OMNI-gx2Lm870C-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI -- IpAddress, TimeTicks -- FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Lm870C FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "1" Jan 20, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Laser Module (Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Lm870C Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Lm870C device type. -- These parameters are common across all network elements -- from gx2Lm870C device type. -- -- The gx2Lm870C Network Elements subgroup is -- a list of gx2Lm870C type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Lm870CTableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Lm870C type. -- -- Both groups are mandatory for management of gx2Lm870C devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Lm870C Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Lm870C device type. -- These parameters are common across all network elements -- from gx2Lm870C device type. gx2Lm870CDescriptor OBJECT IDENTIFIER ::= {gx2Lm870C 1} --***************************************************************************** -- gx2Lm870C Table -- Contains a list of all gx2Lm870C type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Lm870CTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Lm870C type. gx2lm870CAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Lm870CAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Lm870C specific parameters with nominal and current values." ::= { gx2Lm870C 2 } gx2lm870CAnalogEntry OBJECT-TYPE SYNTAX Gx2Lm870CAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2Lm870CAnalogTableIndex } ::= { gx2lm870CAnalogTable 1} --************************************************************************* gx2lm870CDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Lm870CDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Lm870C specific parameters with discrete values." ::= { gx2Lm870C 3 } gx2lm870CDigitalEntry OBJECT-TYPE SYNTAX Gx2Lm870CDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2Lm870CDigitalTableIndex } ::= { gx2lm870CDigitalTable 2} --************************************************************************* gx2lm870CStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Lm870CStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Lm870C specific parameters with current values." ::= { gx2Lm870C 4 } gx2lm870CStatusEntry OBJECT-TYPE SYNTAX Gx2Lm870CStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2Lm870CStatusTableIndex } ::= { gx2lm870CStatusTable 3} --************************************************************************* gx2lm870CFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Lm870CFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Lm870C specific parameters with stored factory values." ::= { gx2Lm870C 5 } gx2lm870CFactoryEntry OBJECT-TYPE SYNTAX Gx2Lm870CFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2Lm870CFactoryTableIndex } ::= { gx2lm870CFactoryTable 4} --************************************************************************* Gx2Lm870CAnalogEntry ::= SEQUENCE { gx2Lm870CAnalogTableIndex INTEGER, -- Analog Parameters lm870ClabelFanCurrent DisplayString (SIZE (0..80)), lm870CuomFanCurrent DisplayString (SIZE (0..80)), lm870CmajorHighFanCurrent Float, lm870CmajorLowFanCurrent Float, lm870CminorHighFanCurrent Float, lm870CminorLowFanCurrent Float, lm870CcurrentValueFanCurrent Float, lm870CstateFlagFanCurrent INTEGER, lm870CminValueFanCurrent Float, lm870CmaxValueFanCurrent Float, lm870CalarmStateFanCurrent INTEGER, lm870Clabel12Volt DisplayString (SIZE (0..80)), lm870Cuom12Volt DisplayString (SIZE (0..80)), lm870CmajorHigh12Volt Float, lm870CmajorLow12Volt Float, lm870CminorHigh12Volt Float, lm870CminorLow12Volt Float, lm870CcurrentValue12Volt Float, lm870CstateFlag12Volt INTEGER, lm870CminValue12Volt Float, lm870CmaxValue12Volt Float, lm870CalarmState12Volt INTEGER, lm870ClabelModTemp DisplayString (SIZE (0..80)), lm870CuomModTemp DisplayString (SIZE (0..80)), lm870CmajorHighModTemp Float, lm870CmajorLowModTemp Float, lm870CminorHighModTemp Float, lm870CminorLowModTemp Float, lm870CcurrentValueModTemp Float, lm870CstateFlagModTemp INTEGER, lm870CminValueModTemp Float, lm870CmaxValueModTemp Float, lm870CalarmStateModTemp INTEGER, lm870ClabelOmiOffset DisplayString (SIZE (0..80)), lm870CuomOmiOffset DisplayString (SIZE (0..80)), lm870CmajorHighOmiOffset Float, lm870CmajorLowOmiOffset Float, lm870CminorHighOmiOffset Float, lm870CminorLowOmiOffset Float, lm870CcurrentValueOmiOffset Float, lm870CstateFlagOmiOffset INTEGER, lm870CminValueOmiOffset Float, lm870CmaxValueOmiOffset Float, lm870CalarmStateOmiOffset INTEGER, lm870ClabelOPTPower DisplayString (SIZE (0..80)), lm870CuomOPTPower DisplayString (SIZE (0..80)), lm870CmajorHighOPTPower Float, lm870CmajorLowOPTPower Float, lm870CminorHighOPTPower Float, lm870CminorLowOPTPower Float, lm870CcurrentValueOPTPower Float, lm870CstateFlagOPTPower INTEGER, lm870CminValueOPTPower Float, lm870CmaxValueOPTPower Float, lm870CalarmStateOPTPower INTEGER, lm870ClabelLaserBias DisplayString (SIZE (0..80)), lm870CuomLaserBias DisplayString (SIZE (0..80)), lm870CmajorHighLaserBias Float, lm870CmajorLowLaserBias Float, lm870CminorHighLaserBias Float, lm870CminorLowLaserBias Float, lm870CcurrentValueLaserBias Float, lm870CstateFlagLaserBias INTEGER, lm870CminValueLaserBias Float, lm870CmaxValueLaserBias Float, lm870CalarmStateLaserBias INTEGER, lm870ClabelTecCurrent DisplayString (SIZE (0..80)), lm870CuomTecCurrent DisplayString (SIZE (0..80)), lm870CmajorHighTecCurrent Float, lm870CmajorLowTecCurrent Float, lm870CminorHighTecCurrent Float, lm870CminorLowTecCurrent Float, lm870CcurrentValueTecCurrent Float, lm870CstateFlagTecCurrent INTEGER, lm870CminValueTecCurrent Float, lm870CmaxValueTecCurrent Float, lm870CalarmStateTecCurrent INTEGER, lm870ClabelOmiAlarmSetpoint DisplayString (SIZE (0..80)), lm870CuomOmiAlarmSetpoint DisplayString (SIZE (0..80)), lm870CmajorHighOmiAlarmSetpoint Float, lm870CmajorLowOmiAlarmSetpoint Float, lm870CminorHighOmiAlarmSetpoint Float, lm870CminorLowOmiAlarmSetpoint Float, lm870CcurrentValueOmiAlarmSetpoint Float, lm870CstateFlagOmiAlarmSetpoint INTEGER, lm870CminValueOmiAlarmSetpoint Float, lm870CmaxValueOmiAlarmSetpoint Float, lm870CalarmStateOmiAlarmSetpoint INTEGER } -- **************** Digital Parameters *********************** Gx2Lm870CDigitalEntry ::= SEQUENCE { gx2Lm870CDigitalTableIndex INTEGER, lm870ClabelOMIOffsetAlarms DisplayString (SIZE (0..80)), lm870CenumOMIOffsetAlarms DisplayString (SIZE (0..80)), lm870CvalueOMIOffsetAlarms INTEGER, lm870CstateFlagOMIOffsetAlarms INTEGER, lm870ClabelFactoryDefault DisplayString (SIZE (0..80)), lm870CenumFactoryDefault DisplayString (SIZE (0..80)), lm870CvalueFactoryDefault INTEGER, lm870CstateFlagFactoryDefault INTEGER, lm870ClabelOMISetpoint DisplayString (SIZE (0..80)), lm870CenumOMISetpoint DisplayString (SIZE (0..80)), lm870CvalueOMISetpoint INTEGER, lm870CstateFlagOMISetpoint INTEGER } -- **************** Status Parameters ************************************ Gx2Lm870CStatusEntry ::= SEQUENCE { gx2Lm870CStatusTableIndex INTEGER, lm870ClabelBoot DisplayString (SIZE (0..80)), lm870CvalueBoot INTEGER, lm870CstateflagBoot INTEGER, lm870ClabelFlash DisplayString (SIZE (0..80)), lm870CvalueFlash INTEGER, lm870CstateflagFlash INTEGER, lm870ClabelRFOverload DisplayString (SIZE (0..80)), lm870CvalueRFOverload INTEGER, lm870CstateflagRFOverload INTEGER, lm870ClabelRFPower DisplayString (SIZE (0..80)), lm870CvalueRFPower INTEGER, lm870CstateflagRFPower INTEGER, lm870ClabelFactoryDataCRC DisplayString (SIZE (0..80)), lm870CvalueFactoryDataCRC INTEGER, lm870CstateflagFactoryDataCRC INTEGER, lm870ClabelAlarmDataCrc DisplayString (SIZE (0..80)), lm870CvalueAlarmDataCrc INTEGER, lm870CstateflagAlarmDataCrc INTEGER, lm870ClabelModSetDataCRC DisplayString (SIZE (0..80)), lm870CvalueModSetDataCRC INTEGER, lm870CstateflagModSetDataCRC INTEGER, lm870ClabelOptCalDataCRC DisplayString (SIZE (0..80)), lm870CvalueOptCalDataCRC INTEGER, lm870CstateflagOptCalDataCRC INTEGER, lm870ClabelRFCalDataCRC DisplayString (SIZE (0..80)), lm870CvalueRFCalDataCRC INTEGER, lm870CstateflagRFCalDataCRC INTEGER } -- **************** Factory Parameters ************************************* Gx2Lm870CFactoryEntry ::= SEQUENCE { gx2Lm870CFactoryTableIndex INTEGER, lm870CbootControlByte INTEGER, lm870CbootStatusByte INTEGER, lm870Cbank1CRC INTEGER, lm870Cbank2CRC INTEGER, lm870CprgEEPROMByte INTEGER, lm870CfactoryCRC INTEGER, lm870CcalculateCRC INTEGER, lm870ChourMeter INTEGER, lm870CflashPrgCntA INTEGER, lm870CflashPrgCntB INTEGER, lm870CflashBankARev DisplayString (SIZE (0..80)), lm870CflashBankBRev DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2Lm870CAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lm870CAnalogEntry 1} -- New Parameter lm870ClabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2lm870CAnalogEntry 2} lm870CuomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2lm870CAnalogEntry 3} lm870CmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 4} lm870CmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 5} lm870CminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 6} lm870CminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 7} lm870CcurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 8} lm870CstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 9} lm870CminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 10} lm870CmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 11} lm870CalarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2lm870CAnalogEntry 12} -- New Parameter lm870Clabel12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2lm870CAnalogEntry 13} lm870Cuom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2lm870CAnalogEntry 14} lm870CmajorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 15} lm870CmajorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 16} lm870CminorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 17} lm870CminorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 18} lm870CcurrentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 19} lm870CstateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 20} lm870CminValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 21} lm870CmaxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 22} lm870CalarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2lm870CAnalogEntry 23} -- New Parameter lm870ClabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2lm870CAnalogEntry 24} lm870CuomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2lm870CAnalogEntry 25} lm870CmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 26} lm870CmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 27} lm870CminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 28} lm870CminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 29} lm870CcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 30} lm870CstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 31} lm870CminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 32} lm870CmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 33} lm870CalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2lm870CAnalogEntry 34} -- New Parameter lm870ClabelOmiOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the OMI Offset Analog parameter." ::= { gx2lm870CAnalogEntry 35} lm870CuomOmiOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the OMI Offset Analog parameter." ::= { gx2lm870CAnalogEntry 36} lm870CmajorHighOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 37} lm870CmajorLowOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 38} lm870CminorHighOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 39} lm870CminorLowOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 40} lm870CcurrentValueOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the OMI Offset Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 41} lm870CstateFlagOmiOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the OMI Offset Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 42} lm870CminValueOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 43} lm870CmaxValueOmiOffset OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the OMI Offset Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 44} lm870CalarmStateOmiOffset OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the OMI Offset Analog parameter." ::= { gx2lm870CAnalogEntry 45} -- New Parameter lm870ClabelOPTPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2lm870CAnalogEntry 46} lm870CuomOPTPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter.." ::= { gx2lm870CAnalogEntry 47} lm870CmajorHighOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 48} lm870CmajorLowOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 49} lm870CminorHighOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 50} lm870CminorLowOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 51} lm870CcurrentValueOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 52} lm870CstateFlagOPTPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 53} lm870CminValueOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 54} lm870CmaxValueOPTPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 55} lm870CalarmStateOPTPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2lm870CAnalogEntry 56} -- New Parameter lm870ClabelLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2lm870CAnalogEntry 57} lm870CuomLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Analog parameter." ::= { gx2lm870CAnalogEntry 58} lm870CmajorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 59} lm870CmajorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 60} lm870CminorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 61} lm870CminorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 62} lm870CcurrentValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 63} lm870CstateFlagLaserBias OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 64} lm870CminValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 65} lm870CmaxValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 66} lm870CalarmStateLaserBias OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Analog parameter." ::= { gx2lm870CAnalogEntry 67} -- New Parameter lm870ClabelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2lm870CAnalogEntry 68} lm870CuomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter.." ::= { gx2lm870CAnalogEntry 69} lm870CmajorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 70} lm870CmajorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 71} lm870CminorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 72} lm870CminorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 73} lm870CcurrentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 74} lm870CstateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 75} lm870CminValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 76} lm870CmaxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 77} lm870CalarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2lm870CAnalogEntry 78} -- New Parameter lm870ClabelOmiAlarmSetpoint OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the OMI Offset Alarm Setpoint Analog parameter." ::= { gx2lm870CAnalogEntry 79} lm870CuomOmiAlarmSetpoint OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the OMI Offset Alarm Setpoint Analog parameter.." ::= { gx2lm870CAnalogEntry 80} lm870CmajorHighOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 81} lm870CmajorLowOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 82} lm870CminorHighOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 83} lm870CminorLowOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 84} lm870CcurrentValueOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the OMI Offset Alarm Setpoint Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 85} lm870CstateFlagOmiAlarmSetpoint OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the OMI Offset Alarm Setpoint Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CAnalogEntry 86} lm870CminValueOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 87} lm870CmaxValueOmiAlarmSetpoint OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the OMI Offset Alarm Setpoint Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2lm870CAnalogEntry 88} lm870CalarmStateOmiAlarmSetpoint OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the OMI Offset Alarm Setpoint Analog parameter." ::= { gx2lm870CAnalogEntry 89} -- ************************ Digital parameters ********************************** gx2Lm870CDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lm870CDigitalEntry 1} -- New parameter lm870ClabelOMIOffsetAlarms OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the OMI Offset Alarm mode Digital parameter." ::= { gx2lm870CDigitalEntry 2} lm870CenumOMIOffsetAlarms OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the OMI Offset Alarm modeDigital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lm870CDigitalEntry 3} lm870CvalueOMIOffsetAlarms OBJECT-TYPE SYNTAX INTEGER { off(1), on(2), set(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. Note that the value to be read will always be 1 or 2 because the set value (3) is always changed to the on value (2) by the firmware" ::= { gx2lm870CDigitalEntry 4} lm870CstateFlagOMIOffsetAlarms OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the OMI Offset Alarm mode Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CDigitalEntry 5} -- New parameter lm870ClabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Reset to Factory Default Control Digital parameter." ::= { gx2lm870CDigitalEntry 6} lm870CenumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Reste to Factory Default Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lm870CDigitalEntry 7} lm870CvalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2lm870CDigitalEntry 8} lm870CstateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CDigitalEntry 9} -- New parameter lm870ClabelOMISetpoint OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the label of the OMI Setpoint Digital parameter." ::= { gx2lm870CDigitalEntry 10} lm870CenumOMISetpoint OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object represents the Enumeration values possible for the OMI Setpoint Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2lm870CDigitalEntry 11} lm870CvalueOMISetpoint OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object is the current value of the OMI Setpoint parameter." ::= { gx2lm870CDigitalEntry 12} lm870CstateFlagOMISetpoint OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the state of the OMI Setpoint Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CDigitalEntry 13} -- *********** STATUS ***************** gx2Lm870CStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lm870CStatusEntry 1} --New Parameter lm870ClabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2lm870CStatusEntry 2} lm870CvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the boot status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 3} lm870CstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the boot status parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 4} --New Parameter lm870ClabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2lm870CStatusEntry 5} lm870CvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Flash Status parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 6} lm870CstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state current of the the Flash Status parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 7} --New Parameter lm870ClabelRFOverload OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label for the RF Overload Status parameter." ::= { gx2lm870CStatusEntry 8} lm870CvalueRFOverload OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the RF Overload parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 9} lm870CstateflagRFOverload OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the RF Overload parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 10} --New Parameter lm870ClabelRFPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label for the RF Power Status parameter." ::= { gx2lm870CStatusEntry 11} lm870CvalueRFPower OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the RF Power parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 12} lm870CstateflagRFPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the RF Power parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 13} --New Parameter lm870ClabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2lm870CStatusEntry 14} lm870CvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Factory Data CRC parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 15} lm870CstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the the Factory Data CRC parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 16} --New Parameter lm870ClabelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2lm870CStatusEntry 17} lm870CvalueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Alarm Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 18} lm870CstateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the the Alarm Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 19} --New Parameter lm870ClabelModSetDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Settings Data Crc parameter." ::= { gx2lm870CStatusEntry 20} lm870CvalueModSetDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Module Settings Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 21} lm870CstateflagModSetDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the the Module Settings Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 22} --New Parameter lm870ClabelOptCalDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Calibration Data Crc parameter." ::= { gx2lm870CStatusEntry 23} lm870CvalueOptCalDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Optical Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 24} lm870CstateflagOptCalDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the the Optical Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 25} --New Parameter lm870ClabelRFCalDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Calibration Data Crc parameter." ::= { gx2lm870CStatusEntry 26} lm870CvalueRFCalDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the RF Calibration Data Crc parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2lm870CStatusEntry 27} lm870CstateflagRFCalDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the the RF Calibration Data Crc parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2lm870CStatusEntry 28} -- ************ FACTORY DATA **************** gx2Lm870CFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2lm870CFactoryEntry 1} lm870CbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2lm870CFactoryEntry 2} lm870CbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2lm870CFactoryEntry 3} lm870Cbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2lm870CFactoryEntry 4} lm870Cbank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2lm870CFactoryEntry 5} lm870CprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2lm870CFactoryEntry 6} lm870CfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2lm870CFactoryEntry 7} lm870CcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), settings(2), alarm(3), opticalCal(4), rfCal(5) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2lm870CFactoryEntry 8} lm870ChourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2lm870CFactoryEntry 9} lm870CflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2lm870CFactoryEntry 10} lm870CflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2lm870CFactoryEntry 11} lm870CflashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2lm870CFactoryEntry 12} lm870CflashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2lm870CFactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- LM870C Laser Module traps -- ************************************************************************** trapLM870CConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapLMCConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapLMCFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapLMC12vAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapLMCModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Module Temperature goes out of range." ::= 5 trapLMCRFPowerAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapLMCOPTPowerAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapLMCLaserBiasAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapLMCTECCurrentAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapLMCFlashAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 10 trapLMCBankBootAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 11 trapLMCAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 12 trapLMCModSetDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Module Settings CRC is incorrect." ::= 13 trapLMCFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 14 trapLMCResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 15 trapLMCOPCalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Optical Calibration Data CRC is incorrect." ::= 16 trapLMCRFCalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF Calibration Data CRC is incorrect." ::= 17 trapLMCRFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF Overload alarm occurs." ::= 18 trapLMCOMIoffsetAlarm TRAP-TYPE ENTERPRISE gx2Lm870C VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when an OMI Offset alarm occurs." ::= 19 END