Wellfleet-MCT1-MIB :: wfMcT1ModSecondaryClock

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-MCT1-MIB › wfMcT1ModSecondaryClock

wfMcT1ModSecondaryClock

Module: Wellfleet-MCT1-MIB

OID (symbolic): Wellfleet-MCT1-MIB::wfMcT1ModSecondaryClock

OID (numeric): 1.3.6.1.4.1.18.3.4.8.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specifies the secondary source for T1 transmit timing. During normal operation T1 transmit timing is derived from the primary timing source. If the primary timing source fails, the software switches to secondary timing source.

What is wfMcT1ModSecondaryClock?

Selects the backup timing source the module falls back to automatically if the primary clock source fails, keeping T1 transmit timing synchronized without manual intervention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.8.1.1.5
snmpwalk -v2c -c public <target> Wellfleet-MCT1-MIB::wfMcT1ModSecondaryClock

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.8.1.1.5.1
snmpget -v2c -c public <target> Wellfleet-MCT1-MIB::wfMcT1ModSecondaryClock.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.8.1.1.5.1 i <value>

Start monitoring Wellfleet/Bay Networks router, multi-channel T1 WAN interface card (DS0-channel/line-quality status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-MCT1-MIB::wfMcT1ModSecondaryClock OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks router, multi-channel T1 WAN interface card (DS0-channel/line-quality status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4wfLineWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4.8wfMcT1GroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.4.8.1wfMcT1ModTableWellfleet-MCT1-MIB
1.3.6.1.4.1.18.3.4.8.1.1wfMcT1ModEntryWellfleet-MCT1-MIB
1.3.6.1.4.1.18.3.4.8.1.1.5wfMcT1ModSecondaryClockWellfleet-MCT1-MIB