| OID symbolic | OID numeric | Type | Access | Description |
| NTF trapRSW200ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.8.0.1 | | | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapRSW200ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.8.0.2 | | | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' |
| NTF trapRSW200RFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.3 | | | This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
| NTF trapRSW200FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.4 | | | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
| NTF trapRSW200ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.5 | | | This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. |
| NTF trapRSW200FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.6 | | | This trap is issued when the detects an error during Flash memory operations. |
| NTF trapRSW200BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.7 | | | This trap is issued when the detects an error while booting from bank 0 or bank 1. |
| NTF trapRSW200AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.8 | | | This trap is issued when the Alarm Data CRC is incorrect. |
| NTF trapRSW200FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.9 | | | This trap is issued when the Factory Data CRC is incorrect. |
| NTF trapRSW200InputSwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.10 | | | This trap is issued when the RF input switched. |
| NTF trapRSW200ResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.11 | | | This trap is issued when the Factory Default Reset occurs. |
| NTF trapRSW200SecondaryInputActiveAlarm | 1.3.6.1.4.1.1166.6.1.2.8.0.12 | | | This trap is issued when the scondary input becomes active. |
| gx2Rsw200Descriptor | 1.3.6.1.4.1.1166.6.1.2.8.1 | | | |
| gx2Rsw200AnalogTable | 1.3.6.1.4.1.1166.6.1.2.8.2 | | not-accessible | This table contains gx2Rsw200 specific parameters with
nominal and current values. |
| gx2Rsw200AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.8.2.1 | | not-accessible | This list contains the analog parameters and descriptions. |
| INT gx2Rsw200AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.8.2.1.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| STR rsw200labelModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.2 | DisplayString | read-only | The value of this object provides the label of the
Module Temperature Analog parameter. |
| STR rsw200uomModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the
Module Temperature Analog parameter. |
| FLO rsw200majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.8 | Float | read-only | The value of this object provides the Current value
of the Module Temperature Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rsw200stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.9 | INTEGER | read-only | The value of this object provides the state
of the Module Temperature Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
| FLO rsw200minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.10 | Float | read-only | The value of this object provides the minimum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.11 | Float | read-only | The value of this object provides the maximum value
the Module Temperature Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rsw200alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.8.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of
the Module Temperature Analog parameter. |
| STR rsw200labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.13 | DisplayString | read-only | The value of this object provides the label of the
Fan Current Analog parameter. |
| STR rsw200uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the
Fan Current Analog parameter. |
| FLO rsw200majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.19 | Float | read-only | The value of this object provides the Current value
of the Fan Current Analog parameter.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rsw200stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.20 | INTEGER | read-only | The value of this object provides the state
of the Fan Current Analog parameter. (0-Hidden
1-Read-Only, 2-Updateable). |
| FLO rsw200minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.21 | Float | read-only | The value of this object provides the minimum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rsw200maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.22 | Float | read-only | The value of this object provides the maximum value
the Fan Current Analog parameter can achive.
This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rsw200alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.8.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of
the Fan Current Analog parameter. |
| gx2Rsw200DigitalTable | 1.3.6.1.4.1.1166.6.1.2.8.3 | | not-accessible | This table contains gx2Rsw200 specific parameters with
nominal and current values. |
| gx2Rsw200DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.8.3.2 | | not-accessible | This list contains digital parameters and descriptions. |
| INT gx2Rsw200DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.8.3.2.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| STR rsw200labelSwitchControl | 1.3.6.1.4.1.1166.6.1.2.8.3.2.2 | DisplayString | read-only | The value of this object provides the label of the
Switch Control Digital parameter. |
| STR rsw200enumSwitchControl | 1.3.6.1.4.1.1166.6.1.2.8.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueSwitchControl | 1.3.6.1.4.1.1166.6.1.2.8.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw200stateflagSwitchControl | 1.3.6.1.4.1.1166.6.1.2.8.3.2.5 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelRevertMode | 1.3.6.1.4.1.1166.6.1.2.8.3.2.6 | DisplayString | read-only | The value of this object provides the label of the
Revert Mode Digital parameter. |
| STR rsw200enumRevertMode | 1.3.6.1.4.1.1166.6.1.2.8.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueRevertMode | 1.3.6.1.4.1.1166.6.1.2.8.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw200stateflagRevertMode | 1.3.6.1.4.1.1166.6.1.2.8.3.2.9 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelRevertTime | 1.3.6.1.4.1.1166.6.1.2.8.3.2.10 | DisplayString | read-only | The value of this object provides the label of the
Revert Time Digital parameter. |
| STR rsw200enumRevertTime | 1.3.6.1.4.1.1166.6.1.2.8.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueRevertTime | 1.3.6.1.4.1.1166.6.1.2.8.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw200stateflagRevertTime | 1.3.6.1.4.1.1166.6.1.2.8.3.2.13 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelSwitchState | 1.3.6.1.4.1.1166.6.1.2.8.3.2.14 | DisplayString | read-only | The value of this object provides the label of the
Switch State Digital parameter. |
| STR rsw200enumSwitchState | 1.3.6.1.4.1.1166.6.1.2.8.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueSwitchState | 1.3.6.1.4.1.1166.6.1.2.8.3.2.16 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw200stateflagSwitchState | 1.3.6.1.4.1.1166.6.1.2.8.3.2.17 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelPriStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.18 | DisplayString | read-only | The value of this object provides the label of the
Primary Signal Status Digital parameter. |
| STR rsw200enumPriStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valuePriStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.20 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw200stateflagPriStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.21 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelSecStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.22 | DisplayString | read-only | The value of this object provides the label of the
Secondary Signal Status Digital parameter. |
| STR rsw200enumSecStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueSecStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.24 | INTEGER | read-only | The value of this object is the current value of the parameter. |
| INT rsw200stateflagSecStatus | 1.3.6.1.4.1.1166.6.1.2.8.3.2.25 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.8.3.2.26 | DisplayString | read-only | The value of this object provides the label of the
Factory Default Reset Digital parameter. |
| STR rsw200enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.8.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values
possible for the Digital parameter. Each Enumerated values is
separated by a common. The first value has a enumerated value of 1. |
| INT rsw200valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.8.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rsw200stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.8.3.2.29 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rsw200StatusTable | 1.3.6.1.4.1.1166.6.1.2.8.4 | | not-accessible | This table contains gx2Rsw200 specific parameters with
nominal and current values. |
| gx2Rsw200StatusEntry | 1.3.6.1.4.1.1166.6.1.2.8.4.3 | | not-accessible | This list contains Status parameters and descriptions. |
| INT gx2Rsw200StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.8.4.3.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| STR rsw200labelBoot | 1.3.6.1.4.1.1166.6.1.2.8.4.3.2 | DisplayString | read-only | The value of this object provides the label of the
Boot Status Status parameter. |
| INT rsw200valueBoot | 1.3.6.1.4.1.1166.6.1.2.8.4.3.3 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.8.4.3.4 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelFlash | 1.3.6.1.4.1.1166.6.1.2.8.4.3.5 | DisplayString | read-only | The value of this object provides the label of the
Flash Status Status parameter. |
| INT rsw200valueFlash | 1.3.6.1.4.1.1166.6.1.2.8.4.3.6 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.8.4.3.7 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.8.4.3.8 | DisplayString | read-only | The value of this object provides the label of the
Factory Data CRC Status parameter. |
| INT rsw200valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.8.4.3.9 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.8.4.3.10 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.8.4.3.11 | DisplayString | read-only | The value of this object provides the label of the
Alarm Data Crc parameter. |
| INT rsw200valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.8.4.3.12 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.8.4.3.13 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.14 | DisplayString | read-only | The value of this object provides the label of the
RF Signal Status parameter. |
| INT rsw200valueRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.15 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagRFSignalStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.16 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rsw200labelPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.17 | DisplayString | read-only | The value of this object provides the label of the
Secondary Active Status parameter. |
| INT rsw200valuePriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.18 | INTEGER | read-only | The value of this object provides the current state of
the parameter (0-Ok, 1-Undetermined
2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rsw200stateflagPriActiveStatus | 1.3.6.1.4.1.1166.6.1.2.8.4.3.19 | INTEGER | read-only | The value of this object provides the state
of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rsw200FactoryTable | 1.3.6.1.4.1.1166.6.1.2.8.5 | | not-accessible | This table contains gx2Rsw200 specific parameters with
nominal and current values. |
| gx2Rsw200FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.8.5.4 | | not-accessible | This list contains Factory parameters and descriptions. |
| INT gx2Rsw200FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.8.5.4.1 | INTEGER | read-only | The value of this object identifies the network
element. This index is equal to the
hfcCommonTableIndex for the same element. |
| INT rsw200bootControlByte | 1.3.6.1.4.1.1166.6.1.2.8.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware
is currently being boot from. |
| INT rsw200bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.8.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rsw200bank1CRC | 1.3.6.1.4.1.1166.6.1.2.8.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rsw200bank2CRC | 1.3.6.1.4.1.1166.6.1.2.8.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rsw200prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.8.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rsw200factoryCRC | 1.3.6.1.4.1.1166.6.1.2.8.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rsw200calculateCRC | 1.3.6.1.4.1.1166.6.1.2.8.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT rsw200hourMeter | 1.3.6.1.4.1.1166.6.1.2.8.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT rsw200flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.8.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been
programmed. |
| INT rsw200flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.8.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been
programmed. |
| STR rsw200flashBankARev | 1.3.6.1.4.1.1166.6.1.2.8.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR rsw200flashBankBRev | 1.3.6.1.4.1.1166.6.1.2.8.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Rsw200bHoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.8.6 | | not-accessible | This table contains gx2Rsw200b specific parameters with
nominal and current values. |
| gx2Rsw200bHoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.8.6.5 | | not-accessible | This list contains digital product class and the
associated RF channel parameters and descriptions. |
| INT rxgx2Rsw200bHoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.8.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT rxgx2Rsw200bHoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.8.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT rxgx2Rsw200bHoldTimeData | 1.3.6.1.4.1.1166.6.1.2.8.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used
to suppress nose on analog objects. This object is a 32 bit object.
Validation data is entered into bytes zero and one of the object.
Bytes three and four are used to entering the hold time for the
specified alarm object. The Hold timer data ranges from 0 to 1300 seconds.
The index of this object corresponds to the alarm object to be modified.
Alarm Hold timers correspond to the index of this object as follows:
Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx,
The hold time is represented in seconds. |