All MIBs › OMNI-gx2drr4x-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 DRR4X downstream RF receiver card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2drr4x-MIB?
OMNI-gx2drr4x-MIB is a vendor MIB (Cisco/Scientific-Atlanta OMNI platform) for the GX2 DRR4X downstream RF receiver card, used in Hybrid Fiber-Coax (HFC) optical node equipment in cable/broadband access networks. It is expected to expose configuration and status data for the RF receiver card's downstream signal parameters, such as RF input level, channel configuration, and card operational status within the optical node chassis. Because no sample objects were available, its exact monitoring capability cannot be confirmed in detail, but a downstream RF receiver card MIB of this type typically supports hardware health monitoring such as card presence/operational status and RF signal level, relevant to detecting a failed or degraded receiver card. It is a vendor-specific module likely built on the broader OMNI/Scientific-Atlanta optical node platform MIB framework for chassis and slot management. It is typically deployed in cable operator HFC network optical nodes that convert fiber-delivered signals to RF for coax distribution to subscribers. Engineers can download the OMNI-gx2drr4x-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2drr4x-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR4X downstream RF receiver card)
Monitoring Examples
No sample objects were provided for this MIB, so a concrete monitoring example with real object names cannot be honestly given; in general terms an operator would expect to poll the GX2 DRR4X card's operational status and downstream RF signal level to detect a failed or degraded receiver card affecting subscriber service in that HFC node.
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Drr4x | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapdrrConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.14.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrrConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.14.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapdrr12VCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.3 | This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.4 | This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrFanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.5 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapdrrFlashAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.6 | This trap is issued when the detects an error during Flash memory operations. | ||
| NTF trapdrrBankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.7 | This trap is issued when the module detects an error while booting from bank 0 or bank 1. | ||
| NTF trapdrrAlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.8 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapdrrHardwareErrAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.9 | This trap is issued when hardware is abnormal. | ||
| NTF trapdrrOpticalSignalAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.10 | This trap is issued when the optical signal is beyond the preset range. | ||
| NTF trapdrrFactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.11 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapdrrResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.12 | This trap is issued when the Factory Default Reset occurs. | ||
| NTF trapdrrTripPointAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.13 | This trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM. | ||
| NTF trapdrrLinkAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.14 | This trap is issued when receiver is out of SYN with transmitter | ||
| NTF trapdrrCalibrationDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.14.0.15 | This trap is issued when the Calibration Data CRC is incorrect | ||
| gx2drr4xDescriptor | 1.3.6.1.4.1.1166.6.1.2.14.1 | |||
| gx2drr4xAnalogTable | 1.3.6.1.4.1.1166.6.1.2.14.2 | not-accessible | This table contains gx2drr4x specific analog parameters with nominal,limits and current values. | |
| gx2drr4xAnalogEntry | 1.3.6.1.4.1.1166.6.1.2.14.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2drr4xAnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.14.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr4xlabelRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.2 | DisplayString | read-only | The value of this object provides the label of the RF Channel A Attenuation Analog parameter. |
| STR drr4xuomRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB |
| FLO drr4xmajorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.4 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xmajorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.5 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorHighRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.6 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.7 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xcurrentValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.8 | Float | read-write | The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter. |
| INT drr4xstateFlagRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.9 | INTEGER | read-only | The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.10 | Float | read-only | The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive. |
| FLO drr4xmaxValueRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.11 | Float | read-only | The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive. |
| INT drr4xalarmStateRFAAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter. |
| STR drr4xlabelRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.13 | DisplayString | read-only | The value of this object provides the label of the RF Channel B Attenuation Analog parameter. |
| STR drr4xuomRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter. |
| FLO drr4xmajorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.15 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xmajorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.16 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorHighRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.17 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.18 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence. |
| FLO drr4xcurrentValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.19 | Float | read-write | The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB |
| INT drr4xstateFlagRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.20 | INTEGER | read-only | The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.21 | Float | read-only | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. |
| FLO drr4xmaxValueRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.22 | Float | read-only | The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive. |
| INT drr4xalarmStateRFBAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter. |
| STR drr4xlabelRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.24 | DisplayString | read-only | The value of this object provides the label of the RF Channel C Attenuation Analog parameter. |
| STR drr4xuomRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter. |
| FLO drr4xmajorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.26 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xmajorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.27 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorHighRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.28 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.29 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence. |
| FLO drr4xcurrentValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.30 | Float | read-write | The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. The unit is dB |
| INT drr4xstateFlagRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.31 | INTEGER | read-only | The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.32 | Float | read-only | The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive. |
| FLO drr4xmaxValueRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.33 | Float | read-only | The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive. |
| INT drr4xalarmStateRFCAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter. |
| STR drr4xlabelRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.35 | DisplayString | read-only | The value of this object provides the label of the RF Channel D Attenuation Analog parameter. |
| STR drr4xuomRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter. |
| FLO drr4xmajorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.37 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xmajorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.38 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorHighRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.39 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.40 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence. |
| FLO drr4xcurrentValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.41 | Float | read-write | The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. The unit is dB |
| INT drr4xstateFlagRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.42 | INTEGER | read-only | The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.43 | Float | read-only | The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive. |
| FLO drr4xmaxValueRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.44 | Float | read-only | The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive. |
| INT drr4xalarmStateRFDAttenuation | 1.3.6.1.4.1.1166.6.1.2.14.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter. |
| STR drr4xlabelTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.46 | DisplayString | read-only | The value of this object provides the label of the trip point level Analog parameter. |
| STR drr4xuomTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the trip point level Analog parameter. |
| FLO drr4xmajorHighTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.48 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xmajorLowTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.49 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorHighTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.50 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.51 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xcurrentValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.52 | Float | read-write | The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number. |
| INT drr4xstateFlagTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.53 | INTEGER | read-only | The value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.54 | Float | read-only | The value of this object provides the minimum value the trip point level Analog parameter can achive. |
| FLO drr4xmaxValueTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.55 | Float | read-only | The value of this object provides the maximum value the trip point level Analog parameter can achive. |
| INT drr4xalarmStateTrippointLevel | 1.3.6.1.4.1.1166.6.1.2.14.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the trip point level Analog parameter. |
| STR drr4xlabelOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Optical Power Current Analog parameter. |
| STR drr4xuomOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter. |
| FLO drr4xmajorHighOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter. |
| FLO drr4xmajorLowOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter. |
| FLO drr4xminorHighOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.61 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.62 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xcurrentValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.63 | Float | read-only | The value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr4xcurrentValueOptCurrent will report -99dBm The input optical power in higher than this value, drr4xcurrentValueOptCurrent will report 99dBm |
| INT drr4xstateFlagOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.65 | Float | read-only | This is recommended min range for display gauge |
| FLO drr4xmaxValueOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.66 | Float | read-only | This is recommended max range for display gauge |
| INT drr4xalarmStateOptCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Current Analog parameter. |
| STR drr4xlabel12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.68 | DisplayString | read-only | The value of this object provides the label of the 12v power supply Current Analog parameter. |
| STR drr4xuom12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter. |
| FLO drr4xmajorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter. |
| FLO drr4xmajorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter. |
| FLO drr4xminorHigh12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter. |
| FLO drr4xminorLow12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter. |
| FLO drr4xcurrentValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.74 | Float | read-only | The value of this object provides the Current value of the 12v power supply Current parameter. |
| INT drr4xstateFlag12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.75 | INTEGER | read-only | The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.76 | Float | read-only | The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive. |
| FLO drr4xmaxValue12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.77 | Float | read-only | The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive. |
| INT drr4xalarmState12VCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter. |
| STR drr4xlabelModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR drr4xuomModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO drr4xmajorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO drr4xmajorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO drr4xminorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO drr4xminorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO drr4xcurrentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.85 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT drr4xstateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.87 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| FLO drr4xmaxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.88 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| INT drr4xalarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.14.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR drr4xlabelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR drr4xuomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO drr4xmajorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| FLO drr4xmajorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| FLO drr4xminorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.94 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xminorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.95 | Float | read-only | This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence. |
| FLO drr4xcurrentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. |
| INT drr4xstateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO drr4xminValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| FLO drr4xmaxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| INT drr4xalarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.14.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2drr4xDigitalTable | 1.3.6.1.4.1.1166.6.1.2.14.3 | not-accessible | This table contains gx2drr4x specific digital parameters with nominal and current values. | |
| gx2drr4xDigitalEntry | 1.3.6.1.4.1.1166.6.1.2.14.3.2 | not-accessible | This list contains individual digital parameters and descriptions. | |
| INT gx2drr4xDigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.14.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr4xlabelTrippointMode | 1.3.6.1.4.1.1166.6.1.2.14.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR |
| STR drr4xenumTrippointMode | 1.3.6.1.4.1.1166.6.1.2.14.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. |
| INT drr4xvalueTrippointMode | 1.3.6.1.4.1.1166.6.1.2.14.3.2.4 | INTEGER | read-write | The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml |
| INT drr4xstateflagTrippointMode | 1.3.6.1.4.1.1166.6.1.2.14.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.14.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR drr4xenumFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.14.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT drr4xvalueFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.14.3.2.8 | INTEGER | read-write | The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter |
| INT drr4xstateflagFactoryDefaultReset | 1.3.6.1.4.1.1166.6.1.2.14.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2drr4xStatusTable | 1.3.6.1.4.1.1166.6.1.2.14.4 | not-accessible | This table contains gx2drr4x specific status parameters with nominal and current values. | |
| gx2drr4xStatusEntry | 1.3.6.1.4.1.1166.6.1.2.14.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2drr4xStatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.14.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR drr4xlabelBoot | 1.3.6.1.4.1.1166.6.1.2.14.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status parameter. |
| INT drr4xvalueBoot | 1.3.6.1.4.1.1166.6.1.2.14.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagBoot | 1.3.6.1.4.1.1166.6.1.2.14.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelFlash | 1.3.6.1.4.1.1166.6.1.2.14.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status parameter. |
| INT drr4xvalueFlash | 1.3.6.1.4.1.1166.6.1.2.14.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagFlash | 1.3.6.1.4.1.1166.6.1.2.14.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.14.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT drr4xvalueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.14.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.14.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT drr4xvalueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data Crc parameter. |
| INT drr4xvalueCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagCalibrationDataCrc | 1.3.6.1.4.1.1166.6.1.2.14.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Module Hardware Status parameter. |
| INT drr4xvalueHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagHardwareStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.19 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value |
| INT drr4xvalueOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagOpticTripPointStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.22 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| STR drr4xlabelLinkStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal. |
| INT drr4xvalueLinkStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical). |
| INT drr4xstateflagLinkStatus | 1.3.6.1.4.1.1166.6.1.2.14.4.3.25 | INTEGER | read-only | The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable). |
| gx2drr4xFactoryTable | 1.3.6.1.4.1.1166.6.1.2.14.5 | not-accessible | This table contains gx2drr4x specific factory setting parameters with nominal and current values. | |
| gx2drr4xFactoryEntry | 1.3.6.1.4.1.1166.6.1.2.14.5.4 | not-accessible | This list contains Factory setting parameters and descriptions. | |
| INT gx2drr4xFactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.14.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT drr4xbootControlByte | 1.3.6.1.4.1.1166.6.1.2.14.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT drr4xbootStatusByte | 1.3.6.1.4.1.1166.6.1.2.14.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT drr4xbank1CRC | 1.3.6.1.4.1.1166.6.1.2.14.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT drr4xbank2CRC | 1.3.6.1.4.1.1166.6.1.2.14.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT drr4xprgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.14.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT drr4xfactoryCRC | 1.3.6.1.4.1.1166.6.1.2.14.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT drr4xcalculateCRC | 1.3.6.1.4.1.1166.6.1.2.14.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration). |
| INT drr4xhourMeter | 1.3.6.1.4.1.1166.6.1.2.14.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT drr4xflashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.14.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 0 flash has been programmed. |
| INT drr4xflashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.14.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR drr4xflashBankARev | 1.3.6.1.4.1.1166.6.1.2.14.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR drr4xflashBankBRev | 1.3.6.1.4.1.1166.6.1.2.14.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| STR drr4xSubAgentRev | 1.3.6.1.4.1.1166.6.1.2.14.5.4.14 | DisplayString | read-only | This object provides the subagent revision of receiver module. |
RFC description
Management for OMNISTAR digital receiver return 4X module in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR4X downstream RF receiver card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.