LUM-EQUIPMENT-MIB :: equipmentBoardTempLowThreshold

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LUM-EQUIPMENT-MIB › equipmentBoardTempLowThreshold

equipmentBoardTempLowThreshold

Module: LUM-EQUIPMENT-MIB

OID (symbolic): LUM-EQUIPMENT-MIB::equipmentBoardTempLowThreshold

OID (numeric): 1.3.6.1.4.1.8708.2.11.2.3.1.1.34

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The threshold for low temperature alarm on the board in 0.1 degrees centigrade.

What is equipmentBoardTempLowThreshold?

The low-temperature alarm threshold for this board, in tenths of a degree Celsius, defaulting to 30 (3.0 C).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8708.2.11.2.3.1.1.34
snmpwalk -v2c -c public <target> LUM-EQUIPMENT-MIB::equipmentBoardTempLowThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8708.2.11.2.3.1.1.34.1
snmpget -v2c -c public <target> LUM-EQUIPMENT-MIB::equipmentBoardTempLowThreshold.1

Start monitoring Infinera optical transport network element / chassis (equipment inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LUM-EQUIPMENT-MIB::equipmentBoardTempLowThreshold OID value, configure state conditions and alerts, and monitor any Infinera optical transport network element / chassis (equipment inventory) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8708lumentisLUM-REG
1.3.6.1.4.1.8708.2lumGenericLUM-REG
1.3.6.1.4.1.8708.2.11lumEquipmentMIBLUM-REG
Numeric OIDNameModule
1.3.6.1.4.1.8708.2.11.2lumEquipmentMIBObjectsLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.3equipmentBoardListLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.3.1equipmentBoardTableLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.3.1.1equipmentBoardEntryLUM-EQUIPMENT-MIB
1.3.6.1.4.1.8708.2.11.2.3.1.1.34equipmentBoardTempLowThresholdLUM-EQUIPMENT-MIB