Type: Float

Access: read-write

Description: The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance.

when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number.

What is drr4xcurrentValueTrippointLevel?

Returns the currently configured optical-power trip point level -- the customer-preferred input optical power threshold that determines when the RF switch/alarm behavior described by drr4xvalueTrippointMode kicks in. The MIB marks it read-write, so this is also the object an admin would set to change the threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.14.2.1.52
snmpwalk -v2c -c public <target> OMNI-gx2drr4x-MIB::drr4xcurrentValueTrippointLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.14.2.1.52.1
snmpget -v2c -c public <target> OMNI-gx2drr4x-MIB::drr4xcurrentValueTrippointLevel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.14.2.1.52.1 s <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR4X downstream RF receiver card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2drr4x-MIB::drr4xcurrentValueTrippointLevel OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR4X downstream RF receiver card) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.14gx2Drr4xGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.14.2gx2drr4xAnalogTableOMNI-gx2drr4x-MIB
1.3.6.1.4.1.1166.6.1.2.14.2.1gx2drr4xAnalogEntryOMNI-gx2drr4x-MIB
1.3.6.1.4.1.1166.6.1.2.14.2.1.52drr4xcurrentValueTrippointLevelOMNI-gx2drr4x-MIB