Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is Wellfleet-MCT1-MIB?
Wellfleet-MCT1-MIB is a Wellfleet/Bay Networks vendor MIB for multi-channel T1 (MCT1) WAN interface cards, which allow a single T1 line to be split into multiple independently-configured DS0 channel groups. It exposes interface configuration, DS0 channel allocation/grouping, and physical-layer performance statistics such as errored seconds or line quality counters. For hardware monitoring, it is central to confirming that T1 line and channel hardware is operating correctly; tracking channel allocation changes and rising error counts can reveal a failing T1 span or framing/clocking problem. It complements the standard DS1/T1 MIB (RFC 2495/1406-family) with Wellfleet-specific channel and card management objects. It is deployed on Wellfleet/Bay Networks routers using channelized T1 WAN interfaces in enterprise or carrier access networks. Engineers can download the Wellfleet-MCT1-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in Wellfleet-MCT1-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Wellfleet/Bay Networks router
- multi-channel T1 WAN interface card
Monitoring Examples
An administrator would poll the DS0 channel allocation table to confirm each configured sub-channel is correctly mapped and active, and watch T1 line performance counters for errored seconds or loss-of-signal events. A rising error count on one DS0 channel while others remain clean would point to a localized line or hardware fault on that channel. No sample object names were provided for this MIB, so this description is inferred from the stated short description.
What Can Be Monitored
- DS0 channel allocation
- T1 line error counters
- channel configuration status
- T1 interface performance statistics
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge |
From RFC1213-MIB
| DisplayString |
From Wellfleet-COMMON-MIB
| wfMcT1Group | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| wfMcT1ModTable | 1.3.6.1.4.1.18.3.4.8.1 | not-accessible | MCT1 MOD record - Contains MCT1 module Configuration parameters | |
| wfMcT1ModEntry | 1.3.6.1.4.1.18.3.4.8.1.1 | not-accessible | An entry in the MCT1 Base table | |
| INT wfMcT1ModDelete | 1.3.6.1.4.1.18.3.4.8.1.1.1 | INTEGER | read-write | Create/Delete parameter |
| INT wfMcT1ModDisable | 1.3.6.1.4.1.18.3.4.8.1.1.2 | INTEGER | read-write | Enable/Disable parameter |
| INT wfMcT1ModSlot | 1.3.6.1.4.1.18.3.4.8.1.1.3 | INTEGER | read-only | Instance ID slot, filled in by driver |
| INT wfMcT1ModPrimaryClock | 1.3.6.1.4.1.18.3.4.8.1.1.4 | INTEGER | read-write | Specifies the primary source for T1 transmit timing. Both T1 ports use the same T1 transmit timing source. The options for T1 timing source are internal timing source, loop timing from either T1 port and an external timing source. |
| INT wfMcT1ModSecondaryClock | 1.3.6.1.4.1.18.3.4.8.1.1.5 | INTEGER | read-write | Specifies the secondary source for T1 transmit timing. During normal operation T1 transmit timing is derived from the primary timing source. If the primary timing source fails, the software switches to secondary timing source. |
| INT wfMcT1ModCurrentClock | 1.3.6.1.4.1.18.3.4.8.1.1.6 | INTEGER | read-only | Indicates the clock source currently in use |
| INT wfMcT1ModExtClockOperational | 1.3.6.1.4.1.18.3.4.8.1.1.7 | INTEGER | read-only | Indicates whether the External clock is operational |
| INT wfMcT1ModLoop0ClockOperational | 1.3.6.1.4.1.18.3.4.8.1.1.8 | INTEGER | read-only | Indicates whether the timing source from port 1 is operational |
| INT wfMcT1ModLoop1ClockOperational | 1.3.6.1.4.1.18.3.4.8.1.1.9 | INTEGER | read-only | Indicates whether the timing source from port 2 is operational |
| INT wfMcT1ModRestart | 1.3.6.1.4.1.18.3.4.8.1.1.10 | INTEGER | read-write | Indicates Module gate should be restarted to read new configuration |
| wfMcT1Table | 1.3.6.1.4.1.18.3.4.8.2 | not-accessible | MCT1 line record - Contains MUNICH32 Configuration parameters | |
| wfMcT1Entry | 1.3.6.1.4.1.18.3.4.8.2.1 | not-accessible | An entry in the MCT1 table | |
| INT wfMcT1Delete | 1.3.6.1.4.1.18.3.4.8.2.1.1 | INTEGER | read-write | Create/Delete parameter |
| INT wfMcT1Disable | 1.3.6.1.4.1.18.3.4.8.2.1.2 | INTEGER | read-write | Enable/Disable parameter |
| INT wfMcT1State | 1.3.6.1.4.1.18.3.4.8.2.1.3 | INTEGER | read-only | Line Driver state variable |
| INT wfMcT1Slot | 1.3.6.1.4.1.18.3.4.8.2.1.4 | INTEGER | read-only | Instance ID Slot, filled in by driver |
| INT wfMcT1Connector | 1.3.6.1.4.1.18.3.4.8.2.1.5 | INTEGER | read-only | Instance ID Connector, filled in by driver |
| INT wfMcT1OperationMode | 1.3.6.1.4.1.18.3.4.8.2.1.6 | INTEGER | read-write | An option to generate and analyze specific test patterns is provided in BERT mode of operation. Only one T1 port can be in BERT mode at a time. This attribute selects normal or BERT mode of operation |
| INT wfMcT1Mtu | 1.3.6.1.4.1.18.3.4.8.2.1.7 | INTEGER | read-write | MTU parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded. |
| INT wfMcT1MunichVersion | 1.3.6.1.4.1.18.3.4.8.2.1.8 | INTEGER | read-only | Specifies version number of the MUNICH chip used |
| INT wfMcT1Dsx1LineType | 1.3.6.1.4.1.18.3.4.8.2.1.9 | INTEGER | read-write | Selects between the two framing formats supported - D4 and ESF. The sailent differences between the two formats are the number of frames per superframe and the use of F-bit position. |
| INT wfMcT1Dsx1ZeroCoding | 1.3.6.1.4.1.18.3.4.8.2.1.10 | INTEGER | read-write | Selects between the two Zero Code Suppression formats used on the link. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes. |
| INT wfMcT1Dsx1LoopbackConfig | 1.3.6.1.4.1.18.3.4.8.2.1.11 | INTEGER | read-only | Indicates the loopback configuration of the T1 interface. The interface can be in the following loopback states: Payload loopback and Line loopback or no loopback. The loopbacks can be initiated by the manager of this device or by the far end. The loopbacks initiated by the far end are NETREQPAYLOADLOOP and NETREQLINELOOP. |
| INT wfMcT1Dsx1LineStatus | 1.3.6.1.4.1.18.3.4.8.2.1.12 | INTEGER | read-only | Indicates the line status of the T1 interface. It contains loopback state and alarm state information. The Dsx1LineStatus is a bit map therefore it can represent multiple loopback and alarm states simultaneously. |
| INT wfMcT1Dsx1SetupAlarmThreshold | 1.3.6.1.4.1.18.3.4.8.2.1.13 | INTEGER | read-write | Specifies setup time for performance failure conditions, in seconds. When a performance defect is present for greater than the time specified by this parameter a performance failure is registered and a message is logged. |
| INT wfMcT1Dsx1ClearAlarmThreshold | 1.3.6.1.4.1.18.3.4.8.2.1.14 | INTEGER | read-write | Specifies clear time for performance failure conditions, in seconds. When a performance failure condition has been cleared for greater than the time specified by this parameter then the failure cleared condition is registered and a message is logged. |
| INT wfMcT1Dsx1SignalLevel | 1.3.6.1.4.1.18.3.4.8.2.1.15 | INTEGER | read-write | Specifies T1 transmit power level, in terms of DB. They translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft |
| INT wfMcT1LoopbackDisable | 1.3.6.1.4.1.18.3.4.8.2.1.16 | INTEGER | read-write | The MCT1 link module is capable of detecting loop up and loop down codes received from the far end. This parameter enables or disbales loop up/down code detection circuitry |
| INT wfMcT1Dsx1FDLOperationMode | 1.3.6.1.4.1.18.3.4.8.2.1.17 | INTEGER | read-write | Select between the two FDL modes of operation. The AT&T mode, 54016 is based on AT&T publication 54015-1989. The ANSI mode, T1403 is based on ANSI publication T1.403-1989 |
| INT wfMcT1BertTxOutputLevel | 1.3.6.1.4.1.18.3.4.8.2.1.18 | INTEGER | read-write | Specifies T1 transmit power level, in terms of DB while the T1 port is in BERT mode. The power levels translate into cable length as follows: 0.0dB -> 0-133 ft 0.5dB -> 133-266 ft 0.8dB -> 266-399 ft 1.1dB -> 399-533 ft 1.5dB -> 533-655 ft |
| INT wfMcT1BertTestMode | 1.3.6.1.4.1.18.3.4.8.2.1.19 | INTEGER | read-write | Selects between the framing formats while in bert mode of operation. |
| INT wfMcT1BertLineCode | 1.3.6.1.4.1.18.3.4.8.2.1.20 | INTEGER | read-write | Selects between the two Zero Code Suppression formats used on the link while in BERT mode. In B8ZS coding, any outgoing stream of eight consecutive zeroes is replaced with a B8ZS code word. Any received B8ZS code is replaced with all zeroes. |
| INT wfMcT1BertTestPattern | 1.3.6.1.4.1.18.3.4.8.2.1.21 | INTEGER | read-write | When a T1 port is in BERT mode, it is capable of generating a set of known patterns. This paramater selects between those patterns |
| INT wfMcT1BertSendAlarm | 1.3.6.1.4.1.18.3.4.8.2.1.22 | INTEGER | read-write | Specifies a blue or yellow alarm to be transmitted while in BERT mode. |
| INT wfMcT1DS2282Version | 1.3.6.1.4.1.18.3.4.8.2.1.23 | INTEGER | read-only | Specifies version number of DS2282 chip |
| INT wfMcT1Restart | 1.3.6.1.4.1.18.3.4.8.2.1.24 | INTEGER | read-write | Indicates Port gate should be restarted to read new configuration |
| INT wfMcT1Loopback | 1.3.6.1.4.1.18.3.4.8.2.1.25 | INTEGER | read-write | Selects line or payload loopback to be activated locally |
| INT wfMcT1FDLTargetAddress | 1.3.6.1.4.1.18.3.4.8.2.1.26 | INTEGER | read-write | Selects between the two FDL target address modes |
| wfMcT1ConfigTable | 1.3.6.1.4.1.18.3.4.8.3 | not-accessible | MCT1 configuration record - Contains MUNICH32 and Framer write only Configuration parameters | |
| wfMcT1ConfigEntry | 1.3.6.1.4.1.18.3.4.8.3.1 | not-accessible | An entry in the MCT1 Config table | |
| INT wfMcT1ConfigSlot | 1.3.6.1.4.1.18.3.4.8.3.1.1 | INTEGER | read-only | Instance ID Slot, filled in by driver |
| INT wfMcT1ConfigConnector | 1.3.6.1.4.1.18.3.4.8.3.1.2 | INTEGER | read-only | Instance ID Connector, filled in by driver |
| INT wfMcT1BertRestart | 1.3.6.1.4.1.18.3.4.8.3.1.3 | INTEGER | read-write | Reset counters on BERT device |
| INT wfMcT1BertPayldLb | 1.3.6.1.4.1.18.3.4.8.3.1.4 | INTEGER | read-write | Selects a payload loopback code to be sent to the far end by the FDL while in BERT mode. It can be a payload loopback activate or deactivate code. |
| INT wfMcT1BertLineLb | 1.3.6.1.4.1.18.3.4.8.3.1.5 | INTEGER | read-write | Selects a line loopback code to be sent to the far end while in BERT mode. It can be a line loopback activate or deactivate code using the hardware on the MCT1 board or it can be a code sent by the FDL. |
| INT wfMcT1BertErrorInsert | 1.3.6.1.4.1.18.3.4.8.3.1.6 | INTEGER | read-write | Indicates that an error be injected into the transmitted data stream while in BERT mode. |
| INT wfMcT1Dsx1SendLoopCode | 1.3.6.1.4.1.18.3.4.8.3.1.7 | INTEGER | read-write | Selects a Loop Up/Down code to be sent to the remote end |
| INT wfMcT1Dsx1SendFDLCode | 1.3.6.1.4.1.18.3.4.8.3.1.8 | INTEGER | read-write | Selects an FDL code to be sent to the remote end |
| wfMcT1LineTable | 1.3.6.1.4.1.18.3.4.8.4 | not-accessible | MCT1 Channel record - Contains configuration parameters and statistics for MUNICH32 which are channel specific. | |
| wfMcT1LineEntry | 1.3.6.1.4.1.18.3.4.8.4.1 | not-accessible | An entry in the MCT1CHANNEL table | |
| INT wfMcT1LineDelete | 1.3.6.1.4.1.18.3.4.8.4.1.1 | INTEGER | read-write | Create/Delete parameter |
| INT wfMcT1LineDisable | 1.3.6.1.4.1.18.3.4.8.4.1.2 | INTEGER | read-write | Enable/Disable parameter |
| INT wfMcT1LineState | 1.3.6.1.4.1.18.3.4.8.4.1.3 | INTEGER | read-only | Line Driver state variable |
| INT wfMcT1LineSlot | 1.3.6.1.4.1.18.3.4.8.4.1.4 | INTEGER | read-only | Instance ID Slot, filled in by driver |
| INT wfMcT1LineConnector | 1.3.6.1.4.1.18.3.4.8.4.1.5 | INTEGER | read-only | Instance ID Connector, filled in by driver |
| INT wfMcT1LineLine | 1.3.6.1.4.1.18.3.4.8.4.1.6 | INTEGER | read-only | Line number for this line instance, filled in by driver. The line number corresponds to the position of the circuit, from 1 to 24, on the port. |
| INT wfMcT1LineCct | 1.3.6.1.4.1.18.3.4.8.4.1.7 | INTEGER | read-write | Circuit number for this line instance |
| INT wfMcT1LineBofl | 1.3.6.1.4.1.18.3.4.8.4.1.8 | INTEGER | read-write | Selects Breath of Life (BOFL) parameter. If selected, a BOFL packet is sent out on the wire as often as specifies by the wfMcT1LineBoflTmo parameter |
| INT wfMcT1LineBoflTmo | 1.3.6.1.4.1.18.3.4.8.4.1.9 | INTEGER | read-write | Indicates the time-period between BOFL packets |
| INT wfMcT1LineFractionalLpbk | 1.3.6.1.4.1.18.3.4.8.4.1.10 | INTEGER | read-write | Any circuit on this T1 port is capable of being put into loopback, i.e. data coming into that circuit from the wire is mirrorred back onto the wire. This parameter enables or disables this loopback feature on any circuit. |
| STR wfMcT1LineChannelAssignment | 1.3.6.1.4.1.18.3.4.8.4.1.11 | DisplayString | read-write | Lists the time-slots which constitute this channel. User types in a list of time-slots from 1 to 24 separated by commas |
| OCT wfMcT1LineMadr | 1.3.6.1.4.1.18.3.4.8.4.1.12 | OCTET STRING | read-only | Line MAC address, fixed - line driver fills in from the 48 bit address stored in the serial number prom. |
| INT wfMcT1LineWanProtocol | 1.3.6.1.4.1.18.3.4.8.4.1.13 | INTEGER | read-write | WAN protocol selection is provided via this parameter. The supported protocols can be selected per circuit. |
| INT wfMcT1LineService | 1.3.6.1.4.1.18.3.4.8.4.1.14 | INTEGER | read-write | Service type for this circuit. Supports raw HDLC mode. Does not support LLC1 at this time. LLC1 mode will prefix the HDLC address and control fields to the frame. May support LLC1 mode in the future |
| INT wfMcT1LineRateAdaption | 1.3.6.1.4.1.18.3.4.8.4.1.15 | INTEGER | read-write | Determines the number of bits and their bit positions within the time-slot. 64k selection uses all 8 bits in the time-slot. The two 56k selections use 7 of the 8 bits in the time-slot. 56k_MSB does not use the most significant bit and 56k_LSB does not use the least significant bit in the time-slot. |
| INT wfMcT1LineIFTF | 1.3.6.1.4.1.18.3.4.8.4.1.16 | INTEGER | read-write | Determines the Interframe time fill character to be transmitted by the MUNICH. In case of IFTF_FLAGS, 0x7E is sent and in case of IFTF_IDLES 0xff is sent as the interframe timefill characters. |
| INT wfMcT1LineCRCSize | 1.3.6.1.4.1.18.3.4.8.4.1.17 | INTEGER | read-write | Determines the CRC Size. When CRC32 is selected a 32 bit CRC is appended to the frame being transmitted and a 32 bit CRC check is performed on the received frame. When CRC16 is selected, a 16 bit CRC is appended to the transmitted frame and a 16 bit CRC is performed. on the received frame. |
| CTR wfMcT1LineRxOctets | 1.3.6.1.4.1.18.3.4.8.4.1.18 | Counter | read-only | Number of octets received without error |
| CTR wfMcT1LineRxFrames | 1.3.6.1.4.1.18.3.4.8.4.1.19 | Counter | read-only | Number of frames received without error |
| CTR wfMcT1LineTxOctets | 1.3.6.1.4.1.18.3.4.8.4.1.20 | Counter | read-only | Number of octets transmitted without error |
| CTR wfMcT1LineTxFrames | 1.3.6.1.4.1.18.3.4.8.4.1.21 | Counter | read-only | Number of frames transmitted without error |
| CTR wfMcT1LineRxErrors | 1.3.6.1.4.1.18.3.4.8.4.1.22 | Counter | read-only | Number of receive errors |
| CTR wfMcT1LineTxErrors | 1.3.6.1.4.1.18.3.4.8.4.1.23 | Counter | read-only | Number of transmission errors |
| CTR wfMcT1LineLackRxResources | 1.3.6.1.4.1.18.3.4.8.4.1.24 | Counter | read-only | Number of Rx frames dropped due to lack of buffer resources |
| CTR wfMcT1LineLackTxResources | 1.3.6.1.4.1.18.3.4.8.4.1.25 | Counter | read-only | Number of Tx frames dropped due to lack of buffer resources |
| CTR wfMcT1LineTxUnderflows | 1.3.6.1.4.1.18.3.4.8.4.1.26 | Counter | read-only | Number of Tx frames dropped due to Transmit underflow |
| CTR wfMcT1LineRxOverflows | 1.3.6.1.4.1.18.3.4.8.4.1.27 | Counter | read-only | Number of Rx frames dropped due to Receive overflow |
| CTR wfMcT1LineRxNullFrames | 1.3.6.1.4.1.18.3.4.8.4.1.28 | Counter | read-only | Number of short frames received (with no data bytes) |
| CTR wfMcT1LineRxShortFrames | 1.3.6.1.4.1.18.3.4.8.4.1.29 | Counter | read-only | Number of short frames received (less than or equal to two data bytes) |
| CTR wfMcT1LineRxLossSyncs | 1.3.6.1.4.1.18.3.4.8.4.1.30 | Counter | read-only | Loss of synchronization on receiver |
| CTR wfMcT1LineRxCRCErrors | 1.3.6.1.4.1.18.3.4.8.4.1.31 | Counter | read-only | CRC error received |
| CTR wfMcT1LineRxNonOctetBits | 1.3.6.1.4.1.18.3.4.8.4.1.32 | Counter | read-only | Non-Octet bits received in frame |
| CTR wfMcT1LineRxLongFrames | 1.3.6.1.4.1.18.3.4.8.4.1.33 | Counter | read-only | Frame longer than MFL received |
| CTR wfMcT1LineRxAbortFrames | 1.3.6.1.4.1.18.3.4.8.4.1.34 | Counter | read-only | Aborted frame received |
| CTR wfMcT1LineRxDescOverflows | 1.3.6.1.4.1.18.3.4.8.4.1.35 | Counter | read-only | Receive overflow on chip buffer |
| INT wfMcT1LineTurboBofl | 1.3.6.1.4.1.18.3.4.8.4.1.36 | INTEGER | read-write | DEBUG parameter - Turbo bofl enabled or disabled |
| INT wfMcT1LineBoflNum | 1.3.6.1.4.1.18.3.4.8.4.1.37 | INTEGER | read-write | DEBUG parameter - Number of breath of life packets per breath of life |
| INT wfMcT1LineBoflLen | 1.3.6.1.4.1.18.3.4.8.4.1.38 | INTEGER | read-write | DEBUG parameter - breath of life packet length |
| CTR wfMcT1LineRxIntProcs | 1.3.6.1.4.1.18.3.4.8.4.1.39 | Counter | read-only | Receive Interrupt processing count |
| CTR wfMcT1LineTxIntProcs | 1.3.6.1.4.1.18.3.4.8.4.1.40 | Counter | read-only | Tx interrupt processing count |
| CTR wfMcT1LineRxPktCorruptions | 1.3.6.1.4.1.18.3.4.8.4.1.41 | Counter | read-only | Corruption check on receive |
| CTR wfMcT1LineRxReplenMisses | 1.3.6.1.4.1.18.3.4.8.4.1.42 | Counter | read-only | Count of number of packet buffer misses while attempting to replenish driver receive ring |
| CTR wfMcT1LineRxIFCs | 1.3.6.1.4.1.18.3.4.8.4.1.43 | Counter | read-only | Number of times the device changes its interframe time-fill |
| INT wfMcT1LineCfgTxQueueLength | 1.3.6.1.4.1.18.3.4.8.4.1.44 | INTEGER | read-write | Configured transmit queue length |
| INT wfMcT1LineCfgRxQueueLength | 1.3.6.1.4.1.18.3.4.8.4.1.45 | INTEGER | read-write | Configured receive queue length |
| INT wfMcT1LineTxQueueLength | 1.3.6.1.4.1.18.3.4.8.4.1.46 | INTEGER | read-only | Current transmit queue length |
| INT wfMcT1LineRxQueueLength | 1.3.6.1.4.1.18.3.4.8.4.1.47 | INTEGER | read-only | Current Receive queue length |
| INT wfMcT1LineTxQueueEmpty | 1.3.6.1.4.1.18.3.4.8.4.1.48 | INTEGER | read-only | The number of times the transmit ring is found empty when transmitting packets |
| INT wfMcT1LineMtu | 1.3.6.1.4.1.18.3.4.8.4.1.49 | INTEGER | read-only | MTU read-only parameter. Specifies the largest frame size that can be received by the MCT1 link module. Any received frame which is larger than the MTU will be discarded. Can be set in MCT1Entry TABLE by the user |
| INT wfMcT1LineRestart | 1.3.6.1.4.1.18.3.4.8.4.1.50 | INTEGER | read-write | Indicates channel gate should be restarted to read new configuration |
| INT wfMcT1LineLineNumber | 1.3.6.1.4.1.18.3.4.8.4.1.51 | INTEGER | read-write | line number for this line instance |
| wfMcT1Dsx1CurrentTable | 1.3.6.1.4.1.18.3.4.8.5 | not-accessible | The MCT1_DSX1 Current table | |
| wfMcT1Dsx1CurrentEntry | 1.3.6.1.4.1.18.3.4.8.5.1 | not-accessible | per circuit MCT1_DSX1 current objects - wfMcT1Dsx1CurrentIndex corresponds to Wellfleet circuit number | |
| INT wfMcT1Dsx1CurrentSlot | 1.3.6.1.4.1.18.3.4.8.5.1.1 | INTEGER | read-only | this corresponds to the Wellfleet Slot number |
| INT wfMcT1Dsx1CurrentConnector | 1.3.6.1.4.1.18.3.4.8.5.1.2 | INTEGER | read-only | this corresponds to the Wellfleet Connector number |
| GAU wfMcT1Dsx1CurrentIntervalTimer | 1.3.6.1.4.1.18.3.4.8.5.1.3 | Gauge | read-only | the number of seconds in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentESs | 1.3.6.1.4.1.18.3.4.8.5.1.4 | Gauge | read-only | the number of errored seconds encountered by a DS1 interface in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentSESs | 1.3.6.1.4.1.18.3.4.8.5.1.5 | Gauge | read-only | the number of severely errored seconds in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentBESs | 1.3.6.1.4.1.18.3.4.8.5.1.6 | Gauge | read-only | the number of bursty errored seconds in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentUASs | 1.3.6.1.4.1.18.3.4.8.5.1.7 | Gauge | read-only | the number of unavailable seconds in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentCSSs | 1.3.6.1.4.1.18.3.4.8.5.1.8 | Gauge | read-only | the number of Controlled Slip seconds in the current 15 minute interval |
| GAU wfMcT1Dsx1CurrentBPVs | 1.3.6.1.4.1.18.3.4.8.5.1.9 | Gauge | read-only | the number of bipolar violations in the current 15 minute interval |
| wfMcT1Dsx1IntervalTable | 1.3.6.1.4.1.18.3.4.8.6 | not-accessible | The MCT1_DSX1 Interval table | |
| wfMcT1Dsx1IntervalEntry | 1.3.6.1.4.1.18.3.4.8.6.1 | not-accessible | per circuit MCT1_DSX1 interval objects - wfMcT1Dsx1IntervalIndex corresponds to Wellfleet circuit number, wfMcT1Dsx1IntervalNumber is the numbered previous 15-minute interval | |
| INT wfMcT1Dsx1IntervalSlot | 1.3.6.1.4.1.18.3.4.8.6.1.1 | INTEGER | read-only | this corresponds to the Wellfleet Slot number |
| INT wfMcT1Dsx1IntervalConnector | 1.3.6.1.4.1.18.3.4.8.6.1.2 | INTEGER | read-only | this corresponds to the Wellfleet Connector number |
| INT wfMcT1Dsx1IntervalNumber | 1.3.6.1.4.1.18.3.4.8.6.1.3 | INTEGER | read-only | 1..96 where 1 is the most recent 15-minute interval and 96 is the least |
| GAU wfMcT1Dsx1IntervalESs | 1.3.6.1.4.1.18.3.4.8.6.1.4 | Gauge | read-only | the number of errored seconds in the specified interval |
| GAU wfMcT1Dsx1IntervalSESs | 1.3.6.1.4.1.18.3.4.8.6.1.5 | Gauge | read-only | the number of severely errored seconds in the specified interval |
| GAU wfMcT1Dsx1IntervalBESs | 1.3.6.1.4.1.18.3.4.8.6.1.6 | Gauge | read-only | the number of bursty errored seconds in the specified interval |
| GAU wfMcT1Dsx1IntervalUASs | 1.3.6.1.4.1.18.3.4.8.6.1.7 | Gauge | read-only | the number of unavailable seconds in the specified interval |
| GAU wfMcT1Dsx1IntervalCSSs | 1.3.6.1.4.1.18.3.4.8.6.1.8 | Gauge | read-only | the number of controlled slip seconds in the specified interval |
| GAU wfMcT1Dsx1IntervalBPVs | 1.3.6.1.4.1.18.3.4.8.6.1.9 | Gauge | read-only | the number of bipolar violations in the specified interval |
| wfMcT1Dsx1TotalTable | 1.3.6.1.4.1.18.3.4.8.7 | not-accessible | The MCT1_DSX1 Total table | |
| wfMcT1Dsx1TotalEntry | 1.3.6.1.4.1.18.3.4.8.7.1 | not-accessible | per circuit MCT1_DSX1 total objects - wfMcT1Dsx1TotalIndex corresponds to Wellfleet circuit number | |
| INT wfMcT1Dsx1TotalSlot | 1.3.6.1.4.1.18.3.4.8.7.1.1 | INTEGER | read-only | this corresponds to the Wellfleet Slot number |
| INT wfMcT1Dsx1TotalConnector | 1.3.6.1.4.1.18.3.4.8.7.1.2 | INTEGER | read-only | this corresponds to the Wellfleet Connector number |
| GAU wfMcT1Dsx1TotalVITR | 1.3.6.1.4.1.18.3.4.8.7.1.3 | Gauge | read-only | Indicates the number of valid 15 minute intervals in the previous 24 hour period |
| GAU wfMcT1Dsx1TotalESs | 1.3.6.1.4.1.18.3.4.8.7.1.4 | Gauge | read-only | The number of errored seconds encountered by the DS1 interface in the previous 24 hour interval |
| GAU wfMcT1Dsx1TotalSESs | 1.3.6.1.4.1.18.3.4.8.7.1.5 | Gauge | read-only | The number of severely errored seconds encountered by a DS1 interface in the previous 24 hour interval |
| GAU wfMcT1Dsx1TotalBESs | 1.3.6.1.4.1.18.3.4.8.7.1.6 | Gauge | read-only | The number of bursty errored seconds encountered by a DS1 interface in the previous 24 hour interval |
| GAU wfMcT1Dsx1TotalUASs | 1.3.6.1.4.1.18.3.4.8.7.1.7 | Gauge | read-only | The number of unavailable seconds encountered by by a DS1 interface in the previous 24 hour interval |
| GAU wfMcT1Dsx1TotalCSSs | 1.3.6.1.4.1.18.3.4.8.7.1.8 | Gauge | read-only | The number of controlled slip seconds encountered by a DS1 interface in the previous 24 hour interval |
| GAU wfMcT1Dsx1TotalBPVs | 1.3.6.1.4.1.18.3.4.8.7.1.9 | Gauge | read-only | The number of bipolar violations encountered by a DS1 interface in the previous 24 hour interval |
| wfMcT1AnsiTable | 1.3.6.1.4.1.18.3.4.8.8 | not-accessible | ANSI Statistics line record - This table contains the performance parameters for the ANSI register set | |
| wfMcT1AnsiEntry | 1.3.6.1.4.1.18.3.4.8.8.1 | not-accessible | An entry in the MCT1 Ansi table | |
| INT wfMcT1AnsiSlot | 1.3.6.1.4.1.18.3.4.8.8.1.1 | INTEGER | read-only | Instance ID Slot, filled in by driver |
| INT wfMcT1AnsiConnector | 1.3.6.1.4.1.18.3.4.8.8.1.2 | INTEGER | read-only | Instance ID Connector, filled in by driver |
| CTR wfMcT1AnsiCRCCounts | 1.3.6.1.4.1.18.3.4.8.8.1.3 | Counter | read-only | Counts CRC-6 error events |
| CTR wfMcT1AnsiBPVCounts | 1.3.6.1.4.1.18.3.4.8.8.1.4 | Counter | read-only | Counts bipolar violations |
| CTR wfMcT1AnsiOOFCounts | 1.3.6.1.4.1.18.3.4.8.8.1.5 | Counter | read-only | Counts out-of-frame error events |
| CTR wfMcT1AnsiFECounts | 1.3.6.1.4.1.18.3.4.8.8.1.6 | Counter | read-only | Counts errors in the FPS framing pattern |
| CTR wfMcT1AnsiESCounts | 1.3.6.1.4.1.18.3.4.8.8.1.7 | Counter | read-only | Counts errorred seconds |
| CTR wfMcT1AnsiSESCounts | 1.3.6.1.4.1.18.3.4.8.8.1.8 | Counter | read-only | Counts severly errorred seconds |
| CTR wfMcT1AnsiUASCounts | 1.3.6.1.4.1.18.3.4.8.8.1.9 | Counter | read-only | counts unavailable seconds |
| CTR wfMcT1AnsiPRMR0Counts | 1.3.6.1.4.1.18.3.4.8.8.1.10 | Counter | read-only | Counts PRMs that ewre received in the FDL in the last four seconds |
| CTR wfMcT1AnsiPRMR1Counts | 1.3.6.1.4.1.18.3.4.8.8.1.11 | Counter | read-only | Counts PRMs that ewre received in the FDL in the last four seconds |
| CTR wfMcT1AnsiPRMR2Counts | 1.3.6.1.4.1.18.3.4.8.8.1.12 | Counter | read-only | Counts PRMs that ewre received in the FDL in the last four seconds |
| CTR wfMcT1AnsiPRMR3Counts | 1.3.6.1.4.1.18.3.4.8.8.1.13 | Counter | read-only | Counts PRMs that ewre received in the FDL in the last four seconds |
| CTR wfMcT1AnsiPRMESCounts | 1.3.6.1.4.1.18.3.4.8.8.1.14 | Counter | read-only | Counts errorred seconds as reported in the Performance report messages |
| CTR wfMcT1AnsiPRMSESCounts | 1.3.6.1.4.1.18.3.4.8.8.1.15 | Counter | read-only | Counts severely errorred seconds as reported in the Performance report messages |
| CTR wfMcT1AnsiPRMECounts | 1.3.6.1.4.1.18.3.4.8.8.1.16 | Counter | read-only | Counts Performance report messages that are received in error |
| wfMcT1BertStatsTable | 1.3.6.1.4.1.18.3.4.8.9 | not-accessible | BERT Counter line record - This table contains the statistics for the BERT tester. | |
| wfMcT1BertStatsEntry | 1.3.6.1.4.1.18.3.4.8.9.1 | not-accessible | An entry in the MCT1 Bert Stats table | |
| INT wfMcT1BertStatsSlot | 1.3.6.1.4.1.18.3.4.8.9.1.1 | INTEGER | read-only | Instance ID Slot, filled in by driver |
| INT wfMcT1BertStatsConnector | 1.3.6.1.4.1.18.3.4.8.9.1.2 | INTEGER | read-only | Instance ID Connector, filled in by driver |
| CTR wfMcT1BertStatsBitErrors | 1.3.6.1.4.1.18.3.4.8.9.1.3 | Counter | read-only | Bit error counter |
| CTR wfMcT1BertStatsBits | 1.3.6.1.4.1.18.3.4.8.9.1.4 | Counter | read-only | Bit counter |
RFC description
Manages T1 multi-channel interface modules with clock selection and configuration on Wellfleet network devices.
Start monitoring Wellfleet/Bay Networks router, multi-channel T1 WAN interface card (DS0-channel/line-quality status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.