Wellfleet-MCT1-MIB :: wfMcT1ModPrimaryClock

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Wellfleet-MCT1-MIB › wfMcT1ModPrimaryClock

wfMcT1ModPrimaryClock

Module: Wellfleet-MCT1-MIB

OID (symbolic): Wellfleet-MCT1-MIB::wfMcT1ModPrimaryClock

OID (numeric): 1.3.6.1.4.1.18.3.4.8.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Specifies the primary source for T1 transmit timing. Both T1 ports use the same T1 transmit timing source. The options for T1 timing source are internal timing source, loop timing from either T1 port and an external timing source.

What is wfMcT1ModPrimaryClock?

Selects the primary timing source both T1 ports on this module use for transmit clocking -- internal, external, or loop-timed from either port -- which an admin sets based on where the network's master clock reference is.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.4.8.1.1.4
snmpwalk -v2c -c public <target> Wellfleet-MCT1-MIB::wfMcT1ModPrimaryClock

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.4.8.1.1.4.1
snmpget -v2c -c public <target> Wellfleet-MCT1-MIB::wfMcT1ModPrimaryClock.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.18.3.4.8.1.1.4.1 i <value>

Start monitoring Wellfleet/Bay Networks router, multi-channel T1 WAN interface card (DS0-channel/line-quality status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-MCT1-MIB::wfMcT1ModPrimaryClock OID value, configure state conditions and alerts, and monitor any Wellfleet/Bay Networks router, multi-channel T1 WAN interface card (DS0-channel/line-quality status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18wellfleetCMU-MIB
1.3.6.1.4.1.18.3wfSwSeries7Wellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4wfLineWellfleet-COMMON-MIB
1.3.6.1.4.1.18.3.4.8wfMcT1GroupWellfleet-COMMON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18.3.4.8.1wfMcT1ModTableWellfleet-MCT1-MIB
1.3.6.1.4.1.18.3.4.8.1.1wfMcT1ModEntryWellfleet-MCT1-MIB