LUM-EQUIPMENT-MIB :: equipmentNodeIcnRedundancyMode

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LUM-EQUIPMENT-MIB › equipmentNodeIcnRedundancyMode

equipmentNodeIcnRedundancyMode

Module: LUM-EQUIPMENT-MIB

OID (symbolic): LUM-EQUIPMENT-MIB::equipmentNodeIcnRedundancyMode

OID (numeric): 1.3.6.1.4.1.8708.2.11.2.7.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Indicates whether the internal communication network between sub-racks, ICN3 and ICN4, can be connected in a redundant manner or not.

disabled - Non-redundant ICN connection. Both ICN ports are enable for forwarding. Note: Connecting both ICN ports to the same internal switch will cause a loop.

ring - Redundant ICN connection. Only one ICN port at a time is enabled for forwarding even if both are physically connected and both links are up. Note: The port that is first connected will be used for forwarding and if disconnected, the other port will be enabled automatically.

disabled - Non-redundant connection.

ring - Redundantly connected in a ring.

What is equipmentNodeIcnRedundancyMode?

Controls whether the inter-subrack internal communication network (ICN) ports are connected redundantly: disabled means both ICN ports forward simultaneously (and must not be wired into the same switch, or a loop results), while ring means only one port forwards at a time, automatically failing over if it's disconnected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8708.2.11.2.7.2
snmpwalk -v2c -c public <target> LUM-EQUIPMENT-MIB::equipmentNodeIcnRedundancyMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8708.2.11.2.7.2.1
snmpget -v2c -c public <target> LUM-EQUIPMENT-MIB::equipmentNodeIcnRedundancyMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8708.2.11.2.7.2.1 i <value>

Start monitoring Infinera optical transport network element / chassis (equipment inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LUM-EQUIPMENT-MIB::equipmentNodeIcnRedundancyMode OID value, configure state conditions and alerts, and monitor any Infinera optical transport network element / chassis (equipment inventory) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8708lumentisLUM-REG
1.3.6.1.4.1.8708.2lumGenericLUM-REG
1.3.6.1.4.1.8708.2.11lumEquipmentMIBLUM-REG
Numeric OIDNameModule
1.3.6.1.4.1.8708.2.11.2lumEquipmentMIBObjectsLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.7equipmentNodeLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.7.2equipmentNodeIcnRedundancyModeLUM-EQUIPMENT-MIB