All MIBs › TRIPPLITE-MIB
Organization: Tripp Lite
Last Updated: 2013-10-30
Category: Tripp Lite Power Management, UPS and Power Management
Description: Monitors Tripp Lite UPS devices including battery charge, load levels, input/output voltage and alarms.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TRIPPLITE-MIB?
TRIPPLITE-MIB is a vendor MIB from Tripp Lite for remote management of its PowerAlert-managed UPS (uninterruptible power supply) devices and related software. It exposes UPS hardware status data including battery charge level, load percentage, input/output voltage, and alarm conditions, alongside configuration tables for email and SNMP notification contacts used for alerting. Its monitoring value is squarely hardware power-health monitoring: administrators use it to track battery state and load to anticipate runtime during outages, detect overload conditions, and confirm alarm/contact configuration is correctly set so that notifications reach the right recipients. It is a self-contained vendor MIB with its own enumerations (tlEnumerations) rather than depending heavily on external standard MIBs, though it parallels the general structure of the standard UPS-MIB. It is deployed wherever Tripp Lite UPS units protect servers, network gear, or data-center equipment and are polled or configured for alerting via SNMP-enabled network management cards. Engineers can download the TRIPPLITE-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TRIPPLITE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Tripp Lite UPS (uninterruptible power supply) with PowerAlert management
Monitoring Examples
An admin would poll UPS-level battery and load objects (paralleling the vendor's PowerAlert data model) to track battery charge percentage and load level, watching for a charge level trending toward a low threshold during a power event, which signals imminent shutdown risk. The tlPAEmailContactsTable/tlPAEmailContactEntry (tlPAEmailContactName, tlPAEmailContactAddress) and tlPASnmpContactsTable/tlPASnmpContactEntry would be checked to confirm the correct staff and SNMP trap destinations are configured to receive alarm notifications. A missing or misconfigured entry in these contact tables would explain why an alarm condition failed to reach the expected recipient.
What Can Be Monitored
- battery charge level
- UPS load percentage
- input/output voltage
- alarm/notification conditions
- configured email alert contacts
- configured SNMP alert contacts
This MIB depends on
Related MIBs
Imported Objects
From RFC-1215
| TRAP-TYPE |
From SNMPv2-CONF
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Gauge32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| enterprises |
From SNMPv2-TC
| AutonomousType | |
| DateAndTime | |
| DisplayString | |
| RowStatus | |
| TimeInterval | |
| TimeStamp | |
| TruthValue | |
| VariablePointer |
From UPS-MIB
| NonNegativeInteger | |
| PositiveInteger |
How to Use in IPNetwork Monitor
Example using tlUpsAlarmsPresent OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| tripplite | 1.3.6.1.4.1.850 | This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software. | ||
| trippUPS | 1.3.6.1.4.1.850.1 | |||
| tlV11TrapsPrefix | 1.3.6.1.4.1.850.1.0 | |||
| NTF tlV11upsCritical | 1.3.6.1.4.1.850.1.0.100 | UPS Critical Alarm. | ||
| NTF tlV11upsWarning | 1.3.6.1.4.1.850.1.0.101 | UPS Warning. | ||
| NTF tlV11upsInformation | 1.3.6.1.4.1.850.1.0.102 | UPS Information. | ||
| NTF tlV11upsAlarmCleared | 1.3.6.1.4.1.850.1.0.103 | UPS Alarm Cleared. | ||
| NTF tlV11upsAgentStarted | 1.3.6.1.4.1.850.1.0.104 | Agent started. | ||
| NTF tlV11upsAgentStopped | 1.3.6.1.4.1.850.1.0.105 | Agent stopped. | ||
| trippUpsReceptacles | 1.3.6.1.4.1.850.1.1 | |||
| NUM upsReceptaclesNumReceptacles | 1.3.6.1.4.1.850.1.1.1 | NonNegativeInteger | read-only | The number of available receptacles in this device. This variable indicates the number of rows in the receptacle table. |
| upsReceptacleTable | 1.3.6.1.4.1.850.1.1.2 | not-accessible | A list of receptacle table entries. The number of entries is given by the value of upsReceptaclesNumReceptacles. | |
| upsReceptacleEntry | 1.3.6.1.4.1.850.1.1.2.1 | not-accessible | An entry containing information applicable to a particular receptacle. | |
| NUM upsReceptacleIndex | 1.3.6.1.4.1.850.1.1.2.1.1 | PositiveInteger | read-only | The receptacle identifier. |
| INT upsReceptacleType | 1.3.6.1.4.1.850.1.1.2.1.2 | INTEGER | read-only | The type of receptacle. |
| INT upsReceptacleStatus | 1.3.6.1.4.1.850.1.1.2.1.3 | INTEGER | read-only | The status of receptacle. |
| INT upsReceptacleControl | 1.3.6.1.4.1.850.1.1.2.1.4 | INTEGER | read-write | Setting this object to 'on' will turn on the receptacle. Setting this object to 'off' will turn off the receptacle. Setting this object to 'cycle' will turn off and then turn on the receptacle. This action will only take place if the receptacle is controllable (upsReceptacleType = controllableBatteryProtected(3)). |
| trippUpsTrapInfo | 1.3.6.1.4.1.850.1.2 | |||
| INT upsTrapCode | 1.3.6.1.4.1.850.1.2.1 | INTEGER | read-only | A numeric code identifiying the condition that caused the trap to be sent. If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this code will indicate whether the SNMP agent is software (1) or hardware (2). |
| STR upsTrapDescription | 1.3.6.1.4.1.850.1.2.2 | DisplayString | read-only | The description of the trap. |
| trippUpsEnvironment | 1.3.6.1.4.1.850.1.3 | |||
| I32 upsEnvTemperature | 1.3.6.1.4.1.850.1.3.1 | Integer32 | read-only | The ambient temperature of the EnviroSense unit (1/10 Deg C). |
| INT upsEnvHumidity | 1.3.6.1.4.1.850.1.3.2 | INTEGER | read-only | The ambient humidity of the EnviroSense unit (% Humidity). |
| trippUpsContacts | 1.3.6.1.4.1.850.1.4 | |||
| upsContactTable | 1.3.6.1.4.1.850.1.4.1 | not-accessible | A table of contacts attached to the EnviroSense unit. | |
| upsContactEntry | 1.3.6.1.4.1.850.1.4.1.1 | not-accessible | An entry containing information applicable to a particular contact. | |
| NUM upsContactIndex | 1.3.6.1.4.1.850.1.4.1.1.1 | PositiveInteger | read-only | The contact identifier. |
| STR upsContactName | 1.3.6.1.4.1.850.1.4.1.1.2 | DisplayString | read-write | The contact name. |
| INT upsContactStatus | 1.3.6.1.4.1.850.1.4.1.1.3 | INTEGER | read-only | The current status of the contact. |
| INT upsContactConfig | 1.3.6.1.4.1.850.1.4.1.1.4 | INTEGER | read-write | The default configuration of the contact. |
| tlEnumerations | 1.3.6.1.4.1.850.2 | |||
| tlOperatingSystems | 1.3.6.1.4.1.850.2.1 | |||
| hpux9 | 1.3.6.1.4.1.850.2.1.1 | |||
| sunos4 | 1.3.6.1.4.1.850.2.1.2 | |||
| solaris | 1.3.6.1.4.1.850.2.1.3 | |||
| osf | 1.3.6.1.4.1.850.2.1.4 | |||
| ultrix | 1.3.6.1.4.1.850.2.1.5 | |||
| hpux10 | 1.3.6.1.4.1.850.2.1.6 | |||
| netbsd1 | 1.3.6.1.4.1.850.2.1.7 | |||
| freebsd | 1.3.6.1.4.1.850.2.1.8 | |||
| irix | 1.3.6.1.4.1.850.2.1.9 | |||
| linux | 1.3.6.1.4.1.850.2.1.10 | |||
| bsdi | 1.3.6.1.4.1.850.2.1.11 | |||
| openbsd | 1.3.6.1.4.1.850.2.1.12 | |||
| win32 | 1.3.6.1.4.1.850.2.1.13 | |||
| hpux11 | 1.3.6.1.4.1.850.2.1.14 | |||
| win9x | 1.3.6.1.4.1.850.2.1.50 | |||
| winnt | 1.3.6.1.4.1.850.2.1.51 | |||
| solspark | 1.3.6.1.4.1.850.2.1.52 | |||
| solintel | 1.3.6.1.4.1.850.2.1.53 | |||
| aix | 1.3.6.1.4.1.850.2.1.54 | |||
| sco | 1.3.6.1.4.1.850.2.1.55 | |||
| osx | 1.3.6.1.4.1.850.2.1.56 | |||
| unknown | 1.3.6.1.4.1.850.2.1.255 | |||
| tlConformance | 1.3.6.1.4.1.850.20 | |||
| tlCompliances | 1.3.6.1.4.1.850.20.1 | |||
| tlGroups | 1.3.6.1.4.1.850.20.2 | |||
| tlSubsetGroups | 1.3.6.1.4.1.850.20.2.1 | |||
| tlBasicGroups | 1.3.6.1.4.1.850.20.2.2 | |||
| tlFullGroups | 1.3.6.1.4.1.850.20.2.3 | |||
| tlUpsFullGroups | 1.3.6.1.4.1.850.20.2.3.100 | |||
| tlUpsFullIdentGroup | 1.3.6.1.4.1.850.20.2.3.100.1 | The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's | ||
| tlUpsFullBatteryGroup | 1.3.6.1.4.1.850.20.2.3.100.2 | The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's | ||
| tlUpsFullAlarmGroup | 1.3.6.1.4.1.850.20.2.3.100.6 | |||
| tlUpsFullAlarmObjsGroup | 1.3.6.1.4.1.850.20.2.3.100.6.1 | The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's | ||
| tlUpsFullTestGroup | 1.3.6.1.4.1.850.20.2.3.100.7 | The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's | ||
| tlUpsFullControlGroup | 1.3.6.1.4.1.850.20.2.3.100.8 | The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's | ||
| tlUpsFullConfigGroup | 1.3.6.1.4.1.850.20.2.3.100.9 | The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's | ||
| tlUpsFullOutletGroup | 1.3.6.1.4.1.850.20.2.3.100.10 | The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's | ||
| tlV11Groups | 1.3.6.1.4.1.850.20.2.4 | |||
| tlDeprecatedV11Group | 1.3.6.1.4.1.850.20.2.4.1 | The tlDeprecatedV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11. These objects are currently only used when tlEngineLegacySNMPSupport == true. | ||
| tlDeprecatedV11NotificationsGroup | 1.3.6.1.4.1.850.20.2.4.2 | The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11 notifications. These notifications are being deprecated, but may still be used when tlEngineLegacySNMPSupport = true. | ||
| tlObsoleteV11Group | 1.3.6.1.4.1.850.20.2.4.3 | The tlObsoleteV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete. | ||
| tlPowerAlert | 1.3.6.1.4.1.850.90 | |||
| tlPASystem | 1.3.6.1.4.1.850.90.1 | |||
| tlPAContacts | 1.3.6.1.4.1.850.90.1.1 | |||
| tlPAEmailContacts | 1.3.6.1.4.1.850.90.1.1.1 | |||
| NUM tlPANumberOfEmailContacts | 1.3.6.1.4.1.850.90.1.1.1.1 | NonNegativeInteger | read-only | The number email contacts currently defined. |
| tlPAEmailContactsTable | 1.3.6.1.4.1.850.90.1.1.1.2 | not-accessible | A list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts. | |
| tlPAEmailContactEntry | 1.3.6.1.4.1.850.90.1.1.1.2.1 | not-accessible | An entry containing email contacts information. | |
| NUM tlPAEmailContactIndex | 1.3.6.1.4.1.850.90.1.1.1.2.1.1 | PositiveInteger | read-only | This is the index number of the email contact. |
| ROW tlPAEmailContactRowStatus | 1.3.6.1.4.1.850.90.1.1.1.2.1.2 | RowStatus | read-write | The row status for the tlPAEmailContactTable row |
| STR tlPAEmailContactName | 1.3.6.1.4.1.850.90.1.1.1.2.1.3 | DisplayString | read-write | The name of the email contact. |
| STR tlPAEmailContactAddress | 1.3.6.1.4.1.850.90.1.1.1.2.1.4 | DisplayString | read-write | The address of the email contact. |
| tlPASnmpContacts | 1.3.6.1.4.1.850.90.1.1.2 | |||
| NUM tlPANumberOfSnmpContacts | 1.3.6.1.4.1.850.90.1.1.2.1 | NonNegativeInteger | read-only | The number SNMP contacts currently defined. |
| tlPASnmpContactsTable | 1.3.6.1.4.1.850.90.1.1.2.2 | not-accessible | A list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts. | |
| tlPASnmpContactEntry | 1.3.6.1.4.1.850.90.1.1.2.2.1 | not-accessible | An entry containing SNMP contacts information. | |
| NUM tlPASnmpContactIndex | 1.3.6.1.4.1.850.90.1.1.2.2.1.1 | PositiveInteger | read-only | This is the index number of this SNMP contact. |
| ROW tlPASnmpContactRowStatus | 1.3.6.1.4.1.850.90.1.1.2.2.1.2 | RowStatus | read-write | The row status for the tlPASnmpContactTable row |
| STR tlPASnmpContactName | 1.3.6.1.4.1.850.90.1.1.2.2.1.3 | DisplayString | read-write | The name of the SNMP contact. |
| STR tlPASnmpContactIpAddress | 1.3.6.1.4.1.850.90.1.1.2.2.1.4 | DisplayString | read-write | The IP address of the SNMP contact. |
| NUM tlPASnmpContactPort | 1.3.6.1.4.1.850.90.1.1.2.2.1.5 | PositiveInteger | read-write | The port of the SNMP contact. |
| INT tlPASnmpContactSnmpVersion | 1.3.6.1.4.1.850.90.1.1.2.2.1.6 | INTEGER | read-write | The SNMP contact version to use for sending traps. |
| STR tlPASnmpContactSecurityName | 1.3.6.1.4.1.850.90.1.1.2.2.1.7 | DisplayString | read-write | The SNMP contact security name. |
| STR tlPASnmpContactPrivPassword | 1.3.6.1.4.1.850.90.1.1.2.2.1.8 | DisplayString | read-write | The SNMP contact priv password to use for sending V3 traps. |
| STR tlPASnmpContactAuthPassword | 1.3.6.1.4.1.850.90.1.1.2.2.1.9 | DisplayString | read-write | The SNMP contact auth password to use for sending V3 traps. |
| tlUPS | 1.3.6.1.4.1.850.100 | |||
| tlUpsObjects | 1.3.6.1.4.1.850.100.1 | |||
| tlUpsIdent | 1.3.6.1.4.1.850.100.1.1 | |||
| I32 tlUpsIdentUpsSoftwareChecksum | 1.3.6.1.4.1.850.100.1.1.1 | Integer32 | read-only | A checksum for the UPS software. |
| STR tlUpsIdentSerialNum | 1.3.6.1.4.1.850.100.1.1.2 | DisplayString | read-only | Serial number for the UPS. |
| I32 tlUpsIdentID | 1.3.6.1.4.1.850.100.1.1.3 | Integer32 | read-write | A user-supplied ID for the UPS. |
| STR tlUpsSnmpCardSerialNum | 1.3.6.1.4.1.850.100.1.1.4 | DisplayString | read-only | Serial number for the UPS. |
| I32 tlUpsSelectedDeviceID | 1.3.6.1.4.1.850.100.1.1.5 | Integer32 | read-write | The device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for it |
| STR tlUpsLocation | 1.3.6.1.4.1.850.100.1.1.6 | DisplayString | read-write | The device location string. |
| tlUpsBattery | 1.3.6.1.4.1.850.100.1.2 | |||
| STR tlUpsBatteryAge | 1.3.6.1.4.1.850.100.1.2.1 | DisplayString | read-only | The age of the battery in years. This is equal to the current date minus tlConfigBattReplDate. |
| I32 tlUpsTemperatureF | 1.3.6.1.4.1.850.100.1.2.2 | Integer32 | read-only | The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees. |
| tlUpsInput | 1.3.6.1.4.1.850.100.1.3 | |||
| NUM tlUpsInputNumVoltages | 1.3.6.1.4.1.850.100.1.3.1 | NonNegativeInteger | read-only | The number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table. |
| tlUpsInputVoltageTable | 1.3.6.1.4.1.850.100.1.3.2 | not-accessible | A list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages. | |
| tlUpsInputVoltageEntry | 1.3.6.1.4.1.850.100.1.3.2.1 | not-accessible | An entry containing information applicable to a particular input voltage. | |
| NUM tlUpsInputVoltageIndex | 1.3.6.1.4.1.850.100.1.3.2.1.1 | PositiveInteger | not-accessible | The input voltage identifier. |
| INT tlUpsInputVoltageType | 1.3.6.1.4.1.850.100.1.3.2.1.2 | INTEGER | read-only | Whether voltage measured is phase to phase or phase to neutral. |
| NUM tlUpsInputVoltage | 1.3.6.1.4.1.850.100.1.3.2.1.3 | NonNegativeInteger | read-only | The magnitude of the present input voltage. A value of 6553 indicates Unknown. |
| tlUpsOutput | 1.3.6.1.4.1.850.100.1.4 | |||
| NUM tlUpsOutputPowerTotal | 1.3.6.1.4.1.850.100.1.4.5 | PositiveInteger | read-only | The power capacity of the device. |
| NUM tlUpsOutputCircuits | 1.3.6.1.4.1.850.100.1.4.6 | NonNegativeInteger | read-only | The number of output circuits. This variable indicates the number of rows in the output circuit table. |
| tlUpsOutputCircuitTable | 1.3.6.1.4.1.850.100.1.4.7 | not-accessible | A list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits. | |
| tlUpsOutputCircuitEntry | 1.3.6.1.4.1.850.100.1.4.7.1 | not-accessible | An entry containing information applicable to a particular output circuit. | |
| NUM tlUpsOutputCircuitIndex | 1.3.6.1.4.1.850.100.1.4.7.1.1 | PositiveInteger | not-accessible | The output circuit identifier. |
| INT tlUpsOutputCircuitStatus | 1.3.6.1.4.1.850.100.1.4.7.1.2 | INTEGER | read-only | Whether the breaker is open or closed. |
| NUM tlUpsOutputCircuitLoadCurrent | 1.3.6.1.4.1.850.100.1.4.7.1.3 | NonNegativeInteger | read-only | The magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown. |
| tlUpsAlarm | 1.3.6.1.4.1.850.100.1.6 | |||
| G32 tlUpsAlarmsPresentEx | 1.3.6.1.4.1.850.100.1.6.1 | Gauge32 | read-only | The present number of active alarm conditions. |
| tlUpsAlarmTable | 1.3.6.1.4.1.850.100.1.6.2 | not-accessible | A list of alarm table entries. | |
| tlUpsAlarmEntry | 1.3.6.1.4.1.850.100.1.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm. | |
| NUM tlUpsAlarmId | 1.3.6.1.4.1.850.100.1.6.2.1.1 | PositiveInteger | read-only | A unique identifier for an alarm condition. |
| OID tlUpsAlarmDescr | 1.3.6.1.4.1.850.100.1.6.2.1.2 | AutonomousType | read-only | A description of the alarm condition. |
| TIM tlUpsAlarmTime | 1.3.6.1.4.1.850.100.1.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. |
| STR tlUpsAlarmDetail | 1.3.6.1.4.1.850.100.1.6.2.1.4 | DisplayString | read-only | A textual description of the alarm condition. |
| NUM tlUpsAlarmDeviceId | 1.3.6.1.4.1.850.100.1.6.2.1.5 | PositiveInteger | read-only | A numeric identifier for the device on which the alarm is active. |
| STR tlUpsAlarmDeviceName | 1.3.6.1.4.1.850.100.1.6.2.1.6 | DisplayString | read-only | A string identifier for the device on which the alarm is active. |
| STR tlUpsAlarmLocation | 1.3.6.1.4.1.850.100.1.6.2.1.7 | DisplayString | read-only | The location of the device on which the alarm is active. |
| INT tlUpsAlarmGroup | 1.3.6.1.4.1.850.100.1.6.2.1.8 | INTEGER | read-only | The category/group of this alarm. |
| IP tlUpsAlarmIp | 1.3.6.1.4.1.850.100.1.6.2.1.9 | IpAddress | read-only | The originating IP address associated with this alarm. |
| STR tlUpsAlarmMac | 1.3.6.1.4.1.850.100.1.6.2.1.10 | DisplayString | read-only | The originating mac address associated with this alarm. |
| tlUpsWellKnownAlarms | 1.3.6.1.4.1.850.100.1.6.3 | |||
| tlUpsAlarmPrimaryPowerOutage | 1.3.6.1.4.1.850.100.1.6.3.1 | The primary power source is not present. | ||
| tlUpsAlarmSecondaryPowerOutage | 1.3.6.1.4.1.850.100.1.6.3.2 | The secondary power source is not present. | ||
| tlUpsAlarmLoadLevelAboveThreshold | 1.3.6.1.4.1.850.100.1.6.3.3 | The load level is above the designated threshold. | ||
| tlUpsAlarmOutputCurrentChanged | 1.3.6.1.4.1.850.100.1.6.3.4 | The output current changed from its last known value. | ||
| tlUpsAlarmBatteryAgeAboveThreshold | 1.3.6.1.4.1.850.100.1.6.3.5 | One or more batteries have been determined to require replacement. | ||
| tlUpsAlarmLoadOff | 1.3.6.1.4.1.850.100.1.6.3.6 | The load is off. | ||
| tlUpsAlarmUserDefined | 1.3.6.1.4.1.850.100.1.6.3.7 | A user-defined event is in alarm. | ||
| tlUpsAlarmBatteryBad | 1.3.6.1.4.1.850.100.1.6.3.8 | One or more batteries have been determined to require replacement. | ||
| tlUpsAlarmOnBattery | 1.3.6.1.4.1.850.100.1.6.3.9 | The UPS is drawing power from the batteries. | ||
| tlUpsAlarmLowBattery | 1.3.6.1.4.1.850.100.1.6.3.10 | The remaining battery run-time is less than or equal to upsConfigLowBattTime. | ||
| tlUpsAlarmDepletedBattery | 1.3.6.1.4.1.850.100.1.6.3.11 | The UPS will be unable to sustain the present load when and if the utility power is lost. | ||
| tlUpsAlarmTempBad | 1.3.6.1.4.1.850.100.1.6.3.12 | A temperature is out of tolerance. | ||
| tlUpsAlarmInputBad | 1.3.6.1.4.1.850.100.1.6.3.13 | An input condition is out of tolerance. | ||
| tlUpsAlarmOutputBad | 1.3.6.1.4.1.850.100.1.6.3.14 | An output condition (other than OutputOverload) is out of tolerance. | ||
| tlUpsAlarmOutputOverload | 1.3.6.1.4.1.850.100.1.6.3.15 | The output load exceeds the UPS output capacity. | ||
| tlUpsAlarmOnBypass | 1.3.6.1.4.1.850.100.1.6.3.16 | The Bypass is presently engaged on the UPS. | ||
| tlUpsAlarmBypassBad | 1.3.6.1.4.1.850.100.1.6.3.17 | The Bypass is out of tolerance. | ||
| tlUpsAlarmOutputOffAsRequested | 1.3.6.1.4.1.850.100.1.6.3.18 | The UPS has shutdown as requested, i.e., the output is off. | ||
| tlUpsAlarmUpsOffAsRequested | 1.3.6.1.4.1.850.100.1.6.3.19 | The entire UPS has shutdown as commanded. | ||
| tlUpsAlarmChargerFailed | 1.3.6.1.4.1.850.100.1.6.3.20 | An uncorrected problem has been detected within the UPS charger subsystem. | ||
| tlUpsAlarmUpsOutputOff | 1.3.6.1.4.1.850.100.1.6.3.21 | The output of the UPS is in the off state. | ||
| tlUpsAlarmUpsSystemOff | 1.3.6.1.4.1.850.100.1.6.3.22 | The UPS system is in the off state. | ||
| tlUpsAlarmFanFailure | 1.3.6.1.4.1.850.100.1.6.3.23 | The failure of one or more fans in the UPS has been detected. | ||
| tlUpsAlarmFuseFailure | 1.3.6.1.4.1.850.100.1.6.3.24 | The failure of one or more fuses has been detected. | ||
| tlUpsAlarmGeneralFault | 1.3.6.1.4.1.850.100.1.6.3.25 | A general fault in the UPS has been detected. | ||
| tlUpsAlarmDiagnosticTestFailed | 1.3.6.1.4.1.850.100.1.6.3.26 | The result of the last diagnostic test indicates a failure. | ||
| tlUpsAlarmCommunicationsLost | 1.3.6.1.4.1.850.100.1.6.3.27 | A problem has been encountered in the communications between the agent and the UPS. | ||
| tlUpsAlarmAwaitingPower | 1.3.6.1.4.1.850.100.1.6.3.28 | The UPS output is off and the UPS is awaiting the return of input power. | ||
| tlUpsAlarmShutdownPending | 1.3.6.1.4.1.850.100.1.6.3.29 | A upsShutdownAfterDelay countdown is underway. | ||
| tlUpsAlarmShutdownImminent | 1.3.6.1.4.1.850.100.1.6.3.30 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. | ||
| tlUpsAlarmTestInProgress | 1.3.6.1.4.1.850.100.1.6.3.31 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. | ||
| tlUpsAlarmCircuitBreaker1Open | 1.3.6.1.4.1.850.100.1.6.3.32 | Circuit breakers #1 is open. | ||
| tlUpsAlarmCircuitBreaker2Open | 1.3.6.1.4.1.850.100.1.6.3.33 | Circuit breakers #2 is open. | ||
| tlUpsAlarmCircuitBreaker3Open | 1.3.6.1.4.1.850.100.1.6.3.34 | Circuit breakers #3 is open. | ||
| tlUpsAlarmCircuitBreaker4Open | 1.3.6.1.4.1.850.100.1.6.3.35 | Circuit breakers #4 is open. | ||
| tlUpsAlarmCircuitBreaker5Open | 1.3.6.1.4.1.850.100.1.6.3.36 | Circuit breakers #5 is open. | ||
| tlUpsAlarmCircuitBreaker6Open | 1.3.6.1.4.1.850.100.1.6.3.37 | Circuit breakers #6 is open. | ||
| tlUpsAlarmCircuitBreaker7Open | 1.3.6.1.4.1.850.100.1.6.3.38 | Circuit breakers #7 is open. | ||
| tlUpsAlarmCircuitBreaker8Open | 1.3.6.1.4.1.850.100.1.6.3.39 | Circuit breakers #8 is open. | ||
| tlUpsAlarmCurrent1AboveThreshold | 1.3.6.1.4.1.850.100.1.6.3.40 | The output current on line 1 exceeds load limits. | ||
| tlUpsAlarmCurrent2AboveThreshold | 1.3.6.1.4.1.850.100.1.6.3.41 | The output current on line 2 exceeds load limits. | ||
| tlUpsAlarmCurrent3AboveThreshold | 1.3.6.1.4.1.850.100.1.6.3.42 | The output current on line 3 exceeds load limits. | ||
| STR tlUpsAlarmDevName | 1.3.6.1.4.1.850.100.1.6.7 | DisplayString | read-only | The name of the device, tlDevName, corresponding to the device that is associated with this alarm. |
| STR tlUpsAlarmDevLocation | 1.3.6.1.4.1.850.100.1.6.8 | DisplayString | read-only | The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm. |
| I32 tlUpsAlarmCategory | 1.3.6.1.4.1.850.100.1.6.9 | Integer32 | read-only | The category, tlDevEvtCategory, of this alarm. |
| tlUpsTest | 1.3.6.1.4.1.850.100.1.7 | |||
| STR tlUpsTestDate | 1.3.6.1.4.1.850.100.1.7.1 | DisplayString | read-only | The date of the last self-test run on the ups, in the format YYYYMMDD. |
| STR tlUpsTestResultsDetail | 1.3.6.1.4.1.850.100.1.7.2 | DisplayString | read-only | Result of the last self-test run on the ups. |
| tlUpsControl | 1.3.6.1.4.1.850.100.1.8 | |||
| T/F tlUpsWatchdogSupported | 1.3.6.1.4.1.850.100.1.8.1 | TruthValue | read-only | Indicates whether or not this UPS supports a watchdog reboot. |
| NUM tlUpsWatchdogSecsBeforeReboot | 1.3.6.1.4.1.850.100.1.8.2 | NonNegativeInteger | read-write | The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature. |
| tlUpsWellKnownControls | 1.3.6.1.4.1.850.100.1.8.3 | |||
| T/F tlUpsControlSelfTest | 1.3.6.1.4.1.850.100.1.8.3.1 | TruthValue | read-write | Set to TRUE to initiate Self Test |
| T/F tlUpsControlRamp | 1.3.6.1.4.1.850.100.1.8.3.2 | TruthValue | read-write | Set to TRUE to initiate Ramp |
| T/F tlUpsControlShed | 1.3.6.1.4.1.850.100.1.8.3.3 | TruthValue | read-write | Set to TRUE to initiate Shed |
| T/F tlUpsControlUpsOn | 1.3.6.1.4.1.850.100.1.8.3.4 | TruthValue | read-write | Set to TRUE to turn UPS on |
| T/F tlUpsControlUpsOff | 1.3.6.1.4.1.850.100.1.8.3.5 | TruthValue | read-write | Set to TRUE to turn UPS off |
| tlUpsConfig | 1.3.6.1.4.1.850.100.1.9 | |||
| STR tlUpsConfigBattReplDate | 1.3.6.1.4.1.850.100.1.9.1 | DisplayString | read-write | The date on which the battery was last replaced, in the format YYYYMMDD. |
| tlUpsOutlet | 1.3.6.1.4.1.850.100.1.10 | |||
| NUM tlUpsOutletNumOutlets | 1.3.6.1.4.1.850.100.1.10.1 | NonNegativeInteger | read-only | The number of available Outlets in this device. |
| tlUpsOutletTable | 1.3.6.1.4.1.850.100.1.10.2 | not-accessible | A list of all device Outlets for all devices. | |
| tlUpsOutletEntry | 1.3.6.1.4.1.850.100.1.10.2.1 | not-accessible | An entry containing Outlet information applicable to a particular device managed by this agent. | |
| NUM tlUpsOutletIndex | 1.3.6.1.4.1.850.100.1.10.2.1.1 | PositiveInteger | read-only | This is the index number of this Outlet for the device indicated by tlDeviceIndex. |
| INT tlUpsOutletState | 1.3.6.1.4.1.850.100.1.10.2.1.2 | INTEGER | read-only | The current state of the Outlet. |
| I32 tlUpsOutletType | 1.3.6.1.4.1.850.100.1.10.2.1.3 | Integer32 | read-only | This is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15 |
| INT tlUpsOutletControl | 1.3.6.1.4.1.850.100.1.10.2.1.4 | INTEGER | read-write | Controls the state of the Outlet. |
| STR tlUpsOutletName | 1.3.6.1.4.1.850.100.1.10.2.1.5 | DisplayString | read-write | A string identifying the devices attached to the output(s) of the device. |
| INT tlUpsOutletRampAction | 1.3.6.1.4.1.850.100.1.10.2.1.6 | INTEGER | read-write | The ramp action to take on the Outlet. |
| INT tlUpsOutletRampDataType | 1.3.6.1.4.1.850.100.1.10.2.1.7 | INTEGER | read-write | The type of data associated with ramp action. |
| I32 tlUpsOutletRampData | 1.3.6.1.4.1.850.100.1.10.2.1.8 | Integer32 | read-write | The data value associated with type of ramp data. |
| INT tlUpsOutletShedAction | 1.3.6.1.4.1.850.100.1.10.2.1.9 | INTEGER | read-write | The shed action to take on the Outlet. |
| INT tlUpsOutletShedDataType | 1.3.6.1.4.1.850.100.1.10.2.1.10 | INTEGER | read-write | The type of data associated with shed action. |
| I32 tlUpsOutletShedData | 1.3.6.1.4.1.850.100.1.10.2.1.11 | Integer32 | read-write | The data value associated with type of shed data. |
| I32 tlUpsOutletGroupNdx | 1.3.6.1.4.1.850.100.1.10.2.1.12 | Integer32 | read-write | tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped. |
| NUM tlUpsOutletCurrent | 1.3.6.1.4.1.850.100.1.10.2.1.13 | PositiveInteger | read-only | The value of this outlet's current, represented as 0.1A. |
| NUM tlUpsOutletPower | 1.3.6.1.4.1.850.100.1.10.2.1.14 | PositiveInteger | read-only | The value of this outlet's power in watts. |
| tlUpsOutletGroup | 1.3.6.1.4.1.850.100.1.11 | |||
| NUM tlUpsOutletNumOutletGroups | 1.3.6.1.4.1.850.100.1.11.1 | NonNegativeInteger | read-only | The number of available Outlet Groups in this device. |
| tlUpsOutletGroupTable | 1.3.6.1.4.1.850.100.1.11.2 | not-accessible | A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups. | |
| tlUpsOutletGroupEntry | 1.3.6.1.4.1.850.100.1.11.2.1 | not-accessible | An entry containing outlet group information applicable to a particular device managed by this agent | |
| NUM tlUpsOutletGroupIndex | 1.3.6.1.4.1.850.100.1.11.2.1.1 | PositiveInteger | read-only | This is the index number of this load group for the device. |
| ROW tlUpsOutletGroupRowStatus | 1.3.6.1.4.1.850.100.1.11.2.1.2 | RowStatus | read-write | Row status for the tlUpsOutletGroupTable |
| STR tlUpsOutletGroupName | 1.3.6.1.4.1.850.100.1.11.2.1.3 | DisplayString | read-write | The name of this outlet group. |
| STR tlUpsOutletGroupDesc | 1.3.6.1.4.1.850.100.1.11.2.1.4 | DisplayString | read-write | A description for this outlet group. |
| INT tlUpsOutletGroupState | 1.3.6.1.4.1.850.100.1.11.2.1.5 | INTEGER | read-only | The current state of the outlet group. |
| INT tlUpsOutletGroupControl | 1.3.6.1.4.1.850.100.1.11.2.1.6 | INTEGER | read-write | Controls the state of every outlet associated with the group. |
| tlUpsMainOutlet | 1.3.6.1.4.1.850.100.1.12 | |||
| INT tlUpsMainOutletState | 1.3.6.1.4.1.850.100.1.12.1 | INTEGER | read-only | The current state of the main output of the device. |
| T/F tlUpsMainOutletControllable | 1.3.6.1.4.1.850.100.1.12.2 | TruthValue | read-only | Indicates if this device has controllable outlets |
| INT tlUpsMainOutletControl | 1.3.6.1.4.1.850.100.1.12.3 | INTEGER | read-write | Controls the state of the main outlet of the device. |
| tlUpsTraps | 1.3.6.1.4.1.850.100.2 | |||
| NTF tlUpsTrapAlarmEntryAddedV1 | 1.3.6.1.4.1.850.100.2.0.3 | This trap is sent each time an alarm is inserted into to the alarm table. | ||
| NTF tlUpsTrapAlarmEntryRemovedV1 | 1.3.6.1.4.1.850.100.2.0.4 | This trap is sent each time an alarm is removed from the alarm table. | ||
| NTF tlUpsTrapAlarmEntryAdded | 1.3.6.1.4.1.850.100.2.3 | This trap is sent each time an alarm is inserted into to the alarm table. | ||
| NTF tlUpsTrapAlarmEntryRemoved | 1.3.6.1.4.1.850.100.2.4 | This trap is sent each time an alarm is removed from the alarm table. | ||
| NTF tlUpsTrapSystemStartup | 1.3.6.1.4.1.850.100.2.5 | Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) | ||
| NTF tlUpsTrapSystemShutdown | 1.3.6.1.4.1.850.100.2.6 | Used to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) | ||
| tlEnviroSense | 1.3.6.1.4.1.850.101 | |||
| tlEnvEnvironment | 1.3.6.1.4.1.850.101.1 | |||
| tlEnvTemperatureData | 1.3.6.1.4.1.850.101.1.1 | |||
| I32 tlEnvTemperatureC | 1.3.6.1.4.1.850.101.1.1.1 | Integer32 | read-only | The ambient temperature (C). |
| I32 tlEnvTemperatureF | 1.3.6.1.4.1.850.101.1.1.2 | Integer32 | read-only | The ambient temperature (F). |
| I32 tlEnvTemperatureLowLimit | 1.3.6.1.4.1.850.101.1.1.3 | Integer32 | read-write | The lower alarm limit for ambient temperature (F). |
| I32 tlEnvTemperatureHighLimit | 1.3.6.1.4.1.850.101.1.1.4 | Integer32 | read-write | The upper alarm limit for ambient temperature (F). |
| T/F tlEnvTemperatureInAlarm | 1.3.6.1.4.1.850.101.1.1.5 | TruthValue | read-only | Indicates whether or not temperature is in alarm. |
| tlEnvHumidityData | 1.3.6.1.4.1.850.101.1.2 | |||
| I32 tlEnvHumidity | 1.3.6.1.4.1.850.101.1.2.1 | Integer32 | read-only | The ambient humidity (%). |
| I32 tlEnvHumidityLowLimit | 1.3.6.1.4.1.850.101.1.2.2 | Integer32 | read-write | The lower alarm limit for ambient humidity (%). |
| I32 tlEnvHumidityHighLimit | 1.3.6.1.4.1.850.101.1.2.3 | Integer32 | read-write | The upper alarm limit for ambient humidity (%). |
| T/F tlEnvHumidityInAlarm | 1.3.6.1.4.1.850.101.1.2.4 | TruthValue | read-only | Indicates whether or not humidity is in alarm. |
| tlEnvContacts | 1.3.6.1.4.1.850.101.2 | |||
| tlEnvContactTable | 1.3.6.1.4.1.850.101.2.1 | not-accessible | A table of contacts. | |
| tlEnvContactEntry | 1.3.6.1.4.1.850.101.2.1.1 | not-accessible | An entry containing information applicable to a particular contact. | |
| NUM tlEnvContactIndex | 1.3.6.1.4.1.850.101.2.1.1.1 | PositiveInteger | read-only | The table row index for the contact. |
| STR tlEnvContactName | 1.3.6.1.4.1.850.101.2.1.1.2 | DisplayString | read-write | The name or description of the contact. |
| INT tlEnvContactStatus | 1.3.6.1.4.1.850.101.2.1.1.3 | INTEGER | read-only | The current status of the contact. |
| INT tlEnvContactConfig | 1.3.6.1.4.1.850.101.2.1.1.4 | INTEGER | read-write | The configuration of the contact. |
| tlCooling | 1.3.6.1.4.1.850.103 | |||
| tlCoolingEnvironment | 1.3.6.1.4.1.850.103.1 | |||
| tlCoolingIdent | 1.3.6.1.4.1.850.103.1.1 | |||
| STR tlCoolingModel | 1.3.6.1.4.1.850.103.1.1.1 | DisplayString | read-only | The model name for the AC Unit. |
| STR tlCoolingManufacturer | 1.3.6.1.4.1.850.103.1.1.2 | DisplayString | read-only | The manufacturer of the AC Unit. |
| STR tlCoolingSerialNumber | 1.3.6.1.4.1.850.103.1.1.3 | DisplayString | read-only | The serial number of the AC unit. |
| STR tlCoolingFirmwareVersion | 1.3.6.1.4.1.850.103.1.1.4 | DisplayString | read-only | The firmware version of the AC Unit. |
| STR tlCoolingHostSoftwareVersion | 1.3.6.1.4.1.850.103.1.1.5 | DisplayString | read-only | The hardware version of the AC unit. |
| STR tlCoolingName | 1.3.6.1.4.1.850.103.1.1.6 | DisplayString | read-write | The user defined name for the AC Unit. |
| STR tlCoolingLocation | 1.3.6.1.4.1.850.103.1.1.7 | DisplayString | read-write | The user defined location of the AC Unit. |
| tlCoolingStatus | 1.3.6.1.4.1.850.103.1.2 | |||
| INT tlCoolingCondOutletTemp | 1.3.6.1.4.1.850.103.1.2.1 | INTEGER | read-only | The condenser outlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingCondInletTemp | 1.3.6.1.4.1.850.103.1.2.2 | INTEGER | read-only | The condenser inlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingRefrigerantTemp | 1.3.6.1.4.1.850.103.1.2.3 | INTEGER | read-only | The temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingEvapSurfaceTemp | 1.3.6.1.4.1.850.103.1.2.4 | INTEGER | read-only | The surface temperature of the evaporator in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingSuctionPressure | 1.3.6.1.4.1.850.103.1.2.5 | INTEGER | read-only | The pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. |
| INT tlCoolingDischargePressure | 1.3.6.1.4.1.850.103.1.2.6 | INTEGER | read-only | The pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits. |
| INT tlCoolingEvapFanSpeed | 1.3.6.1.4.1.850.103.1.2.7 | INTEGER | read-only | The current speed of the evaporator fan. |
| INT tlCoolingCondFanSpeed | 1.3.6.1.4.1.850.103.1.2.8 | INTEGER | read-only | The current speed of the condenser fan. |
| INT tlCoolingCompFrequency | 1.3.6.1.4.1.850.103.1.2.9 | INTEGER | read-only | The operating frequency of the compressor in tenths of Arms. |
| INT tlCoolingEEVPercentage | 1.3.6.1.4.1.850.103.1.2.10 | INTEGER | read-only | The opening percentage of the EEV. |
| INT tlCoolingUnitCurrent | 1.3.6.1.4.1.850.103.1.2.11 | INTEGER | read-only | The the total current draw of the unit in tenths of Arms. |
| INT tlCoolingFanCurrent | 1.3.6.1.4.1.850.103.1.2.12 | INTEGER | read-only | Thethe current draw of the Evaporator and Condenser fans in tents of Arms. |
| INT tlCoolingCompCurrent | 1.3.6.1.4.1.850.103.1.2.13 | INTEGER | read-only | The operating current of the compressor in Arms. |
| INT tlCoolingReturnAirTemp | 1.3.6.1.4.1.850.103.1.2.14 | INTEGER | read-only | The return air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingSuctionTemp | 1.3.6.1.4.1.850.103.1.2.15 | INTEGER | read-only | The temperature of the compressor suction line in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| INT tlCoolingSupplyAirTemp | 1.3.6.1.4.1.850.103.1.2.16 | INTEGER | read-only | The supply air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits. |
| tlCoolingRunTimes | 1.3.6.1.4.1.850.103.1.3 | |||
| I32 tlCoolingAirFilterRunHours | 1.3.6.1.4.1.850.103.1.3.1 | Integer32 | read-only | Total hours the air filter has been under operation. |
| I32 tlCoolingEvapFanRunDays | 1.3.6.1.4.1.850.103.1.3.2 | Integer32 | read-only | Total days the evaporator fan has been under operation. |
| I32 tlCoolingCondFanRunDays | 1.3.6.1.4.1.850.103.1.3.3 | Integer32 | read-only | Total days the condenser fan has been under operation. |
| I32 tlCoolingCompressorRunDays | 1.3.6.1.4.1.850.103.1.3.4 | Integer32 | read-only | Total days the compressor has been under operation. |
| I32 tlCoolingCondPumpRunDays | 1.3.6.1.4.1.850.103.1.3.5 | Integer32 | read-only | Total days the condensate pump has been under operation. |
| I32 tlCoolingAtomizerRunDays | 1.3.6.1.4.1.850.103.1.3.6 | Integer32 | read-only | Total days the atomizer has been under operation. |
| tlCoolingConfig | 1.3.6.1.4.1.850.103.1.4 | |||
| INT tlCoolingOnOff | 1.3.6.1.4.1.850.103.1.4.1 | INTEGER | read-write | Turn the unit off or on. |
| INT tlCoolingSetPointTemp | 1.3.6.1.4.1.850.103.1.4.2 | INTEGER | read-write | The set point temperature the unit will control the temperature to in tenths of degrees in Celcius or Fahrenheit based upon tleCoolDisplayUnits. |
| INT tlCoolingAutoStart | 1.3.6.1.4.1.850.103.1.4.3 | INTEGER | read-write | Specified if the unit should start automatically on power up. |
| INT tlCoolingFanSpeedOverride | 1.3.6.1.4.1.850.103.1.4.4 | INTEGER | read-write | Speed of evaporator fan set by the user. |
| INT tlCoolingControlType | 1.3.6.1.4.1.850.103.1.4.5 | INTEGER | read-write | Which temperature to be used as a control point. |
| INT tlCoolingCurrentRemoteTemp | 1.3.6.1.4.1.850.103.1.4.6 | INTEGER | read-write | The external remote temperature in tenths of degrees in Celcius or Fahrenheit depending upon value of tlCoolingDisplayUnits |
| INT tlCoolingDisplayUnits | 1.3.6.1.4.1.850.103.1.4.7 | INTEGER | read-write | Selects English or Metric display for all readings. |
| INT tlCoolingBeepOnKey | 1.3.6.1.4.1.850.103.1.4.8 | INTEGER | read-write | Indicates if the display sounds a beep when a key is pressed. |
| INT tlCoolingOutputRelaySource | 1.3.6.1.4.1.850.103.1.4.9 | INTEGER | read-write | The alarm level that causes the ouput relay to activate. |
| INT tlCoolingOffOnLeak | 1.3.6.1.4.1.850.103.1.4.10 | INTEGER | read-write | Indicates if the unit should stop cooling when leak input is activated. |
| INT tlCoolingOffOnInputContact | 1.3.6.1.4.1.850.103.1.4.11 | INTEGER | read-write | Indicates if the unit should stop cooling when input contact is activated. |
| INT tlCoolingInputContactType | 1.3.6.1.4.1.850.103.1.4.12 | INTEGER | read-write | The input contact type. |
| INT tlCoolingOutputRelayDefault | 1.3.6.1.4.1.850.103.1.4.13 | INTEGER | read-write | Type of contact to make when output relay is activated. |
| I32 tlCoolingAirFilterInterval | 1.3.6.1.4.1.850.103.1.4.14 | Integer32 | read-write | The number of weeks before the air filter needs to be changed. |
| INT tlCoolingWaterLeakContactType | 1.3.6.1.4.1.850.103.1.4.15 | INTEGER | read-write | The input contact type. |
| tlCoolingThresholds | 1.3.6.1.4.1.850.103.1.5 | |||
| I32 tlCoolingMaxAirFilterRunHours | 1.3.6.1.4.1.850.103.1.5.1 | Integer32 | read-write | The maximum interval for air filter run hours before warning is annunciated. |
| INT tlCoolingEnableAirFilterAlarm | 1.3.6.1.4.1.850.103.1.5.2 | INTEGER | read-write | When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded. |
| INT tlCoolingMaxSupplyTemp | 1.3.6.1.4.1.850.103.1.5.3 | INTEGER | read-write | Maximum allowed supply air temperature before firing an alarm. |
| INT tlCoolingMinSupplyTemp | 1.3.6.1.4.1.850.103.1.5.4 | INTEGER | read-write | Minimum allowed supply air temperature allowed before firing an alarm. |
| INT tlCoolingTempDiffAlarm | 1.3.6.1.4.1.850.103.1.5.5 | INTEGER | read-write | Maximum allowed air temperature deviation from set allowed before firing an alarm. |
| INT tlCoolingMaxReturnAirTemp | 1.3.6.1.4.1.850.103.1.5.6 | INTEGER | read-write | When enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded. |
| tlCoolingAlarm | 1.3.6.1.4.1.850.103.6 | |||
| tlCoolingWellKnownAlarms | 1.3.6.1.4.1.850.103.6.3 | |||
| tlCoolingSupplyAirSensorFault | 1.3.6.1.4.1.850.103.6.3.1 | The supply air sensor is in fault. | ||
| tlCoolingReturnAirSensorFault | 1.3.6.1.4.1.850.103.6.3.2 | The return air sensor is in fault. | ||
| tlCoolingCondenserInletAirSensorFault | 1.3.6.1.4.1.850.103.6.3.3 | The condenser inlet air sensor is in fault. | ||
| tlCoolingCondenserOutletAirSensorFault | 1.3.6.1.4.1.850.103.6.3.4 | The condenser outlet air sensor is in fault. | ||
| tlCoolingSuctionTemperatureSensorFault | 1.3.6.1.4.1.850.103.6.3.5 | The suction temperature sensor is in fault. | ||
| tlCoolingEvaporatorTemperatureSensorFault | 1.3.6.1.4.1.850.103.6.3.6 | The evaporator temperature sensor is in fault. | ||
| tlCoolingAirFilterClogged | 1.3.6.1.4.1.850.103.6.3.7 | The air filter is clogged. | ||
| tlCoolingAirFilterRunHoursViolation | 1.3.6.1.4.1.850.103.6.3.8 | The air filter run hours was violated. | ||
| tlCoolingSuctionPressureSensorFault | 1.3.6.1.4.1.850.103.6.3.9 | The suction pressure sensor is in fault. | ||
| tlCoolingInverterCommunicationsFault | 1.3.6.1.4.1.850.103.6.3.10 | The inverter communications is in fault. | ||
| tlCoolingRemoteShutdownViaInputContact | 1.3.6.1.4.1.850.103.6.3.11 | A remote shutdown was triggerd by an input contact. | ||
| tlCoolingCondensatePumpFault | 1.3.6.1.4.1.850.103.6.3.12 | The condensate pump is in fault. | ||
| tlCoolingLowRefrigerantStartupFault | 1.3.6.1.4.1.850.103.6.3.13 | The low refrigerant startup is in fault. | ||
| tlCoolingCondenserFanFault | 1.3.6.1.4.1.850.103.6.3.14 | The condenser fan is in fault. | ||
| tlCoolingCondenserFailure | 1.3.6.1.4.1.850.103.6.3.15 | The condenser has failed. | ||
| tlCoolingEvaporatorCoolingFailure | 1.3.6.1.4.1.850.103.6.3.16 | The evaporator cooling is in fault. | ||
| tlCoolingReturnAirTempHigh | 1.3.6.1.4.1.850.103.6.3.17 | The return air temperature is high. | ||
| tlCoolingSupplyAirTempHigh | 1.3.6.1.4.1.850.103.6.3.18 | The supply air temperature is high. | ||
| tlCoolingEvaporatorFailure | 1.3.6.1.4.1.850.103.6.3.19 | The evaporator has failed. | ||
| tlCoolingEvaporatorFreezeUp | 1.3.6.1.4.1.850.103.6.3.20 | The evaporator is frozen. | ||
| tlCoolingDischargePressureHigh | 1.3.6.1.4.1.850.103.6.3.21 | The discharge pressure is high. | ||
| tlCoolingPressureGaugeFailure | 1.3.6.1.4.1.850.103.6.3.22 | The pressure gauge has failed. | ||
| tlCoolingDischargePressurePersistentHigh | 1.3.6.1.4.1.850.103.6.3.23 | The discharge pressure is persistently high. | ||
| tlCoolingSuctionPressureLowStartFailure | 1.3.6.1.4.1.850.103.6.3.24 | Cannot start due to low suction pressure. | ||
| tlCoolingSuctionPressureLow | 1.3.6.1.4.1.850.103.6.3.25 | The suction pressure is low. | ||
| tlCoolingSuctionPressurePersistentLow | 1.3.6.1.4.1.850.103.6.3.26 | The suction pressure is persistently low. | ||
| tlCoolingStartupLinePressureImbalance | 1.3.6.1.4.1.850.103.6.3.27 | The startup line pressure is in imbalance. | ||
| tlCoolingCompressorFailure | 1.3.6.1.4.1.850.103.6.3.28 | The compressor has failed. | ||
| tlCoolingCurrentLimit | 1.3.6.1.4.1.850.103.6.3.29 | The current is out of range. | ||
| tlCoolingWaterLeak | 1.3.6.1.4.1.850.103.6.3.30 | Water is leaking. | ||
| tlCoolingFanUnderCurrent | 1.3.6.1.4.1.850.103.6.3.31 | The fan is under current. | ||
| tlCoolingFanOverCurrent | 1.3.6.1.4.1.850.103.6.3.32 | The fan is over current. | ||
| tlCoolingDischargePressureSensorFault | 1.3.6.1.4.1.850.103.6.3.33 | The discharge pressure sensor is in fault. | ||
| tlCoolingWaterFull | 1.3.6.1.4.1.850.103.6.3.34 | Water is Full. |
RFC description
Manages Tripp Lite UPS and power supply status, battery health, and environmental sensors.
Start monitoring Tripp Lite UPS (uninterruptible power supply) with PowerAlert management (battery charge/load/alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.