XEDIA-DS1-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › XEDIA-DS1-MIB

Organization: Xedia Corp.

Last Updated: 1998-06-17

Description: Xedia DS1 extension MIB adding proprietary line-status bit-string and additional configuration objects beyond the standard RFC 1406 DS1 MIB for Xedia devices

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is XEDIA-DS1-MIB?

XEDIA-DS1-MIB is a vendor-specific Xedia Corporation MIB that adds proprietary extensions to the standard DS1 MIB (RFC 1406) for T1/E1 interfaces on Xedia devices. Its xDsx1ConfigTable augments the standard dsx1ConfigEntry with a bit-string line-status object mirroring dsx1LineStatus but using the SNMPv2 BIT STRING type (covering alarms like far-end LOF, AIS, loss of frame, and loss of signal), a similarly-typed loopback-status bit string, CRC mode and line build-out/interface configuration, per-error-type injection counters for testing (line code violation, frame-bit, checksum, and PRBS error injection), a 32-channel timeslot mask, out-of-frame and frame-alignment-change counters, and loopback/test-code configuration supporting standard PRBS test patterns for circuit qualification. Monitoring it gives operators bit-level alarm visibility and the ability to run controlled error-injection and loopback tests on DS1 circuits, useful for qualifying a leased line or diagnosing intermittent T1/E1 framing issues before deploying production traffic. It depends on the IETF RFC1406-MIB for its base config/current/interval/total tables, and the XEDIA-DS1-MIB MIB is loaded alongside the standard DS1 MIB to fully decode these vendor-specific alarm and test objects.

IPNetwork Monitor allows you to monitor SNMP objects defined in XEDIA-DS1-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Xedia Corporation routers/access devices with DS1 (T1/E1) interfaces

Monitoring Examples

An operator checks the line-status bits for a T1 circuit and finds loss-of-frame or receive-AIS bits set alongside a climbing out-of-frame counter; combined with an incrementing frame-alignment-change counter, this points to a framing mismatch or a faulty span rather than a clean link, warranting a loopback test before further troubleshooting.

What Can Be Monitored

  • DS1 line status alarm bits (LOF, LOS, AIS, yellow alarm)
  • loopback status (local/remote, payload/line/framer/analog)
  • CRC mode and line build-out/interface configuration
  • error-injection counters (LCV, frame-bit, CRC, PRBS)
  • out-of-frame and frame-alignment-change counters
  • PRBS test-code pattern configuration
Imported Objects

From RFC1406-MIB

dsx1ConfigEntryOBJECT-TYPE
dsx1CurrentEntryOBJECT-TYPE
dsx1IntervalEntryOBJECT-TYPE
dsx1TotalEntryOBJECT-TYPE

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Counter32
Integer32
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

TEXTUAL-CONVENTION

From XEDIA-REG

xediaMibsOBJECT-IDENTITY

How to Use in IPNetwork Monitor

Example using xdsx1OutOfFrames OID:

Select a Xedia Corporation routers/access devices with DS1 (T1/E1) interface (bit-level alarm/loopback-test status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type xdsx1OutOfFrames into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of 'out of frame' errors. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Extends standard DS1 MIB with additional management objects for DS1 links in Xedia routing devices.

Start monitoring Xedia Corporation routers/access devices with DS1 (T1/E1) interfaces (bit-level alarm/loopback-test status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download XEDIA-DS1-MIB