All MIBs › TRIPPLITE-PRODUCTS
Organization: Tripp Lite
Last Updated: 2016-06-22
Category: Tripp Lite Power Management, UPS and Power Management
Description: Defines Tripp Lite product OID registrations for UPS, PDU, and power management device families.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TRIPPLITE-PRODUCTS?
TRIPPLITE-PRODUCTS is a Tripp Lite proprietary MIB providing remote-management capabilities for Tripp Lite PowerAlert and related software across multiple device types. Its objects cover a device count, a device table (index, row status, type, manufacturer, model, name, ID, location, region, status), a device-identity table (protocol, comm-port type/name, firmware version, serial number, date installed, hardware version, current/total uptime), and a UPS-specific identity count. As a configuration/status MIB it lets an administrator confirm which devices are managed under Tripp Lite PowerAlert and their firmware/serial identity. It is deployed on Tripp Lite PowerAlert-managed devices (UPS and related equipment). Engineers can download the TRIPPLITE-PRODUCTS file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TRIPPLITE-PRODUCTS. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Tripp Lite PowerAlert-managed devices (UPS and related equipment)
Monitoring Examples
An administrator checks tlpDeviceStatus and tlpDeviceIdentFirmwareVersion to confirm a specific device's health and firmware under Tripp Lite PowerAlert management.
What Can Be Monitored
- managed-device status and firmware/serial identity
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| TimeTicks | |
| Unsigned32 | |
| enterprises |
From SNMPv2-TC
| DisplayString | |
| RowStatus | |
| TimeStamp | |
| TruthValue |
From TRIPPLITE
| tripplite | MODULE-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| tlpAgentAlarms | 1.3.6.1.4.1.850.1.3.3.1 | |||
| tlpAgentAttributes | 1.3.6.1.4.1.850.1.2.1.2 | |||
| tlpAgentAttributesAutostart | 1.3.6.1.4.1.850.1.2.1.2.2 | |||
| T/F tlpAgentAttributesAutostartFTP | 1.3.6.1.4.1.850.1.2.1.2.2.3 | TruthValue | read-only | Indicates whether the agent autostarts FTP services. |
| T/F tlpAgentAttributesAutostartHTTP | 1.3.6.1.4.1.850.1.2.1.2.2.1 | TruthValue | read-only | Indicates whether the agent autostarts HTTP services. |
| T/F tlpAgentAttributesAutostartHTTPS | 1.3.6.1.4.1.850.1.2.1.2.2.2 | TruthValue | read-only | Indicates whether the agent autostarts HTTPS services. |
| T/F tlpAgentAttributesAutostartSNMP | 1.3.6.1.4.1.850.1.2.1.2.2.8 | TruthValue | read-only | Indicates whether the agent autostarts SNMP services. |
| T/F tlpAgentAttributesAutostartSSHCLI | 1.3.6.1.4.1.850.1.2.1.2.2.7 | TruthValue | read-only | Indicates whether the agent autostarts SSH CLI services. |
| T/F tlpAgentAttributesAutostartSSHMenu | 1.3.6.1.4.1.850.1.2.1.2.2.6 | TruthValue | read-only | Indicates whether the agent autostarts SSH menu services. |
| T/F tlpAgentAttributesAutostartTelnetCLI | 1.3.6.1.4.1.850.1.2.1.2.2.5 | TruthValue | read-only | Indicates whether the agent autostarts Telnet CLI services. |
| T/F tlpAgentAttributesAutostartTelnetMenu | 1.3.6.1.4.1.850.1.2.1.2.2.4 | TruthValue | read-only | Indicates whether the agent autostarts Telnet menu services. |
| U32 tlpAgentAttributesFTPPort | 1.3.6.1.4.1.850.1.2.1.2.4.3 | Unsigned32 | read-only | The port used for FTP communications. |
| U32 tlpAgentAttributesHTTPPort | 1.3.6.1.4.1.850.1.2.1.2.4.1 | Unsigned32 | read-only | The port used for HTTP communications. |
| U32 tlpAgentAttributesHTTPSPort | 1.3.6.1.4.1.850.1.2.1.2.4.2 | Unsigned32 | read-only | The port used for HTTPS communications. |
| tlpAgentAttributesPorts | 1.3.6.1.4.1.850.1.2.1.2.4 | |||
| tlpAgentAttributesSnmp | 1.3.6.1.4.1.850.1.2.1.2.3 | |||
| U32 tlpAgentAttributesSNMPPort | 1.3.6.1.4.1.850.1.2.1.2.4.8 | Unsigned32 | read-only | The port used for SNMP communications. |
| U32 tlpAgentAttributesSNMPTrapPort | 1.3.6.1.4.1.850.1.2.1.2.4.9 | Unsigned32 | read-only | The port used for SNMP trap and notifications. |
| T/F tlpAgentAttributesSNMPv1Enabled | 1.3.6.1.4.1.850.1.2.1.2.3.1 | TruthValue | read-only | Indicates whether the agent will allow SNMPv1 connections. |
| T/F tlpAgentAttributesSNMPv2cEnabled | 1.3.6.1.4.1.850.1.2.1.2.3.2 | TruthValue | read-only | Indicates whether the agent will allow SNMPv2c connections. |
| T/F tlpAgentAttributesSNMPv3Enabled | 1.3.6.1.4.1.850.1.2.1.2.3.3 | TruthValue | read-only | Indicates whether the agent will allow SNMPv3 connections. |
| U32 tlpAgentAttributesSSHCLIPort | 1.3.6.1.4.1.850.1.2.1.2.4.7 | Unsigned32 | read-only | The port used for SSH CLI communications. |
| U32 tlpAgentAttributesSSHMenuPort | 1.3.6.1.4.1.850.1.2.1.2.4.6 | Unsigned32 | read-only | The port used for SSH Menu communications. |
| tlpAgentAttributesSupports | 1.3.6.1.4.1.850.1.2.1.2.1 | |||
| T/F tlpAgentAttributesSupportsFTP | 1.3.6.1.4.1.850.1.2.1.2.1.3 | TruthValue | read-only | Indicates whether the agent supports FTP connections. |
| T/F tlpAgentAttributesSupportsHTTP | 1.3.6.1.4.1.850.1.2.1.2.1.1 | TruthValue | read-only | Indicates whether the agent supports HTTP connections. |
| T/F tlpAgentAttributesSupportsHTTPS | 1.3.6.1.4.1.850.1.2.1.2.1.2 | TruthValue | read-only | Indicates whether the agent supports HTTPS connections. |
| T/F tlpAgentAttributesSupportsSNMP | 1.3.6.1.4.1.850.1.2.1.2.1.8 | TruthValue | read-only | Indicates whether the agent supports SNMP connections. |
| T/F tlpAgentAttributesSupportsSNMPTrap | 1.3.6.1.4.1.850.1.2.1.2.1.9 | TruthValue | read-only | Indicates whether the agent supports listening for SNMP traps. This is only applicable for network monitoring applications, PowerAlert Shutdown Agent for an example, that connect to a web card or PowerAlert Local and listen for outbound traps. As such, this value is not supported and will always return 2(false) for a web card or PowerAlert Local. |
| T/F tlpAgentAttributesSupportsSSHCLI | 1.3.6.1.4.1.850.1.2.1.2.1.7 | TruthValue | read-only | Indicates whether the agent supports SSH CLI connections. |
| T/F tlpAgentAttributesSupportsSSHMenu | 1.3.6.1.4.1.850.1.2.1.2.1.6 | TruthValue | read-only | Indicates whether the agent supports SSH menu connections. |
| T/F tlpAgentAttributesSupportsTelnetCLI | 1.3.6.1.4.1.850.1.2.1.2.1.5 | TruthValue | read-only | Indicates whether the agent supports Telnet CLI connections. |
| T/F tlpAgentAttributesSupportsTelnetMenu | 1.3.6.1.4.1.850.1.2.1.2.1.4 | TruthValue | read-only | Indicates whether the agent supports Telnet menu connections. |
| U32 tlpAgentAttributesTelnetCLIPort | 1.3.6.1.4.1.850.1.2.1.2.4.5 | Unsigned32 | read-only | The port used for Telnet CLI communications. |
| U32 tlpAgentAttributesTelnetMenuPort | 1.3.6.1.4.1.850.1.2.1.2.4.4 | Unsigned32 | read-only | The port used for Telnet Menu communications. |
| tlpAgentConfig | 1.3.6.1.4.1.850.1.2.2.1 | |||
| STR tlpAgentConfigCurrentTime | 1.3.6.1.4.1.850.1.2.2.1.2 | DisplayString | read-write | The current date and time of the system. |
| STR tlpAgentConfigRemoteRegistration | 1.3.6.1.4.1.850.1.2.2.1.1 | DisplayString | read-write | Registers an SNMP contact's IP address and the port on which the contact is listening for SNMP traps. Setting this value is used to CREATE a table entry in a non-standard way. Getting this value will return a string INADDR_ANY and any port number. The port number should always be included. When unregistering an SNMP contact, the requester's IP address should be provided with a port number of 0. When setting or unsetting this OID, the IP address string should never be 0 nor should it be empty. The registration uses its default community string to register each contact. To use a community other than the default, then it must be appended to the end of the string delimited with a comma. The address should be of the format 0.0.0.0:00000 for IPv4. If IPv6 is supported, use the bracket-enclosed format given in IETF RFC 2732 Section 2, with the following examples: [FEDC:BA98:7654:3210:FEDC:BA98:7654:3210]:80 [1080:0:0:0:8:800:200C:417A]:162 [3ffe:2a00:100:7031::1]:162 [1080::8:800:200C:417A]:162,myCommunity [::192.9.5.5]:162,myCommunity [::FFFF:129.144.52.38]:80 [2010:836B:4179::836B:4179]:162 |
| tlpAgentContacts | 1.3.6.1.4.1.850.1.2.3 | |||
| tlpAgentDetails | 1.3.6.1.4.1.850.1.2.1 | |||
| STR tlpAgentDriverVersion | 1.3.6.1.4.1.850.1.2.1.1.3 | DisplayString | read-only | The driver version of the agent software. |
| STR tlpAgentEmailContactAddress | 1.3.6.1.4.1.850.1.2.3.1.2.1.4 | DisplayString | read-write | The address of the email contact. |
| tlpAgentEmailContactEntry | 1.3.6.1.4.1.850.1.2.3.1.2.1 | not-accessible | An entry containing the details of an email contact. | |
| U32 tlpAgentEmailContactIndex | 1.3.6.1.4.1.850.1.2.3.1.2.1.1 | Unsigned32 | read-only | The table row index for the email contact. |
| STR tlpAgentEmailContactName | 1.3.6.1.4.1.850.1.2.3.1.2.1.3 | DisplayString | read-write | The name of the email contact. |
| ROW tlpAgentEmailContactRowStatus | 1.3.6.1.4.1.850.1.2.3.1.2.1.2 | RowStatus | read-write | Row status for the tlpAgentEmailContactTable. |
| tlpAgentEmailContacts | 1.3.6.1.4.1.850.1.2.3.1 | |||
| tlpAgentEmailContactTable | 1.3.6.1.4.1.850.1.2.3.1.2 | not-accessible | A list of email contact entries. The number of entries is given by the value of tlpAgentNumEmailContacts. | |
| tlpAgentIdent | 1.3.6.1.4.1.850.1.2.1.1 | |||
| STR tlpAgentMAC | 1.3.6.1.4.1.850.1.2.1.1.4 | DisplayString | read-only | The MAC Address of the agent. |
| U32 tlpAgentNumEmailContacts | 1.3.6.1.4.1.850.1.2.3.1.1 | Unsigned32 | read-only | The number of email contacts currently defined in the agent. |
| U32 tlpAgentNumSnmpContacts | 1.3.6.1.4.1.850.1.2.3.2.1 | Unsigned32 | read-only | The number of SNMP contacts currently defined in the agent. |
| STR tlpAgentSerialNum | 1.3.6.1.4.1.850.1.2.1.1.5 | DisplayString | read-only | Serial number of the web card providing the agent data. This value is only supported by a web card agent. PowerAlert for PC (PAL) agents do not support this value and will return ERROR_NO_SUCH_NAME. |
| tlpAgentSettings | 1.3.6.1.4.1.850.1.2.2 | |||
| STR tlpAgentSnmpContactAuthPassword | 1.3.6.1.4.1.850.1.2.3.2.2.1.9 | DisplayString | read-write | The authentication password to use for sending V3 traps to the SNMP contact. |
| tlpAgentSnmpContactEntry | 1.3.6.1.4.1.850.1.2.3.2.2.1 | not-accessible | An entry containing the details of an SNMP contact. | |
| U32 tlpAgentSnmpContactIndex | 1.3.6.1.4.1.850.1.2.3.2.2.1.1 | Unsigned32 | read-only | The table row index for the SNMP contact. |
| STR tlpAgentSnmpContactIpAddress | 1.3.6.1.4.1.850.1.2.3.2.2.1.4 | DisplayString | read-write | The IP address of the SNMP contact. |
| STR tlpAgentSnmpContactName | 1.3.6.1.4.1.850.1.2.3.2.2.1.3 | DisplayString | read-write | The name of the SNMP contact. |
| U32 tlpAgentSnmpContactPort | 1.3.6.1.4.1.850.1.2.3.2.2.1.5 | Unsigned32 | read-write | The port of the SNMP contact. |
| STR tlpAgentSnmpContactPrivPassword | 1.3.6.1.4.1.850.1.2.3.2.2.1.8 | DisplayString | read-write | The privacy password to use for sending V3 traps to the SNMP contact. |
| ROW tlpAgentSnmpContactRowStatus | 1.3.6.1.4.1.850.1.2.3.2.2.1.2 | RowStatus | read-write | Row status for the tlpAgentSnmpContactTable. |
| tlpAgentSnmpContacts | 1.3.6.1.4.1.850.1.2.3.2 | |||
| STR tlpAgentSnmpContactSecurityName | 1.3.6.1.4.1.850.1.2.3.2.2.1.7 | DisplayString | read-write | The security name for the SNMP contact. |
| INT tlpAgentSnmpContactSnmpVersion | 1.3.6.1.4.1.850.1.2.3.2.2.1.6 | INTEGER | read-write | The SNMP contact version to use for sending traps. |
| tlpAgentSnmpContactTable | 1.3.6.1.4.1.850.1.2.3.2.2 | not-accessible | A list of SNMP contact entries. The number of entries is given by the value of tlpAgentNumSnmpContacts. | |
| INT tlpAgentType | 1.3.6.1.4.1.850.1.2.1.1.1 | INTEGER | read-only | The type of PowerAlert engine providing this data. |
| STR tlpAgentUuid | 1.3.6.1.4.1.850.1.2.1.1.6 | DisplayString | read-only | Universally unique identifier for this host in the form 8-4-4-4-12 for a total of 36 characters (32 alphanumeric characters and four hyphens). For example: 550e8400-e29b-41d4-a716-446655440000. |
| STR tlpAgentVersion | 1.3.6.1.4.1.850.1.2.1.1.2 | DisplayString | read-only | The version of the agent software. |
| INT tlpAlarmAcknowledged | 1.3.6.1.4.1.850.1.3.2.1.9 | INTEGER | read-write | Denotes whether the alarm condition has been acknowledged. The agent will return notAcknowledged(1) if the condition has not been acknowledged, or acknowledged(2) when acknowledged. Writing the value acknowledged(2) for an alarm acknowledges the alarm condition. Each alarm condition must be cleared and acknowledged before it is removed from this table; therefore, even if acknowledged, the alarm will remain in this table until the alarm becomes inactive as denoted by tlpAlarmState. |
| tlpAlarmCommunicationsLost | 1.3.6.1.4.1.850.1.3.3.2.1 | A problem has been encountered in the communications between the agent and the device. | ||
| tlpAlarmControl | 1.3.6.1.4.1.850.1.3.4 | |||
| OID tlpAlarmControlDescr | 1.3.6.1.4.1.850.1.3.4.1.1.2 | OBJECT IDENTIFIER | read-only | A reference of the alarm description object. The object referenced should not be accessbile, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active. This will be the same object description of an alarm when in alarm as referenced by tlpAlarmDescr. |
| STR tlpAlarmControlDetail | 1.3.6.1.4.1.850.1.3.4.1.1.3 | DisplayString | read-only | A textual description of the alarm condition. This will be the same textual description of an alarm when in alarm as referenced by tlpAlarmDetail. |
| tlpAlarmControlEntry | 1.3.6.1.4.1.850.1.3.4.1.1 | not-accessible | An entry containing details for a particular alarm condition. | |
| U32 tlpAlarmControlIndex | 1.3.6.1.4.1.850.1.3.4.1.1.1 | Unsigned32 | read-only | The table row index for this alarm control entry for this device. The index of any one row represents the index of the alarm entry within the agent system. As such, the index values for any one device is not guaranteed to start with 1 or be numerically sequential. |
| INT tlpAlarmControlSeverity | 1.3.6.1.4.1.850.1.3.4.1.1.4 | INTEGER | read-write | The severity of this alarm, which can be configured as desired for each alarm condition. This will be the same severity used when in alarm as referenced by tlpAlarmType. |
| tlpAlarmControlTable | 1.3.6.1.4.1.850.1.3.4.1 | not-accessible | A list of alarm conditions supported for each device managed by this agent. This table contains zero, one, or many rows depending upon the number of available alarms managed by each device. | |
| OID tlpAlarmDescr | 1.3.6.1.4.1.850.1.3.2.1.2 | OBJECT IDENTIFIER | read-only | A reference of the alarm description object. The object referenced should not be accessbile, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active. |
| STR tlpAlarmDetail | 1.3.6.1.4.1.850.1.3.2.1.6 | DisplayString | read-only | A textual description of the alarm condition. |
| tlpAlarmEntry | 1.3.6.1.4.1.850.1.3.2.1 | not-accessible | An entry containing information application to a particular alarm. | |
| U32 tlpAlarmId | 1.3.6.1.4.1.850.1.3.2.1.1 | Unsigned32 | read-only | A unique identifier for an alarm condition. This value will remain constant for the duration of the alarm condition. |
| tlpAlarms | 1.3.6.1.4.1.850.1.3 | |||
| U32 tlpAlarmsPresent | 1.3.6.1.4.1.850.1.3.1 | Unsigned32 | read-only | The present number of active alarm conditions. |
| INT tlpAlarmState | 1.3.6.1.4.1.850.1.3.2.1.8 | INTEGER | read-only | The current state of this alarm condition. An active(1) alarm is a condition that currently exists. An inactive(2) alarm is a condition that no longer exists because the alarm either cleared or was resolved. Each alarm condition must be cleared and acknowledged before it is removed from this table (see tlpAlarmAcknowledged). |
| tlpAlarmsWellKnown | 1.3.6.1.4.1.850.1.3.3 | |||
| tlpAlarmTable | 1.3.6.1.4.1.850.1.3.2 | not-accessible | A list of alarm conditions for all devices managed by this agent. This table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect or conditions not acnowledged. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains (becomes inactive and is acknowledged). The agent creates the first row with tlpAlarmId equal to 1, and increments the value of tlpAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of tlpAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse (e.g., containing entries for rows 95, 100, 101, and 203) and the entries should not be assumed to be in chronological order because tlpAlarmId might have wrapped. The number of rows in the table at any given time is reflected by the value of tlpAlarmsPresent. | |
| OID tlpAlarmTableRef | 1.3.6.1.4.1.850.1.3.2.1.4 | OBJECT IDENTIFIER | read-only | This value references the OID of a table object applicable to the alarm condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the alarm condition applies. Example 1 -- The following sample values will be returned for a UPS on battery: tlpAlarmId 28 tlpAlarmDescr tlpUpsAlarmOnBattery tlpAlarmTime 12345678 tlpAlarmTableRef tlpDeviceTable tlpAlarmTableRowRef tlpDeviceIndex.2 tlpAlarmDetail On Battery tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged notAcknowledged In the above example, tlpAlarmTableRef references the device table and tlpAlarmTableRowRef references the 2nd managed device in that table. Example 2 -- The following sample values will be returned for a PDU with a load turned off: tlpAlarmId 46 tlpAlarmDescr tlpPduAlarmLoadOff tlpAlarmTime 12345678 tlpAlarmTableRef tlpPduOutletTable tlpAlarmTableRowRef tlpOutletIndex.1.4 tlpAlarmDetail Load Off tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged acknowledged In the above example, tlpAlarmTableRef references the pdu outlet table and tlpAlarmTableRowRef references the 4th outlet on the 1st managed device. |
| OID tlpAlarmTableRowRef | 1.3.6.1.4.1.850.1.3.2.1.5 | OBJECT IDENTIFIER | read-only | This value is used in conjunction with tlpAlarmTableRef to define the object associated with this alarm condition. See the description of tlpAlarmTableRef for more information. |
| TIM tlpAlarmTime | 1.3.6.1.4.1.850.1.3.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tlpAlarmsTime shall equal 0. |
| INT tlpAlarmType | 1.3.6.1.4.1.850.1.3.2.1.7 | INTEGER | read-only | The category/group of this alarm. |
| tlpAlarmUserDefined | 1.3.6.1.4.1.850.1.3.3.2.2 | |||
| tlpAlarmUserDefined01 | 1.3.6.1.4.1.850.1.3.3.2.2.1 | User-defined event 1 is in alarm. | ||
| tlpAlarmUserDefined02 | 1.3.6.1.4.1.850.1.3.3.2.2.2 | User-defined event 2 is in alarm. | ||
| tlpAlarmUserDefined03 | 1.3.6.1.4.1.850.1.3.3.2.2.3 | User-defined event 3 is in alarm. | ||
| tlpAlarmUserDefined04 | 1.3.6.1.4.1.850.1.3.3.2.2.4 | User-defined event 4 is in alarm. | ||
| tlpAlarmUserDefined05 | 1.3.6.1.4.1.850.1.3.3.2.2.5 | User-defined event 5 is in alarm. | ||
| tlpAlarmUserDefined06 | 1.3.6.1.4.1.850.1.3.3.2.2.6 | User-defined event 6 is in alarm. | ||
| tlpAlarmUserDefined07 | 1.3.6.1.4.1.850.1.3.3.2.2.7 | User-defined event 7 is in alarm. | ||
| tlpAlarmUserDefined08 | 1.3.6.1.4.1.850.1.3.3.2.2.8 | User-defined event 8 is in alarm. | ||
| tlpAlarmUserDefined09 | 1.3.6.1.4.1.850.1.3.3.2.2.9 | User-defined event 9 is in alarm. | ||
| tlpAts | 1.3.6.1.4.1.850.1.1.3.4 | |||
| tlpAtsAlarmCircuitBreakerOpen | 1.3.6.1.4.1.850.1.3.3.6.9 | |||
| tlpAtsAlarmCircuitBreakerOpen01 | 1.3.6.1.4.1.850.1.3.3.6.9.1 | Circuit breaker 1 is open. | ||
| tlpAtsAlarmCircuitBreakerOpen02 | 1.3.6.1.4.1.850.1.3.3.6.9.2 | Circuit breaker 2 is open. | ||
| tlpAtsAlarmCircuitBreakerOpen03 | 1.3.6.1.4.1.850.1.3.3.6.9.3 | Circuit breaker 3 is open. | ||
| tlpAtsAlarmCircuitBreakerOpen04 | 1.3.6.1.4.1.850.1.3.3.6.9.4 | Circuit breaker 4 is open. | ||
| tlpAtsAlarmCircuitBreakerOpen05 | 1.3.6.1.4.1.850.1.3.3.6.9.5 | Circuit breaker 5 is open. | ||
| tlpAtsAlarmCircuitBreakerOpen06 | 1.3.6.1.4.1.850.1.3.3.6.9.6 | Circuit breaker 6 is open. | ||
| tlpAtsAlarmCurrentAboveThreshold | 1.3.6.1.4.1.850.1.3.3.6.10 | |||
| tlpAtsAlarmCurrentAboveThresholdA1 | 1.3.6.1.4.1.850.1.3.3.6.10.1 | The output current on input source 1 phase 1 exceeds load limits. | ||
| tlpAtsAlarmCurrentAboveThresholdA2 | 1.3.6.1.4.1.850.1.3.3.6.10.2 | The output current on input source 1 phase 2 exceeds load limits. | ||
| tlpAtsAlarmCurrentAboveThresholdA3 | 1.3.6.1.4.1.850.1.3.3.6.10.3 | The output current on input source 1 phase 3 exceeds load limits. | ||
| tlpAtsAlarmCurrentAboveThresholdB1 | 1.3.6.1.4.1.850.1.3.3.6.10.4 | The output current on input source 2 phase 1 exceeds load limits. | ||
| tlpAtsAlarmCurrentAboveThresholdB2 | 1.3.6.1.4.1.850.1.3.3.6.10.5 | The output current on input source 2 phase 2 exceeds load limits. | ||
| tlpAtsAlarmCurrentAboveThresholdB3 | 1.3.6.1.4.1.850.1.3.3.6.10.6 | The output current on input source 2 phase 3 exceeds load limits. | ||
| tlpAtsAlarmFrequency | 1.3.6.1.4.1.850.1.3.3.6.14 | |||
| tlpAtsAlarmGeneralFault | 1.3.6.1.4.1.850.1.3.3.6.12 | A general fault in the ats has been detected. | ||
| tlpAtsAlarmInputBad | 1.3.6.1.4.1.850.1.3.3.6.4 | An input condition is out of tolerance. | ||
| tlpAtsAlarmLoadLevelAboveThreshold | 1.3.6.1.4.1.850.1.3.3.6.3 | The load level is above the designated threshold. | ||
| tlpAtsAlarmLoadOff | 1.3.6.1.4.1.850.1.3.3.6.8 | |||
| tlpAtsAlarmLoadOff01 | 1.3.6.1.4.1.850.1.3.3.6.8.1 | Load 1 is off. | ||
| tlpAtsAlarmLoadOff02 | 1.3.6.1.4.1.850.1.3.3.6.8.2 | Load 2 is off. | ||
| tlpAtsAlarmLoadOff03 | 1.3.6.1.4.1.850.1.3.3.6.8.3 | Load 3 is off. | ||
| tlpAtsAlarmLoadOff04 | 1.3.6.1.4.1.850.1.3.3.6.8.4 | Load 4 is off. | ||
| tlpAtsAlarmLoadOff05 | 1.3.6.1.4.1.850.1.3.3.6.8.5 | Load 5 is off. | ||
| tlpAtsAlarmLoadOff06 | 1.3.6.1.4.1.850.1.3.3.6.8.6 | Load 6 is off. | ||
| tlpAtsAlarmLoadOff07 | 1.3.6.1.4.1.850.1.3.3.6.8.7 | Load 7 is off. | ||
| tlpAtsAlarmLoadOff08 | 1.3.6.1.4.1.850.1.3.3.6.8.8 | Load 8 is off. | ||
| tlpAtsAlarmLoadOff09 | 1.3.6.1.4.1.850.1.3.3.6.8.9 | Load 9 is off. | ||
| tlpAtsAlarmLoadOff10 | 1.3.6.1.4.1.850.1.3.3.6.8.10 | Load 10 is off. | ||
| tlpAtsAlarmLoadOff11 | 1.3.6.1.4.1.850.1.3.3.6.8.11 | Load 11 is off. | ||
| tlpAtsAlarmLoadOff12 | 1.3.6.1.4.1.850.1.3.3.6.8.12 | Load 12 is off. | ||
| tlpAtsAlarmLoadOff13 | 1.3.6.1.4.1.850.1.3.3.6.8.13 | Load 13 is off. | ||
| tlpAtsAlarmLoadOff14 | 1.3.6.1.4.1.850.1.3.3.6.8.14 | Load 14 is off. | ||
| tlpAtsAlarmLoadOff15 | 1.3.6.1.4.1.850.1.3.3.6.8.15 | Load 15 is off. | ||
| tlpAtsAlarmLoadOff16 | 1.3.6.1.4.1.850.1.3.3.6.8.16 | Load 16 is off. | ||
| tlpAtsAlarmLoadOff17 | 1.3.6.1.4.1.850.1.3.3.6.8.17 | Load 17 is off. | ||
| tlpAtsAlarmLoadOff18 | 1.3.6.1.4.1.850.1.3.3.6.8.18 | Load 18 is off. | ||
| tlpAtsAlarmLoadOff19 | 1.3.6.1.4.1.850.1.3.3.6.8.19 | Load 19 is off. | ||
| tlpAtsAlarmLoadOff20 | 1.3.6.1.4.1.850.1.3.3.6.8.20 | Load 20 is off. | ||
| tlpAtsAlarmLoadOff21 | 1.3.6.1.4.1.850.1.3.3.6.8.21 | Load 21 is off. | ||
| tlpAtsAlarmLoadOff22 | 1.3.6.1.4.1.850.1.3.3.6.8.22 | Load 22 is off. | ||
| tlpAtsAlarmLoadOff23 | 1.3.6.1.4.1.850.1.3.3.6.8.23 | Load 23 is off. | ||
| tlpAtsAlarmLoadOff24 | 1.3.6.1.4.1.850.1.3.3.6.8.24 | Load 24 is off. | ||
| tlpAtsAlarmLoadOff25 | 1.3.6.1.4.1.850.1.3.3.6.8.25 | Load 25 is off. | ||
| tlpAtsAlarmLoadOff26 | 1.3.6.1.4.1.850.1.3.3.6.8.26 | Load 26 is off. | ||
| tlpAtsAlarmLoadOff27 | 1.3.6.1.4.1.850.1.3.3.6.8.27 | Load 27 is off. | ||
| tlpAtsAlarmLoadOff28 | 1.3.6.1.4.1.850.1.3.3.6.8.28 | Load 28 is off. | ||
| tlpAtsAlarmLoadOff29 | 1.3.6.1.4.1.850.1.3.3.6.8.29 | Load 29 is off. | ||
| tlpAtsAlarmLoadOff30 | 1.3.6.1.4.1.850.1.3.3.6.8.30 | Load 30 is off. | ||
| tlpAtsAlarmLoadOff31 | 1.3.6.1.4.1.850.1.3.3.6.8.31 | Load 31 is off. | ||
| tlpAtsAlarmLoadOff32 | 1.3.6.1.4.1.850.1.3.3.6.8.32 | Load 32 is off. | ||
| tlpAtsAlarmLoadOff33 | 1.3.6.1.4.1.850.1.3.3.6.8.33 | Load 33 is off. | ||
| tlpAtsAlarmLoadOff34 | 1.3.6.1.4.1.850.1.3.3.6.8.34 | Load 34 is off. | ||
| tlpAtsAlarmLoadOff35 | 1.3.6.1.4.1.850.1.3.3.6.8.35 | Load 35 is off. | ||
| tlpAtsAlarmLoadOff36 | 1.3.6.1.4.1.850.1.3.3.6.8.36 | Load 36 is off. | ||
| tlpAtsAlarmLoadOff37 | 1.3.6.1.4.1.850.1.3.3.6.8.37 | Load 37 is off. | ||
| tlpAtsAlarmLoadOff38 | 1.3.6.1.4.1.850.1.3.3.6.8.38 | Load 38 is off. | ||
| tlpAtsAlarmLoadOff39 | 1.3.6.1.4.1.850.1.3.3.6.8.39 | Load 39 is off. | ||
| tlpAtsAlarmLoadOff40 | 1.3.6.1.4.1.850.1.3.3.6.8.40 | Load 40 is off. | ||
| tlpAtsAlarmLoadsNotAllOn | 1.3.6.1.4.1.850.1.3.3.6.11 | One of more loads are not on. | ||
| tlpAtsAlarmOutage | 1.3.6.1.4.1.850.1.3.3.6.1 | |||
| tlpAtsAlarmOutputBad | 1.3.6.1.4.1.850.1.3.3.6.5 | An output condition (other than OutputOverload) is out of tolerance. | ||
| tlpAtsAlarmOutputOff | 1.3.6.1.4.1.850.1.3.3.6.7 | The output of the ats is in the off state. | ||
| tlpAtsAlarmOutputOverload | 1.3.6.1.4.1.850.1.3.3.6.6 | The output load exceeds the ats output capacity. | ||
| tlpAtsAlarmOverVoltage | 1.3.6.1.4.1.850.1.3.3.6.13.1 | The input voltage is out of tolerance. | ||
| tlpAtsAlarms | 1.3.6.1.4.1.850.1.3.3.6 | |||
| tlpAtsAlarmSource1InvalidFrequency | 1.3.6.1.4.1.850.1.3.3.6.14.1 | The voltage on source 1 is out of tolerance. | ||
| tlpAtsAlarmSource1Outage | 1.3.6.1.4.1.850.1.3.3.6.1.1 | Input on source 1 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the primary source is not present. | ||
| tlpAtsAlarmSource1OverVoltage | 1.3.6.1.4.1.850.1.3.3.6.13.2 | The voltage on source 1 is out of tolerance. | ||
| tlpAtsAlarmSource1Temperature | 1.3.6.1.4.1.850.1.3.3.6.2.2 | The source 1 temperature is out of tolerance. | ||
| tlpAtsAlarmSource2InvalidFrequency | 1.3.6.1.4.1.850.1.3.3.6.14.2 | The voltage on source 2 is out of tolerance. | ||
| tlpAtsAlarmSource2Outage | 1.3.6.1.4.1.850.1.3.3.6.1.2 | Input on source 2 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the secondary source is not present. | ||
| tlpAtsAlarmSource2OverVoltage | 1.3.6.1.4.1.850.1.3.3.6.13.3 | The voltage on source 2 is out of tolerance. | ||
| tlpAtsAlarmSource2Temperature | 1.3.6.1.4.1.850.1.3.3.6.2.3 | The source 2 temperature is out of tolerance. | ||
| tlpAtsAlarmSystemTemperature | 1.3.6.1.4.1.850.1.3.3.6.2.1 | The system temperature is out of tolerance. | ||
| tlpAtsAlarmTemperature | 1.3.6.1.4.1.850.1.3.3.6.2 | |||
| tlpAtsAlarmVoltage | 1.3.6.1.4.1.850.1.3.3.6.13 | |||
| tlpAtsBreaker | 1.3.6.1.4.1.850.1.1.3.4.3.5 | |||
| tlpAtsBreakerEntry | 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1 | not-accessible | An entry containing information applicable to a particular bank breaker managed by this agent. | |
| U32 tlpAtsBreakerIndex | 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.1 | Unsigned32 | read-only | The table row index for the ats bank breaker. |
| INT tlpAtsBreakerStatus | 1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.2 | INTEGER | read-only | Indicates whether the bank breaker is open(0), closed(1) or not installed(2). |
| tlpAtsBreakerTable | 1.3.6.1.4.1.850.1.1.3.4.3.5.1 | not-accessible | A list of ats bank breaker table entries. The number of entries is given by the value of tlpAtsIdentNumBreakers. | |
| tlpAtsCircuit | 1.3.6.1.4.1.850.1.1.3.4.3.4 | |||
| I32 tlpAtsCircuitCurrentLimit | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.5 | Integer32 | read-only | The current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit. |
| I32 tlpAtsCircuitCurrentMax | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.7 | Integer32 | read-only | The maximum total current for all receptacles in a given circuit since last reset. |
| I32 tlpAtsCircuitCurrentMin | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.6 | Integer32 | read-only | The minimum total current for all receptacles in a given circuit since last reset. |
| tlpAtsCircuitEntry | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1 | not-accessible | An entry containing information applicable to a particular circuit managed by this agent. | |
| U32 tlpAtsCircuitIndex | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.1 | Unsigned32 | read-only | The table row index for the ats circuit. |
| I32 tlpAtsCircuitInputVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.3 | Integer32 | read-only | The input voltage for a circuit. |
| INT tlpAtsCircuitPhase | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.2 | INTEGER | read-only | Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0). |
| INT tlpAtsCircuitPowerFactor | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.9 | INTEGER | read-only | The power factor for all receptacles in a given circuit. |
| tlpAtsCircuitTable | 1.3.6.1.4.1.850.1.1.3.4.3.4.1 | not-accessible | A list of ats circuit table entries. The number of entries is given by the value of tlpAtsIdentNumCircuits. | |
| I32 tlpAtsCircuitTotalCurrent | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.4 | Integer32 | read-only | The total current for all receptacles in a given circuit. |
| I32 tlpAtsCircuitTotalPower | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.8 | Integer32 | read-only | The total power for all receptacles in a given circuit. |
| U32 tlpAtsCircuitUtilization | 1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.10 | Unsigned32 | read-only | The percentage of utilization of a given circuit. This is typically a calculation of tlpAtsCircuitTotalCurrent / tlpAtsCircuitCurrentLimit. |
| tlpAtsConfig | 1.3.6.1.4.1.850.1.1.3.4.5 | |||
| INT tlpAtsConfigAutoRampOnTransition | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.5 | INTEGER | read-write | When enabled(1), the ats should perform its preconfigured ramp sequence when the input source transfers from its designated secondary source to its designated primary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpAtsConfigAutoShedOnTransition | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.6 | INTEGER | read-write | When enabled(1), the ats should perform its preconfigured shed sequence when the input source transfers from its designated primary source to its designated secondary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME. |
| tlpAtsConfigEntry | 1.3.6.1.4.1.850.1.1.3.4.5.1.1 | not-accessible | An entry containing configuration options for a particular ats. | |
| U32 tlpAtsConfigHighVoltageReset | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.2 | Unsigned32 | read-write | If a unit is disconnected due to over-voltage, the line voltage has to fall below this value before the unit re-connects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransfer. The minimum value allowed is dictated by the greater of tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigHighVoltageTransfer | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.1 | Unsigned32 | read-write | The maximum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageReset. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigInputVoltage | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.1 | Unsigned32 | read-write | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. |
| U32 tlpAtsConfigLowVoltageReset | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.9 | Unsigned32 | read-write | If a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. The maximum value allowed is dictated by the lesser value of tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransfer. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigLowVoltageTransfer | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.10 | Unsigned32 | read-write | The minimum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigLowVoltageReset. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigOverCurrentThreshold | 1.3.6.1.4.1.850.1.1.3.4.5.4.1.1 | Unsigned32 | read-write | The output current measurement at which an over current condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigOverLoadThreshold | 1.3.6.1.4.1.850.1.1.3.4.5.4.1.4 | Unsigned32 | read-write | The system load at which an overload condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigOverTemperatureThreshold | 1.3.6.1.4.1.850.1.1.3.4.5.4.1.2 | Unsigned32 | read-write | The system temperature at which an over temperature condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigOverVoltageThreshold | 1.3.6.1.4.1.850.1.1.3.4.5.4.1.3 | Unsigned32 | read-write | The input voltage measurement at which an over voltage condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource1BrownoutSet | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.4 | Unsigned32 | read-write | This value dictates the voltage level below which source 1 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource1TransferReset. The minimum value allowed is dictated by tlpAtsConfigSource1TransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource1ReturnTime | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.3 | Unsigned32 | read-write | The nominal time to delay a transition to Source 1, if it is the preferred source. |
| U32 tlpAtsConfigSource1TransferReset | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.3 | Unsigned32 | read-write | If input source 1 voltage level is above this value, a unit connected to source 2 will transition to source 1 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource1TransferSet | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.5 | Unsigned32 | read-write | If input source 1 voltage level falls below this value, a unit connected to source 1 will transition to source 2 (if it is in fair condition as denoted by tlpAtsConfigSource2TransferSet). The maximum value allowed is dictated by tlpAtsConfigSource1BrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource2BrownoutSet | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.7 | Unsigned32 | read-write | This value dictates the voltage level below which source 2 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource2TransferReset. The minimum value allowed is dictated by tlpAtsConfigSource2TransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource2ReturnTime | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.4 | Unsigned32 | read-write | The nominal time to delay a transition to Source 2, if it is the preferred source. |
| U32 tlpAtsConfigSource2TransferReset | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.6 | Unsigned32 | read-write | If input source 2 voltage level is above this value, a unit connected to source 1 will transition to source 2 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigSource2BrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSource2TransferSet | 1.3.6.1.4.1.850.1.1.3.4.5.2.1.8 | Unsigned32 | read-write | If input source 2 voltage level falls below this value, a unit connected to source 2 will transition to source 1 (if it is in fair condition as denoted by tlpAtsConfigSource1TransferSet). The maximum value allowed is dictated by tlpAtsConfigSource2BrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSourceBrownoutSetMaximum | 1.3.6.1.4.1.850.1.1.3.4.5.3.1.2 | Unsigned32 | read-write | This value dictates the absolute upper limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset, respectively, are also used when determining the greatest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSourceBrownoutSetMinimum | 1.3.6.1.4.1.850.1.1.3.4.5.3.1.1 | Unsigned32 | read-write | This value dictates the absolute lower limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet, respectively, are also used when determining the lowest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| INT tlpAtsConfigSourceSelect | 1.3.6.1.4.1.850.1.1.3.4.5.1.1.2 | INTEGER | read-write | The determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(1) for devices with a single input source. Setting this value is supported only on selected models. |
| U32 tlpAtsConfigSourceTransferSetMaximum | 1.3.6.1.4.1.850.1.1.3.4.5.3.1.4 | Unsigned32 | read-write | This value dictates the absolute upper limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet, respectively, are also used when determining the greatest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsConfigSourceTransferSetMinimum | 1.3.6.1.4.1.850.1.1.3.4.5.3.1.3 | Unsigned32 | read-write | This value dictates the absolute lower limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigLowVoltageReset is also used when determining the lowest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| tlpAtsConfigTable | 1.3.6.1.4.1.850.1.1.3.4.5.1 | not-accessible | The configuration options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss. | |
| tlpAtsConfigThresholdEntry | 1.3.6.1.4.1.850.1.1.3.4.5.4.1 | not-accessible | An entry containing configurable threshold options for a particular ats. | |
| tlpAtsConfigThresholdTable | 1.3.6.1.4.1.850.1.1.3.4.5.4 | not-accessible | The configurable threshold options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss. | |
| tlpAtsConfigVoltageRangeEntry | 1.3.6.1.4.1.850.1.1.3.4.5.2.1 | not-accessible | An entry containing voltage range configuration options for a particular ats. | |
| tlpAtsConfigVoltageRangeLimitsEntry | 1.3.6.1.4.1.850.1.1.3.4.5.3.1 | not-accessible | An entry containing voltage range limits configuration options for a particular ats. | |
| tlpAtsConfigVoltageRangeLimitsTable | 1.3.6.1.4.1.850.1.1.3.4.5.3 | not-accessible | The voltage range table, as documented by tlpAtsConfigVoltageRangeTable requires that all changes adhere with stack order, from high transfer voltage down to low transfer voltage. In addition to stack order, certain voltage range values have limits defining the absolute minimum and absolute maximum for such values. Any voltage value violating any respective limit defined herein will be rejected. | |
| tlpAtsConfigVoltageRangeTable | 1.3.6.1.4.1.850.1.1.3.4.5.2 | not-accessible | The voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satsify the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exlusive unless indicated otherwise. | |
| tlpAtsControl | 1.3.6.1.4.1.850.1.1.3.4.4 | |||
| T/F tlpAtsControlAtsOff | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.4 | TruthValue | read-write | Set to TRUE to turn the ats off. |
| T/F tlpAtsControlAtsOn | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.3 | TruthValue | read-write | Set to TRUE to turn the ats on. |
| T/F tlpAtsControlAtsReboot | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.5 | TruthValue | read-write | Set to TRUE to reboot the ats. |
| tlpAtsControlEntry | 1.3.6.1.4.1.850.1.1.3.4.4.1.1 | not-accessible | An entry containing controls for a particular ats. | |
| T/F tlpAtsControlRamp | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.1 | TruthValue | read-write | Set to TRUE to initiate the pre-designated ramp sequence on the ats. |
| T/F tlpAtsControlResetGeneralFault | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.6 | TruthValue | read-write | Set to TRUE to reset the general fault alarm indicated by tlpAtsDeviceGeneralFault. |
| T/F tlpAtsControlShed | 1.3.6.1.4.1.850.1.1.3.4.4.1.1.2 | TruthValue | read-write | Set to TRUE to initiate the pre-designated shed sequence on the ats. |
| tlpAtsControlTable | 1.3.6.1.4.1.850.1.1.3.4.4.1 | not-accessible | The actionable controls for each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. | |
| tlpAtsDetail | 1.3.6.1.4.1.850.1.1.3.4.3 | |||
| tlpAtsDevice | 1.3.6.1.4.1.850.1.1.3.4.2 | |||
| U32 tlpAtsDeviceAggregatePowerFactor | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.10 | Unsigned32 | read-only | The aggregrate power factor of all phases. |
| tlpAtsDeviceEntry | 1.3.6.1.4.1.850.1.1.3.4.2.1.1 | not-accessible | An entry containing device details for a particular ats. | |
| T/F tlpAtsDeviceGeneralFault | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.12 | TruthValue | read-only | Indicates whether or not the ats is in a system fault condition. When the ats is in such a fault condition, the condition can be cleared with tlpAtsControlResetGeneralFault. |
| INT tlpAtsDeviceMainLoadCommand | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.3 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on. |
| T/F tlpAtsDeviceMainLoadControllable | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.2 | TruthValue | read-only | Indicates whether or not the main output is controllable, and whether the ups can be turned off and on. |
| INT tlpAtsDeviceMainLoadState | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.1 | INTEGER | read-only | The current state of the main output of the device. |
| INT tlpAtsDeviceOutputCurrentPrecision | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.11 | INTEGER | read-only | Output current is reported by tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpAtsOutputCurrent reports 530 and tlpAtsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3. |
| U32 tlpAtsDeviceOutputPowerTotal | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.9 | Unsigned32 | read-only | The AC output total power for all circuits. |
| INT tlpAtsDevicePhaseImbalance | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.8 | INTEGER | read-only | The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%. |
| I32 tlpAtsDevicePowerOnDelay | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.4 | Integer32 | read-write | The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source. |
| tlpAtsDeviceTable | 1.3.6.1.4.1.850.1.1.3.4.2.1 | not-accessible | The device details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. | |
| I32 tlpAtsDeviceTemperatureC | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.6 | Integer32 | read-only | The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpAtsDeviceTemperatureF | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.7 | Integer32 | read-only | The ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpAtsDeviceTotalInputPowerRating | 1.3.6.1.4.1.850.1.1.3.4.2.1.1.5 | Integer32 | read-only | The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpAtsDisplayAutoScroll | 1.3.6.1.4.1.850.1.1.3.4.1.4.1.3 | INTEGER | read-write | Indicates whether the LED display automatically scrolls through displaying status values. |
| tlpAtsDisplayEntry | 1.3.6.1.4.1.850.1.1.3.4.1.4.1 | not-accessible | An entry containing display details for a particular ats. | |
| INT tlpAtsDisplayIntensity | 1.3.6.1.4.1.850.1.1.3.4.1.4.1.4 | INTEGER | read-write | Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted. |
| INT tlpAtsDisplayOrientation | 1.3.6.1.4.1.850.1.1.3.4.1.4.1.2 | INTEGER | read-write | Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0). |
| INT tlpAtsDisplayScheme | 1.3.6.1.4.1.850.1.1.3.4.1.4.1.1 | INTEGER | read-write | Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1). |
| tlpAtsDisplayTable | 1.3.6.1.4.1.850.1.1.3.4.1.4 | not-accessible | The display details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. | |
| INT tlpAtsDisplayUnits | 1.3.6.1.4.1.850.1.1.3.4.1.4.1.5 | INTEGER | read-write | Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Farenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius. |
| tlpAtsHeatsink | 1.3.6.1.4.1.850.1.1.3.4.3.6 | |||
| tlpAtsHeatsinkEntry | 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1 | not-accessible | An entry containing information applicable to a particular heatsink thermistor managed by this agent. | |
| U32 tlpAtsHeatsinkIndex | 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.1 | Unsigned32 | read-only | The table row index for the ats heatsink thermistor. |
| INT tlpAtsHeatsinkStatus | 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.2 | INTEGER | read-only | Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected. |
| tlpAtsHeatsinkTable | 1.3.6.1.4.1.850.1.1.3.4.3.6.1 | not-accessible | A list of ats heatsink thermistor table entries. The number of entries is given by the value of tlpAtsIdentNumHeatsinks. | |
| I32 tlpAtsHeatsinkTemperatureC | 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.3 | Integer32 | read-only | The temperature at the heatsink termistor in tenths degrees Centigrade. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpAtsHeatsinkTemperatureF | 1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.4 | Integer32 | read-only | The temperature at the heatsink termistor in tenths degrees Farenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| tlpAtsIdent | 1.3.6.1.4.1.850.1.1.3.4.1 | |||
| tlpAtsIdentEntry | 1.3.6.1.4.1.850.1.1.3.4.1.2.1 | not-accessible | An entry containing details for a particular ats. | |
| U32 tlpAtsIdentNumAts | 1.3.6.1.4.1.850.1.1.3.4.1.1 | Unsigned32 | read-only | The number of ats devices that this agent is currently managing. |
| U32 tlpAtsIdentNumBreakers | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.7 | Unsigned32 | read-only | The number of bank breakers supported by the ats. |
| U32 tlpAtsIdentNumCircuits | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.6 | Unsigned32 | read-only | The number of circuits supported by the ats. |
| U32 tlpAtsIdentNumHeatsinks | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.8 | Unsigned32 | read-only | The number of heatsink thermistors supported by the ats. |
| U32 tlpAtsIdentNumInputs | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.1 | Unsigned32 | read-only | The number of inputs supported by the ats. |
| U32 tlpAtsIdentNumOutletGroups | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.5 | Unsigned32 | read-only | The number of receptacle groups supported by the ats. |
| U32 tlpAtsIdentNumOutlets | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.4 | Unsigned32 | read-only | The number of receptacles supported by the ats. |
| U32 tlpAtsIdentNumOutputs | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.2 | Unsigned32 | read-only | The number of outputs supported by the ats. |
| U32 tlpAtsIdentNumPhases | 1.3.6.1.4.1.850.1.1.3.4.1.2.1.3 | Unsigned32 | read-only | The number of phases per input supported by the ats. |
| tlpAtsIdentTable | 1.3.6.1.4.1.850.1.1.3.4.1.2 | not-accessible | The identity details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. | |
| tlpAtsInput | 1.3.6.1.4.1.850.1.1.3.4.3.1 | |||
| U32 tlpAtsInputBadTransferVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.4 | Unsigned32 | read-only | The minimum line voltage allowed before the unit disconnects the AC input connection. |
| U32 tlpAtsInputBadTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.5 | Unsigned32 | read-only | The lower boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpAtsInputBadTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.6 | Unsigned32 | read-only | The upper boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpAtsInputBadVoltageThreshold | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.11 | Unsigned32 | read-only | The minimum line voltage allowed before the device disconnects the AC input connection. |
| U32 tlpAtsInputCurrentLimit | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.15 | Unsigned32 | read-only | The capacity of each phase conductor in the ats limited by the AC input cord or any other potential limiting factors unique to a given unit. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| tlpAtsInputEntry | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1 | not-accessible | An entry containing information applicable to a particular primary input phase managed by this agent. | |
| U32 tlpAtsInputFairVoltageThreshold | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.10 | Unsigned32 | read-only | The voltage level at which the device will transition between sources. |
| U32 tlpAtsInputHighTransferVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.7 | Unsigned32 | read-only | The maximum line voltage allowed before the unit disconnects the AC input connection. |
| U32 tlpAtsInputHighTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.8 | Unsigned32 | read-only | The lower boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpAtsInputHighTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.9 | Unsigned32 | read-only | The upper boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpAtsInputLineIndex | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.1 | Unsigned32 | read-only | The table row index for the input line on the ats. |
| U32 tlpAtsInputNominalVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.1 | Unsigned32 | read-only | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsInputNominalVoltagePhaseToNeutral | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.3 | Unsigned32 | read-only | The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero. |
| U32 tlpAtsInputNominalVoltagePhaseToPhase | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.2 | Unsigned32 | read-only | The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero. |
| U32 tlpAtsInputPhaseCurrent | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.8 | Unsigned32 | read-only | The magnitude of the present input current for a given phase. |
| tlpAtsInputPhaseEntry | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1 | not-accessible | An entry containing information applicable to a particular primary input phase managed by this agent. | |
| U32 tlpAtsInputPhaseFrequency | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.4 | Unsigned32 | read-only | The present input frequency for a given phase. |
| U32 tlpAtsInputPhaseIndex | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.2 | Unsigned32 | read-only | The table row index for the input phase for the input line. |
| tlpAtsInputPhaseTable | 1.3.6.1.4.1.850.1.1.3.4.3.1.2 | not-accessible | The input phase details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumInputs and tlpAtsIdentNumPhases per each device. | |
| INT tlpAtsInputPhaseType | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.3 | INTEGER | read-only | Denotes whether measurements are phase to neutral(0) or phase to phase(1). |
| U32 tlpAtsInputPhaseVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5 | Unsigned32 | read-only | The magnitude of the present input voltage for a given phase. |
| U32 tlpAtsInputPhaseVoltageMax | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.7 | Unsigned32 | read-write | The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| U32 tlpAtsInputPhaseVoltageMin | 1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.6 | Unsigned32 | read-write | The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| INT tlpAtsInputSourceAvailability | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.12 | INTEGER | read-only | The determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available. |
| INT tlpAtsInputSourceInUse | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.13 | INTEGER | read-only | The determination as to which one of two AC input lines is in use. Not all devices support the reporting of which source is currently in use. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpAtsInputSourceTransitionCount | 1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.14 | Unsigned32 | read-only | The number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| tlpAtsInputTable | 1.3.6.1.4.1.850.1.1.3.4.3.1.1 | not-accessible | The input details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of atss managed by the agent as reported by tlpAtsIdentNumAts. | |
| tlpAtsOutlet | 1.3.6.1.4.1.850.1.1.3.4.3.3 | |||
| I32 tlpAtsOutletBank | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.15 | Integer32 | read-only | Indicates on which bank the given outlet is located. |
| I32 tlpAtsOutletCircuit | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.16 | Integer32 | read-only | Indicates on which circuit the given outlet is wired. |
| INT tlpAtsOutletCommand | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on. |
| T/F tlpAtsOutletControllable | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.5 | TruthValue | read-only | Denotes whether this outlet is controllable. |
| U32 tlpAtsOutletCurrent | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.8 | Unsigned32 | read-only | The present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpAtsSupportsCurrentPower. |
| STR tlpAtsOutletDescription | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.3 | DisplayString | read-write | A user-definable string identifying the device(s) connected to the given outlet. |
| tlpAtsOutletEntry | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1 | not-accessible | An entry containing information applicable to a particular outlet managed by this agent. | |
| I32 tlpAtsOutletGroup | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.14 | Integer32 | read-write | The tlpAtsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped. |
| INT tlpAtsOutletGroupCommand | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on. |
| STR tlpAtsOutletGroupDescription | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.4 | DisplayString | read-write | A description for this outlet group. |
| tlpAtsOutletGroupEntry | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1 | not-accessible | An entry containing information applicable to a particular outlet group managed by this agent. | |
| U32 tlpAtsOutletGroupIndex | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.1 | Unsigned32 | read-only | The table row index for the ats outlet group. |
| STR tlpAtsOutletGroupName | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.3 | DisplayString | read-write | The name of this outlet group. |
| ROW tlpAtsOutletGroupRowStatus | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.2 | RowStatus | read-write | Row status for the tlpAtsOutletGroupTable |
| INT tlpAtsOutletGroupState | 1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.5 | INTEGER | read-only | The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined. |
| tlpAtsOutletGroupTable | 1.3.6.1.4.1.850.1.1.3.4.3.3.2 | not-accessible | The receptacle grouping details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutletGroups per each device. | |
| U32 tlpAtsOutletIndex | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.1 | Unsigned32 | read-only | The table row index for the ats outlet. |
| STR tlpAtsOutletName | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.2 | DisplayString | read-write | A user-definable string identifying the name of the outlet. |
| INT tlpAtsOutletPhase | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.17 | INTEGER | read-only | Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0). |
| U32 tlpAtsOutletPower | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.9 | Unsigned32 | read-only | The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpAtsSupportsCurrentPower. |
| INT tlpAtsOutletRampAction | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.10 | INTEGER | read-write | The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpAtsOutletRampDelay | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.11 | Integer32 | read-write | The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpAtsOutletShedAction | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.12 | INTEGER | read-write | The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpAtsOutletShedDelay | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.13 | Integer32 | read-write | The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpAtsOutletState | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.4 | INTEGER | read-only | The current state of the outlet. |
| tlpAtsOutletTable | 1.3.6.1.4.1.850.1.1.3.4.3.3.1 | not-accessible | The receptacle status details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutlets per each device. | |
| U32 tlpAtsOutletVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.7 | Unsigned32 | read-only | The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpAtsSupportsOutletVoltage. |
| tlpAtsOutput | 1.3.6.1.4.1.850.1.1.3.4.3.2 | |||
| U32 tlpAtsOutputActivePower | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.8 | Unsigned32 | read-only | The output power for a given phase. |
| U32 tlpAtsOutputCurrent | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5 | Unsigned32 | read-only | The output current, in hundreths of amps, for a given phase. |
| U32 tlpAtsOutputCurrentMax | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.7 | Unsigned32 | read-only | The maximum current observed for a given phase since last reset. |
| U32 tlpAtsOutputCurrentMin | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.6 | Unsigned32 | read-only | The minimum current observed for a given phase since last reset. |
| tlpAtsOutputEntry | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1 | not-accessible | An entry containing output information applicable to a particular phase managed by this agent. | |
| U32 tlpAtsOutputIndex | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.1 | Unsigned32 | read-only | The table row index for the ats phase. |
| INT tlpAtsOutputPhase | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.2 | INTEGER | read-only | Indicates the phase associated with the output line. |
| INT tlpAtsOutputPhaseType | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.3 | INTEGER | read-only | Denotes whether measurements are phase to neutral(0) or phase to phase(1). |
| U32 tlpAtsOutputPowerFactor | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.9 | Unsigned32 | read-only | The output power factor, in hundreths of a percent, for a given phase. |
| INT tlpAtsOutputSource | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.10 | INTEGER | read-only | The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker. |
| tlpAtsOutputTable | 1.3.6.1.4.1.850.1.1.3.4.3.2.1 | not-accessible | The output details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutputs per each device. | |
| U32 tlpAtsOutputVoltage | 1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.4 | Unsigned32 | read-only | The magnitude of the present output voltage for a given output line. |
| T/F tlpAtsSupportsEnergywise | 1.3.6.1.4.1.850.1.1.3.4.1.3.1.1 | TruthValue | read-only | Indicates whether the ats supports Cisco EnergyWise. |
| tlpAtsSupportsEntry | 1.3.6.1.4.1.850.1.1.3.4.1.3.1 | not-accessible | An entry containing supported details for a particular ats. | |
| T/F tlpAtsSupportsOutletCurrentPower | 1.3.6.1.4.1.850.1.1.3.4.1.3.1.4 | TruthValue | read-only | Indicates whether the ats reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletCurrent and tlpAtsOutletPower. |
| T/F tlpAtsSupportsOutletGroup | 1.3.6.1.4.1.850.1.1.3.4.1.3.1.3 | TruthValue | read-only | Indicates whether the ats supports outlet groups. |
| T/F tlpAtsSupportsOutletVoltage | 1.3.6.1.4.1.850.1.1.3.4.1.3.1.5 | TruthValue | read-only | Indicates whether the ats reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletVoltage. |
| T/F tlpAtsSupportsRampShed | 1.3.6.1.4.1.850.1.1.3.4.1.3.1.2 | TruthValue | read-only | Indicates whether the ats supports ramping and shedding. |
| tlpAtsSupportsTable | 1.3.6.1.4.1.850.1.1.3.4.1.3 | not-accessible | The supported details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. | |
| tlpCooling | 1.3.6.1.4.1.850.1.1.3.5 | |||
| tlpCoolingAlarmAirFilterClogged | 1.3.6.1.4.1.850.1.3.3.7.7 | The air filter is clogged. | ||
| tlpCoolingAlarmAirFilterRunHoursViolation | 1.3.6.1.4.1.850.1.3.3.7.8 | The air filter run hours was violated. | ||
| tlpCoolingAlarmAutoCoolingOn | 1.3.6.1.4.1.850.1.3.3.7.35 | Automatic cooling was activated to lower the temperature below the remote set point. | ||
| tlpCoolingAlarmCompressorFailure | 1.3.6.1.4.1.850.1.3.3.7.28 | The compressor has failed. | ||
| tlpCoolingAlarmCondensatePumpFault | 1.3.6.1.4.1.850.1.3.3.7.12 | The condensate pump is in fault. | ||
| tlpCoolingAlarmCondenserFailure | 1.3.6.1.4.1.850.1.3.3.7.15 | The condenser has failed. | ||
| tlpCoolingAlarmCondenserFanFault | 1.3.6.1.4.1.850.1.3.3.7.14 | The condenser fan is in fault. | ||
| tlpCoolingAlarmCondenserInletAirSensorFault | 1.3.6.1.4.1.850.1.3.3.7.3 | The condenser inlet air sensor is in fault. | ||
| tlpCoolingAlarmCondenserOutletAirSensorFault | 1.3.6.1.4.1.850.1.3.3.7.4 | The condenser outlet air sensor is in fault. | ||
| tlpCoolingAlarmCurrentLimit | 1.3.6.1.4.1.850.1.3.3.7.29 | The current is out of range. | ||
| tlpCoolingAlarmDischargePressureHigh | 1.3.6.1.4.1.850.1.3.3.7.21 | The discharge pressure is high. | ||
| tlpCoolingAlarmDischargePressurePersistentHigh | 1.3.6.1.4.1.850.1.3.3.7.23 | The discharge pressure is persistently high. | ||
| tlpCoolingAlarmDischargePressureSensorFault | 1.3.6.1.4.1.850.1.3.3.7.33 | The discharge pressure sensor is in fault. | ||
| tlpCoolingAlarmDisconnectedFromDevice | 1.3.6.1.4.1.850.1.3.3.7.37 | The device communications is disconnected. | ||
| tlpCoolingAlarmEvaporatorCoolingFailure | 1.3.6.1.4.1.850.1.3.3.7.16 | The evaporator cooling is in fault. | ||
| tlpCoolingAlarmEvaporatorFailure | 1.3.6.1.4.1.850.1.3.3.7.19 | The evaporator has failed. | ||
| tlpCoolingAlarmEvaporatorFreezeUp | 1.3.6.1.4.1.850.1.3.3.7.20 | The evaporator is frozen. | ||
| tlpCoolingAlarmEvaporatorTemperatureSensorFault | 1.3.6.1.4.1.850.1.3.3.7.6 | The evaporator temperature sensor is in fault. | ||
| tlpCoolingAlarmFanOverCurrent | 1.3.6.1.4.1.850.1.3.3.7.32 | The fan is over current. | ||
| tlpCoolingAlarmFanUnderCurrent | 1.3.6.1.4.1.850.1.3.3.7.31 | The fan is under current. | ||
| tlpCoolingAlarmInverterCommunicationsFault | 1.3.6.1.4.1.850.1.3.3.7.10 | The inverter communications is in fault. | ||
| tlpCoolingAlarmLowRefrigerantStartupFault | 1.3.6.1.4.1.850.1.3.3.7.13 | The low refrigerant startup is in fault. | ||
| tlpCoolingAlarmPowerButtonPressed | 1.3.6.1.4.1.850.1.3.3.7.36 | Power button was pressed on the front panel. | ||
| tlpCoolingAlarmPressureGaugeFailure | 1.3.6.1.4.1.850.1.3.3.7.22 | The pressure gauge has failed. | ||
| tlpCoolingAlarmRemoteShutdownViaInputContact | 1.3.6.1.4.1.850.1.3.3.7.11 | A remote shutdown was triggerd by an input contact. | ||
| tlpCoolingAlarmReturnAirSensorFault | 1.3.6.1.4.1.850.1.3.3.7.2 | The return air sensor is in fault. | ||
| tlpCoolingAlarmReturnAirTempHigh | 1.3.6.1.4.1.850.1.3.3.7.17 | The return air temperature is high. | ||
| tlpCoolingAlarms | 1.3.6.1.4.1.850.1.3.3.7 | |||
| tlpCoolingAlarmStartupLinePressureImbalance | 1.3.6.1.4.1.850.1.3.3.7.27 | The startup line pressure is in imbalance. | ||
| tlpCoolingAlarmSuctionPressureLow | 1.3.6.1.4.1.850.1.3.3.7.25 | The suction pressure is low. | ||
| tlpCoolingAlarmSuctionPressureLowStartFailure | 1.3.6.1.4.1.850.1.3.3.7.24 | Cannot start due to low suction pressure. | ||
| tlpCoolingAlarmSuctionPressurePersistentLow | 1.3.6.1.4.1.850.1.3.3.7.26 | The suction pressure is persistently low. | ||
| tlpCoolingAlarmSuctionPressureSensorFault | 1.3.6.1.4.1.850.1.3.3.7.9 | The suction pressure sensor is in fault. | ||
| tlpCoolingAlarmSuctionTemperatureSensorFault | 1.3.6.1.4.1.850.1.3.3.7.5 | The suction temperature sensor is in fault. | ||
| tlpCoolingAlarmSupplyAirSensorFault | 1.3.6.1.4.1.850.1.3.3.7.1 | The supply air sensor is in fault. | ||
| tlpCoolingAlarmSupplyAirTempHigh | 1.3.6.1.4.1.850.1.3.3.7.18 | The supply air temperature is high. | ||
| tlpCoolingAlarmWaterFull | 1.3.6.1.4.1.850.1.3.3.7.34 | Water is Full. | ||
| tlpCoolingAlarmWaterLeak | 1.3.6.1.4.1.850.1.3.3.7.30 | Water is leaking. | ||
| tlpCoolingConfig | 1.3.6.1.4.1.850.1.1.3.5.5 | |||
| tlpCoolingControl | 1.3.6.1.4.1.850.1.1.3.5.4 | |||
| tlpCoolingDetail | 1.3.6.1.4.1.850.1.1.3.5.3 | |||
| tlpCoolingDevice | 1.3.6.1.4.1.850.1.1.3.5.2 | |||
| tlpCoolingIdent | 1.3.6.1.4.1.850.1.1.3.5.1 | |||
| U32 tlpCoolingIdentNumCooling | 1.3.6.1.4.1.850.1.1.3.5.1.1 | Unsigned32 | read-only | The number of cooling devices that this agent is currently managing. |
| tlpCoolingInput | 1.3.6.1.4.1.850.1.1.3.5.3.1 | |||
| tlpCoolingOutput | 1.3.6.1.4.1.850.1.1.3.5.3.2 | |||
| tlpDevice | 1.3.6.1.4.1.850.1.1.1 | |||
| tlpDeviceAlarms | 1.3.6.1.4.1.850.1.3.3.2 | |||
| tlpDeviceDetail | 1.3.6.1.4.1.850.1.1.2 | |||
| tlpDeviceEntry | 1.3.6.1.4.1.850.1.1.1.2.1 | not-accessible | An entry containing information applicable to a particular device managed by this agent. | |
| INT tlpDeviceID | 1.3.6.1.4.1.850.1.1.1.2.1.7 | INTEGER | read-write | A user-supplied ID for the device. |
| STR tlpDeviceIdentCommPortName | 1.3.6.1.4.1.850.1.1.2.1.1.3 | DisplayString | read-only | The name of the communications port. |
| INT tlpDeviceIdentCommPortType | 1.3.6.1.4.1.850.1.1.2.1.1.2 | INTEGER | read-only | The type of communications port used to connect with the device. |
| STR tlpDeviceIdentCurrentUptime | 1.3.6.1.4.1.850.1.1.2.1.1.8 | DisplayString | read-only | The device uptime since its last startup. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device. |
| STR tlpDeviceIdentDateInstalled | 1.3.6.1.4.1.850.1.1.2.1.1.6 | DisplayString | read-write | The installation date for this device in the format of mm/dd/yyyy. |
| tlpDeviceIdentEntry | 1.3.6.1.4.1.850.1.1.2.1.1 | not-accessible | An entry containing details for a particular device. | |
| STR tlpDeviceIdentFirmwareVersion | 1.3.6.1.4.1.850.1.1.2.1.1.4 | DisplayString | read-only | The firmware version of the device. |
| STR tlpDeviceIdentHardwareVersion | 1.3.6.1.4.1.850.1.1.2.1.1.7 | DisplayString | read-only | The hardware revision of the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device. |
| STR tlpDeviceIdentProtocol | 1.3.6.1.4.1.850.1.1.2.1.1.1 | DisplayString | read-only | The Tripplite protocol used to communicate with the device. |
| STR tlpDeviceIdentSerialNum | 1.3.6.1.4.1.850.1.1.2.1.1.5 | DisplayString | read-only | The serial number of the device. |
| tlpDeviceIdentTable | 1.3.6.1.4.1.850.1.1.2.1 | not-accessible | The identity details of each device in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| STR tlpDeviceIdentTotalUptime | 1.3.6.1.4.1.850.1.1.2.1.1.9 | DisplayString | read-only | The cumulative (total) uptime for the device. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device. |
| U32 tlpDeviceIndex | 1.3.6.1.4.1.850.1.1.1.2.1.1 | Unsigned32 | read-only | The table row index for the device. |
| STR tlpDeviceLocation | 1.3.6.1.4.1.850.1.1.1.2.1.8 | DisplayString | read-write | A user-supplied location for the device. |
| STR tlpDeviceManufacturer | 1.3.6.1.4.1.850.1.1.1.2.1.4 | DisplayString | read-only | The name of the manufacturer. |
| STR tlpDeviceModel | 1.3.6.1.4.1.850.1.1.1.2.1.5 | DisplayString | read-only | The model designation. |
| STR tlpDeviceName | 1.3.6.1.4.1.850.1.1.1.2.1.6 | DisplayString | read-write | A user-supplied name for the device. |
| U32 tlpDeviceNumDevices | 1.3.6.1.4.1.850.1.1.1.1 | Unsigned32 | read-only | The number of devices that this agent is currently managing. |
| STR tlpDeviceRegion | 1.3.6.1.4.1.850.1.1.1.2.1.9 | DisplayString | read-write | A user-supplied region for the device. |
| ROW tlpDeviceRowStatus | 1.3.6.1.4.1.850.1.1.1.2.1.2 | RowStatus | read-only | Used with table edits to indicate the status of a given row in tlDeviceTable. |
| INT tlpDeviceStatus | 1.3.6.1.4.1.850.1.1.1.2.1.10 | INTEGER | read-only | The currently most critical alarm status for the device. |
| tlpDeviceTable | 1.3.6.1.4.1.850.1.1.1.2 | not-accessible | A list of device table entries. The number of entries is given by the value of tlpDevicesNumDevices. | |
| OID tlpDeviceType | 1.3.6.1.4.1.850.1.1.1.2.1.3 | OBJECT IDENTIFIER | read-only | The type of device. One of the appropriate hardware types: ups, pdu, envirosense, etc. |
| tlpDeviceTypes | 1.3.6.1.4.1.850.1.1.3 | |||
| tlpEnvAlarmHumidityBeyondLimits | 1.3.6.1.4.1.850.1.3.3.5.2 | The humidity exceeds limits. | ||
| tlpEnvAlarmInputContact | 1.3.6.1.4.1.850.1.3.3.5.3 | |||
| tlpEnvAlarmInputContact01 | 1.3.6.1.4.1.850.1.3.3.5.3.1 | Input contact 1 is in alarm. | ||
| tlpEnvAlarmInputContact02 | 1.3.6.1.4.1.850.1.3.3.5.3.2 | Input contact 2 is in alarm. | ||
| tlpEnvAlarmInputContact03 | 1.3.6.1.4.1.850.1.3.3.5.3.3 | Input contact 3 is in alarm. | ||
| tlpEnvAlarmInputContact04 | 1.3.6.1.4.1.850.1.3.3.5.3.4 | Input contact 4 is in alarm. | ||
| tlpEnvAlarmOutputContact | 1.3.6.1.4.1.850.1.3.3.5.4 | |||
| tlpEnvAlarmOutputContact01 | 1.3.6.1.4.1.850.1.3.3.5.4.1 | Output contact 1 is in alarm. | ||
| tlpEnvAlarmOutputContact02 | 1.3.6.1.4.1.850.1.3.3.5.4.2 | Output contact 2 is in alarm. | ||
| tlpEnvAlarmOutputContact03 | 1.3.6.1.4.1.850.1.3.3.5.4.3 | Output contact 3 is in alarm. | ||
| tlpEnvAlarmOutputContact04 | 1.3.6.1.4.1.850.1.3.3.5.4.4 | Output contact 4 is in alarm. | ||
| tlpEnvAlarms | 1.3.6.1.4.1.850.1.3.3.5 | |||
| tlpEnvAlarmTemperatureBeyondLimits | 1.3.6.1.4.1.850.1.3.3.5.1 | The temperature exceeds limits. | ||
| tlpEnvConfig | 1.3.6.1.4.1.850.1.1.3.3.5 | |||
| tlpEnvConfigEntry | 1.3.6.1.4.1.850.1.1.3.3.5.1.1 | not-accessible | An entry containing configuration options for a particular envirosenses. | |
| tlpEnvConfigTable | 1.3.6.1.4.1.850.1.1.3.3.5.1 | not-accessible | The configuration options of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses. Not all options are available on all envirosenses. | |
| tlpEnvDetail | 1.3.6.1.4.1.850.1.1.3.3.3 | |||
| tlpEnvHumidityEntry | 1.3.6.1.4.1.850.1.1.3.3.3.2.1 | not-accessible | An entry containing humidity details for a particular envirosense. | |
| INT tlpEnvHumidityHighLimit | 1.3.6.1.4.1.850.1.1.3.3.5.1.1.4 | INTEGER | read-write | The upper alarm limit for ambient humidity. |
| INT tlpEnvHumidityHumidity | 1.3.6.1.4.1.850.1.1.3.3.3.2.1.1 | INTEGER | read-only | The ambient humidity. |
| T/F tlpEnvHumidityInAlarm | 1.3.6.1.4.1.850.1.1.3.3.3.2.1.2 | TruthValue | read-only | Indicates whether or not humidity is in alarm. |
| INT tlpEnvHumidityLowLimit | 1.3.6.1.4.1.850.1.1.3.3.5.1.1.3 | INTEGER | read-write | The lower alarm limit for ambient humidity. |
| tlpEnvHumidityTable | 1.3.6.1.4.1.850.1.1.3.3.3.2 | not-accessible | The humidity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| tlpEnvIdent | 1.3.6.1.4.1.850.1.1.3.3.1 | |||
| tlpEnvIdentEntry | 1.3.6.1.4.1.850.1.1.3.3.1.2.1 | not-accessible | An entry containing details for a particular envirosense. | |
| T/F tlpEnvIdentHumiditySupported | 1.3.6.1.4.1.850.1.1.3.3.1.2.1.2 | TruthValue | read-only | Indicates whether or not temperature is supported. |
| U32 tlpEnvIdentNumEnvirosense | 1.3.6.1.4.1.850.1.1.3.3.1.1 | Unsigned32 | read-only | The number of envirosense devices that this agent is currently managing. |
| tlpEnvIdentTable | 1.3.6.1.4.1.850.1.1.3.3.1.2 | not-accessible | The identity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| T/F tlpEnvIdentTempSupported | 1.3.6.1.4.1.850.1.1.3.3.1.2.1.1 | TruthValue | read-only | Indicates whether or not temperature is supported. |
| INT tlpEnvInputContactCurrentState | 1.3.6.1.4.1.850.1.1.3.3.3.3.1.4 | INTEGER | read-only | The current state of the contact. |
| tlpEnvInputContactEntry | 1.3.6.1.4.1.850.1.1.3.3.3.3.1 | not-accessible | An entry containing input contact details for a particular envirosense. | |
| T/F tlpEnvInputContactInAlarm | 1.3.6.1.4.1.850.1.1.3.3.3.3.1.5 | TruthValue | read-only | Indicates whether or not the contact is in alarm. |
| U32 tlpEnvInputContactIndex | 1.3.6.1.4.1.850.1.1.3.3.3.3.1.1 | Unsigned32 | read-only | The table row index for the envirosense input contact details. |
| STR tlpEnvInputContactName | 1.3.6.1.4.1.850.1.1.3.3.3.3.1.2 | DisplayString | read-write | The name or description of the contact. |
| INT tlpEnvInputContactNormalState | 1.3.6.1.4.1.850.1.1.3.3.3.3.1.3 | INTEGER | read-write | The normal operating position of the contact. |
| tlpEnvInputContactTable | 1.3.6.1.4.1.850.1.1.3.3.3.3 | not-accessible | The input contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| tlpEnvirosense | 1.3.6.1.4.1.850.1.1.3.3 | |||
| U32 tlpEnvNumInputContacts | 1.3.6.1.4.1.850.1.1.3.3.1.2.1.3 | Unsigned32 | read-only | The number of input contacts supported by the envirosense. |
| U32 tlpEnvNumOutputContacts | 1.3.6.1.4.1.850.1.1.3.3.1.2.1.4 | Unsigned32 | read-only | The number of output contacts supported by the envirosense. |
| INT tlpEnvOutputContactCurrentState | 1.3.6.1.4.1.850.1.1.3.3.3.4.1.4 | INTEGER | read-write | The current state of the contact. |
| tlpEnvOutputContactEntry | 1.3.6.1.4.1.850.1.1.3.3.3.4.1 | not-accessible | An entry containing output contact details for a particular envirosense. | |
| T/F tlpEnvOutputContactInAlarm | 1.3.6.1.4.1.850.1.1.3.3.3.4.1.5 | TruthValue | read-only | Indicates whether or not the contact is in alarm. |
| U32 tlpEnvOutputContactIndex | 1.3.6.1.4.1.850.1.1.3.3.3.4.1.1 | Unsigned32 | read-only | The table row index for the envirosense output contact details. |
| STR tlpEnvOutputContactName | 1.3.6.1.4.1.850.1.1.3.3.3.4.1.2 | DisplayString | read-write | The name or description of the contact. |
| INT tlpEnvOutputContactNormalState | 1.3.6.1.4.1.850.1.1.3.3.3.4.1.3 | INTEGER | read-write | The normal operating position of the contact. |
| tlpEnvOutputContactTable | 1.3.6.1.4.1.850.1.1.3.3.3.4 | not-accessible | The output contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| I32 tlpEnvTemperatureC | 1.3.6.1.4.1.850.1.1.3.3.3.1.1.1 | Integer32 | read-only | The ambient temperature. |
| tlpEnvTemperatureEntry | 1.3.6.1.4.1.850.1.1.3.3.3.1.1 | not-accessible | An entry containing temperature details for a particular envirosense. | |
| I32 tlpEnvTemperatureF | 1.3.6.1.4.1.850.1.1.3.3.3.1.1.2 | Integer32 | read-only | The ambient temperature. |
| I32 tlpEnvTemperatureHighLimit | 1.3.6.1.4.1.850.1.1.3.3.5.1.1.2 | Integer32 | read-write | The upper alarm limit for ambient temperature. |
| T/F tlpEnvTemperatureInAlarm | 1.3.6.1.4.1.850.1.1.3.3.3.1.1.3 | TruthValue | read-only | Indicates whether or not temperature is in alarm. |
| I32 tlpEnvTemperatureLowLimit | 1.3.6.1.4.1.850.1.1.3.3.5.1.1.1 | Integer32 | read-write | The lower alarm limit for ambient temperature. |
| tlpEnvTemperatureTable | 1.3.6.1.4.1.850.1.1.3.3.3.1 | not-accessible | The temperature details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices. | |
| tlpHardware | 1.3.6.1.4.1.850.1.1 | |||
| tlpKvm | 1.3.6.1.4.1.850.1.1.3.6 | |||
| tlpKvmAlarms | 1.3.6.1.4.1.850.1.3.3.8 | |||
| tlpKvmConfig | 1.3.6.1.4.1.850.1.1.3.6.5 | |||
| tlpKvmControl | 1.3.6.1.4.1.850.1.1.3.6.4 | |||
| tlpKvmDetail | 1.3.6.1.4.1.850.1.1.3.6.3 | |||
| tlpKvmDevice | 1.3.6.1.4.1.850.1.1.3.6.2 | |||
| tlpKvmIdent | 1.3.6.1.4.1.850.1.1.3.6.1 | |||
| U32 tlpKvmIdentNumKvm | 1.3.6.1.4.1.850.1.1.3.6.1.1 | Unsigned32 | read-only | The number of kvm devices that this agent is currently managing. |
| tlpNotifications | 1.3.6.1.4.1.850.1.4.1 | |||
| NTF tlpNotificationsAlarmEntryAdded | 1.3.6.1.4.1.850.1.4.1.1 | This notification is sent each time an alarm condition is inserted into the device alarm table, tlpAlarmTable. | ||
| NTF tlpNotificationsAlarmEntryRemoved | 1.3.6.1.4.1.850.1.4.1.2 | This notification is sent each time an alarm condition is removed from the device alarm table, tlpAlarmTable. | ||
| tlpNotify | 1.3.6.1.4.1.850.1.4 | |||
| NTF tlpNotifySystemShutdown | 1.3.6.1.4.1.850.1.4.1.4 | Used to inform another entity of an agent's shutdown. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format) | ||
| NTF tlpNotifySystemStartup | 1.3.6.1.4.1.850.1.4.1.3 | Used to inform another entity of an agent's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format) | ||
| NTF tlpNotifySystemUpdate | 1.3.6.1.4.1.850.1.4.1.5 | Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format) | ||
| tlpPdu | 1.3.6.1.4.1.850.1.1.3.2 | |||
| tlpPduAlarmCircuitBreakerOpen | 1.3.6.1.4.1.850.1.3.3.4.7 | |||
| tlpPduAlarmCircuitBreakerOpen01 | 1.3.6.1.4.1.850.1.3.3.4.7.1 | Circuit breaker 1 is open. | ||
| tlpPduAlarmCircuitBreakerOpen02 | 1.3.6.1.4.1.850.1.3.3.4.7.2 | Circuit breaker 2 is open. | ||
| tlpPduAlarmCircuitBreakerOpen03 | 1.3.6.1.4.1.850.1.3.3.4.7.3 | Circuit breaker 3 is open. | ||
| tlpPduAlarmCircuitBreakerOpen04 | 1.3.6.1.4.1.850.1.3.3.4.7.4 | Circuit breaker 4 is open. | ||
| tlpPduAlarmCircuitBreakerOpen05 | 1.3.6.1.4.1.850.1.3.3.4.7.5 | Circuit breaker 5 is open. | ||
| tlpPduAlarmCircuitBreakerOpen06 | 1.3.6.1.4.1.850.1.3.3.4.7.6 | Circuit breaker 6 is open. | ||
| tlpPduAlarmCurrentAboveThreshold | 1.3.6.1.4.1.850.1.3.3.4.8 | |||
| tlpPduAlarmCurrentAboveThreshold1 | 1.3.6.1.4.1.850.1.3.3.4.8.1 | The output current on phase 1 exceeds load limits. | ||
| tlpPduAlarmCurrentAboveThreshold2 | 1.3.6.1.4.1.850.1.3.3.4.8.2 | The output current on phase 2 exceeds load limits. | ||
| tlpPduAlarmCurrentAboveThreshold3 | 1.3.6.1.4.1.850.1.3.3.4.8.3 | The output current on phase 3 exceeds load limits. | ||
| tlpPduAlarmInputBad | 1.3.6.1.4.1.850.1.3.3.4.2 | An input condition is out of tolerance. | ||
| tlpPduAlarmLoadLevelAboveThreshold | 1.3.6.1.4.1.850.1.3.3.4.1 | The load level is above the designated threshold. | ||
| tlpPduAlarmLoadOff | 1.3.6.1.4.1.850.1.3.3.4.6 | |||
| tlpPduAlarmLoadOff01 | 1.3.6.1.4.1.850.1.3.3.4.6.1 | Load 1 is off. | ||
| tlpPduAlarmLoadOff02 | 1.3.6.1.4.1.850.1.3.3.4.6.2 | Load 2 is off. | ||
| tlpPduAlarmLoadOff03 | 1.3.6.1.4.1.850.1.3.3.4.6.3 | Load 3 is off. | ||
| tlpPduAlarmLoadOff04 | 1.3.6.1.4.1.850.1.3.3.4.6.4 | Load 4 is off. | ||
| tlpPduAlarmLoadOff05 | 1.3.6.1.4.1.850.1.3.3.4.6.5 | Load 5 is off. | ||
| tlpPduAlarmLoadOff06 | 1.3.6.1.4.1.850.1.3.3.4.6.6 | Load 6 is off. | ||
| tlpPduAlarmLoadOff07 | 1.3.6.1.4.1.850.1.3.3.4.6.7 | Load 7 is off. | ||
| tlpPduAlarmLoadOff08 | 1.3.6.1.4.1.850.1.3.3.4.6.8 | Load 8 is off. | ||
| tlpPduAlarmLoadOff09 | 1.3.6.1.4.1.850.1.3.3.4.6.9 | Load 9 is off. | ||
| tlpPduAlarmLoadOff10 | 1.3.6.1.4.1.850.1.3.3.4.6.10 | Load 10 is off. | ||
| tlpPduAlarmLoadOff11 | 1.3.6.1.4.1.850.1.3.3.4.6.11 | Load 11 is off. | ||
| tlpPduAlarmLoadOff12 | 1.3.6.1.4.1.850.1.3.3.4.6.12 | Load 12 is off. | ||
| tlpPduAlarmLoadOff13 | 1.3.6.1.4.1.850.1.3.3.4.6.13 | Load 13 is off. | ||
| tlpPduAlarmLoadOff14 | 1.3.6.1.4.1.850.1.3.3.4.6.14 | Load 14 is off. | ||
| tlpPduAlarmLoadOff15 | 1.3.6.1.4.1.850.1.3.3.4.6.15 | Load 15 is off. | ||
| tlpPduAlarmLoadOff16 | 1.3.6.1.4.1.850.1.3.3.4.6.16 | Load 16 is off. | ||
| tlpPduAlarmLoadOff17 | 1.3.6.1.4.1.850.1.3.3.4.6.17 | Load 17 is off. | ||
| tlpPduAlarmLoadOff18 | 1.3.6.1.4.1.850.1.3.3.4.6.18 | Load 18 is off. | ||
| tlpPduAlarmLoadOff19 | 1.3.6.1.4.1.850.1.3.3.4.6.19 | Load 19 is off. | ||
| tlpPduAlarmLoadOff20 | 1.3.6.1.4.1.850.1.3.3.4.6.20 | Load 20 is off. | ||
| tlpPduAlarmLoadOff21 | 1.3.6.1.4.1.850.1.3.3.4.6.21 | Load 21 is off. | ||
| tlpPduAlarmLoadOff22 | 1.3.6.1.4.1.850.1.3.3.4.6.22 | Load 22 is off. | ||
| tlpPduAlarmLoadOff23 | 1.3.6.1.4.1.850.1.3.3.4.6.23 | Load 23 is off. | ||
| tlpPduAlarmLoadOff24 | 1.3.6.1.4.1.850.1.3.3.4.6.24 | Load 24 is off. | ||
| tlpPduAlarmLoadOff25 | 1.3.6.1.4.1.850.1.3.3.4.6.25 | Load 25 is off. | ||
| tlpPduAlarmLoadOff26 | 1.3.6.1.4.1.850.1.3.3.4.6.26 | Load 26 is off. | ||
| tlpPduAlarmLoadOff27 | 1.3.6.1.4.1.850.1.3.3.4.6.27 | Load 27 is off. | ||
| tlpPduAlarmLoadOff28 | 1.3.6.1.4.1.850.1.3.3.4.6.28 | Load 28 is off. | ||
| tlpPduAlarmLoadOff29 | 1.3.6.1.4.1.850.1.3.3.4.6.29 | Load 29 is off. | ||
| tlpPduAlarmLoadOff30 | 1.3.6.1.4.1.850.1.3.3.4.6.30 | Load 30 is off. | ||
| tlpPduAlarmLoadOff31 | 1.3.6.1.4.1.850.1.3.3.4.6.31 | Load 31 is off. | ||
| tlpPduAlarmLoadOff32 | 1.3.6.1.4.1.850.1.3.3.4.6.32 | Load 32 is off. | ||
| tlpPduAlarmLoadOff33 | 1.3.6.1.4.1.850.1.3.3.4.6.33 | Load 33 is off. | ||
| tlpPduAlarmLoadOff34 | 1.3.6.1.4.1.850.1.3.3.4.6.34 | Load 34 is off. | ||
| tlpPduAlarmLoadOff35 | 1.3.6.1.4.1.850.1.3.3.4.6.35 | Load 35 is off. | ||
| tlpPduAlarmLoadOff36 | 1.3.6.1.4.1.850.1.3.3.4.6.36 | Load 36 is off. | ||
| tlpPduAlarmLoadOff37 | 1.3.6.1.4.1.850.1.3.3.4.6.37 | Load 37 is off. | ||
| tlpPduAlarmLoadOff38 | 1.3.6.1.4.1.850.1.3.3.4.6.38 | Load 38 is off. | ||
| tlpPduAlarmLoadOff39 | 1.3.6.1.4.1.850.1.3.3.4.6.39 | Load 39 is off. | ||
| tlpPduAlarmLoadOff40 | 1.3.6.1.4.1.850.1.3.3.4.6.40 | Load 40 is off. | ||
| tlpPduAlarmLoadsNotAllOn | 1.3.6.1.4.1.850.1.3.3.4.9 | One of more loads are not on. | ||
| tlpPduAlarmOutputBad | 1.3.6.1.4.1.850.1.3.3.4.3 | An output condition (other than OutputOverload) is out of tolerance. | ||
| tlpPduAlarmOutputOff | 1.3.6.1.4.1.850.1.3.3.4.5 | The output of the pdu is in the off state. | ||
| tlpPduAlarmOutputOverload | 1.3.6.1.4.1.850.1.3.3.4.4 | The output load exceeds the pdu output capacity. | ||
| tlpPduAlarms | 1.3.6.1.4.1.850.1.3.3.4 | |||
| tlpPduBreaker | 1.3.6.1.4.1.850.1.1.3.2.3.5 | |||
| tlpPduBreakerEntry | 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1 | not-accessible | An entry containing information applicable to a particular bank breaker managed by this agent. | |
| U32 tlpPduBreakerIndex | 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.1 | Unsigned32 | read-only | The table row index for the pdu bank breaker. |
| INT tlpPduBreakerStatus | 1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.2 | INTEGER | read-only | Indicates whether the bank breaker is open(0), closed(1) or not installed(2). |
| tlpPduBreakerTable | 1.3.6.1.4.1.850.1.1.3.2.3.5.1 | not-accessible | A list of pdu bank breaker table entries. The number of entries is given by the value of tlpPduIdentNumBreakers. | |
| tlpPduCircuit | 1.3.6.1.4.1.850.1.1.3.2.3.4 | |||
| I32 tlpPduCircuitCurrentLimit | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.5 | Integer32 | read-only | The current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit. |
| I32 tlpPduCircuitCurrentMax | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.7 | Integer32 | read-only | The maximum total current for all receptacles in a given circuit since last reset. |
| I32 tlpPduCircuitCurrentMin | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.6 | Integer32 | read-only | The minimum total current for all receptacles in a given circuit since last reset. |
| tlpPduCircuitEntry | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1 | not-accessible | An entry containing information applicable to a particular circuit managed by this agent. | |
| U32 tlpPduCircuitIndex | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.1 | Unsigned32 | read-only | The table row index for the pdu circuit. |
| I32 tlpPduCircuitInputVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.3 | Integer32 | read-only | The input voltage for a circuit. |
| INT tlpPduCircuitPhase | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.2 | INTEGER | read-only | Indicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0). |
| INT tlpPduCircuitPowerFactor | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.9 | INTEGER | read-only | The power factor for all receptacles in a given circuit. |
| tlpPduCircuitTable | 1.3.6.1.4.1.850.1.1.3.2.3.4.1 | not-accessible | A list of pdu circuit table entries. The number of entries is given by the value of tlpPduIdentNumCircuits. | |
| I32 tlpPduCircuitTotalCurrent | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4 | Integer32 | read-only | The total current for all receptacles in a given circuit. |
| I32 tlpPduCircuitTotalPower | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.8 | Integer32 | read-only | The total power for all receptacles in a given circuit. |
| U32 tlpPduCircuitUtilization | 1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.10 | Unsigned32 | read-only | The percentage of utilization of a given circuit. This is typically a calculation of tlpPduCircuitTotalCurrent / tlpPduCircuitCurrentLimit. |
| tlpPduConfig | 1.3.6.1.4.1.850.1.1.3.2.5 | |||
| tlpPduConfigEntry | 1.3.6.1.4.1.850.1.1.3.2.5.1.1 | not-accessible | An entry containing configuration options for a particular pdu. | |
| U32 tlpPduConfigInputVoltage | 1.3.6.1.4.1.850.1.1.3.2.5.1.1.1 | Unsigned32 | read-write | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. |
| tlpPduConfigTable | 1.3.6.1.4.1.850.1.1.3.2.5.1 | not-accessible | The configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus. | |
| tlpPduControl | 1.3.6.1.4.1.850.1.1.3.2.4 | |||
| tlpPduControlEntry | 1.3.6.1.4.1.850.1.1.3.2.4.1.1 | not-accessible | An entry containing controls for a particular pdu. | |
| T/F tlpPduControlPduOff | 1.3.6.1.4.1.850.1.1.3.2.4.1.1.4 | TruthValue | read-write | Set to TRUE to turn the pdu off. |
| T/F tlpPduControlPduOn | 1.3.6.1.4.1.850.1.1.3.2.4.1.1.3 | TruthValue | read-write | Set to TRUE to turn the pdu on. |
| T/F tlpPduControlPduReboot | 1.3.6.1.4.1.850.1.1.3.2.4.1.1.5 | TruthValue | read-write | Set to TRUE to reboot the pdu. |
| T/F tlpPduControlRamp | 1.3.6.1.4.1.850.1.1.3.2.4.1.1.1 | TruthValue | read-write | Set to TRUE to initiate the pre-designated ramp sequence on the pdu. |
| T/F tlpPduControlShed | 1.3.6.1.4.1.850.1.1.3.2.4.1.1.2 | TruthValue | read-write | Set to TRUE to initiate the pre-designated shed sequence on the pdu. |
| tlpPduControlTable | 1.3.6.1.4.1.850.1.1.3.2.4.1 | not-accessible | The actionable controls for each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. | |
| tlpPduDetail | 1.3.6.1.4.1.850.1.1.3.2.3 | |||
| tlpPduDevice | 1.3.6.1.4.1.850.1.1.3.2.2 | |||
| U32 tlpPduDeviceAggregatePowerFactor | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.10 | Unsigned32 | read-only | The aggregrate power factor of all phases. |
| tlpPduDeviceEntry | 1.3.6.1.4.1.850.1.1.3.2.2.1.1 | not-accessible | An entry containing device details for a particular pdu. | |
| INT tlpPduDeviceMainLoadCommand | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.3 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on. |
| T/F tlpPduDeviceMainLoadControllable | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.2 | TruthValue | read-only | Indicates whether or not the main output is controllable, and whether the ups can be turned off and on. |
| INT tlpPduDeviceMainLoadState | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.1 | INTEGER | read-only | The current state of the main output of the device. |
| INT tlpPduDeviceOutputCurrentPrecision | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.11 | INTEGER | read-only | Output current is reported by tlpPduOutputCurrent, tlpPduOutputCurrentMin and tlpPduOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpPduOutputCurrent reports 530 and tlpPduDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3. |
| U32 tlpPduDeviceOutputPowerTotal | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.9 | Unsigned32 | read-only | The AC output total power for all circuits. |
| INT tlpPduDevicePhaseImbalance | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.8 | INTEGER | read-only | The percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%. |
| I32 tlpPduDevicePowerOnDelay | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.4 | Integer32 | read-write | The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source. |
| tlpPduDeviceTable | 1.3.6.1.4.1.850.1.1.3.2.2.1 | not-accessible | The device details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. | |
| I32 tlpPduDeviceTemperatureC | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.6 | Integer32 | read-only | The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpPduDeviceTemperatureF | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.7 | Integer32 | read-only | The ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpPduDeviceTotalInputPowerRating | 1.3.6.1.4.1.850.1.1.3.2.2.1.1.5 | Integer32 | read-only | The total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpPduDisplayAutoScroll | 1.3.6.1.4.1.850.1.1.3.2.1.4.1.3 | INTEGER | read-write | Indicates whether the LED display automatically scrolls through displaying status values. |
| tlpPduDisplayEntry | 1.3.6.1.4.1.850.1.1.3.2.1.4.1 | not-accessible | An entry containing display details for a particular pdu. | |
| INT tlpPduDisplayIntensity | 1.3.6.1.4.1.850.1.1.3.2.1.4.1.4 | INTEGER | read-write | Indicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted. |
| INT tlpPduDisplayOrientation | 1.3.6.1.4.1.850.1.1.3.2.1.4.1.2 | INTEGER | read-write | Indicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0). |
| INT tlpPduDisplayScheme | 1.3.6.1.4.1.850.1.1.3.2.1.4.1.1 | INTEGER | read-write | Indicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1). |
| tlpPduDisplayTable | 1.3.6.1.4.1.850.1.1.3.2.1.4 | not-accessible | The display details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. | |
| INT tlpPduDisplayUnits | 1.3.6.1.4.1.850.1.1.3.2.1.4.1.5 | INTEGER | read-write | Indicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Farenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius. |
| tlpPduHeatsink | 1.3.6.1.4.1.850.1.1.3.2.3.6 | |||
| tlpPduHeatsinkEntry | 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1 | not-accessible | An entry containing information applicable to a particular heatsink thermistor managed by this agent. | |
| U32 tlpPduHeatsinkIndex | 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.1 | Unsigned32 | read-only | The table row index for the pdu heatsink thermistor. |
| INT tlpPduHeatsinkStatus | 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.2 | INTEGER | read-only | Indicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected. |
| tlpPduHeatsinkTable | 1.3.6.1.4.1.850.1.1.3.2.3.6.1 | not-accessible | A list of pdu heatsink thermistor table entries. The number of entries is given by the value of tlpPduIdentNumHeatsinks. | |
| I32 tlpPduHeatsinkTemperatureC | 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.3 | Integer32 | read-only | The temperature at the heatsink termistor in tenths degrees Centigrade. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpPduHeatsinkTemperatureF | 1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.4 | Integer32 | read-only | The temperature at the heatsink termistor in tenths degrees Farenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| tlpPduIdent | 1.3.6.1.4.1.850.1.1.3.2.1 | |||
| tlpPduIdentEntry | 1.3.6.1.4.1.850.1.1.3.2.1.2.1 | not-accessible | An entry containing details for a particular pdu. | |
| U32 tlpPduIdentNumBreakers | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.7 | Unsigned32 | read-only | The number of bank breakers supported by the pdu. |
| U32 tlpPduIdentNumCircuits | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.6 | Unsigned32 | read-only | The number of circuits supported by the pdu. |
| U32 tlpPduIdentNumHeatsinks | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.8 | Unsigned32 | read-only | The number of heatsink thermistors supported by the pdu. |
| U32 tlpPduIdentNumInputs | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.1 | Unsigned32 | read-only | The number of input lines supported by the pdu. |
| U32 tlpPduIdentNumOutletGroups | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.5 | Unsigned32 | read-only | The number of receptacle groups supported by the pdu. |
| U32 tlpPduIdentNumOutlets | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.4 | Unsigned32 | read-only | The number of receptacles supported by the pdu. |
| U32 tlpPduIdentNumOutputs | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.2 | Unsigned32 | read-only | The number of output lines supported by the pdu. |
| U32 tlpPduIdentNumPdu | 1.3.6.1.4.1.850.1.1.3.2.1.1 | Unsigned32 | read-only | The number of pdu devices that this agent is currently managing. |
| U32 tlpPduIdentNumPhases | 1.3.6.1.4.1.850.1.1.3.2.1.2.1.3 | Unsigned32 | read-only | The number of phases supported by the pdu. |
| tlpPduIdentTable | 1.3.6.1.4.1.850.1.1.3.2.1.2 | not-accessible | The identity details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. | |
| tlpPduInput | 1.3.6.1.4.1.850.1.1.3.2.3.1 | |||
| U32 tlpPduInputCurrentLimit | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.10 | Unsigned32 | read-only | The capacity of each phase conductor in the pdu limited by the AC input cord or any other potential limiting factors unique to a given unit. |
| tlpPduInputEntry | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1 | not-accessible | An entry containing information applicable to a particular pdu managed by this agent. | |
| U32 tlpPduInputHighTransferVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.7 | Unsigned32 | read-only | The maximum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound respectively. |
| U32 tlpPduInputHighTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.8 | Unsigned32 | read-only | The lower boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpPduInputHighTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.9 | Unsigned32 | read-only | The upper boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpPduInputLowTransferVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.4 | Unsigned32 | read-only | The minimum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputLowTransferVoltageLowerBound and tlpPduInputLowTransferVoltageUpperBound respectively. |
| U32 tlpPduInputLowTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5 | Unsigned32 | read-only | The lower boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpPduInputLowTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.6 | Unsigned32 | read-only | The upper boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpPduInputNominalVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.1 | Unsigned32 | read-only | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpPduInputNominalVoltagePhaseToNeutral | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.3 | Unsigned32 | read-only | The nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero. |
| U32 tlpPduInputNominalVoltagePhaseToPhase | 1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.2 | Unsigned32 | read-only | The nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero. |
| U32 tlpPduInputPhaseCurrent | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.7 | Unsigned32 | read-only | The magnitude of the present input current for a given phase. |
| tlpPduInputPhaseEntry | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1 | not-accessible | An entry containing information applicable to a particular input phase managed by this agent. | |
| U32 tlpPduInputPhaseFrequency | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.3 | Unsigned32 | read-only | The present input frequency for a given phase. |
| U32 tlpPduInputPhaseIndex | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.1 | Unsigned32 | read-only | The table row index for the pdu phase. |
| INT tlpPduInputPhasePhaseType | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.2 | INTEGER | read-only | Denotes whether measurements are phase to neutral(0) or phase to phase(1). |
| tlpPduInputPhaseTable | 1.3.6.1.4.1.850.1.1.3.2.3.1.2 | not-accessible | The input phase details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumInputs and tlpPduIdentNumPhases per each device. | |
| U32 tlpPduInputPhaseVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4 | Unsigned32 | read-only | The magnitude of the present input voltage for a given phase. |
| U32 tlpPduInputPhaseVoltageMax | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.6 | Unsigned32 | read-write | The maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| U32 tlpPduInputPhaseVoltageMin | 1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.5 | Unsigned32 | read-write | The minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| tlpPduInputTable | 1.3.6.1.4.1.850.1.1.3.2.3.1.1 | not-accessible | The input details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of pdus managed by the agent as reported by tlpPduIdentNumPdus. | |
| tlpPduOutlet | 1.3.6.1.4.1.850.1.1.3.2.3.3 | |||
| I32 tlpPduOutletBank | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.15 | Integer32 | read-only | Indicates on which bank the given outlet is located. |
| I32 tlpPduOutletCircuit | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.16 | Integer32 | read-only | Indicates on which circuit the given outlet is wired. |
| INT tlpPduOutletCommand | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on. |
| T/F tlpPduOutletControllable | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.5 | TruthValue | read-only | Denotes whether this outlet is controllable. |
| U32 tlpPduOutletCurrent | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.8 | Unsigned32 | read-only | The present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpPduSupportsCurrentPower. |
| STR tlpPduOutletDescription | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.3 | DisplayString | read-write | A user-definable string identifying the device(s) connected to the given outlet. |
| tlpPduOutletEntry | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1 | not-accessible | An entry containing information applicable to a particular outlet managed by this agent. | |
| I32 tlpPduOutletGroup | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.14 | Integer32 | read-write | The tlpPduOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped. |
| INT tlpPduOutletGroupCommand | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on. |
| STR tlpPduOutletGroupDescription | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.4 | DisplayString | read-write | A description for this outlet group. |
| tlpPduOutletGroupEntry | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1 | not-accessible | An entry containing information applicable to a particular outlet group managed by this agent. | |
| U32 tlpPduOutletGroupIndex | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.1 | Unsigned32 | read-only | The table row index for the pdu outlet group. |
| STR tlpPduOutletGroupName | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.3 | DisplayString | read-write | The name of this outlet group. |
| ROW tlpPduOutletGroupRowStatus | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.2 | RowStatus | read-write | Row status for the tlpPduOutletGroupTable |
| INT tlpPduOutletGroupState | 1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.5 | INTEGER | read-only | The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined. |
| tlpPduOutletGroupTable | 1.3.6.1.4.1.850.1.1.3.2.3.3.2 | not-accessible | The receptacle grouping details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutletGroups per each device. | |
| U32 tlpPduOutletIndex | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.1 | Unsigned32 | read-only | The table row index for the pdu outlet. |
| STR tlpPduOutletName | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.2 | DisplayString | read-write | A user-definable string identifying the name of the outlet. |
| INT tlpPduOutletPhase | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.17 | INTEGER | read-only | Indicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0). |
| U32 tlpPduOutletPower | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.9 | Unsigned32 | read-only | The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpPduSupportsCurrentPower. |
| INT tlpPduOutletRampAction | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.10 | INTEGER | read-write | The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpPduOutletRampDelay | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.11 | Integer32 | read-write | The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpPduOutletShedAction | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.12 | INTEGER | read-write | The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpPduOutletShedDelay | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.13 | Integer32 | read-write | The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpPduOutletState | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.4 | INTEGER | read-only | The current state of the outlet. |
| tlpPduOutletTable | 1.3.6.1.4.1.850.1.1.3.2.3.3.1 | not-accessible | The receptacle status details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutlets per each device. | |
| U32 tlpPduOutletVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.7 | Unsigned32 | read-only | The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpPduSupportsOutletVoltage. |
| tlpPduOutput | 1.3.6.1.4.1.850.1.1.3.2.3.2 | |||
| U32 tlpPduOutputActivePower | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.8 | Unsigned32 | read-only | The output power for a given phase. |
| U32 tlpPduOutputCurrent | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.5 | Unsigned32 | read-only | The output current, in hundreths of amps, for a given phase. |
| U32 tlpPduOutputCurrentMax | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.7 | Unsigned32 | read-only | The maximum current observed for a given phase since last reset. |
| U32 tlpPduOutputCurrentMin | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.6 | Unsigned32 | read-only | The minimum current observed for a given phase since last reset. |
| tlpPduOutputEntry | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1 | not-accessible | An entry containing output information applicable to a particular phase managed by this agent. | |
| U32 tlpPduOutputIndex | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.1 | Unsigned32 | read-only | The table row index for the pdu phase. |
| INT tlpPduOutputPhase | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.2 | INTEGER | read-only | Indicates the phase associated with the output line. |
| INT tlpPduOutputPhaseType | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.3 | INTEGER | read-only | Denotes whether measurements are phase to neutral(0) or phase to phase(1). |
| U32 tlpPduOutputPowerFactor | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.9 | Unsigned32 | read-only | The output power factor, in hundreths of a percent, for a given phase. |
| INT tlpPduOutputSource | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.10 | INTEGER | read-only | The present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker. |
| tlpPduOutputTable | 1.3.6.1.4.1.850.1.1.3.2.3.2.1 | not-accessible | The output details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutputs per each device. | |
| U32 tlpPduOutputVoltage | 1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.4 | Unsigned32 | read-only | The magnitude of the present output voltage for a given output line. |
| T/F tlpPduSupportsEnergywise | 1.3.6.1.4.1.850.1.1.3.2.1.3.1.1 | TruthValue | read-only | Indicates whether the pdu supports Cisco EnergyWise. |
| tlpPduSupportsEntry | 1.3.6.1.4.1.850.1.1.3.2.1.3.1 | not-accessible | An entry containing supported details for a particular pdu. | |
| T/F tlpPduSupportsOutletCurrentPower | 1.3.6.1.4.1.850.1.1.3.2.1.3.1.4 | TruthValue | read-only | Indicates whether the pdu reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletCurrent and tlpPduOutletPower. |
| T/F tlpPduSupportsOutletGroup | 1.3.6.1.4.1.850.1.1.3.2.1.3.1.3 | TruthValue | read-only | Indicates whether the pdu supports outlet groups. |
| T/F tlpPduSupportsOutletVoltage | 1.3.6.1.4.1.850.1.1.3.2.1.3.1.5 | TruthValue | read-only | Indicates whether the pdu reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletVoltage. |
| T/F tlpPduSupportsRampShed | 1.3.6.1.4.1.850.1.1.3.2.1.3.1.2 | TruthValue | read-only | Indicates whether the pdu supports ramping and shedding. |
| tlpPduSupportsTable | 1.3.6.1.4.1.850.1.1.3.2.1.3 | not-accessible | The supported details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. | |
| tlpProducts | 1.3.6.1.4.1.850.1 | This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripp Lite PowerAlert and related software. | ||
| tlpRackTrack | 1.3.6.1.4.1.850.1.1.3.7 | |||
| tlpRackTrackAlarms | 1.3.6.1.4.1.850.1.3.3.9 | |||
| tlpRackTrackConfig | 1.3.6.1.4.1.850.1.1.3.7.5 | |||
| tlpRackTrackControl | 1.3.6.1.4.1.850.1.1.3.7.4 | |||
| tlpRackTrackDetail | 1.3.6.1.4.1.850.1.1.3.7.3 | |||
| tlpRackTrackDevice | 1.3.6.1.4.1.850.1.1.3.7.2 | |||
| tlpRackTrackIdent | 1.3.6.1.4.1.850.1.1.3.7.1 | |||
| U32 tlpRackTrackIdentNumRackTrack | 1.3.6.1.4.1.850.1.1.3.7.1.1 | Unsigned32 | read-only | The number of rack track devices that this agent is currently managing. |
| tlpSoftware | 1.3.6.1.4.1.850.1.2 | |||
| tlpSwitch | 1.3.6.1.4.1.850.1.1.3.8 | |||
| tlpSwitchAlarms | 1.3.6.1.4.1.850.1.3.3.10 | |||
| tlpSwitchConfig | 1.3.6.1.4.1.850.1.1.3.8.5 | |||
| tlpSwitchControl | 1.3.6.1.4.1.850.1.1.3.8.4 | |||
| tlpSwitchDetail | 1.3.6.1.4.1.850.1.1.3.8.3 | |||
| tlpSwitchDevice | 1.3.6.1.4.1.850.1.1.3.8.2 | |||
| tlpSwitchIdent | 1.3.6.1.4.1.850.1.1.3.8.1 | |||
| U32 tlpSwitchIdentNumSwitch | 1.3.6.1.4.1.850.1.1.3.8.1.1 | Unsigned32 | read-only | The number of switch devices that this agent is currently managing. |
| tlpUps | 1.3.6.1.4.1.850.1.1.3.1 | |||
| tlpUpsAlarmAwaitingPower | 1.3.6.1.4.1.850.1.3.3.3.20 | The UPS output is off and the UPS is awaiting the return of input power. | ||
| tlpUpsAlarmBatteryAgeAboveThreshold | 1.3.6.1.4.1.850.1.3.3.3.25 | One or more batteries have been determined to require replacement. | ||
| tlpUpsAlarmBatteryBad | 1.3.6.1.4.1.850.1.3.3.3.1 | One or more batteries have been determined to require replacement. | ||
| tlpUpsAlarmBatteryOverVoltage | 1.3.6.1.4.1.850.1.3.3.3.37 | The battery voltage is too high. | ||
| tlpUpsAlarmBatteryUnderVoltage | 1.3.6.1.4.1.850.1.3.3.3.38 | The battery voltage is too low. | ||
| tlpUpsAlarmBusOverVoltage | 1.3.6.1.4.1.850.1.3.3.3.30 | The inverter bus voltage is too high. | ||
| tlpUpsAlarmBusStartVoltageLow | 1.3.6.1.4.1.850.1.3.3.3.29 | The inverter start up bus voltage is too low. | ||
| tlpUpsAlarmBusUnderVoltage | 1.3.6.1.4.1.850.1.3.3.3.31 | The inverter bus voltage is too low. | ||
| tlpUpsAlarmBusVoltageUnbalanced | 1.3.6.1.4.1.850.1.3.3.3.32 | The inverter bus voltage is not balanced. | ||
| tlpUpsAlarmBypassBad | 1.3.6.1.4.1.850.1.3.3.3.10 | The Bypass is out of tolerance. | ||
| tlpUpsAlarmBypassFrequencyBad | 1.3.6.1.4.1.850.1.3.3.3.43 | The bypass frequency is out of tolerance. | ||
| tlpUpsAlarmChargerFailed | 1.3.6.1.4.1.850.1.3.3.3.13 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| tlpUpsAlarmCurrentAboveThreshold | 1.3.6.1.4.1.850.1.3.3.3.27 | |||
| tlpUpsAlarmCurrentAboveThreshold1 | 1.3.6.1.4.1.850.1.3.3.3.27.1 | The output current on phase 1 exceeds load limits. | ||
| tlpUpsAlarmCurrentAboveThreshold2 | 1.3.6.1.4.1.850.1.3.3.3.27.2 | The output current on phase 2 exceeds load limits. | ||
| tlpUpsAlarmCurrentAboveThreshold3 | 1.3.6.1.4.1.850.1.3.3.3.27.3 | The output current on phase 3 exceeds load limits. | ||
| tlpUpsAlarmDepletedBattery | 1.3.6.1.4.1.850.1.3.3.3.4 | The UPS will be unable to sustain the present load when and if the utility power is lost. | ||
| tlpUpsAlarmDiagnosticTestFailed | 1.3.6.1.4.1.850.1.3.3.3.19 | The result of the last diagnostic test indicates a failure. | ||
| tlpUpsAlarmEPOActive | 1.3.6.1.4.1.850.1.3.3.3.42 | The EPO is currently activate. | ||
| tlpUpsAlarmExternalNonSmartBatteryAgeAboveThreshold | 1.3.6.1.4.1.850.1.3.3.3.45 | One or more external non-smart batteries have been determined to require replacement. | ||
| tlpUpsAlarmExternalSmartBatteryAgeAboveThreshold | 1.3.6.1.4.1.850.1.3.3.3.44 | One or more external smart batteries have been determined to require replacement. | ||
| tlpUpsAlarmFanFailure | 1.3.6.1.4.1.850.1.3.3.3.16 | The failure of one or more fans in the UPS has been detected. | ||
| tlpUpsAlarmFuseFailure | 1.3.6.1.4.1.850.1.3.3.3.17 | The failure of one or more fuses has been detected. | ||
| tlpUpsAlarmGeneralFault | 1.3.6.1.4.1.850.1.3.3.3.18 | A general fault in the UPS has been detected. | ||
| tlpUpsAlarmInputBad | 1.3.6.1.4.1.850.1.3.3.3.6 | An input condition is out of tolerance. | ||
| tlpUpsAlarmInverterCircuitBad | 1.3.6.1.4.1.850.1.3.3.3.36 | The inverter output is shorted. | ||
| tlpUpsAlarmInverterOverVoltage | 1.3.6.1.4.1.850.1.3.3.3.34 | The inverter voltage is too high. | ||
| tlpUpsAlarmInverterSoftStartBad | 1.3.6.1.4.1.850.1.3.3.3.33 | The inverter bus voltage cannot reach desired voltage within a specified duration. | ||
| tlpUpsAlarmInverterUnderVoltage | 1.3.6.1.4.1.850.1.3.3.3.35 | The inverter voltage is too low. | ||
| tlpUpsAlarmLoadLevelAboveThreshold | 1.3.6.1.4.1.850.1.3.3.3.23 | |||
| tlpUpsAlarmLoadLevelAboveThresholdPhase1 | 1.3.6.1.4.1.850.1.3.3.3.23.2 | The load level on phase 1 exceeds load limits. | ||
| tlpUpsAlarmLoadLevelAboveThresholdPhase2 | 1.3.6.1.4.1.850.1.3.3.3.23.3 | The load level on phase 2 exceeds load limits. | ||
| tlpUpsAlarmLoadLevelAboveThresholdPhase3 | 1.3.6.1.4.1.850.1.3.3.3.23.4 | The load level on phase 3 exceeds load limits. | ||
| tlpUpsAlarmLoadLevelAboveThresholdTotal | 1.3.6.1.4.1.850.1.3.3.3.23.1 | The total load level is above the designated threshold. | ||
| tlpUpsAlarmLoadOff | 1.3.6.1.4.1.850.1.3.3.3.26 | |||
| tlpUpsAlarmLoadOff01 | 1.3.6.1.4.1.850.1.3.3.3.26.1 | Load 1 is off. | ||
| tlpUpsAlarmLoadOff02 | 1.3.6.1.4.1.850.1.3.3.3.26.2 | Load 2 is off. | ||
| tlpUpsAlarmLoadOff03 | 1.3.6.1.4.1.850.1.3.3.3.26.3 | Load 3 is off. | ||
| tlpUpsAlarmLoadOff04 | 1.3.6.1.4.1.850.1.3.3.3.26.4 | Load 4 is off. | ||
| tlpUpsAlarmLoadOff05 | 1.3.6.1.4.1.850.1.3.3.3.26.5 | Load 5 is off. | ||
| tlpUpsAlarmLoadOff06 | 1.3.6.1.4.1.850.1.3.3.3.26.6 | Load 6 is off. | ||
| tlpUpsAlarmLoadOff07 | 1.3.6.1.4.1.850.1.3.3.3.26.7 | Load 7 is off. | ||
| tlpUpsAlarmLoadOff08 | 1.3.6.1.4.1.850.1.3.3.3.26.8 | Load 8 is off. | ||
| tlpUpsAlarmLoadOff09 | 1.3.6.1.4.1.850.1.3.3.3.26.9 | Load 9 is off. | ||
| tlpUpsAlarmLoadOff10 | 1.3.6.1.4.1.850.1.3.3.3.26.10 | Load 10 is off. | ||
| tlpUpsAlarmLoadOff11 | 1.3.6.1.4.1.850.1.3.3.3.26.11 | Load 11 is off. | ||
| tlpUpsAlarmLoadOff12 | 1.3.6.1.4.1.850.1.3.3.3.26.12 | Load 12 is off. | ||
| tlpUpsAlarmLoadOff13 | 1.3.6.1.4.1.850.1.3.3.3.26.13 | Load 13 is off. | ||
| tlpUpsAlarmLoadOff14 | 1.3.6.1.4.1.850.1.3.3.3.26.14 | Load 14 is off. | ||
| tlpUpsAlarmLoadOff15 | 1.3.6.1.4.1.850.1.3.3.3.26.15 | Load 15 is off. | ||
| tlpUpsAlarmLoadOff16 | 1.3.6.1.4.1.850.1.3.3.3.26.16 | Load 16 is off. | ||
| tlpUpsAlarmLoadOff17 | 1.3.6.1.4.1.850.1.3.3.3.26.17 | Load 17 is off. | ||
| tlpUpsAlarmLoadOff18 | 1.3.6.1.4.1.850.1.3.3.3.26.18 | Load 18 is off. | ||
| tlpUpsAlarmLoadOff19 | 1.3.6.1.4.1.850.1.3.3.3.26.19 | Load 19 is off. | ||
| tlpUpsAlarmLoadOff20 | 1.3.6.1.4.1.850.1.3.3.3.26.20 | Load 20 is off. | ||
| tlpUpsAlarmLoadOff21 | 1.3.6.1.4.1.850.1.3.3.3.26.21 | Load 21 is off. | ||
| tlpUpsAlarmLoadOff22 | 1.3.6.1.4.1.850.1.3.3.3.26.22 | Load 22 is off. | ||
| tlpUpsAlarmLoadOff23 | 1.3.6.1.4.1.850.1.3.3.3.26.23 | Load 23 is off. | ||
| tlpUpsAlarmLoadOff24 | 1.3.6.1.4.1.850.1.3.3.3.26.24 | Load 24 is off. | ||
| tlpUpsAlarmLoadOff25 | 1.3.6.1.4.1.850.1.3.3.3.26.25 | Load 25 is off. | ||
| tlpUpsAlarmLoadOff26 | 1.3.6.1.4.1.850.1.3.3.3.26.26 | Load 26 is off. | ||
| tlpUpsAlarmLoadOff27 | 1.3.6.1.4.1.850.1.3.3.3.26.27 | Load 27 is off. | ||
| tlpUpsAlarmLoadOff28 | 1.3.6.1.4.1.850.1.3.3.3.26.28 | Load 28 is off. | ||
| tlpUpsAlarmLoadOff29 | 1.3.6.1.4.1.850.1.3.3.3.26.29 | Load 29 is off. | ||
| tlpUpsAlarmLoadOff30 | 1.3.6.1.4.1.850.1.3.3.3.26.30 | Load 30 is off. | ||
| tlpUpsAlarmLoadOff31 | 1.3.6.1.4.1.850.1.3.3.3.26.31 | Load 31 is off. | ||
| tlpUpsAlarmLoadOff32 | 1.3.6.1.4.1.850.1.3.3.3.26.32 | Load 32 is off. | ||
| tlpUpsAlarmLoadOff33 | 1.3.6.1.4.1.850.1.3.3.3.26.33 | Load 33 is off. | ||
| tlpUpsAlarmLoadOff34 | 1.3.6.1.4.1.850.1.3.3.3.26.34 | Load 34 is off. | ||
| tlpUpsAlarmLoadOff35 | 1.3.6.1.4.1.850.1.3.3.3.26.35 | Load 35 is off. | ||
| tlpUpsAlarmLoadOff36 | 1.3.6.1.4.1.850.1.3.3.3.26.36 | Load 36 is off. | ||
| tlpUpsAlarmLoadOff37 | 1.3.6.1.4.1.850.1.3.3.3.26.37 | Load 37 is off. | ||
| tlpUpsAlarmLoadOff38 | 1.3.6.1.4.1.850.1.3.3.3.26.38 | Load 38 is off. | ||
| tlpUpsAlarmLoadOff39 | 1.3.6.1.4.1.850.1.3.3.3.26.39 | Load 39 is off. | ||
| tlpUpsAlarmLoadOff40 | 1.3.6.1.4.1.850.1.3.3.3.26.40 | Load 40 is off. | ||
| tlpUpsAlarmLoadsNotAllOn | 1.3.6.1.4.1.850.1.3.3.3.47 | One of more loads are not on. | ||
| tlpUpsAlarmLowBattery | 1.3.6.1.4.1.850.1.3.3.3.3 | The remaining battery charge is less than or equal to the percentage of capacity warning specified by tlpUpsConfigBatteryCapacityThreshold. | ||
| tlpUpsAlarmOnBattery | 1.3.6.1.4.1.850.1.3.3.3.2 | The UPS is drawing power from the batteries. | ||
| tlpUpsAlarmOnBypass | 1.3.6.1.4.1.850.1.3.3.3.9 | The Bypass is presently engaged on the UPS. | ||
| tlpUpsAlarmOutputBad | 1.3.6.1.4.1.850.1.3.3.3.7 | An output condition (other than OutputOverload) is out of tolerance. | ||
| tlpUpsAlarmOutputCurrentChanged | 1.3.6.1.4.1.850.1.3.3.3.24 | The output current changed from its last known value. | ||
| tlpUpsAlarmOutputOffAsRequested | 1.3.6.1.4.1.850.1.3.3.3.11 | The UPS has shutdown as requested, i.e., the output is off. | ||
| tlpUpsAlarmOutputOverload | 1.3.6.1.4.1.850.1.3.3.3.8 | The output load exceeds the UPS output capacity. | ||
| tlpUpsAlarmOverCharged | 1.3.6.1.4.1.850.1.3.3.3.41 | The UPS is over charged. | ||
| tlpUpsAlarmOverTemperatureProtection | 1.3.6.1.4.1.850.1.3.3.3.40 | The over temperature protection is activated. | ||
| tlpUpsAlarmRuntimeBelowWarningLevel | 1.3.6.1.4.1.850.1.3.3.3.28 | The battery seconds remaining is below warning level. | ||
| tlpUpsAlarms | 1.3.6.1.4.1.850.1.3.3.3 | |||
| tlpUpsAlarmShutdownImminent | 1.3.6.1.4.1.850.1.3.3.3.22 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| tlpUpsAlarmShutdownPending | 1.3.6.1.4.1.850.1.3.3.3.21 | A tlpUpsShutdownAfterDelay countdown is underway. | ||
| tlpUpsAlarmSiteWiringFault | 1.3.6.1.4.1.850.1.3.3.3.39 | The utility input wiring is faulty. | ||
| tlpUpsAlarmSmartBatteryCommLost | 1.3.6.1.4.1.850.1.3.3.3.46 | Communications with the smart batteries was lost. | ||
| tlpUpsAlarmTempBad | 1.3.6.1.4.1.850.1.3.3.3.5 | A temperature is out of tolerance. | ||
| tlpUpsAlarmUpsOffAsRequested | 1.3.6.1.4.1.850.1.3.3.3.12 | The entire UPS has shutdown as commanded. | ||
| tlpUpsAlarmUpsOutputOff | 1.3.6.1.4.1.850.1.3.3.3.14 | The output of the UPS is in the off state. | ||
| tlpUpsAlarmUpsSystemOff | 1.3.6.1.4.1.850.1.3.3.3.15 | The UPS system is in the off state. | ||
| tlpUpsBattery | 1.3.6.1.4.1.850.1.1.3.1.3.1 | |||
| INT tlpUpsBatteryDetailCapacity | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.3 | INTEGER | read-only | The estimated remaining battery capacity expressed as a percent of full capacity. |
| INT tlpUpsBatteryDetailCharge | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.4 | INTEGER | read-only | Denotes the charge state of the battery. |
| INT tlpUpsBatteryDetailChargerStatus | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.5 | INTEGER | read-only | The status of the battery charger. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryDetailCurrent | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.2 | Unsigned32 | read-only | The present battery current. |
| tlpUpsBatteryDetailEntry | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1 | not-accessible | An entry containing information applicable to a particular battery system managed by this agent. | |
| tlpUpsBatteryDetailTable | 1.3.6.1.4.1.850.1.1.3.1.3.1.2 | not-accessible | The battery detail of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| U32 tlpUpsBatteryDetailVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.1 | Unsigned32 | read-only | The magnitude of the present battery voltage. |
| U32 tlpUpsBatteryPackConfigBatteriesPerString | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.5 | Unsigned32 | read-only | The number of battery per each string in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| INT tlpUpsBatteryPackConfigCapacityUnits | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.8 | INTEGER | read-only | The units of measurement used for tlpUpsBatteryPackConfigDesignCapacity and tlpUpsBatteryPackConfigCellCapacity. If supported, this value will report either mAHR(1), amps per hour, or mWhr(1), watts per hour. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryPackConfigCellCapacity | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.10 | Unsigned32 | read-only | The capacity of the batteries in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| INT tlpUpsBatteryPackConfigCellsPerBattery | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.6 | INTEGER | read-only | The number of cells per battery.. |
| INT tlpUpsBatteryPackConfigChemistry | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.1 | INTEGER | read-only | The type of battery pack. |
| U32 tlpUpsBatteryPackConfigDesignCapacity | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.9 | Unsigned32 | read-only | The theoretical or nominal capacity of the battery pack in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| tlpUpsBatteryPackConfigEntry | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1 | not-accessible | An entry containing information applicable to a particular battery pack managed by this agent. | |
| INT tlpUpsBatteryPackConfigLocation | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.3 | INTEGER | read-only | The location of the battery pack. |
| U32 tlpUpsBatteryPackConfigMaxCellVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.12 | Unsigned32 | read-only | The maximum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryPackConfigMinCellVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.11 | Unsigned32 | read-only | The minimum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryPackConfigNumBatteries | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.7 | Unsigned32 | read-only | The total number of batteries contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryPackConfigStrings | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.4 | Unsigned32 | read-only | The number of series strings in parallel contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| INT tlpUpsBatteryPackConfigStyle | 1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.2 | INTEGER | read-only | The style of battery pack. |
| tlpUpsBatteryPackConfigTable | 1.3.6.1.4.1.850.1.1.3.1.3.1.4 | not-accessible | The battery configuration details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks. | |
| U32 tlpUpsBatteryPackDetailAge | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.4 | Unsigned32 | read-only | The age of the battery in years. This is equal to the current date minus tlpUpsBatteryPackIdentInstallDate. |
| INT tlpUpsBatteryPackDetailCondition | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.1 | INTEGER | read-only | The condition of the battery. A bad battery should be replaced. |
| U32 tlpUpsBatteryPackDetailCycleCount | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.7 | Unsigned32 | read-only | The number of times the battery went into invert mode. This number is incremented by 1 each time the unit goes on battery mode (with the exception of Self Test mode). If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME. |
| tlpUpsBatteryPackDetailEntry | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1 | not-accessible | An entry containing information applicable to a particular battery system managed by this agent. | |
| STR tlpUpsBatteryPackDetailLastReplaceDate | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.5 | DisplayString | read-write | The date when the batteries were last replaced in YYYYMMDD format. |
| STR tlpUpsBatteryPackDetailNextReplaceDate | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.6 | DisplayString | read-only | The date when the batteries should next be replaced in YYYYMMDD format. |
| tlpUpsBatteryPackDetailTable | 1.3.6.1.4.1.850.1.1.3.1.3.1.5 | not-accessible | The details of each battery pack for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss and battery packs managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumBatteryPacks. | |
| U32 tlpUpsBatteryPackDetailTemperatureC | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.2 | Unsigned32 | read-only | The ambient temperature at or near the UPS Battery casing. |
| U32 tlpUpsBatteryPackDetailTemperatureF | 1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.3 | Unsigned32 | read-only | The ambient temperature at or near the UPS Battery casing. |
| tlpUpsBatteryPackIdentEntry | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1 | not-accessible | An entry containing information applicable to a particular battery pack managed by this agent. | |
| STR tlpUpsBatteryPackIdentFirmware | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.5 | DisplayString | read-only | The firmware of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| U32 tlpUpsBatteryPackIdentIndex | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.1 | Unsigned32 | read-only | The table row index for the ups battery pack. |
| STR tlpUpsBatteryPackIdentManufacturer | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.2 | DisplayString | read-only | The manufacturer of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| STR tlpUpsBatteryPackIdentModel | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.3 | DisplayString | read-only | The model or device name of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| STR tlpUpsBatteryPackIdentSerialNum | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.4 | DisplayString | read-only | The serial number of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| STR tlpUpsBatteryPackIdentSKU | 1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.6 | DisplayString | read-only | The SKU of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| tlpUpsBatteryPackIdentTable | 1.3.6.1.4.1.850.1.1.3.1.3.1.3 | not-accessible | The battery identification details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks. | |
| TIK tlpUpsBatteryRunTimeRemaining | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.5 | TimeTicks | read-only | The run time remaining before batteries are exhausted. If the device does not support run time remaining, then the agent reports ERROR_NO_SUCH_NAME. |
| INT tlpUpsBatteryStatus | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.1 | INTEGER | read-only | The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than tlpUpsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to tlpUpsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output). |
| tlpUpsBatterySummaryEntry | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1 | not-accessible | An entry containing information applicable to a particular battery system managed by this agent. | |
| tlpUpsBatterySummaryTable | 1.3.6.1.4.1.850.1.1.3.1.3.1.1 | not-accessible | The battery system summary of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| tlpUpsBypass | 1.3.6.1.4.1.850.1.1.3.1.3.4 | |||
| tlpUpsBypassEntry | 1.3.6.1.4.1.850.1.1.3.1.3.4.1.1 | not-accessible | An entry containing information applicable to all input lines per each ups managed by this agent. | |
| U32 tlpUpsBypassFrequency | 1.3.6.1.4.1.850.1.1.3.1.3.4.1.1.1 | Unsigned32 | read-only | The present bypass frequency. |
| U32 tlpUpsBypassLineCurrent | 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.3 | Unsigned32 | read-only | The present bypass current. |
| tlpUpsBypassLineEntry | 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1 | not-accessible | An entry containing information applicable to a particular bypass line managed by this agent. | |
| U32 tlpUpsBypassLineIndex | 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.1 | Unsigned32 | read-only | The bypass line identifier. |
| U32 tlpUpsBypassLinePower | 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.4 | Unsigned32 | read-only | The present true power conveyed by the bypass. |
| tlpUpsBypassLineTable | 1.3.6.1.4.1.850.1.1.3.1.3.4.2 | not-accessible | The bypass line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| U32 tlpUpsBypassLineVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.2 | Unsigned32 | read-only | The present bypass voltage. |
| tlpUpsBypassTable | 1.3.6.1.4.1.850.1.1.3.1.3.4.1 | not-accessible | The bypass details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| tlpUpsConfig | 1.3.6.1.4.1.850.1.1.3.1.5 | |||
| INT tlpUpsConfigAudibleStatus | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.5 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self- describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect. |
| INT tlpUpsConfigAutoBatteryTest | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.6 | INTEGER | read-write | When disabled(0), the ups will not perform an automatic battery selftest. When set to another value, the ups will perform an automatic selftest in the approximate period defined by each respective enumerated value. This feature is generally not recommended. |
| INT tlpUpsConfigAutoRampOnTransition | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.8 | INTEGER | read-write | When enabled(1), the ups should perform its preconfigured ramp sequence when valid AC is restored while in battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsConfigAutoRestartAfterShutdown | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.7 | INTEGER | read-write | When enabled(1), the ups should autorestart after a shutdown from battery mode if valid AC is applied. When disabled(0), the ups should not autorestart when AC is restored and instead power up into standby mode. |
| INT tlpUpsConfigAutoRestartDelayedWakeup | 1.3.6.1.4.1.850.1.1.3.1.5.2.1.2 | INTEGER | read-write | If enabled(1) and power fails during a DelayBeforeStartup and line remains invalid after the timeout expires, the ups will be set to turn back on automatically. If disabled(0), the ups will turn back on and go to standby mode instead. |
| tlpUpsConfigAutoRestartEntry | 1.3.6.1.4.1.850.1.1.3.1.5.2.1 | not-accessible | An entry containing configurable automatic restart options for a particular ups. | |
| INT tlpUpsConfigAutoRestartInverterShutdown | 1.3.6.1.4.1.850.1.1.3.1.5.2.1.1 | INTEGER | read-write | If enabled(1) and the ups is turned off from invert mode (via user interaction), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead. |
| INT tlpUpsConfigAutoRestartLowVoltageCutoff | 1.3.6.1.4.1.850.1.1.3.1.5.2.1.3 | INTEGER | read-write | If enabled(1) and the ups is turned off from invert mode (via low voltage cutoff), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead. |
| INT tlpUpsConfigAutoRestartOverLoad | 1.3.6.1.4.1.850.1.1.3.1.5.2.1.4 | INTEGER | read-write | If enabled(1) and the ups is turned off from invert mode (via overload), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead. |
| INT tlpUpsConfigAutoRestartOverTemperature | 1.3.6.1.4.1.850.1.1.3.1.5.2.1.5 | INTEGER | read-write | If enabled(1) and the ups is turned off from invert mode (via over temperature), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead. |
| tlpUpsConfigAutoRestartTable | 1.3.6.1.4.1.850.1.1.3.1.5.2 | not-accessible | The configurable automatic restart options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss. | |
| INT tlpUpsConfigAutoShedOnTransition | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.9 | INTEGER | read-write | When enabled(1), the ups should perform its preconfigured shed sequence when valid AC is lost causing the ups to enter battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsConfigBatteryAgeThreshold | 1.3.6.1.4.1.850.1.1.3.1.5.3.1.1 | Unsigned32 | read-write | The number of months for a battery to be in service. The battery age alarm, tlpUpsAlarmBatteryAgeAboveThreshold, is triggered when the current date exceeds tlpUpsBatteryPackIdentInstallDate by tlpUpsConfigBatteryAgeThreshold months. |
| INT tlpUpsConfigBypassLowerLimitPercent | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.10 | INTEGER | read-write | The lowest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsConfigBypassLowerLimitVoltage | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.12 | Unsigned32 | read-write | The lowest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsConfigBypassUpperLimitPercent | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.11 | INTEGER | read-write | The highest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsConfigBypassUpperLimitVoltage | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.13 | Unsigned32 | read-write | The highest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsConfigColdStart | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.14 | INTEGER | read-write | This option enables or disables the ability to turn the ups on without AC supplied. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsConfigEconomicMode | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.15 | INTEGER | read-write | The configurable economic mode options for the ups. The online(0) mode is the default configuration of most upss, which is synonymous as having the economic mode disabled. The economy(1) mode is the typical configuration to run in economy mode, which is synonymous as having the economic mode enabled. Constant50Hz(2) is a power strategy, which fixes the output frequency at 50Hz. Constant60Hz(3) is a power stragegy, which fixes the output frequency at 60Hz. ConstantAuto(4) regulates the output frequency at nominal input frequency. AutoAdaptive(5) mode will cause the ups to automatically switch between online(0), maximum quality, and economy(1), maximum efficiency, to improve efficiency during stable utility periods and improve output regulation during unstable utility periods. Not all values are supported by all upss. Most upss, if supportive of economic mode, only supports online(0) and economy(1). If the ups does not support economic mode, then this value will always return ERROR_NO_SUCH_NAME. |
| tlpUpsConfigEntry | 1.3.6.1.4.1.850.1.1.3.1.5.1.1 | not-accessible | An entry containing information applicable to all input lines per each ups managed by this agent. | |
| INT tlpUpsConfigFaultAction | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.16 | INTEGER | read-write | Determines the action to take if the output needs to be shut down due to a fault condition, limited by the type of fault incurred. When configured for bypass(0), the ups will go to bypass on a fault condition. When configured for standby(1), the ups will go to standby mode on a fault condition. Either configuration will be valid as long as AC input is within normal line voltage and frequency limits when the fault condition occurs. If the line is outside these limits, the ups will turn off. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsConfigInputFrequency | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.2 | Unsigned32 | read-write | The nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. |
| U32 tlpUpsConfigInputVoltage | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.1 | Unsigned32 | read-write | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. |
| INT tlpUpsConfigLineSensitivity | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.18 | INTEGER | read-write | Adjusts the AC line voltage sensitivity setting. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsConfigLowBatteryThreshold | 1.3.6.1.4.1.850.1.1.3.1.5.3.1.2 | INTEGER | read-write | This value denotes the percentage of battery capacity remaining warning level. The low battery alarm, tlpUpsAlarmLowBattery, is triggered when tlpUpsEstimatedChargeRemaining drops below this value. |
| U32 tlpUpsConfigLowBatteryTime | 1.3.6.1.4.1.850.1.1.3.1.5.3.1.3 | Unsigned32 | read-write | The value in seconds of tlpUpsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected. |
| INT tlpUpsConfigOffMode | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.17 | INTEGER | read-write | This option governs what mode the ups should go into when AC input is available, but the load is either off or not battery backed up. If this setting is configured for bypass(1), the intention is that any time the ups would normally go into standby mode, it would instead go into bypass mode. Note that this setting does not dictate the mode for fault conditions, which is governed by tlpUpsConfigFaultAction. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsConfigOutputFrequency | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.4 | Unsigned32 | read-write | The nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request will be rejected and the agent will respond with an appropriate error message. |
| U32 tlpUpsConfigOutputVoltage | 1.3.6.1.4.1.850.1.1.3.1.5.1.1.3 | Unsigned32 | read-write | The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. |
| INT tlpUpsConfigOverLoadThreshold | 1.3.6.1.4.1.850.1.1.3.1.5.3.1.4 | INTEGER | read-write | This value denotes the percentage of load at which the overload condition occurs. The overload alarm, tlpUpsAlarmOutputOverload, is triggered when the percentage of output load exceeds this value. |
| tlpUpsConfigTable | 1.3.6.1.4.1.850.1.1.3.1.5.1 | not-accessible | The configuration details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| tlpUpsConfigThresholdEntry | 1.3.6.1.4.1.850.1.1.3.1.5.3.1 | not-accessible | An entry containing configurable threshold options for a particular ups. | |
| tlpUpsConfigThresholdTable | 1.3.6.1.4.1.850.1.1.3.1.5.3 | not-accessible | The configurable threshold options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss. | |
| tlpUpsControl | 1.3.6.1.4.1.850.1.1.3.1.4 | |||
| INT tlpUpsControlBypass | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.7 | INTEGER | read-write | This switches the ups in and out of bypass mode. This value returns the current bypass mode: disable(0) if the ups is not in bypass mode, enable(1) if the ups is in bypass mode. Set to disable(0) to exit bypass mode, or enable(1) to enter bypass mode. If switching bypass mode is not supported, this value will return ERROR_NO_SUCH_NAME. |
| tlpUpsControlEntry | 1.3.6.1.4.1.850.1.1.3.1.4.1.1 | not-accessible | An entry containing controls for a particular ups. | |
| T/F tlpUpsControlRamp | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.2 | TruthValue | read-write | Set to TRUE to initiate the pre-designated ramp sequence on the ups. |
| T/F tlpUpsControlSelfTest | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.1 | TruthValue | read-write | Set to TRUE to initiate a self test on the ups. |
| T/F tlpUpsControlShed | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.3 | TruthValue | read-write | Set to TRUE to initiate the pre-designated shed sequence on the ups. |
| tlpUpsControlTable | 1.3.6.1.4.1.850.1.1.3.1.4.1 | not-accessible | The actionable controls for each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. | |
| T/F tlpUpsControlUpsOff | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.5 | TruthValue | read-write | Set to TRUE to turn the ups off. |
| T/F tlpUpsControlUpsOn | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.4 | TruthValue | read-write | Set to TRUE to turn the ups on. |
| T/F tlpUpsControlUpsReboot | 1.3.6.1.4.1.850.1.1.3.1.4.1.1.6 | TruthValue | read-write | Set to TRUE to reboot the ups. |
| tlpUpsDetail | 1.3.6.1.4.1.850.1.1.3.1.3 | |||
| tlpUpsDevice | 1.3.6.1.4.1.850.1.1.3.1.2 | |||
| tlpUpsDeviceEntry | 1.3.6.1.4.1.850.1.1.3.1.2.1.1 | not-accessible | An entry containing device details for a particular ups. | |
| INT tlpUpsDeviceMainLoadCommand | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.3 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on. |
| T/F tlpUpsDeviceMainLoadControllable | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.2 | TruthValue | read-only | Indicates whether or not the main output is controllable, and whether the ups can be turned off and on. |
| INT tlpUpsDeviceMainLoadState | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.1 | INTEGER | read-only | The current state of the main output of the device. |
| I32 tlpUpsDevicePowerOnDelay | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.4 | Integer32 | read-write | The configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. |
| tlpUpsDeviceTable | 1.3.6.1.4.1.850.1.1.3.1.2.1 | not-accessible | The device details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. | |
| I32 tlpUpsDeviceTemperatureC | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.7 | Integer32 | read-only | The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpUpsDeviceTemperatureF | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.8 | Integer32 | read-only | The ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME. |
| STR tlpUpsDeviceTestDate | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.5 | DisplayString | read-only | The date of the last self-test run on the ups, in the format YYYY-MM-DD. |
| INT tlpUpsDeviceTestResultsStatus | 1.3.6.1.4.1.850.1.1.3.1.2.1.1.6 | INTEGER | read-only | The result of the last self-test run on the ups. |
| INT tlpUpsEstimatedChargeRemaining | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.4 | INTEGER | read-only | An estimate of the battery charge remaining expressed as a percent of full charge. |
| U32 tlpUpsEstimatedMinutesRemaining | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.3 | Unsigned32 | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. |
| tlpUpsIdent | 1.3.6.1.4.1.850.1.1.3.1.1 | |||
| tlpUpsIdentEntry | 1.3.6.1.4.1.850.1.1.3.1.1.2.1 | not-accessible | An entry containing details for a particular ups. | |
| U32 tlpUpsIdentNumBatteryPacks | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.7 | Unsigned32 | read-only | The number of battery packs, internal and external combined, supported by the ups. |
| U32 tlpUpsIdentNumBypass | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.3 | Unsigned32 | read-only | The number of bypass lines supported by the ups. |
| U32 tlpUpsIdentNumInputs | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.1 | Unsigned32 | read-only | The number of input lines supported by the ups. |
| U32 tlpUpsIdentNumOutletGroups | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.6 | Unsigned32 | read-only | The number of receptacle groups supported by the ups. |
| U32 tlpUpsIdentNumOutlets | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.5 | Unsigned32 | read-only | The number of receptacles supported by the ups. |
| U32 tlpUpsIdentNumOutputs | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.2 | Unsigned32 | read-only | The number of output lines supported by the ups. |
| U32 tlpUpsIdentNumPhases | 1.3.6.1.4.1.850.1.1.3.1.1.2.1.4 | Unsigned32 | read-only | The number of phases supported by the ups. |
| U32 tlpUpsIdentNumUps | 1.3.6.1.4.1.850.1.1.3.1.1.1 | Unsigned32 | read-only | The number of ups devices that this agent is currently managing. |
| tlpUpsIdentTable | 1.3.6.1.4.1.850.1.1.3.1.1.2 | not-accessible | The identity details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. | |
| tlpUpsInput | 1.3.6.1.4.1.850.1.1.3.1.3.2 | |||
| tlpUpsInputEntry | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1 | not-accessible | An entry containing information applicable to all input lines per each ups managed by this agent. | |
| U32 tlpUpsInputHighTransferVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.7 | Unsigned32 | read-only | The maximum line voltage allowed before the ups system transfers to battery backup. |
| U32 tlpUpsInputHighTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.8 | Unsigned32 | read-only | The lower boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpUpsInputHighTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.9 | Unsigned32 | read-only | The upper boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit. |
| INT tlpUpsInputLineBads | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.1 | INTEGER | read-only | A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. This value is not supported on all units. If the ups does not support this value, then the agent reports ERROR_NO_SUCH_NAME. |
| U32 tlpUpsInputLowTransferVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.4 | Unsigned32 | read-only | The minimum line voltage allowed before the ups system transfers to battery backup. |
| U32 tlpUpsInputLowTransferVoltageLowerBound | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.5 | Unsigned32 | read-only | The lower boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpUpsInputLowTransferVoltageUpperBound | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.6 | Unsigned32 | read-only | The upper boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit. |
| U32 tlpUpsInputNominalFrequency | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.3 | Unsigned32 | read-only | The nominal value of the input line frequency. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsInputNominalVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.2 | Unsigned32 | read-only | The nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. |
| U32 tlpUpsInputPhaseCurrent | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.6 | Unsigned32 | read-only | The magnitude of the present input current. |
| tlpUpsInputPhaseEntry | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1 | not-accessible | An entry containing information applicable to a particular input phase managed by this agent. | |
| U32 tlpUpsInputPhaseFrequency | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.2 | Unsigned32 | read-only | The present input frequency for a given input line. |
| U32 tlpUpsInputPhaseIndex | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.1 | Unsigned32 | read-only | The table row index for the ups input phase. |
| U32 tlpUpsInputPhasePower | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.7 | Unsigned32 | read-only | The magnitude of the present input true power. |
| tlpUpsInputPhaseTable | 1.3.6.1.4.1.850.1.1.3.1.3.2.2 | not-accessible | The input phase details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumPhases. | |
| U32 tlpUpsInputPhaseVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3 | Unsigned32 | read-only | The magnitude of the present input voltage for a given input line. |
| U32 tlpUpsInputPhaseVoltageMax | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.5 | Unsigned32 | read-write | The maximum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| U32 tlpUpsInputPhaseVoltageMin | 1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.4 | Unsigned32 | read-write | The minimum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values. |
| tlpUpsInputTable | 1.3.6.1.4.1.850.1.1.3.1.3.2.1 | not-accessible | The input details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| tlpUpsOutlet | 1.3.6.1.4.1.850.1.1.3.1.3.5 | |||
| INT tlpUpsOutletCommand | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on. |
| T/F tlpUpsOutletControllable | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.5 | TruthValue | read-only | Denotes whether this outlet is controllable. |
| U32 tlpUpsOutletCurrent | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.8 | Unsigned32 | read-only | The present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpUpsSupportsCurrentPower. |
| STR tlpUpsOutletDescription | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.3 | DisplayString | read-write | A user-definable string identifying the device(s) connected to the given outlet. |
| tlpUpsOutletEntry | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1 | not-accessible | An entry containing information applicable to a particular outlet managed by this agent. | |
| I32 tlpUpsOutletGroup | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.14 | Integer32 | read-write | The tlpUpsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped. |
| INT tlpUpsOutletGroupCommand | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.6 | INTEGER | read-write | Reading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on. |
| STR tlpUpsOutletGroupDescription | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.4 | DisplayString | read-write | A description for this outlet group. |
| tlpUpsOutletGroupEntry | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1 | not-accessible | An entry containing information applicable to a particular outlet group managed by this agent. | |
| U32 tlpUpsOutletGroupIndex | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.1 | Unsigned32 | read-only | The table row index for the ups outlet group. |
| STR tlpUpsOutletGroupName | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.3 | DisplayString | read-write | The name of this outlet group. |
| ROW tlpUpsOutletGroupRowStatus | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.2 | RowStatus | read-write | Row status for the tlpUpsOutletGroupTable |
| INT tlpUpsOutletGroupState | 1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.5 | INTEGER | read-only | The current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined. |
| tlpUpsOutletGroupTable | 1.3.6.1.4.1.850.1.1.3.1.3.5.2 | not-accessible | The receptacle grouping details of each ups in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpUpsIdentNumOutletGroups per each device. | |
| U32 tlpUpsOutletIndex | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.1 | Unsigned32 | read-only | The table row index for the ups outlet. |
| STR tlpUpsOutletName | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.2 | DisplayString | read-write | A user-definable string identifying the name of the outlet. |
| U32 tlpUpsOutletPower | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.9 | Unsigned32 | read-only | The output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpUpsSupportsCurrentPower. |
| INT tlpUpsOutletRampAction | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.10 | INTEGER | read-write | The ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpUpsOutletRampDelay | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.11 | Integer32 | read-write | The number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsOutletShedAction | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.12 | INTEGER | read-write | The shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| I32 tlpUpsOutletShedDelay | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.13 | Integer32 | read-write | The number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME. |
| INT tlpUpsOutletState | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.4 | INTEGER | read-only | The current state of the outlet. |
| tlpUpsOutletTable | 1.3.6.1.4.1.850.1.1.3.1.3.5.1 | not-accessible | The details of each ups outlet in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| U32 tlpUpsOutletVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.7 | Unsigned32 | read-only | The magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpUpsSupportsOutletVoltage. |
| tlpUpsOutput | 1.3.6.1.4.1.850.1.1.3.1.3.3 | |||
| tlpUpsOutputEntry | 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1 | not-accessible | An entry containing information applicable to a particular output line managed by this agent. | |
| U32 tlpUpsOutputFrequency | 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.3 | Unsigned32 | read-only | The present output frequency. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a common frequency is supported by the ups, then this frequency will contain the common frequency value. If not supported, the agent reports ERROR_NO_SUCH_NAME. |
| U32 tlpUpsOutputLineCurrent | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3 | Unsigned32 | read-only | The present output current. |
| tlpUpsOutputLineEntry | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1 | not-accessible | An entry containing information applicable to a particular output line managed by this agent. | |
| U32 tlpUpsOutputLineFrequency | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.6 | Unsigned32 | read-only | The present output frequency on this output line. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a per line frequency is supported by the ups, then this frequency value will reports the value of this line. If not supported, the agent reports ERROR_NO_SUCH_NAME. |
| U32 tlpUpsOutputLineIndex | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.1 | Unsigned32 | read-only | The table row index for the ups output line. |
| INT tlpUpsOutputLinePercentLoad | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.5 | INTEGER | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA. |
| U32 tlpUpsOutputLinePower | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4 | Unsigned32 | read-only | The present output true power. |
| tlpUpsOutputLineTable | 1.3.6.1.4.1.850.1.1.3.1.3.3.2 | not-accessible | The output line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| U32 tlpUpsOutputLineVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2 | Unsigned32 | read-only | The magnitude of the present output voltage for a given output line. |
| U32 tlpUpsOutputNominalVoltage | 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.2 | Unsigned32 | read-only | The nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME. |
| INT tlpUpsOutputSource | 1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker. |
| tlpUpsOutputTable | 1.3.6.1.4.1.850.1.1.3.1.3.3.1 | not-accessible | The output details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps. | |
| U32 tlpUpsSecondsOnBattery | 1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.2 | Unsigned32 | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power. |
| T/F tlpUpsSupportsEnergywise | 1.3.6.1.4.1.850.1.1.3.1.1.3.1.1 | TruthValue | read-only | Indicates whether the ups supports Cisco EnergyWise. |
| tlpUpsSupportsEntry | 1.3.6.1.4.1.850.1.1.3.1.1.3.1 | not-accessible | An entry containing supported details for a particular ups. | |
| T/F tlpUpsSupportsOutletCurrentPower | 1.3.6.1.4.1.850.1.1.3.1.1.3.1.4 | TruthValue | read-only | Indicates whether the ups reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletCurrent and tlpUpsOutletPower. |
| T/F tlpUpsSupportsOutletGroup | 1.3.6.1.4.1.850.1.1.3.1.1.3.1.3 | TruthValue | read-only | Indicates whether the ups supports outlet groups. |
| T/F tlpUpsSupportsOutletVoltage | 1.3.6.1.4.1.850.1.1.3.1.1.3.1.5 | TruthValue | read-only | Indicates whether the ups reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletVoltage. |
| T/F tlpUpsSupportsRampShed | 1.3.6.1.4.1.850.1.1.3.1.1.3.1.2 | TruthValue | read-only | Indicates whether the ups supports ramping and shedding. |
| tlpUpsSupportsTable | 1.3.6.1.4.1.850.1.1.3.1.1.3 | not-accessible | The supported details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. | |
| tlpUpsWatchdog | 1.3.6.1.4.1.850.1.1.3.1.3.6 | |||
| tlpUpsWatchdogEntry | 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1 | not-accessible | An entry containing watchdog details for a particular ups. | |
| U32 tlpUpsWatchdogSecsBeforeReboot | 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.2 | Unsigned32 | read-write | The maximum number of seconds that can expire between polls that the engine makes to the ups for data. If this time runs out, then the ups will cycle its outputs. Set this to zero to turns disable this feature. |
| T/F tlpUpsWatchdogSupported | 1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.1 | TruthValue | read-only | Indicates whether or not this ups supports a watchdog reboot. |
| tlpUpsWatchdogTable | 1.3.6.1.4.1.850.1.1.3.1.3.6.1 | not-accessible | The watchdog details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. |
RFC description
Tripp Lite UPS and PDU management MIB. Monitors power supply units, UPS status, power distribution, and environmental parameters on Tripp Lite devices.
Start monitoring Tripp Lite PowerAlert-managed devices, UPS and related equipment (device inventory/firmware-identity status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.