All MIBs › NETSCREEN-CHASSIS-MIB
Organization: Juniper Networks, Inc.
Last Updated: 2007-05-08
Category: Hardware Inventory
Description: Monitors hardware chassis components, module presence, fan, power, and temperature on Juniper NetScreen platforms.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is NETSCREEN-CHASSIS-MIB?
NETSCREEN-CHASSIS-MIB is a hardware-monitoring MIB for Juniper NetScreen (ScreenOS) firewall/security appliances, defining objects to monitor the physical chassis's battery, fan, power supply, and temperature status. It is explicitly a hardware-health MIB rather than a configuration or traffic MIB, exposing sensor-style status and threshold data for each monitored component. This MIB is squarely about monitoring hardware status of the device: administrators poll it to detect a failed or degraded fan, an overheating chassis, a power supply fault, or a failing backup battery, all leading indicators of impending appliance failure. As a vendor-specific ScreenOS MIB it has no dependency on IETF standards, though it fits alongside the broader family of NetScreen private MIBs (interface, VPN, zone) covering the same device. It is typically deployed wherever Juniper NetScreen firewall appliances are installed at network edges, in data centers, and branch offices, where NETSCREEN-CHASSIS-MIB SNMP monitoring triggers proactive maintenance alerts before a hardware fault causes an outage.
IPNetwork Monitor allows you to monitor SNMP objects defined in NETSCREEN-CHASSIS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Juniper NetScreen (ScreenOS) firewall/security appliance
Monitoring Examples
An administrator would poll the chassis temperature object to catch a reading climbing beyond the normal operating threshold, which combined with a fan-status object reporting a fault would explain the temperature rise and prompt physical inspection or fan replacement. A power object reporting a failed or absent power supply in a redundant-PSU chassis would trigger an alert even while the unit remains operational on its second supply. Battery status objects would be polled to catch a degraded backup battery before it fails during a power outage, preventing loss of the firewall's real-time clock or configuration state.
What Can Be Monitored
- chassis temperature
- fan operational status
- power supply status
- battery status
Imported Objects
From NETSCREEN-SMI
| netscreen | MODULE-IDENTITY |
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
How to Use in IPNetwork Monitor
Example using sysBatteryStatus OID:
OIDs
RFC description
NetScreen (Juniper) vendor MIB for security appliance chassis hardware monitoring and fan/temperature management.
Start monitoring Juniper NetScreen firewalls with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.