.1.6 | SubrackNumber | read-create | The number of the subrack where the board is located. |
| SLO equipmentBoardSlot | 1.3.6.1.4.1.8708.2.11.2.3.1.1.7 | SlotNumber | read-create | The slot where the board is located. |
| I32 equipmentBoardTemp | 1.3.6.1.4.1.8708.2.11.2.3.1.1.8 | Integer32 | read-only | The temperature on the board in 0.1 degrees centigrade. |
| U32 equipmentBoardInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.3.1.1.9 | Unsigned32 | read-only | The row in the invPhysTable for this board. Set to 0 if not known. |
| INT equipmentBoardLedTest | 1.3.6.1.4.1.8708.2.11.2.3.1.1.10 | INTEGER | read-write | LED test for the board. off - Normal operation. on - Light all leds. |
| NUM equipmentBoardAdminStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.11 | BoardOrInterfaceAdminStatus | read-write | The administrative state of the board. down - The board should be inactive. Alarms are suppressed. service - The board is activated but alarms are suppressed. Intended for use during service or re-configuration. When service is concluded adminStatus should be set to 'up' again. up - The board should be activated when it becomes available. Alarms are not suppressed. |
| NUM equipmentBoardOperStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.12 | BoardOrInterfaceOperStatus | read-only | The operational state of the board. notPresent - The board is not available. down - The board remains in the 'down'-state when adminStatus is set to 'down' or if there is a fault preventing it from going to the 'up'-state. up - The board is operational. The operational state becomes 'up' when adminStatus is set to 'up' unless there are faults detected. |
| DAT equipmentBoardLastChangeTime | 1.3.6.1.4.1.8708.2.11.2.3.1.1.13 | DateAndTime | read-only | The time when the operational state of the board entry was last changed. |
| ROW equipmentBoardRowStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.14 | RowStatus | read-create | SNMP administrivia. Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| FAU equipmentBoardMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.15 | FaultStatus | read-only | There is no board present in a slot where the expected board type is defined. Suppressed if administrative status is down. A(ctivation): Card out of place (COP) indication active for more than 2 seconds. D(e-activation): Card out of place (COP) indication inactive for more than 2 seconds. |
| FAU equipmentBoardUnexpectedType | 1.3.6.1.4.1.8708.2.11.2.3.1.1.16 | FaultStatus | read-only | A type of board not matching the expected type is present and active in the same slot. Since the default value for the type is 'undefined' this alarm is raised when inserting an unconfigured board. A: A board with type different from the expected type is present in the slot (even if the board is not activated). D: The type matches the expected or no board is present. |
| FAU equipmentBoardTempHighExceeded | 1.3.6.1.4.1.8708.2.11.2.3.1.1.17 | FaultStatus | read-only | The threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. |
| FAU equipmentBoardCommunicationFailure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.18 | FaultStatus | read-only | Communication between the control unit and the the board has failed completely. A: There is a board present but there has been no communication established within 20 seconds. D: Communication is established. |
| FAU equipmentBoardInterworkFailed | 1.3.6.1.4.1.8708.2.11.2.3.1.1.19 | FaultStatus | read-only | Communication between the control unit and the board has failed due to incompatible software. A: The control unit and the board have in-compatible software. D: The control unit and the board have compatible software. |
| FAU equipmentBoardSecondaryPowerFailed | 1.3.6.1.4.1.8708.2.11.2.3.1.1.20 | FaultStatus | read-only | Secondary DC power (1.8 or 2.5 V) failure. A: The secondary DC power on the board has failed. D: The secondary DC power is present. Note: If primary power fails a 'communicationFailure' alarm will most likely be raised instead. |
| FAU equipmentBoardVitalDataMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.21 | FaultStatus | read-only | Product data vital for the safe operation of the equipment is missing. A: Product data missing. D: Product data present. |
| FAU equipmentBoardNonVitalDataMissing | 1.3.6.1.4.1.8708.2.11.2.3.1.1.22 | FaultStatus | read-only | Administrative product data is missing. A: Product data missing. D: Product data present. |
| FAU equipmentBoardUnderMaintenance | 1.3.6.1.4.1.8708.2.11.2.3.1.1.23 | FaultStatus | read-only | The board is undergoing maintenance, adminStatus is set to service. A: AdminStatus is set to service. D: AdminStatus is set to another value. |
| I32 equipmentBoardTempThreshold | 1.3.6.1.4.1.8708.2.11.2.3.1.1.24 | Integer32 | read-write | The threshold for temperature alarm on the board in 0.1 degrees centigrade. |
| FAU equipmentBoardSwVersionMismatch | 1.3.6.1.4.1.8708.2.11.2.3.1.1.25 | FaultStatus | read-only | The version of the board SW does not match the SW version running och the main CU. For versions to match, the release number, e.g. 'r2b', must be the same. The build number is not required to be the same. Examples: r2b-2 matches r2b-1, r2b-2, ..., r2b- r2b- does NOT match r2a- A: The board is started with as SW version other than the main CU. D: The board, or main CU, is restarted with matching SW versions. |
| OBJ equipmentBoardObjectProperty | 1.3.6.1.4.1.8708.2.11.2.3.1.1.26 | ObjectProperty | read-only | Property mask. |
| FAU equipmentBoardTempLow | 1.3.6.1.4.1.8708.2.11.2.3.1.1.27 | FaultStatus | read-only | The low threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated low threshold. D: Temperature is 0.5 degrees centigrade above the associated threshold. |
| FAU equipmentBoardTempVeryHigh | 1.3.6.1.4.1.8708.2.11.2.3.1.1.28 | FaultStatus | read-only | The very high threshold for environmental temperature on the board is exceeded. A: The temperature exceeds the associated threshold. D: Temperature is 0.5 degrees centigrade below the associated threshold. |
| STR equipmentBoardReconfigure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.29 | CommandString | read-only | Applicable for cu, cu2osc, cuSfp, cuSfpii and voa8chii. Reconfigure cu or cu2osc board to cuSfp. Reconfigure cu2osc or cuSfp board to cuSfpii. Reconfigure older CU-board to cuSfpiii. Reconfigure voa8chii to voa8chsfp. Reconfigure tpq10Gfec to tpq10gfeci or vise versa Reconfigure tpq10GfecReg to tpq10gfecregi or vise versa |
| INT equipmentBoardLedStatus | 1.3.6.1.4.1.8708.2.11.2.3.1.1.30 | INTEGER | read-only | LED status for the board. This is primarily intended for debugging |
| STR equipmentBoardModuleInfo | 1.3.6.1.4.1.8708.2.11.2.3.1.1.31 | DisplayString | read-only | Information (for example firmware and serial number) about the module. |
| FAU equipmentBoardNewSwActivatedButNotRestarted | 1.3.6.1.4.1.8708.2.11.2.3.1.1.32 | FaultStatus | read-only | A new SW version on the board has been activated, but the board has not been rebooted. This means that after the next reboot, a new SW will be active. For the main CU, this also means that the backup will be read from a new directory. A: A new SW has been activated but the board has not been rebooted within 12 hours. D: The board is rebooted or the SW is reverted. |
| FAU equipmentBoardLowTemperature | 1.3.6.1.4.1.8708.2.11.2.3.1.1.33 | FaultStatus | read-only | The environmental temperature on the board is below startuptemperature (+3 centigrade). A: The temperature is below +3 degrees centigrade. D: Temperature has increased to +5 degrees centigrade. |
| I32 equipmentBoardTempLowThreshold | 1.3.6.1.4.1.8708.2.11.2.3.1.1.34 | Integer32 | read-only | The threshold for low temperature alarm on the board in 0.1 degrees centigrade. |
| STR equipmentBoardAdditionalInfo | 1.3.6.1.4.1.8708.2.11.2.3.1.1.35 | DisplayString | read-only | Additional information about the board, e.g. FPGA revision. |
| FAU equipmentBoardBootError | 1.3.6.1.4.1.8708.2.11.2.3.1.1.36 | FaultStatus | read-only | The card fails to boot. A: The card fails to boot. D: The card boot successfully. |
| FAU equipmentBoardHardwareError | 1.3.6.1.4.1.8708.2.11.2.3.1.1.37 | FaultStatus | read-only | A hardware error occured. A: A hardware error occured. D: No hardware error. |
| FAU equipmentBoardLowDiskSpace | 1.3.6.1.4.1.8708.2.11.2.3.1.1.38 | FaultStatus | read-only | Low disk space in the board. A: Not enough disk space. D: Disk space is enough. |
| FAU equipmentBoardClockDrift | 1.3.6.1.4.1.8708.2.11.2.3.1.1.39 | FaultStatus | read-only | Clock frequency is out of range. A: Clock frequency out is out of range. D: Clock frequency is in range. |
| INT equipmentBoardPostponeFwUpgrade | 1.3.6.1.4.1.8708.2.11.2.3.1.1.40 | INTEGER | read-write | Postpone activation of new traffic firmware when the board software is upgraded next time. If no firmware changes are available when upgrading this option will not have any effect. |
| STR equipmentBoardActivatePendingFwCommand | 1.3.6.1.4.1.8708.2.11.2.3.1.1.41 | CommandString | read-only | Command to activate a pending firmware upgrade. |
| FAU equipmentBoardFwActivationPending | 1.3.6.1.4.1.8708.2.11.2.3.1.1.42 | FaultStatus | read-only | Firmware activation has been postponed in a previous software upgrade. |
| FAU equipmentBoardFeatureNotSupported | 1.3.6.1.4.1.8708.2.11.2.3.1.1.43 | FaultStatus | read-only | A configuration request has failed since the chosen feature is not supported by the active firmware. |
| FAU equipmentBoardFwReloadNeeded | 1.3.6.1.4.1.8708.2.11.2.3.1.1.44 | FaultStatus | read-only | The traffic HW has been programmed by a version of the system that does not offer a supported upgrade path to the currently running version. This typically happens after a downgrade or rollback of the SW. The state of the traffic HW is formally unknown and further changes to the traffic configuration cannot be guaranteed. A reset of the traffic unit is recommended. This will cause a short traffic hit. |
| FAU equipmentBoardFwContextUnknown | 1.3.6.1.4.1.8708.2.11.2.3.1.1.45 | FaultStatus | read-only | The running version of the SW cannot recover the settings of the traffic HW/FW. The state of the traffic HW is unknown. A reset of the traffic unit is recommended. This will cause a short traffic hit. |
| INT equipmentBoardBoardVariant | 1.3.6.1.4.1.8708.2.11.2.3.1.1.46 | INTEGER | read-write | Determines board configuration. dualMuxponderProt - 2x Muxponder with protection hexTransponder - 6x Transponder tripleMuxponderProt - 3x Muxponder with protection quadTransponderProt - 4x Transponder with protection notApplicable - 2147483647 is used to indicate that the attribute is not used on the board. |
| INT equipmentBoardCabinetConnectivity | 1.3.6.1.4.1.8708.2.11.2.3.1.1.47 | INTEGER | read-write | Monitor Cabinet status if enabled. Alarm is raised if connection is lost. |
| FAU equipmentBoardCabinetConnectionFailure | 1.3.6.1.4.1.8708.2.11.2.3.1.1.48 | FaultStatus | read-only | Connection to the cabinet has failed. |
| INT equipmentBoardOperationalVariant | 1.3.6.1.4.1.8708.2.11.2.3.1.1.49 | INTEGER | read-create | Operational Variant mode of board, Normal or OpenFlow Controlled. |
| STR equipmentBoardAid | 1.3.6.1.4.1.8708.2.11.2.3.1.1.50 | DisplayString | read-only | The access identifier (AID) of the product. The format is according to GR-833. |
| STR equipmentBoardPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.3.1.1.51 | DisplayString | read-only | The Physical location of the product. The format is according to GR-833. |
| equipmentPowerList | 1.3.6.1.4.1.8708.2.11.2.4 | |||
| equipmentPowerTable | 1.3.6.1.4.1.8708.2.11.2.4.1 | not-accessible | The list of power supplies. | |
| equipmentPowerEntry | 1.3.6.1.4.1.8708.2.11.2.4.1.1 | not-accessible | An entry in the power supply list. | |
| U32 equipmentPowerIndex | 1.3.6.1.4.1.8708.2.11.2.4.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each power module. |
| STR equipmentPowerName | 1.3.6.1.4.1.8708.2.11.2.4.1.1.2 | DisplayString | read-only | The name of the power module. For example 'pow:1:2'. |
| SUB equipmentPowerSubrack | 1.3.6.1.4.1.8708.2.11.2.4.1.1.3 | SubrackNumber | read-only | The number of the subrack in which the power module is present. |
| U32 equipmentPowerSlot | 1.3.6.1.4.1.8708.2.11.2.4.1.1.4 | Unsigned32 | read-only | The number of the slot in which the power module is present. |
| INT equipmentPowerType | 1.3.6.1.4.1.8708.2.11.2.4.1.1.5 | INTEGER | read-only | The the type of power module. ac - AC power supply (230V). dc - DC power supply (48V). |
| U32 equipmentPowerInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.4.1.1.9 | Unsigned32 | read-only | The row in the invPhysTable for this power module. Set to 0 if not known. |
| INT equipmentPowerAdminStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.10 | INTEGER | read-write | The administrative state of the power module. down - This power module is not monitored. Suppresses alarms. up - The power module is monitored. |
| INT equipmentPowerOperStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.11 | INTEGER | read-only | The operational state of the power module. notPresent - The power module is not present. down - The module is not active or there are faults preventing it from going to the 'up'-state. up - The module is operational. |
| ROW equipmentPowerRowStatus | 1.3.6.1.4.1.8708.2.11.2.4.1.1.12 | RowStatus | read-write | Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| FAU equipmentPowerACPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.13 | FaultStatus | read-only | AC power supply failed (230 V). A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| FAU equipmentPowerDCPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.14 | FaultStatus | read-only | DC power supply failed (48 V). A: Active HW indication. D: Inactive HW indication. |
| FAU equipmentPowerTemperatureHigh | 1.3.6.1.4.1.8708.2.11.2.4.1.1.15 | FaultStatus | read-only | The built-in temperature monitoring of the power module thinks it is too hot. A: Active HW indication. D: Inactive HW indication. |
| FAU equipmentPowerModuleMissing | 1.3.6.1.4.1.8708.2.11.2.4.1.1.16 | FaultStatus | read-only | The power module is not available. A: Active HW indication. D: Inactive HW indication. |
| OBJ equipmentPowerObjectProperty | 1.3.6.1.4.1.8708.2.11.2.4.1.1.17 | ObjectProperty | read-only | Property mask. |
| ALA equipmentPowerDCPowerFailedSeverity | 1.3.6.1.4.1.8708.2.11.2.4.1.1.18 | AlarmPerceivedSeverity | read-write | The severity of DC Power failed alarm. |
| STR equipmentPowerAid | 1.3.6.1.4.1.8708.2.11.2.4.1.1.19 | DisplayString | read-only | The access identifier (AID) of the product. The format is according to GR-833. |
| STR equipmentPowerPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.4.1.1.20 | DisplayString | read-only | The Physical location of the product. The format is according to GR-833. |
| FAU equipmentPowerPowerFailed | 1.3.6.1.4.1.8708.2.11.2.4.1.1.21 | FaultStatus | read-only | Power supply failed. A: Active HW indication. D: Inactive HW indication. |
| equipmentFanList | 1.3.6.1.4.1.8708.2.11.2.5 | |||
| equipmentFanTable | 1.3.6.1.4.1.8708.2.11.2.5.1 | not-accessible | The list of fan modules. | |
| equipmentFanEntry | 1.3.6.1.4.1.8708.2.11.2.5.1.1 | not-accessible | An entry in the fan module list. | |
| U32 equipmentFanIndex | 1.3.6.1.4.1.8708.2.11.2.5.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each fan module. |
| STR equipmentFanName | 1.3.6.1.4.1.8708.2.11.2.5.1.1.2 | DisplayString | read-only | The name of the fan module. For example 'fan:1:2', where the first number indicates the subrack and the second number the fan slot. |
| SUB equipmentFanSubrack | 1.3.6.1.4.1.8708.2.11.2.5.1.1.3 | SubrackNumber | read-only | The number of the subrack in which the fan module is present. |
| U32 equipmentFanSlot | 1.3.6.1.4.1.8708.2.11.2.5.1.1.4 | Unsigned32 | read-only | The number of the fan-slot in which the fan module is present. |
| U32 equipmentFanInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.11.2.5.1.1.5 | Unsigned32 | read-only | The row in the invPhysTable for this fan module. Set to 0 if not known. |
| INT equipmentFanAdminStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.6 | INTEGER | read-write | The administrative state of the fan module. down - This fan module should not be monitored. Suppresses alarms. Useful if a subrack has only one fan for some reason. up - The fan module should be monitored. |
| INT equipmentFanOperStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.7 | INTEGER | read-only | The operational state of the fan module. Note: It is not possible to distinguish between a missing fan and a failed fan. Therefore 'notPresent' is currently not used. down - The fan module is not de-activated or not present or there are faults preventing it from going to the 'up'-state. up - The fan module is active and monitored. |
| ROW equipmentFanRowStatus | 1.3.6.1.4.1.8708.2.11.2.5.1.1.8 | RowStatus | read-write | Manages creation and deletion of conceptual rows. See also SNMPv2-TC. |
| FAU equipmentFanUnitFailed | 1.3.6.1.4.1.8708.2.11.2.5.1.1.9 | FaultStatus | read-only | The fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| FAU equipmentFanMainUnitFailed | 1.3.6.1.4.1.8708.2.11.2.5.1.1.10 | FaultStatus | read-only | The main fan module has failed or is absent. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| OBJ equipmentFanObjectProperty | 1.3.6.1.4.1.8708.2.11.2.5.1.1.11 | ObjectProperty | read-only | Property mask. |
| FAU equipmentFanFanFault | 1.3.6.1.4.1.8708.2.11.2.5.1.1.12 | FaultStatus | read-only | The Fan malfunction or fan speed differs from the set speed. A(ctivation): Active HW indication. D(e-activation): Inactive HW indication. |
| STR equipmentFanAid | 1.3.6.1.4.1.8708.2.11.2.5.1.1.13 | DisplayString | read-only | The access identifier (AID) of the product. The format is according to GR-833. |
| STR equipmentFanPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.5.1.1.14 | DisplayString | read-only | The Physical location of the product. The format is according to GR-833. |
| lumentisEquipmentNotifications | 1.3.6.1.4.1.8708.2.11.2.6 | |||
| equipmentNotifyPrefix | 1.3.6.1.4.1.8708.2.11.2.6.0 | |||
| NTF equipmentBoardRowStatusActive | 1.3.6.1.4.1.8708.2.11.2.6.0.1 | Sent when a board is added to the configuration. | ||
| NTF equipmentBoardRowStatusDestroy | 1.3.6.1.4.1.8708.2.11.2.6.0.2 | Sent when a board is removed from the configuration. | ||
| NTF equipmentBoardRowStatusInserted | 1.3.6.1.4.1.8708.2.11.2.6.0.3 | Sent when a board is physically inserted. | ||
| NTF equipmentBoardRowStatusRemoved | 1.3.6.1.4.1.8708.2.11.2.6.0.4 | Sent when a board is physically removed. | ||
| NTF equipmentBoardRowStatusDeleted | 1.3.6.1.4.1.8708.2.11.2.6.0.5 | Sent when a board is deleted from the configuration. | ||
| equipmentNode | 1.3.6.1.4.1.8708.2.11.2.7 | |||
| INT equipmentNodeLedTest | 1.3.6.1.4.1.8708.2.11.2.7.1 | INTEGER | read-write | LED test for the network element. off - Normal operation. on - Light all leds. |
| INT equipmentNodeIcnRedundancyMode | 1.3.6.1.4.1.8708.2.11.2.7.2 | INTEGER | read-write | Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not. disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop. ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. ring - Redundantly connected in a ring. |
| INT equipmentNodeMemoryProfile | 1.3.6.1.4.1.8708.2.11.2.7.3 | INTEGER | read-only | Indicates whether memory profilation shall be done or not. disabled - No memory profile enabled - Memory profile done |
| INT equipmentAllowDummyPassiveSlots | 1.3.6.1.4.1.8708.2.11.2.7.4 | INTEGER | read-write | This option is applicable for TM-3000 subracks only. Normally passive boards can only be created in slots 13-22. Enabling this options allows the user to create full-size passive board objects in slot 2-12 as well. Note, however, that supervision of board presence and reading of board inventory is NOT possible in slot 2-12. Also note that half-size boards, like ad1AB, are not allowed in slots 2-12. disabled - Passive boards NOT allowed in slots 2-12. enabled - Allow full-size passive boards objects in slot 2-12. |
| INT equipmentNodeManagementVlan | 1.3.6.1.4.1.8708.2.11.2.7.5 | INTEGER | read-write | Indicates if VLAN is available (via DCN for nodes with cu) or not. off - No bridging of VLAN. (mgmtVlan off in node) bridge2dcn - VLAN is bridged to DCN. (mgmtVlan on in node, used for cu) on - mgmtVlan is on, used for culess |
| INT equipmentNodeMgmtVlanPrivacy | 1.3.6.1.4.1.8708.2.11.2.7.6 | INTEGER | read-write | Set Mgmt Vlan privacy. Setting is for main subrack in node. Boards affected (in R14.0) is gbeMxp10GFEC, msMxp10G, gbe10Emxp10G and gbe22Emxp10G. isolated - privacy enabled. Not possible to communicate between boards nor ports. In slave subrack setting is only on ports, not boards community - privacy disabled. It is possible to communicate between both boards and ports. |
| INT equipmentNodeDcnRedundancyMode | 1.3.6.1.4.1.8708.2.11.2.7.7 | INTEGER | read-write | Indicates whether the DCN ports on a CU, DCN1 and DCN2, can be connected in a redundant manner or not. disabled - Non-redundant DCN connection. Both DCN ports are enable for forwarding. Note: Connecting both DCN ports to the same ethernet switch will cause a loop. enabled - Redundant DCN connection. Only one DCN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically. disabled - Non-redundant connection. enabled - Redundantly connected through a hub. |
| INT equipmentNodeProxyArp | 1.3.6.1.4.1.8708.2.11.2.7.8 | INTEGER | read-write | Indicates if the Proxy ARP functionality is used. Using Proxy ARP simplifies the IP-address allocation and minimizes the use of different subnets in the network. disabled - Proxy ARP function disabled. The nodes must be in different subnets and PPP links use routing between the nodes. enabled - Proxy ARP function enabled. All nodes can be in the same IP-subnet and PPP links do not require routing between the nodes. The Gateway node/Gateway Network Element (GNE) act as router. |
| equipmentResource | 1.3.6.1.4.1.8708.2.11.2.8 | |||
| U32 equipmentResourceNumberOfBoards | 1.3.6.1.4.1.8708.2.11.2.8.1 | Unsigned32 | read-only | The number of boards, active and passive, currently in use in this system |
| U32 equipmentResourceMaxNumberOfBoards | 1.3.6.1.4.1.8708.2.11.2.8.2 | Unsigned32 | read-only | The maximum number of boards, active and passive, that is supported by the embedded software of this system |
| U32 equipmentResourceNumberOfActiveBoards | 1.3.6.1.4.1.8708.2.11.2.8.3 | Unsigned32 | read-only | The number of active boards running on this system |
| U32 equipmentResourceMaxNumberOfActiveBoards | 1.3.6.1.4.1.8708.2.11.2.8.4 | Unsigned32 | read-only | The maximum number of active boards that is supported by the embedded software of this system. |
| equipmentSlot | 1.3.6.1.4.1.8708.2.11.2.9 | |||
| equipmentSlotTable | 1.3.6.1.4.1.8708.2.11.2.9.1 | not-accessible | The slot list. | |
| equipmentSlotEntry | 1.3.6.1.4.1.8708.2.11.2.9.1.1 | not-accessible | An entry in the slot list. One entry for each slot. | |
| U32 equipmentSlotIndex | 1.3.6.1.4.1.8708.2.11.2.9.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each slot entry. |
| STR equipmentSlotName | 1.3.6.1.4.1.8708.2.11.2.9.1.1.2 | MgmtNameString | read-only | The name of the slot, for example 'tpmr2500:1:2' where the first number indicates in which sub-rack the slot is present and the second number in which slot. |
| SUB equipmentSlotSubrack | 1.3.6.1.4.1.8708.2.11.2.9.1.1.3 | SubrackNumber | read-only | The number of the subrack in which the slot is present. |
| SLO equipmentSlotSlot | 1.3.6.1.4.1.8708.2.11.2.9.1.1.4 | SlotNumber | read-only | The slot number. |
| ADM equipmentSlotAdminStatus | 1.3.6.1.4.1.8708.2.11.2.9.1.1.5 | AdminStatus | read-write | The administrative state of the slot. down - The slot is not monitored. up - The interface should be activated. |
| INT equipmentSlotUsageState | 1.3.6.1.4.1.8708.2.11.2.9.1.1.6 | INTEGER | read-only | Tells if the slot is used or not. used - Slot is used. notUsed - Slot is not used. |
| FAU equipmentSlotEmptySlot | 1.3.6.1.4.1.8708.2.11.2.9.1.1.7 | FaultStatus | read-only | Slot is empty, alarm only applicable for systems with mendatory slot usage A: Slot is empty. D: No empty slot. |
| TRU equipmentSlotEquipped | 1.3.6.1.4.1.8708.2.11.2.9.1.1.8 | TruthValueWithNA | read-only | Is the entity equipped. |
| STR equipmentSlotAid | 1.3.6.1.4.1.8708.2.11.2.9.1.1.9 | DisplayString | read-only | The access identifier (AID) of the slot. The format is according to GR-833. |
| STR equipmentSlotPhysicalLocation | 1.3.6.1.4.1.8708.2.11.2.9.1.1.10 | DisplayString | read-only | The physical location of the slot. The format is according to GR-833. |
| equipmentOpticalModuleList | 1.3.6.1.4.1.8708.2.11.2.10 | |||
| equipmentOpticalModuleTable | 1.3.6.1.4.1.8708.2.11.2.10.1 | not-accessible | The module list. | |
| equipmentOpticalModuleEntry | 1.3.6.1.4.1.8708.2.11.2.10.1.1 | not-accessible | An entry in the module list. | |
| U32 equipmentOpticalModuleIndex | 1.3.6.1.4.1.8708.2.11.2.10.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each entry. |
| EQU equipmentOpticalModuleHostBoardType | 1.3.6.1.4.1.8708.2.11.2.10.1.1.2 | EquipmentBoardType | read-only | The actual board type hosting the optical module. |
| STR equipmentOpticalModuleType | 1.3.6.1.4.1.8708.2.11.2.10.1.1.3 | MgmtNameString | read-only | The type of optical module, for example monitor, switch, wss, amp etc |
| STR equipmentOpticalModuleName | 1.3.6.1.4.1.8708.2.11.2.10.1.1.4 | MgmtNameString | read-only | The management name of the interface, for example 'module:[HostBoardType]:[ moduleType]:[subrack]:[slot]'. |
| SUB equipmentOpticalModuleSubrack | 1.3.6.1.4.1.8708.2.11.2.10.1.1.5 | SubrackNumber | read-only | The number of the subrack where the module is located. |
| SLO equipmentOpticalModuleSlot | 1.3.6.1.4.1.8708.2.11.2.10.1.1.6 | SlotNumber | read-only | The number of the slot where the module is located. |
| STR equipmentOpticalModuleFirmwareVersion | 1.3.6.1.4.1.8708.2.11.2.10.1.1.7 | DisplayString | read-only | Firmware version of the module. |
| STR equipmentOpticalModuleSerialNumber | 1.3.6.1.4.1.8708.2.11.2.10.1.1.8 | DisplayString | read-only | Serial number of the module. |
| TRU equipmentOpticalModuleWarmingUpState | 1.3.6.1.4.1.8708.2.11.2.10.1.1.9 | TruthValueWithNA | read-only | Module is warming up, the optics has not reached a stable state. True: Module is warming up. False: Module is ready and optics have reached stable state. |
| FAU equipmentOpticalModuleFailure | 1.3.6.1.4.1.8708.2.11.2.10.1.1.10 | FaultStatus | read-only | The module is experiencing a failure. A(ctivation): The module has failed D(e-activation): The module is OK again |
RFC description
Manages common equipment configuration including subrack, board, power supply, and fan status.