All MIBs › JNX-OPT-IF-MIB
Organization: IETF AToM MIB Working Group
Last Updated: 2003-08-13
Category: Domain: Optical Transport, Network Interfaces, Optical and WDM, Technology: Optical Transport, Vendor: Juniper
Description: Provides management objects for optical interfaces on Juniper Networks devices, including signal level, wavelength, and transceiver status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is JNX-OPT-IF-MIB?
JNX-OPT-IF-MIB is a Juniper Networks MIB, closely modeled on RFC 3591, for managing pre-OTN and OTN (Optical Transport Network) interfaces such as those found on Juniper's optical/DWDM-capable line cards. It exposes data on Optical Transport Module (OTM) framing structures -- order, reduced/full framing, supported bit rates, interface type, tandem connection monitoring (TCM) depth, and optical reach -- as well as performance-monitoring interval tables. Its monitoring value lies in tracking optical hardware and signal status: bit-rate and framing configuration, optical reach capability, and current/daily elapsed-time performance-monitoring counters that reveal error seconds or signal degradation on optical transport links. It explicitly derives from and depends on RFC 3591 (the standard OTN interface MIB), extending it with Juniper-specific object identifiers. It is typically deployed on Juniper routers equipped with OTN/DWDM optical interfaces in service-provider transport and long-haul/metro optical networks, with the JNX-OPT-IF-MIB MIB defining the framing and performance-monitoring objects those deployments rely on.
IPNetwork Monitor allows you to monitor SNMP objects defined in JNX-OPT-IF-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Juniper Networks router with OTN/DWDM optical interfaces
Monitoring Examples
An administrator polls jnxoptIfOTMnTable (jnxoptIfOTMnEntry: jnxoptIfOTMnOrder, jnxoptIfOTMnBitRates, jnxoptIfOTMnInterfaceType, jnxoptIfOTMnOpticalReach) to confirm an optical line card is configured for the correct OTN framing and bit rate for its DWDM circuit. Polling jnxoptIfPerfMonIntervalTable (jnxoptIfPerfMonCurrentTimeElapsed, jnxoptIfPerfMonCurDayTimeElapsed) lets the admin track how far into the current 15-minute or 24-hour performance bin the counters are, so a spike in optical errors within that window can be correctly attributed to a specific time period, revealing transient fiber degradation or amplifier issues.
What Can Be Monitored
- OTN framing order and bit rate configuration
- optical interface type and reach
- tandem connection monitoring depth
- performance-monitoring interval elapsed time
- optical signal/error performance counters
This MIB depends on
Related MIBs
Imported Objects
From IF-MIB
| ifIndex | OBJECT-TYPE |
From JUNIPER-SMI
| jnxoptIfMibRoot | OBJECT-IDENTITY |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Gauge32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 | |
| transmission |
From SNMPv2-TC
| RowPointer | |
| RowStatus | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| jnxoptIfMibModule | 1.3.6.1.4.1.2636.3.73.1 | The MIB module to describe pre-OTN and OTN interfaces. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3591; see the RFC itself for full legal notices. | ||
| jnxoptIfObjects | 1.3.6.1.4.1.2636.3.73.1.1 | |||
| jnxoptIfOTMn | 1.3.6.1.4.1.2636.3.73.1.1.1 | |||
| jnxoptIfOTMnTable | 1.3.6.1.4.1.2636.3.73.1.1.1.1 | not-accessible | A table of OTMn structure information. | |
| jnxoptIfOTMnEntry | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1 | not-accessible | A conceptual row that contains the OTMn structure information of an optical interface. | |
| U32 jnxoptIfOTMnOrder | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.1 | Unsigned32 | read-only | This object indicates the order of the OTM, which represents the maximum number of wavelengths that can be supported at the bit rate(s) supported on the interface. |
| T/F jnxoptIfOTMnReduced | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.2 | TruthValue | read-only | This object indicates whether a reduced or full functionality is supported at the interface. A value of true means reduced. A value of false means full. |
| BIT jnxoptIfOTMnBitRates | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.3 | Bits | read-only | This attribute is a bit map representing the bit rate or set of bit rates supported on the interface. The meaning of each bit position is as follows: bitRateK1(0) is set if the 2.5 Gbit/s rate is supported bitRateK2(1) is set if the 10 Gbit/s rate is supported bitRateK3(2) is set if the 40 Gbit/s rate is supported Note that each bit position corresponds to one possible value of the type JnxoptIfBitRateK. The default value of this attribute is system specific. |
| STR jnxoptIfOTMnInterfaceType | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.4 | SnmpAdminString | read-only | This object identifies the type of interface. The value of this attribute will affect the behavior of the OTM with respect to presence/absence of OTM Overhead Signal (OOS) processing and TCM activation. For an IrDI interface, there is no OOS processing and TCM activation is limited to n levels as specified by a TCM level threshold. This object contains two fields that are separated by whitespace. The possible values are: field 1: one of the 4-character ASCII strings 'IrDI' or 'IaDI' field 2: free-form text consisting of printable UTF-8 encoded characters Note that field 2 is optional. If it is not present then there is no requirement for trailing whitespace after field 1. The default values are as follows: field 1: 'IaDI' field 2: an empty string. |
| U32 jnxoptIfOTMnTcmMax | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.5 | Unsigned32 | read-write | This object identifies the maximum number of TCM levels allowed for any Optical Channel contained in this OTM. A new TCM activation will be rejected if the requested level is greater than the threshold. If InterfaceType object specifies a type of 'IaDI' for this OTM, then this attribute is irrelevant. Possible values: unsigned integers in the range from 0 to 6 inclusive. Default value: 3. |
| INT jnxoptIfOTMnOpticalReach | 1.3.6.1.4.1.2636.3.73.1.1.1.1.1.6 | INTEGER | read-only | This object indicates the length the optical signal may travel before requiring termination or regeneration. The meaning of the enumeration are: intraOffice(1) - intra-office (as defined in ITU-T G.957) shortHaul(2) - short haul (as defined in ITU-T G.957) longHaul(3) - long haul (as defined in ITU-T G.957) veryLongHaul(4) - very long haul (as defined in ITU-T G.691) ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691) |
| jnxoptIfPerfMon | 1.3.6.1.4.1.2636.3.73.1.1.2 | |||
| jnxoptIfPerfMonIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.2.1 | not-accessible | A table of 15-minute performance monitoring interval information. | |
| jnxoptIfPerfMonIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.2.1.1 | not-accessible | A conceptual row that contains 15-minute performance monitoring interval information of an interface. | |
| G32 jnxoptIfPerfMonCurrentTimeElapsed | 1.3.6.1.4.1.2636.3.73.1.1.2.1.1.1 | Gauge32 | read-only | Number of seconds elapsed in the current 15-minute performance monitoring interval. If, for some reason, such as an adjustment in the NE's time-of-day clock, the number of seconds elapsed exceeds the maximum value, then the maximum value will be returned. |
| G32 jnxoptIfPerfMonCurDayTimeElapsed | 1.3.6.1.4.1.2636.3.73.1.1.2.1.1.2 | Gauge32 | read-only | Number of seconds elapsed in the current 24-hour interval performance monitoring period. If, for some reason, such as an adjustment in the NE time-of-day clock, the number of seconds elapsed exceeds the maximum value, then the maximum value will be returned. |
| U32 jnxoptIfPerfMonIntervalNumIntervals | 1.3.6.1.4.1.2636.3.73.1.1.2.1.1.3 | Unsigned32 | read-only | The number of 15-minute intervals for which performance monitoring data is available. The number is the same for all the associated sub layers of the interface. An optical interface must be capable of supporting at least n intervals, where n is defined as follows: The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless performance monitoring was (re-)started for the interface within the last (n*15) minutes, in which case the value will be the number of complete 15-minute intervals since measurement was (re-)started. |
| U32 jnxoptIfPerfMonIntervalNumInvalidIntervals | 1.3.6.1.4.1.2636.3.73.1.1.2.1.1.4 | Unsigned32 | read-only | The number of intervals in the range from 0 to jnxoptIfPerfMonIntervalNumIntervals for which no performance monitoring data is available and/or the data is invalid. |
| jnxoptIfOTSn | 1.3.6.1.4.1.2636.3.73.1.1.3 | |||
| jnxoptIfOTSnConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.3.1 | not-accessible | A table of OTSn configuration information. | |
| jnxoptIfOTSnConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1 | not-accessible | A conceptual row that contains OTSn configuration information of an interface. | |
| JNX jnxoptIfOTSnDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| STR jnxoptIfOTSnAprStatus | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.2 | SnmpAdminString | read-only | This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'off'. |
| STR jnxoptIfOTSnAprControl | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.3 | SnmpAdminString | read-write | This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (when written) and that returns the current APR control state of this entity (when read). The values are implementation-defined. Any implementation that instantiates this object must document the set of values that it allows to be written, the set of values that it will return, and what each of those values means. |
| JNX jnxoptIfOTSnTraceIdentifierTransmitted | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.4 | JnxoptIfTxTI | read-write | The trace identifier transmitted. This object is applicable when jnxoptIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object jnxoptIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. |
| JNX jnxoptIfOTSnDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.5 | JnxoptIfExDAPI | read-write | The DAPI expected by the receiver. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if jnxoptIfOTSnTIMDetMode has the value off(1) or sapi(3). This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). |
| JNX jnxoptIfOTSnSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.6 | JnxoptIfExSAPI | read-write | The SAPI expected by the receiver. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if jnxoptIfOTSnTIMDetMode has the value off(1) or dapi(2). This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). |
| JNX jnxoptIfOTSnTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.7 | JnxoptIfAcTI | read-only | The actual trace identifier received. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). Its value is unspecified if jnxoptIfOTSnCurrentStatus has either or both of the losO(5) and los(6) bits set. This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). |
| JNX jnxoptIfOTSnTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.8 | JnxoptIfTIMDetMode | read-write | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). The default value is off(1). This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). The default value of this object is off(1). |
| T/F jnxoptIfOTSnTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.9 | TruthValue | read-write | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect when the value of jnxoptIfOTSnTIMDetMode is off(1). This object does not apply to reduced-capability systems (i.e., those for which jnxoptIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when jnxoptIfOTMnInterfaceType field 1 has the value 'IrDI'). The default value of this object is false(2). |
| BIT jnxoptIfOTSnCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.3.1.1.10 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is applicable when jnxoptIfOTSnDirectionality has the value sink(1) or bidirectional(3). In reduced-capability systems or at IrDI interfaces the only bit position that may be set is los(6). |
| jnxoptIfOTSnSinkCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.3.2 | not-accessible | A table of OTSn sink performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOTSnSinkCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1 | not-accessible | A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOTSnSinkCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSinkCurrentInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.2 | Integer32 | read-only | The optical power monitored at the input. |
| I32 jnxoptIfOTSnSinkCurrentLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.3 | Integer32 | read-only | The lowest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOTSnSinkCurrentHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.4 | Integer32 | read-only | The highest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOTSnSinkCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.5 | Integer32 | read-write | The lower limit threshold on input power. If jnxoptIfOTSnSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSinkCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.6 | Integer32 | read-write | The upper limit threshold on input power. If jnxoptIfOTSnSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSinkCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.7 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOTSnSinkCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.8 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOTSnSinkCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.9 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOTSnSinkCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.10 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOTSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSinkCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.2.1.11 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOTSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOTSnSinkIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.3.3 | not-accessible | A table of historical OTSn sink performance monitoring information. | |
| jnxoptIfOTSnSinkIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1 | not-accessible | A conceptual row that contains OTSn sink performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOTSnSinkIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOTSnSinkIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSinkIntervalLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.3 | Integer32 | read-only | The last optical power monitored at the input during the interval. |
| I32 jnxoptIfOTSnSinkIntervalLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.4 | Integer32 | read-only | The lowest optical power monitored at the input during the interval. |
| I32 jnxoptIfOTSnSinkIntervalHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.5 | Integer32 | read-only | The highest optical power monitored at the input during the interval. |
| I32 jnxoptIfOTSnSinkIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.6 | Integer32 | read-only | The last optical power monitored at the output during the interval. |
| I32 jnxoptIfOTSnSinkIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.7 | Integer32 | read-only | The lowest optical power monitored at the output during the interval. |
| I32 jnxoptIfOTSnSinkIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.3.1.8 | Integer32 | read-only | The highest optical power monitored at the output during the interval. |
| jnxoptIfOTSnSinkCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.3.4 | not-accessible | A table of OTSn sink performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOTSnSinkCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1 | not-accessible | A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOTSnSinkCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSinkCurDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1.2 | Integer32 | read-only | The lowest optical power monitored at the input during the current 24-hour interval. |
| I32 jnxoptIfOTSnSinkCurDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1.3 | Integer32 | read-only | The highest optical power monitored at the input during the current 24-hour interval. |
| I32 jnxoptIfOTSnSinkCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1.4 | Integer32 | read-only | The lowest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOTSnSinkCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.4.1.5 | Integer32 | read-only | The highest optical power monitored at the output during the current 24-hour interval. |
| jnxoptIfOTSnSinkPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.3.5 | not-accessible | A table of OTSn sink performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOTSnSinkPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1 | not-accessible | A conceptual row that contains OTSn sink performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOTSnSinkPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSinkPrevDayLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.2 | Integer32 | read-only | The last optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSinkPrevDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.3 | Integer32 | read-only | The lowest optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSinkPrevDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.4 | Integer32 | read-only | The highest optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSinkPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.5 | Integer32 | read-only | The last optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSinkPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.6 | Integer32 | read-only | The lowest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSinkPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.5.1.7 | Integer32 | read-only | The highest optical power monitored at the output during the previous 24-hour interval. |
| jnxoptIfOTSnSrcCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.3.6 | not-accessible | A table of OTSn source performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOTSnSrcCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1 | not-accessible | A conceptual row that contains OTSn source performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOTSnSrcCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSrcCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.2 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOTSnSrcCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOTSnSrcCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOTSnSrcCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.5 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOTSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSrcCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.6 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOTSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSrcCurrentInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.7 | Integer32 | read-only | The optical power monitored at the input. |
| I32 jnxoptIfOTSnSrcCurrentLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.8 | Integer32 | read-only | The lowest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOTSnSrcCurrentHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.9 | Integer32 | read-only | The highest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOTSnSrcCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.10 | Integer32 | read-write | The lower limit threshold on input power. If jnxoptIfOTSnSrcCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOTSnSrcCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.3.6.1.11 | Integer32 | read-write | The upper limit threshold on input power. If jnxoptIfOTSnSrcCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOTSnSrcIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.3.7 | not-accessible | A table of historical OTSn source performance monitoring information. | |
| jnxoptIfOTSnSrcIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1 | not-accessible | A conceptual row that contains OTSn source performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOTSnSrcIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOTSnSrcIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSrcIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.3 | Integer32 | read-only | The last optical power monitored at the output during the interval. |
| I32 jnxoptIfOTSnSrcIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.4 | Integer32 | read-only | The lowest optical power monitored at the output during the interval. |
| I32 jnxoptIfOTSnSrcIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.5 | Integer32 | read-only | The highest optical power monitored at the output during the interval. |
| I32 jnxoptIfOTSnSrcIntervalLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.6 | Integer32 | read-only | The last optical power monitored at the input during the interval. |
| I32 jnxoptIfOTSnSrcIntervalLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.7 | Integer32 | read-only | The lowest optical power monitored at the input during the interval. |
| I32 jnxoptIfOTSnSrcIntervalHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.7.1.8 | Integer32 | read-only | The highest optical power monitored at the input during the interval. |
| jnxoptIfOTSnSrcCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.3.8 | not-accessible | A table of OTSn source performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOTSnSrcCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1 | not-accessible | A conceptual row that contains OTSn source performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOTSnSrcCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSrcCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1.2 | Integer32 | read-only | The lowest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOTSnSrcCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1.3 | Integer32 | read-only | The highest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOTSnSrcCurDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1.4 | Integer32 | read-only | The lowest optical power monitored at the input during the current 24-hour interval. |
| I32 jnxoptIfOTSnSrcCurDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.8.1.5 | Integer32 | read-only | The highest optical power monitored at the input during the current 24-hour interval. |
| jnxoptIfOTSnSrcPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.3.9 | not-accessible | A table of OTSn source performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOTSnSrcPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1 | not-accessible | A conceptual row that contains OTSn source performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOTSnSrcPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOTSnSrcPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.2 | Integer32 | read-only | The last optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSrcPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSrcPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSrcPrevDayLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.5 | Integer32 | read-only | The last optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSrcPrevDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.6 | Integer32 | read-only | The lowest optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOTSnSrcPrevDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.3.9.1.7 | Integer32 | read-only | The highest optical power monitored at the input during the previous 24-hour interval. |
| jnxoptIfOMSn | 1.3.6.1.4.1.2636.3.73.1.1.4 | |||
| jnxoptIfOMSnConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.4.1 | not-accessible | A table of OMSn configuration information. | |
| jnxoptIfOMSnConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.1.1 | not-accessible | A conceptual row that contains OMSn configuration information of an interface. | |
| JNX jnxoptIfOMSnDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.4.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| BIT jnxoptIfOMSnCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.4.1.1.2 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is applicable only to full capability systems whose interface type is IaDI and for which jnxoptIfOMSnDirectionality has the value sink(1) or bidirectional(3). |
| jnxoptIfOMSnSinkCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.4.2 | not-accessible | A table of OMSn sink performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOMSnSinkCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1 | not-accessible | A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOMSnSinkCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSinkCurrentAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.2 | Integer32 | read-only | The aggregated optical power of all the DWDM input channels. |
| I32 jnxoptIfOMSnSinkCurrentLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.3 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels during the current 15-minute interval. |
| I32 jnxoptIfOMSnSinkCurrentHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.4 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels during the current 15-minute interval. |
| I32 jnxoptIfOMSnSinkCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.5 | Integer32 | read-write | The lower limit threshold on aggregated input power. If jnxoptIfOMSnSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSinkCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.6 | Integer32 | read-write | The upper limit threshold on aggregated input power. If jnxoptIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSinkCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.7 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOMSnSinkCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.8 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOMSnSinkCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.9 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOMSnSinkCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.10 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOMSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSinkCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.2.1.11 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOMSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOMSnSinkIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.4.3 | not-accessible | A table of historical OMSn sink performance monitoring information. | |
| jnxoptIfOMSnSinkIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1 | not-accessible | A conceptual row that contains OMSn sink performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOMSnSinkIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOMSnSinkIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSinkIntervalLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.3 | Integer32 | read-only | The last aggregated optical power of all the DWDM input channels during the interval. |
| I32 jnxoptIfOMSnSinkIntervalLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.4 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels during the interval. |
| I32 jnxoptIfOMSnSinkIntervalHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.5 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels during the interval. |
| I32 jnxoptIfOMSnSinkIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.6 | Integer32 | read-only | The last optical power at the output during the interval. |
| I32 jnxoptIfOMSnSinkIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.7 | Integer32 | read-only | The lowest optical power at the output during the interval. |
| I32 jnxoptIfOMSnSinkIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.3.1.8 | Integer32 | read-only | The highest optical power at the output during the interval. |
| jnxoptIfOMSnSinkCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.4.4 | not-accessible | A table of OMSn sink performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOMSnSinkCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1 | not-accessible | A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOMSnSinkCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSinkCurDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1.2 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels during the current 24-hour interval. |
| I32 jnxoptIfOMSnSinkCurDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1.3 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels during the current 24-hour interval. |
| I32 jnxoptIfOMSnSinkCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1.4 | Integer32 | read-only | The lowest optical power at the output during the current 24-hour interval. |
| I32 jnxoptIfOMSnSinkCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.4.1.5 | Integer32 | read-only | The highest optical power at the output during the current 24-hour interval. |
| jnxoptIfOMSnSinkPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.4.5 | not-accessible | A table of OMSn sink performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOMSnSinkPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1 | not-accessible | A conceptual row that contains OMSn sink performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOMSnSinkPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSinkPrevDayLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.2 | Integer32 | read-only | The last aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSinkPrevDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.3 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSinkPrevDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.4 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSinkPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.5 | Integer32 | read-only | The last optical power at the output during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSinkPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.6 | Integer32 | read-only | The lowest optical power at the output during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSinkPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.5.1.7 | Integer32 | read-only | The highest optical power at the output during the previous 24-hour interval. |
| jnxoptIfOMSnSrcCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.4.6 | not-accessible | A table of OMSn source performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOMSnSrcCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1 | not-accessible | A conceptual row that contains OMSn source performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOMSnSrcCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSrcCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.2 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOMSnSrcCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOMSnSrcCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOMSnSrcCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.5 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOMSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSrcCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.6 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOMSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSrcCurrentAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.7 | Integer32 | read-only | The aggregated optical power at the input. |
| I32 jnxoptIfOMSnSrcCurrentLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.8 | Integer32 | read-only | The lowest aggregated optical power at the input during the current 15-minute interval. |
| I32 jnxoptIfOMSnSrcCurrentHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.9 | Integer32 | read-only | The highest aggregated optical power at the input during the current 15-minute interval. |
| I32 jnxoptIfOMSnSrcCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.10 | Integer32 | read-write | The lower limit threshold on aggregated input power. If jnxoptIfOMSnSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOMSnSrcCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.4.6.1.11 | Integer32 | read-write | The upper limit threshold on aggregated input power. If jnxoptIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOMSnSrcIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.4.7 | not-accessible | A table of historical OMSn source performance monitoring information. | |
| jnxoptIfOMSnSrcIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1 | not-accessible | A conceptual row that contains OMSn source performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOMSnSrcIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOMSnSrcIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSrcIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.3 | Integer32 | read-only | The last optical power monitored at the output during the interval. |
| I32 jnxoptIfOMSnSrcIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.4 | Integer32 | read-only | The lowest optical power monitored at the output during the interval. |
| I32 jnxoptIfOMSnSrcIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.5 | Integer32 | read-only | The highest optical power monitored at the output during the interval. |
| I32 jnxoptIfOMSnSrcIntervalLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.6 | Integer32 | read-only | The last aggregated optical power at the input during the interval. |
| I32 jnxoptIfOMSnSrcIntervalLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.7 | Integer32 | read-only | The lowest aggregated optical power at the input during the interval. |
| I32 jnxoptIfOMSnSrcIntervalHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.7.1.8 | Integer32 | read-only | The highest aggregated optical power at the input during the interval. |
| jnxoptIfOMSnSrcCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.4.8 | not-accessible | A table of OMSn source performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOMSnSrcCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1 | not-accessible | A conceptual row that contains OMSn source performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOMSnSrcCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSrcCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1.2 | Integer32 | read-only | The lowest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOMSnSrcCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1.3 | Integer32 | read-only | The highest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOMSnSrcCurDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1.4 | Integer32 | read-only | The lowest aggregated optical power at the input during the current 24-hour interval. |
| I32 jnxoptIfOMSnSrcCurDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.8.1.5 | Integer32 | read-only | The highest aggregated optical power at the input during the current 24-hour interval. |
| jnxoptIfOMSnSrcPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.4.9 | not-accessible | A table of OMSn source performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOMSnSrcPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1 | not-accessible | A conceptual row that contains OMSn source performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOMSnSrcPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOMSnSrcPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.2 | Integer32 | read-only | The last optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSrcPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSrcPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSrcPrevDayLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.5 | Integer32 | read-only | The last aggregated optical power at the input during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSrcPrevDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.6 | Integer32 | read-only | The lowest aggregated optical power at the input during the previous 24-hour interval. |
| I32 jnxoptIfOMSnSrcPrevDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.4.9.1.7 | Integer32 | read-only | The highest aggregated optical power at the input during the previous 24-hour interval. |
| jnxoptIfOChGroup | 1.3.6.1.4.1.2636.3.73.1.1.5 | |||
| jnxoptIfOChGroupConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.5.1 | not-accessible | A table of OChGroup configuration information. | |
| jnxoptIfOChGroupConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.1.1 | not-accessible | A conceptual row that contains OChGroup configuration information of an interface. | |
| JNX jnxoptIfOChGroupDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.5.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| jnxoptIfOChGroupSinkCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.5.2 | not-accessible | A table of OChGroup sink performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOChGroupSinkCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1 | not-accessible | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOChGroupSinkCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSinkCurrentAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.2 | Integer32 | read-only | The aggregated optical power of all the DWDM input channels in the OChGroup. |
| I32 jnxoptIfOChGroupSinkCurrentLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.3 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSinkCurrentHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.4 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSinkCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.5 | Integer32 | read-write | The lower limit threshold on aggregated input power. If jnxoptIfOChGroupSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSinkCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.6 | Integer32 | read-write | The upper limit threshold on aggregated input power. If jnxoptIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSinkCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.7 | Integer32 | read-only | The optical power monitored at the output in the OChGroup. |
| I32 jnxoptIfOChGroupSinkCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.8 | Integer32 | read-only | The lowest optical power monitored at the output in the OChGroup during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSinkCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.9 | Integer32 | read-only | The highest optical power monitored at the output in the OChGroup during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSinkCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.10 | Integer32 | read-write | The lower limit threshold on the output power. If jnxoptIfOChGroupSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSinkCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.2.1.11 | Integer32 | read-write | The upper limit threshold on the output power. If jnxoptIfOChGroupSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOChGroupSinkIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.5.3 | not-accessible | A table of historical OChGroup sink performance monitoring information. | |
| jnxoptIfOChGroupSinkIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1 | not-accessible | A conceptual row that contains OChGroup sink performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOChGroupSinkIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOChGroupSinkIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSinkIntervalLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.3 | Integer32 | read-only | The last aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| I32 jnxoptIfOChGroupSinkIntervalLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.4 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| I32 jnxoptIfOChGroupSinkIntervalHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.5 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. |
| I32 jnxoptIfOChGroupSinkIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.6 | Integer32 | read-only | The last optical power monitored at the output in the OChGroup during the interval. |
| I32 jnxoptIfOChGroupSinkIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.7 | Integer32 | read-only | The lowest optical power monitored at the output in the OChGroup during the interval. |
| I32 jnxoptIfOChGroupSinkIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.3.1.8 | Integer32 | read-only | The highest optical power monitored at the output in the OChGroup during the interval. |
| jnxoptIfOChGroupSinkCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.5.4 | not-accessible | A table of OChGroup sink performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOChGroupSinkCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1 | not-accessible | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOChGroupSinkCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSinkCurDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1.2 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSinkCurDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1.3 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSinkCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1.4 | Integer32 | read-only | The lowest optical power monitored at the output in the OChGroup during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSinkCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.4.1.5 | Integer32 | read-only | The highest optical power monitored at the output in the OChGroup during the current 24-hour interval. |
| jnxoptIfOChGroupSinkPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.5.5 | not-accessible | A table of OChGroup sink performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOChGroupSinkPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1 | not-accessible | A conceptual row that contains OChGroup sink performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOChGroupSinkPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSinkPrevDayLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.2 | Integer32 | read-only | The last aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSinkPrevDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.3 | Integer32 | read-only | The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSinkPrevDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.4 | Integer32 | read-only | The highest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSinkPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.5 | Integer32 | read-only | The last optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSinkPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.6 | Integer32 | read-only | The lowest optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSinkPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.5.1.7 | Integer32 | read-only | The highest optical power monitored at the output in the OChGroup during the previous 24-hour interval. |
| jnxoptIfOChGroupSrcCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.5.6 | not-accessible | A table of OChGroup source performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOChGroupSrcCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1 | not-accessible | A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOChGroupSrcCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSrcCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.2 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOChGroupSrcCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSrcCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSrcCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.5 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOChGroupSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSrcCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.6 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOChGroupSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSrcCurrentAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.7 | Integer32 | read-only | The aggregated optical power monitored at the input. |
| I32 jnxoptIfOChGroupSrcCurrentLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.8 | Integer32 | read-only | The lowest aggregated optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSrcCurrentHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.9 | Integer32 | read-only | The highest aggregated optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOChGroupSrcCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.10 | Integer32 | read-write | The lower limit threshold on input power. If jnxoptIfOChGroupSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChGroupSrcCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.5.6.1.11 | Integer32 | read-write | The upper limit threshold on input power. If jnxoptIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOChGroupSrcIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.5.7 | not-accessible | A table of historical OChGroup source performance monitoring information. | |
| jnxoptIfOChGroupSrcIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1 | not-accessible | A conceptual row that contains OChGroup source performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOChGroupSrcIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOChGroupSrcIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSrcIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.3 | Integer32 | read-only | The last optical power monitored at the output during the interval. |
| I32 jnxoptIfOChGroupSrcIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.4 | Integer32 | read-only | The lowest optical power monitored at the output during the interval. |
| I32 jnxoptIfOChGroupSrcIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.5 | Integer32 | read-only | The highest optical power monitored at the output during the interval. |
| I32 jnxoptIfOChGroupSrcIntervalLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.6 | Integer32 | read-only | The last aggregated optical power monitored at the input during the interval. |
| I32 jnxoptIfOChGroupSrcIntervalLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.7 | Integer32 | read-only | The lowest aggregated optical power monitored at the input during the interval. |
| I32 jnxoptIfOChGroupSrcIntervalHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.7.1.8 | Integer32 | read-only | The highest aggregated optical power monitored at the input during the interval. |
| jnxoptIfOChGroupSrcCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.5.8 | not-accessible | A table of OChGroup source performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOChGroupSrcCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1 | not-accessible | A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOChGroupSrcCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSrcCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1.2 | Integer32 | read-only | The lowest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSrcCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1.3 | Integer32 | read-only | The highest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSrcCurDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1.4 | Integer32 | read-only | The lowest aggregated optical power monitored at the input during the current 24-hour interval. |
| I32 jnxoptIfOChGroupSrcCurDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.8.1.5 | Integer32 | read-only | The highest aggregated optical power monitored at the input during the current 24-hour interval. |
| jnxoptIfOChGroupSrcPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.5.9 | not-accessible | A table of OChGroup source performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOChGroupSrcPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1 | not-accessible | A conceptual row that contains OChGroup source performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOChGroupSrcPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChGroupSrcPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.2 | Integer32 | read-only | The last optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSrcPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSrcPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSrcPrevDayLastAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.5 | Integer32 | read-only | The last aggregated optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSrcPrevDayLowAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.6 | Integer32 | read-only | The lowest aggregated optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOChGroupSrcPrevDayHighAggregatedInputPower | 1.3.6.1.4.1.2636.3.73.1.1.5.9.1.7 | Integer32 | read-only | The highest aggregated optical power monitored at the input during the previous 24-hour interval. |
| jnxoptIfOCh | 1.3.6.1.4.1.2636.3.73.1.1.6 | |||
| jnxoptIfOChConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.6.1 | not-accessible | A table of OCh configuration information. | |
| jnxoptIfOChConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.1.1 | not-accessible | A conceptual row that contains OCh configuration information of an interface. | |
| JNX jnxoptIfOChDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.6.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| BIT jnxoptIfOChCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.6.1.1.2 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is applicable when jnxoptIfOChDirectionality has the value sink(1) or bidirectional(3). In full-capability systems the bit position los(1) is not used. In reduced-capability systems or at IrDI interfaces only the bit positions los(1) and ssfP(3) are used. |
| jnxoptIfOChSinkCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.6.2 | not-accessible | A table of OCh sink performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOChSinkCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1 | not-accessible | A conceptual row that contains OCh sink performance monitoring information for an interface for the current 15-minute interval. | |
| T/F jnxoptIfOChSinkCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSinkCurrentInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.2 | Integer32 | read-only | The optical power monitored at the input. |
| I32 jnxoptIfOChSinkCurrentLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.3 | Integer32 | read-only | The lowest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOChSinkCurrentHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.4 | Integer32 | read-only | The highest optical power monitored at the input during the current 15-minute interval. |
| I32 jnxoptIfOChSinkCurrentLowerInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.5 | Integer32 | read-write | The lower limit threshold on input power. If jnxoptIfOChSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChSinkCurrentUpperInputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.6.2.1.6 | Integer32 | read-write | The upper limit threshold on input power. If jnxoptIfOChSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOChSinkIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.6.3 | not-accessible | A table of historical OCh sink performance monitoring information. | |
| jnxoptIfOChSinkIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1 | not-accessible | A conceptual row that contains OCh sink performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOChSinkIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOChSinkIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSinkIntervalLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1.3 | Integer32 | read-only | The last optical power monitored at the input during the interval. |
| I32 jnxoptIfOChSinkIntervalLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1.4 | Integer32 | read-only | The lowest optical power monitored at the input during the interval. |
| I32 jnxoptIfOChSinkIntervalHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.3.1.5 | Integer32 | read-only | The highest optical power monitored at the input during the interval. |
| jnxoptIfOChSinkCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.6.4 | not-accessible | A table of OCh sink performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOChSinkCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.4.1 | not-accessible | A conceptual row that contains OCh sink performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOChSinkCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.4.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSinkCurDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.4.1.2 | Integer32 | read-only | The lowest optical power monitored at the input during the current 24-hour interval. |
| I32 jnxoptIfOChSinkCurDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.4.1.3 | Integer32 | read-only | The highest optical power monitored at the input during the current 24-hour interval. |
| jnxoptIfOChSinkPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.6.5 | not-accessible | A table of OCh sink performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOChSinkPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.5.1 | not-accessible | A conceptual row that contains OCh sink performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOChSinkPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.5.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSinkPrevDayLastInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.5.1.2 | Integer32 | read-only | The last optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOChSinkPrevDayLowInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.5.1.3 | Integer32 | read-only | The lowest optical power monitored at the input during the previous 24-hour interval. |
| I32 jnxoptIfOChSinkPrevDayHighInputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.5.1.4 | Integer32 | read-only | The highest optical power monitored at the input during the previous 24-hour interval. |
| jnxoptIfOChSrcCurrentTable | 1.3.6.1.4.1.2636.3.73.1.1.6.6 | not-accessible | A table of OCh source performance monitoring information for the current 15-minute interval. | |
| jnxoptIfOChSrcCurrentEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1 | not-accessible | A conceptual row that contains OCh source performance monitoring information of an interface for the current 15-minute interval. | |
| T/F jnxoptIfOChSrcCurrentSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSrcCurrentOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.2 | Integer32 | read-only | The optical power monitored at the output. |
| I32 jnxoptIfOChSrcCurrentLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOChSrcCurrentHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the current 15-minute interval. |
| I32 jnxoptIfOChSrcCurrentLowerOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.5 | Integer32 | read-write | The lower limit threshold on output power. If jnxoptIfOChSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. |
| I32 jnxoptIfOChSrcCurrentUpperOutputPowerThreshold | 1.3.6.1.4.1.2636.3.73.1.1.6.6.1.6 | Integer32 | read-write | The upper limit threshold on output power. If jnxoptIfOChSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. |
| jnxoptIfOChSrcIntervalTable | 1.3.6.1.4.1.2636.3.73.1.1.6.7 | not-accessible | A table of historical OCh source performance monitoring information. | |
| jnxoptIfOChSrcIntervalEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1 | not-accessible | A conceptual row that contains OCh source performance monitoring information of an interface during a particular historical interval. | |
| NUM jnxoptIfOChSrcIntervalNumber | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1.1 | JnxoptIfIntervalNumber | not-accessible | Uniquely identifies the interval. |
| T/F jnxoptIfOChSrcIntervalSuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1.2 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSrcIntervalLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1.3 | Integer32 | read-only | The last optical power monitored at the output during the interval. |
| I32 jnxoptIfOChSrcIntervalLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1.4 | Integer32 | read-only | The lowest optical power monitored at the output during the interval. |
| I32 jnxoptIfOChSrcIntervalHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.7.1.5 | Integer32 | read-only | The highest optical power monitored at the output during the interval. |
| jnxoptIfOChSrcCurDayTable | 1.3.6.1.4.1.2636.3.73.1.1.6.8 | not-accessible | A table of OCh source performance monitoring information for the current 24-hour interval. | |
| jnxoptIfOChSrcCurDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.8.1 | not-accessible | A conceptual row that contains OCh source performance monitoring information of an interface for the current 24-hour interval. | |
| T/F jnxoptIfOChSrcCurDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.8.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSrcCurDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.8.1.2 | Integer32 | read-only | The lowest optical power monitored at the output during the current 24-hour interval. |
| I32 jnxoptIfOChSrcCurDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.8.1.3 | Integer32 | read-only | The highest optical power monitored at the output during the current 24-hour interval. |
| jnxoptIfOChSrcPrevDayTable | 1.3.6.1.4.1.2636.3.73.1.1.6.9 | not-accessible | A table of OCh source performance monitoring information for the previous 24-hour interval. | |
| jnxoptIfOChSrcPrevDayEntry | 1.3.6.1.4.1.2636.3.73.1.1.6.9.1 | not-accessible | A conceptual row that contains OCh source performance monitoring information of an interface for the previous 24-hour interval. | |
| T/F jnxoptIfOChSrcPrevDaySuspectedFlag | 1.3.6.1.4.1.2636.3.73.1.1.6.9.1.1 | TruthValue | read-only | If true, the data in this entry may be unreliable. |
| I32 jnxoptIfOChSrcPrevDayLastOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.9.1.2 | Integer32 | read-only | The last optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOChSrcPrevDayLowOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.9.1.3 | Integer32 | read-only | The lowest optical power monitored at the output during the previous 24-hour interval. |
| I32 jnxoptIfOChSrcPrevDayHighOutputPower | 1.3.6.1.4.1.2636.3.73.1.1.6.9.1.4 | Integer32 | read-only | The highest optical power monitored at the output during the previous 24-hour interval. |
| jnxoptIfOTUk | 1.3.6.1.4.1.2636.3.73.1.1.7 | |||
| jnxoptIfOTUkConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.7.1 | not-accessible | A table of OTUk configuration information. | |
| jnxoptIfOTUkConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1 | not-accessible | A conceptual row that contains OTUk configuration information of an interface. | |
| JNX jnxoptIfOTUkDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| JNX jnxoptIfOTUkBitRateK | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.2 | JnxoptIfBitRateK | read-only | Indicates the bit rate of the entity. |
| JNX jnxoptIfOTUkTraceIdentifierTransmitted | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.3 | JnxoptIfTxTI | read-write | The trace identifier transmitted. This object is applicable when jnxoptIfOTUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. |
| JNX jnxoptIfOTUkDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.4 | JnxoptIfExDAPI | read-write | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). This object has no effect when jnxoptIfOTUkTIMDetMode has the value off(1). |
| JNX jnxoptIfOTUkSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.5 | JnxoptIfExSAPI | read-write | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). This object has no effect when jnxoptIfOTUkTIMDetMode has the value off(1). |
| JNX jnxoptIfOTUkTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.6 | JnxoptIfAcTI | read-only | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The value of this object is unspecified when jnxoptIfOTUkCurrentStatus indicates a near-end defect (i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents extraction of the trace message. |
| JNX jnxoptIfOTUkTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.7 | JnxoptIfTIMDetMode | read-write | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The default value of this object is off(1). |
| T/F jnxoptIfOTUkTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.8 | TruthValue | read-write | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). This object has no effect when jnxoptIfOTUkTIMDetMode has the value off(1). The default value of this object is false(2). |
| JNX jnxoptIfOTUkDEGThr | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.9 | JnxoptIfDEGThr | read-write | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to jnxoptIfOTUkDEGThr. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). |
| JNX jnxoptIfOTUkDEGM | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.10 | JnxoptIfDEGM | read-write | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if jnxoptIfOTUkDEGM consecutive bad PM Seconds are detected. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The default value of this object is 7 (See ITU-T G.7710). |
| T/F jnxoptIfOTUkSinkAdaptActive | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.11 | TruthValue | read-write | Indicates whether the sink adaptation function is activated or not. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The default value of this object is false(2). |
| T/F jnxoptIfOTUkSourceAdaptActive | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.12 | TruthValue | read-write | Indicates whether the source adaptation function is activated or not. This object is only applicable to the source function, i.e., only when jnxoptIfOTUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value sink(1). The default value of this object is false(2). |
| T/F jnxoptIfOTUkSinkFECEnabled | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.13 | TruthValue | read-write | If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OTUk sink adaptation function is enabled or not. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). The default value of this object is true(1). |
| BIT jnxoptIfOTUkCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.7.1.1.14 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when jnxoptIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfOTUkDirectionality has the value source(2). |
| jnxoptIfGCC0ConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.7.2 | not-accessible | A table of GCC0 configuration information. | |
| jnxoptIfGCC0ConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.7.2.1 | not-accessible | A conceptual row that contains GCC0 configuration information of an interface. Each instance must correspond to an instance of jnxoptIfOTUkConfigEntry. Separate source and/or sink instances may exist for a given ifIndex value, or a single bidirectional instance may exist, but a bidirectional instance may not coexist with a source or sink instance. Instances of this conceptual row persist across agent restarts. | |
| JNX jnxoptIfGCC0Directionality | 1.3.6.1.4.1.2636.3.73.1.1.7.2.1.1 | JnxoptIfDirectionality | not-accessible | Indicates the directionality of the entity. The values source(2) and bidirectional(3) are not allowed if the corresponding instance of jnxoptIfOTUkDirectionality has the value sink(1). The values sink(1) and bidirectional(3) are not allowed if the corresponding instance of jnxoptIfOTUkDirectionality has the value source(2). |
| STR jnxoptIfGCC0Application | 1.3.6.1.4.1.2636.3.73.1.1.7.2.1.2 | SnmpAdminString | read-create | Indicates the application transported by the GCC0 entity. Example applications are ECC, User data channel. The value of this object may not be changed when jnxoptIfGCC0RowStatus has the value active(1). |
| ROW jnxoptIfGCC0RowStatus | 1.3.6.1.4.1.2636.3.73.1.1.7.2.1.3 | RowStatus | read-create | This columnar object is used for creating and deleting a conceptual row of the jnxoptIfGCC0 config table. It is used to model the addGCC0Access and removeGCC0Access operations of an OTUk_TTP for GCC0 access control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies addGCC0Access. Setting RowStatus to destroy implies removeGCC0Access. |
| jnxoptIfODUk | 1.3.6.1.4.1.2636.3.73.1.1.8 | |||
| jnxoptIfODUkConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.8.1 | not-accessible | A table of ODUk configuration information. | |
| jnxoptIfODUkConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1 | not-accessible | A conceptual row that contains ODUk configuration information of an interface. | |
| JNX jnxoptIfODUkDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1.1 | JnxoptIfDirectionality | read-only | Indicates the directionality of the entity. |
| JNX jnxoptIfODUkBitRateK | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1.2 | JnxoptIfBitRateK | read-only | Indicates the bit rate of the entity. |
| BIT jnxoptIfODUkTcmFieldsInUse | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1.3 | Bits | read-only | Indicates the TCM field(s) that are currently in use. The positions of the bits correspond to the TCM fields. A bit that is set to 1 means that the corresponding TCM field is used. This object will be updated when rows are created in or deleted from the jnxoptIfODUkTConfigTable, or the jnxoptIfODUkTNimConfigTable. |
| U32 jnxoptIfODUkPositionSeqCurrentSize | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1.4 | Unsigned32 | read-only | This variable indicates the current size of the position sequence (i.e., number of TCM function and/or GCC12 access that have been created in the ODUk interface). When the value of this variable is greater than zero, it means that one or more TCM function and/or GCC12 access have been created in the ODUk interface. In this case, there will be as many rows in the jnxoptIfODUkPositionSeqTable as the value of jnxoptIfODUkPositionSeqCurrentSize corresponding to this ODUk interface, one row for each TCM function or GCC12 access. The position of the TCM function and/or GCC12 access within the sequence is indicated by the jnxoptIfODUkPositionSeqPosition variable in jnxoptIfODUkPositionSeqTable. The jnxoptIfODUkPositionSeqTable also provides pointers to the corresponding TCM function (jnxoptIfODUkT) and GCC12 access (jnxoptIfGCC12) entities. |
| T/F jnxoptIfODUkTtpPresent | 1.3.6.1.4.1.2636.3.73.1.1.8.1.1.5 | TruthValue | read-only | This object has the value true(1) if the ifEntry under which it is instantiated contains an ODUk Trail Termination Point, i.e., is the endpoint of an ODUk path. In that case there will be a corresponding row in the ODUk TTP config table and it will not be possible to create corresponding rows in the ODUk NIM config table. This object has the value false(2) if the ifEntry under which it is instantiated contains an intermediate ODUk Connection Termination Point. In that case there is no corresponding row in the ODUk TTP config table, but it will be possible to create corresponding rows in the ODUk NIM config table. This object also affects the allowable options in rows created in the GCC12 config table and in the ODUkT config table, as specified in the DESCRIPTION clauses of the columns in those tables. |
| jnxoptIfODUkTtpConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.8.2 | not-accessible | A table of ODUk TTP configuration information. | |
| jnxoptIfODUkTtpConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1 | not-accessible | A conceptual row that contains ODUk TTP configuration information of an interface. | |
| JNX jnxoptIfODUkTtpTraceIdentifierTransmitted | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.1 | JnxoptIfTxTI | read-write | The trace identifier transmitted. This object is applicable when jnxoptIfODUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. |
| JNX jnxoptIfODUkTtpDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.2 | JnxoptIfExDAPI | read-write | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). This object has no effect when jnxoptIfODUkTtpTIMDetMode has the value off(1). |
| JNX jnxoptIfODUkTtpSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.3 | JnxoptIfExSAPI | read-write | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). This object has no effect when jnxoptIfODUkTtpTIMDetMode has the value off(1). |
| JNX jnxoptIfODUkTtpTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.4 | JnxoptIfAcTI | read-only | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). The value of this object is unspecified when jnxoptIfODUkTtpCurrentStatus indicates a near-end defect (i.e., oci(0), lck(1), ssf(5)) that prevents extraction of the trace message. |
| JNX jnxoptIfODUkTtpTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.5 | JnxoptIfTIMDetMode | read-write | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). The default value of this object is off(1). |
| T/F jnxoptIfODUkTtpTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.6 | TruthValue | read-write | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). This object has no effect when jnxoptIfODUkTtpTIMDetMode has the value off(1). The default value of this object is false(2). |
| JNX jnxoptIfODUkTtpDEGThr | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.7 | JnxoptIfDEGThr | read-write | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to jnxoptIfODUkDEGThr. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). |
| JNX jnxoptIfODUkTtpDEGM | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.8 | JnxoptIfDEGM | read-write | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if jnxoptIfODUkDEGM consecutive bad PM Seconds are detected. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). The default value of this object is 7 (See ITU-T G.7710). |
| BIT jnxoptIfODUkTtpCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.8.2.1.9 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when jnxoptIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where jnxoptIfODUkDirectionality has the value source(2). |
| jnxoptIfODUkPositionSeqTable | 1.3.6.1.4.1.2636.3.73.1.1.8.3 | not-accessible | A table of ODUk Position Sequence information. | |
| jnxoptIfODUkPositionSeqEntry | 1.3.6.1.4.1.2636.3.73.1.1.8.3.1 | not-accessible | A conceptual row that contains ODUk position sequence information of an ODUk interface. The ODUk interface is identified by the ifIndex. Associated with each ODUk interface there may be one of more conceptual rows in the jnxoptIfODUkPositionSeqTable. Each row represents a TCM or GCC12 access function within the associated ODUk interface. Rows of the jnxoptIfODUkPositionSeqTable table are created/deleted as the result of the creation/deletion of the jnxoptIfODUkT or jnxoptIfGCC12 entities. | |
| U32 jnxoptIfODUkPositionSeqIndex | 1.3.6.1.4.1.2636.3.73.1.1.8.3.1.1 | Unsigned32 | not-accessible | This variable identifies a row in the jnxoptIfODUkPositionSeqTable Table. Each row of the jnxoptIfODUkPositionSeqTable Table represents a TCM or GCC12 access function within the associated ODUk interface. |
| U32 jnxoptIfODUkPositionSeqPosition | 1.3.6.1.4.1.2636.3.73.1.1.8.3.1.2 | Unsigned32 | read-only | This variable indicates the position of the TCM or GCC12 access function within the sequence of TCMs & GCC12 access functions of the associated ODUk interface. The TCM or GCC12 presented by this row is referenced by the jnxoptIfODUkPositionSeqPointer variable. |
| NUM jnxoptIfODUkPositionSeqPointer | 1.3.6.1.4.1.2636.3.73.1.1.8.3.1.3 | RowPointer | read-only | This variable identifies the TCM or GCC12 access function by pointing to the corresponding jnxoptIfODUkT or jnxoptIfGCC12 entity. |
| jnxoptIfODUkNimConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.8.4 | not-accessible | A table of ODUkNim configuration information. | |
| jnxoptIfODUkNimConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1 | not-accessible | A conceptual row that contains ODUkNim configuration information of an interface. Each instance must correspond to an instance of jnxoptIfODUkConfigEntry for which jnxoptIfODUkTtpPresent has the value false(2). Instances of this conceptual row persist across agent restarts, and read-create columns other than the status column may be modified while the row is active. | |
| JNX jnxoptIfODUkNimDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.1 | JnxoptIfSinkOrSource | not-accessible | Specifies the monitor point for the ODUk Path non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction path signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP. Monitoring the source direction of an ODUk CTP is necessary in those cases where the ODUk CTP is at an SNCP (Subnetwork Connection Protection) end (e.g., see Figure I.1.2/G.874.1). If one would like to get the performance of the protected connection, one cannot use the NIM function at both ODUk CTP sinks (before the matrix), instead one should monitor the signal at the source ODUk CTP after the matrix. |
| JNX jnxoptIfODUkNimDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.2 | JnxoptIfExDAPI | read-create | The DAPI expected by the receiver. This object has no effect if jnxoptIfODUkNimTIMDetMode has the value off(1) or sapi(3). |
| JNX jnxoptIfODUkNimSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.3 | JnxoptIfExSAPI | read-create | The SAPI expected by the receiver. This object has no effect if jnxoptIfODUkNimTIMDetMode has the value off(1) or dapi(2). |
| JNX jnxoptIfODUkNimTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.4 | JnxoptIfAcTI | read-only | The actual trace identifier accepted. The value of this object is unspecified if jnxoptIfODUkNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if jnxoptIfODUkNimRowStatus has any value other than active(1). |
| JNX jnxoptIfODUkNimTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.5 | JnxoptIfTIMDetMode | read-create | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
| T/F jnxoptIfODUkNimTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.6 | TruthValue | read-create | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
| JNX jnxoptIfODUkNimDEGThr | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.7 | JnxoptIfDEGThr | read-create | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to jnxoptIfODUkNimDEGThr. |
| JNX jnxoptIfODUkNimDEGM | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.8 | JnxoptIfDEGM | read-create | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if jnxoptIfODUkNimDEGM consecutive bad PM Seconds are detected. |
| BIT jnxoptIfODUkNimCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.9 | Bits | read-only | Indicates the defect condition of the entity, if any. The value of this object is unspecified if jnxoptIfODUkNimRowStatus has any value other than active(1). |
| ROW jnxoptIfODUkNimRowStatus | 1.3.6.1.4.1.2636.3.73.1.1.8.4.1.10 | RowStatus | read-create | This columnar object is used for creating and deleting a conceptual row of the jnxoptIfODUkNim config table. It is used to model the activateNim and deactivateNim operations of an OTUk_CTP for non-intrusive monitoring control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies activateNim. Setting RowStatus to destroy implies deactivateNim. |
| jnxoptIfGCC12ConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.8.5 | not-accessible | A table of GCC12 configuration information. The GCC function processes the GCC overhead bytes passing through them but leave the remainder of the ODUk overhead and payload data alone. | |
| jnxoptIfGCC12ConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1 | not-accessible | A conceptual row that contains GCC12 configuration information of an interface. Each instance must correspond to an instance of jnxoptIfODUkConfigEntry. Separate instances providing GCC1-only access and GCC2-only access may exist for a given ifIndex value, or a single instance providing GCC1 + GCC2 may exist, but a GCC1 + GCC2 instance may not coexist with a GCC1-only or GCC2-only instance. Instances of this conceptual row persist across agent restarts. | |
| T/F jnxoptIfGCC12Codirectional | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1.1 | TruthValue | not-accessible | Indicates the directionality of the GCC12 termination with respect to the associated ODUk CTP. The value true(1) means that the sink part of the GCC12 extracts COMMS data from the signal at the input to the ODUk CTP sink and the source part of the GCC12 inserts COMMS data into the signal at the output of the ODUk CTP source. The value false(2) means that the sink part of the GCC12 extracts COMMS data from the signal at the output of the ODUk CTP source and the source part of the GCC12 inserts COMMS data into the signal at the input of the ODUk CTP sink. This attribute may assume either value when the corresponding instance of jnxoptIfODUkTtpPresent has the value false(2). When the value of the corresponding instance of jnxoptIfODUkTtpPresent is true(1) then the only value allowed for this attribute is true(1). |
| INT jnxoptIfGCC12GCCAccess | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1.2 | INTEGER | not-accessible | Indicates the GCC access represented by the entity. |
| T/F jnxoptIfGCC12GCCPassThrough | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1.3 | TruthValue | read-create | Controls whether the selected GCC overhead bytes are passed through or modified. The value true(1) means that the selected GCC overhead bytes are passed through unmodified from the ODUk CTP input to the ODUk CTP output. The value false(2) means that the selected GCC overhead bytes are set to zero at the ODUk CTP output after the extraction of the COMMS data. This object has no effect if the corresponding instance of jnxoptIfODUkTtpPresent has the value true(1). The value of this object may not be changed when jnxoptIfGCC12RowStatus has the value active(1). |
| STR jnxoptIfGCC12Application | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1.4 | SnmpAdminString | read-create | Indicates the application transported by the GCC12 entity. Example applications are ECC, User data channel. The value of this object may not be changed when jnxoptIfGCC12RowStatus has the value active(1). |
| ROW jnxoptIfGCC12RowStatus | 1.3.6.1.4.1.2636.3.73.1.1.8.5.1.5 | RowStatus | read-create | This columnar object is used for creating and deleting a conceptual row of the jnxoptIfGCC12 config table. It is used to model the addGCC12Access and removeGCC12Access operations of an ODUk_CTP or ODUk_TTP for GCC12 access control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies addGCC12Access. Setting RowStatus to destroy implies removeGCC12Access. Successful addition/removal of the GCC12 access function will result in updating the jnxoptIfODUkPositionSeqCurrentSize variable and the jnxoptIfODUkPositionSeqTable table of the associated ODUk entry in the jnxoptIfODUkConfigTable. |
| jnxoptIfODUkT | 1.3.6.1.4.1.2636.3.73.1.1.9 | |||
| jnxoptIfODUkTConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.9.1 | not-accessible | A table of ODUkT configuration information. | |
| jnxoptIfODUkTConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1 | not-accessible | A conceptual row that contains ODUkT configuration information of an interface. Each instance must correspond to an instance of jnxoptIfODUkConfigEntry. Rows in this table are mutually exclusive with rows in the ODUkT NIM config table -- in other words, this row object may not be instantiated for a given pair of ifIndex and TCM field values if a corresponding instance of jnxoptIfODUkTNimConfigEntry already exists. Instances of this conceptual row persist across agent restarts. Except where noted otherwise, read-create columns other than the status column may be modified while the row is active. | |
| U32 jnxoptIfODUkTTcmField | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.1 | Unsigned32 | not-accessible | Indicates the tandem connection monitoring field of the ODUk OH. Valid values are integers from 1 to 6. |
| T/F jnxoptIfODUkTCodirectional | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.2 | TruthValue | not-accessible | Indicates the directionality of the ODUkT termination point with respect to the associated ODUk CTP. The value true(1) means that the sink part of the ODUkT TP extracts TCM data from the signal at the input to the ODUk CTP sink and the source part of the ODUkT TP inserts TCM data into the signal at the output of the ODUk CTP source. The value false(2) means that the sink part of the ODUkT TP extracts TCM data from the signal at the output of the ODUk CTP source and the source part of the ODUkT TP inserts TCM data into the signal at the input of the ODUk CTP sink. This attribute may assume either value when the corresponding instance of jnxoptIfODUkTtpPresent has the value false(2). When the value of the corresponding instance of jnxoptIfODUkTtpPresent is true(1) then the only value allowed for this attribute is true(1). |
| JNX jnxoptIfODUkTTraceIdentifierTransmitted | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.3 | JnxoptIfTxTI | read-create | The trace identifier transmitted. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value false(2), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases. |
| JNX jnxoptIfODUkTDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.4 | JnxoptIfExDAPI | read-create | The DAPI expected by the receiver. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when jnxoptIfODUkTTIMDetMode has the value off(1). |
| JNX jnxoptIfODUkTSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.5 | JnxoptIfExSAPI | read-create | The SAPI expected by the receiver. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when jnxoptIfODUkTTIMDetMode has the value off(1). |
| JNX jnxoptIfODUkTTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.6 | JnxoptIfAcTI | read-only | The actual trace identifier accepted. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The value of this object is unspecified when jnxoptIfODUkTCurrentStatus indicates a near-end defect (i.e., oci(0), lck(1), ssf(5)) that prevents extraction of the trace message. |
| JNX jnxoptIfODUkTTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.7 | JnxoptIfTIMDetMode | read-create | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is off(1). |
| T/F jnxoptIfODUkTTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.8 | TruthValue | read-create | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when jnxoptIfODUkTTIMDetMode has the value off(1). The default value of this object is false(2). |
| JNX jnxoptIfODUkTDEGThr | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.9 | JnxoptIfDEGThr | read-create | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to jnxoptIfODUkTDEGThr. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). |
| JNX jnxoptIfODUkTDEGM | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.10 | JnxoptIfDEGM | read-create | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if jnxoptIfODUkTDEGM consecutive bad PM Seconds are detected. This object is applicable only to the following three cases. (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is 7 (See ITU-T G.7710). |
| INT jnxoptIfODUkTSinkMode | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.11 | INTEGER | read-create | This variable specifies the TCM mode at the entity. The value operational(1) means that TCM Overhead (TCMOH) processes (see ITU-T G.798) shall be performed and consequent actions for AIS, Trail Signal Fail (TSF), Trail Signal Degraded (TSD) shall be initiated in case of defects. The value monitor(2) means that TCMOH processes shall be performed but consequent actions for AIS, Trail Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be initiated in case of defects. This object is applicable only when the value of jnxoptIfODUkTtpPresent is false(2) and also either one of the following three cases holds: (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. |
| INT jnxoptIfODUkTSinkLockSignalAdminState | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.12 | INTEGER | read-create | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the sink direction. This object is applicable only when the value of jnxoptIfODUkTtpPresent is false(2) and also either one of the following three cases holds: (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. |
| INT jnxoptIfODUkTSourceLockSignalAdminState | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.13 | INTEGER | read-create | Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction. This object is applicable only when either one of the following three cases holds: (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value false(2), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases. |
| BIT jnxoptIfODUkTCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.14 | Bits | read-only | Indicates the defect condition of the entity, if any. This object is applicable only when either one of the following three cases holds: (i) jnxoptIfODUkDirectionality has the value bidirectional(3), or (ii) jnxoptIfODUkDirectionality has the value sink(1) and jnxoptIfODUkTCodirectional has the value true(1), or (iii) jnxoptIfODUkDirectionality has the value source(3) and jnxoptIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. |
| ROW jnxoptIfODUkTRowStatus | 1.3.6.1.4.1.2636.3.73.1.1.9.1.1.15 | RowStatus | read-create | This columnar object is used for creating and deleting a conceptual row of the jnxoptIfODUkT config table. It is used to model the addTCM and removeTCM operations of an ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined in ITU-T G.874.1. Setting RowStatus to createAndGo or createAndWait implies addTCM. Setting RowStatus to destroy implies removeTCM. Successful addition/removal of TCM will result in updating the jnxoptIfODUkTcmFieldsInUse and jnxoptIfODUkPositionSeqCurrentSize variables and the jnxoptIfODUkPositionSeqTable table of the associated ODUk entry in the jnxoptIfODUkConfigTable. |
| jnxoptIfODUkTNimConfigTable | 1.3.6.1.4.1.2636.3.73.1.1.9.2 | not-accessible | A table of ODUkTNim configuration information. | |
| jnxoptIfODUkTNimConfigEntry | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1 | not-accessible | A conceptual row that contains ODUkTNim configuration information of an interface. Each instance must correspond to an instance of jnxoptIfODUkConfigEntry. Rows in this table are mutually exclusive with rows in the ODUkT config table -- in other words, this row object may not be instantiated for a given pair of ifIndex and TCM field values if a corresponding instance of jnxoptIfODUkTConfigEntry already exists. Instances of this conceptual row persist across agent restarts, and read-create columns other than the status column may be modified while the row is active. | |
| U32 jnxoptIfODUkTNimTcmField | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.1 | Unsigned32 | not-accessible | Indicates the tandem connection monitoring field of the ODUk OH on which non-intrusive monitoring is performed. Valid values are integers from 1 to 6. |
| JNX jnxoptIfODUkTNimDirectionality | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.2 | JnxoptIfSinkOrSource | not-accessible | Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of jnxoptIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction TCM signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP. |
| JNX jnxoptIfODUkTNimDAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.3 | JnxoptIfExDAPI | read-create | The DAPI expected by the receiver. This object has no effect if jnxoptIfODUkTNimTIMDetMode has the value off(1) or sapi(3). |
| JNX jnxoptIfODUkTNimSAPIExpected | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.4 | JnxoptIfExSAPI | read-create | The SAPI expected by the receiver. This object has no effect if jnxoptIfODUkTNimTIMDetMode has the value off(1) or dapi(2). |
| JNX jnxoptIfODUkTNimTraceIdentifierAccepted | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.5 | JnxoptIfAcTI | read-only | The actual trace identifier accepted. The value of this object is unspecified if jnxoptIfODUkTNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if jnxoptIfODUkTNimRowStatus has any value other than active(1). |
| JNX jnxoptIfODUkTNimTIMDetMode | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.6 | JnxoptIfTIMDetMode | read-create | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. |
| T/F jnxoptIfODUkTNimTIMActEnabled | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.7 | TruthValue | read-create | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. |
| JNX jnxoptIfODUkTNimDEGThr | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.8 | JnxoptIfDEGThr | read-create | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to jnxoptIfODUkTNimDEGThr. |
| JNX jnxoptIfODUkTNimDEGM | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.9 | JnxoptIfDEGM | read-create | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if jnxoptIfODUkTNimDEGM consecutive bad PM Seconds are detected. |
| BIT jnxoptIfODUkTNimCurrentStatus | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.10 | Bits | read-only | Indicates the defect condition of the entity, if any. The value of this object is unspecified if jnxoptIfODUkTNimRowStatus has any value other than active(1). |
| ROW jnxoptIfODUkTNimRowStatus | 1.3.6.1.4.1.2636.3.73.1.1.9.2.1.11 | RowStatus | read-create | This columnar object is used for creating and deleting a conceptual row of the jnxoptIfODUkTNim config table. It is used to model the addTCM and removeTCM operations of an ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection monitoring as defined in ITU-T G.874.1. Setting RowStatus to createAndGo or createAndWait implies addTCM. Setting RowStatus to destroy implies removeTCM. Successful addition/removal of Nim TCM will result in updating the jnxoptIfODUkPositionSeqCurrentSize variable and the jnxoptIfODUkPositionSeqTable table of the associated ODUk entry in the jnxoptIfODUkConfigTable. |
| jnxoptIfConfs | 1.3.6.1.4.1.2636.3.73.1.2 | |||
| jnxoptIfGroups | 1.3.6.1.4.1.2636.3.73.1.2.1 | |||
| jnxoptIfOTMnGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.1 | A collection of OTMn structure information objects. | ||
| jnxoptIfPerfMonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.2 | A collection of performance monitoring interval objects. | ||
| jnxoptIfOTSnCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.3 | A collection of configuration objects applicable to all OTSn interfaces. | ||
| jnxoptIfOTSnSourceGroupFull | 1.3.6.1.4.1.2636.3.73.1.2.1.4 | A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support source functions. | ||
| jnxoptIfOTSnAPRStatusGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.5 | A collection of objects applicable to OTSn interfaces that support Automatic Power Reduction functions. | ||
| jnxoptIfOTSnAPRControlGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.6 | A collection of objects applicable to OTSn interfaces that provide Automatic Power Reduction control functions. | ||
| jnxoptIfOTSnSinkGroupBasic | 1.3.6.1.4.1.2636.3.73.1.2.1.7 | A collection of configuration objects applicable to all OTSn interfaces that support sink functions. | ||
| jnxoptIfOTSnSinkGroupFull | 1.3.6.1.4.1.2636.3.73.1.2.1.8 | A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support sink functions. | ||
| jnxoptIfOTSnSinkPreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.9 | A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support sink functions. | ||
| jnxoptIfOTSnSinkPreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.10 | A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support sink functions. | ||
| jnxoptIfOTSnSourcePreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.11 | A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support source functions. | ||
| jnxoptIfOTSnSourcePreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.12 | A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support source functions. | ||
| jnxoptIfOMSnCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.13 | A collection of configuration objects applicable to all OMSn interfaces. | ||
| jnxoptIfOMSnSinkGroupBasic | 1.3.6.1.4.1.2636.3.73.1.2.1.14 | A collection of configuration objects applicable to all OMSn interfaces that support sink functions. | ||
| jnxoptIfOMSnSinkPreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.15 | A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support sink functions. | ||
| jnxoptIfOMSnSinkPreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.16 | A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that support sink functions. | ||
| jnxoptIfOMSnSourcePreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.17 | A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support source functions. | ||
| jnxoptIfOMSnSourcePreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.18 | A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that that support source functions. | ||
| jnxoptIfOChGroupCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.19 | A collection of configuration objects applicable to all OChGroup interfaces. | ||
| jnxoptIfOChGroupSinkPreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.20 | A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support sink functions. | ||
| jnxoptIfOChGroupSinkPreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.21 | A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that support sink functions. | ||
| jnxoptIfOChGroupSourcePreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.22 | A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support source functions. | ||
| jnxoptIfOChGroupSourcePreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.23 | A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that that support source functions. | ||
| jnxoptIfOChCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.24 | A collection of configuration objects applicable to all OCh interfaces. | ||
| jnxoptIfOChSinkGroupBasic | 1.3.6.1.4.1.2636.3.73.1.2.1.25 | A collection of configuration objects applicable to all OCh interfaces that support sink functions. | ||
| jnxoptIfOChSinkPreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.26 | A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support sink functions. | ||
| jnxoptIfOChSinkPreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.27 | A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support sink functions. | ||
| jnxoptIfOChSourcePreOtnPMGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.28 | A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support source functions. | ||
| jnxoptIfOChSourcePreOtnPMThresholdGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.29 | A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support source functions. | ||
| jnxoptIfOTUkCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.30 | A collection of configuration objects applicable to all OTUk interfaces. | ||
| jnxoptIfOTUkSourceGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.31 | A collection of configuration objects applicable to OTUk interfaces that support source functions. | ||
| jnxoptIfOTUkSinkGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.32 | A collection of configuration objects applicable to OTUk interfaces that support sink functions. | ||
| jnxoptIfGCC0Group | 1.3.6.1.4.1.2636.3.73.1.2.1.33 | A collection of GCC0 configuration objects. | ||
| jnxoptIfODUkGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.34 | A collection of configuration objects applicable to all ODUk interfaces. | ||
| jnxoptIfODUkTtpSourceGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.35 | A collection of configuration objects applicable to all interfaces that support ODUk trail termination source functions. | ||
| jnxoptIfODUkTtpSinkGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.36 | A collection of ODUk configuration objects applicable to all interfaces that support ODUk trail termination sink functions. | ||
| jnxoptIfODUkNimGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.37 | A collection of ODUk Nim configuration objects. | ||
| jnxoptIfGCC12Group | 1.3.6.1.4.1.2636.3.73.1.2.1.38 | A collection of GCC12 configuration objects. | ||
| jnxoptIfODUkTCommonGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.39 | A collection of configuration objects applicable to all ODUkT instances. | ||
| jnxoptIfODUkTSourceGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.40 | A collection of configuration objects applicable to all ODUkT instances that provide source functions. | ||
| jnxoptIfODUkTSinkGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.41 | A collection of configuration objects applicable to all ODUkT instances that provide sink functions. | ||
| jnxoptIfODUkTSinkGroupCtp | 1.3.6.1.4.1.2636.3.73.1.2.1.42 | A collection of configuration objects applicable to ODUkT instances not colocated with an ODUk TTP that provide sink functions. | ||
| jnxoptIfODUkTNimGroup | 1.3.6.1.4.1.2636.3.73.1.2.1.43 | A collection of ODUkT Nim configuration objects. | ||
| jnxoptIfCompl | 1.3.6.1.4.1.2636.3.73.1.2.2 | |||
| jnxoptIfOtnConfigCompl | 1.3.6.1.4.1.2636.3.73.1.2.2.1 | Implementation requirements for the OTN configuration functions defined in this MIB module. | ||
| jnxoptIfPreOtnPMCompl | 1.3.6.1.4.1.2636.3.73.1.2.2.2 | Implementation requirements for Pre-OTN performance monitoring functions defined in this MIB module. |
RFC description
Juniper OTN interface management for optical transport including pre-OTN and OTN interfaces.
Start monitoring Juniper Networks router with OTN/DWDM optical interfaces with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.