MRV-IN-REACH-CHASSIS-MIB

MIB Reference — IPNetwork Monitor

All MIBsMRV-IN-REACH-CHASSIS-MIB

Category: Hardware Inventory, RMON

Description:

Monitors MRV In-Reach chassis hardware inventory, slots, and module status.

Imported Objects

From BRIDGE-MIB

MacAddress

From MRV-IN-REACH-PRODUCT-DIVISION-MIB

AddressType
HardwareType
IOType
mrvInReachProductDivisionOBJECT-IDENTITY

From RFC-1212

OBJECT-TYPE

From RFC1155-SMI

Counter
Gauge
IpAddress

From RFC1213-MIB

DisplayString

What Is MRV-IN-REACH-CHASSIS-MIB?

MRV-IN-REACH-CHASSIS-MIB is a vendor-specific module for MRV Communications' In-Reach modular console/terminal server chassis, covering physical chassis inventory - slot occupancy, installed module types, and per-module operational status. It is squarely a hardware-inventory/status module: its monitoring value centers on whether a slot's installed module (such as a line card or power supply) is present and operating correctly, which is core hardware-health data. Given its naming alongside MRV-IN-REACH-ETHERNET-MIB and MRV-IN-REACH-CHARACTER-MIB, it likely cross-references those modules' data to build a complete per-slot device picture. It is part of MRV's proprietary In-Reach MIB family, used together with the Ethernet and character-mode companion modules. Typical deployment is data-center/NOC environments using modular MRV In-Reach chassis for out-of-band console access management, where an MRV-IN-REACH-CHASSIS-MIB download gives NOC staff a per-slot view of installed module health.

IPNetwork Monitor allows you to monitor SNMP objects defined in MRV-IN-REACH-CHASSIS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • slot occupancy
  • installed module type
  • module operational status
  • chassis inventory

Supported Devices

  • MRV In-Reach modular console/terminal server chassis

Monitoring Examples

No sample objects were provided in this source excerpt, so specific table or leaf object names can't be honestly cited. Based on the module description, a plausible scenario would be polling a chassis slot table for installed module type and operational status to detect a failed or missing line card, but this can't be grounded in confirmed object names here.

OIDs
OID symbolicOID numericTypeAccessDescription
xChassis1.3.6.1.4.1.33.16
xChassisBasic1.3.6.1.4.1.33.16.1
MAC basicBase802Address1.3.6.1.4.1.33.16.1.1MacAddressread-onlyBase IEEE 802 global address for the chassis.
INT basicSlot1.3.6.1.4.1.33.16.1.2INTEGERread-onlyChassis slot number (slotIndex) of the system whose agent is supplying this MIB.
INT basicSlotNumber1.3.6.1.4.1.33.16.1.3INTEGERread-onlyNumber of slots in the chassis.
MAC basicNewBase802Address1.3.6.1.4.1.33.16.1.4MacAddressread-writeNew base IEEE 802 global address for the chassis. Must be set in conjunction with featType 'changeEthernetAddress' and featKey from the MRV In-Reach System MIB.
xSegment1.3.6.1.4.1.33.16.2
segmentTable1.3.6.1.4.1.33.16.2.1not-accessibleA list of segment entries, one for each segment of each type on the chassis.
segmentEntry1.3.6.1.4.1.33.16.2.1.1not-accessibleValues for a chassis segment.
NET segmentType1.3.6.1.4.1.33.16.2.1.1.1NetworkTyperead-onlyThe segment type.
LET segmentIndex1.3.6.1.4.1.33.16.2.1.1.2Letterread-onlyAn index value that uniquely identifies a segment.
xPort1.3.6.1.4.1.33.16.3
IOT portIOCardType1.3.6.1.4.1.33.16.3.1IOTyperead-onlyThe hardware type of the I/O card in this slot.
SER portIOCardSerialNumber1.3.6.1.4.1.33.16.3.2SerialNumberread-onlyThe MRV In-Reach serial number of the I/O card in this slot.
INT portIOCardOperStatus1.3.6.1.4.1.33.16.3.3INTEGERread-onlyStatus of the I/O card relative to the function card in this slot.
portTable1.3.6.1.4.1.33.16.3.4not-accessibleA list of port entries, one for each port of each type on the slots I/O card.
portEntry1.3.6.1.4.1.33.16.3.4.1not-accessibleValues for an I/O card port.
NET portType1.3.6.1.4.1.33.16.3.4.1.1NetworkTyperead-onlyThe port type.
INT portIndex1.3.6.1.4.1.33.16.3.4.1.2INTEGERread-onlyAn index value that uniquely identifies a port.
xController1.3.6.1.4.1.33.16.4
controllerTable1.3.6.1.4.1.33.16.4.1not-accessibleA list of controller entries, one for each controller of each type on the local system.
controllerEntry1.3.6.1.4.1.33.16.4.1.1not-accessibleValues for a controller.
NET controllerType1.3.6.1.4.1.33.16.4.1.1.1NetworkTyperead-onlyThe controller type.
INT controllerIndex1.3.6.1.4.1.33.16.4.1.1.2INTEGERread-onlyAn index value that uniquely identifies a controller.
OID controllerNetwork1.3.6.1.4.1.33.16.4.1.1.3OBJECT IDENTIFIERread-writeThe instance identifier of the first object in the conceptual row entry for the segment, port, or controller this controller is to use, that is, segmentType, portType or controllerType.
xInterface1.3.6.1.4.1.33.16.5
interfaceTable1.3.6.1.4.1.33.16.5.1not-accessibleA list of interface entries, corresponding to the MIB II Interface group. These are directly equivalent to hardware network controllers, and must be the lowest numbered interfaces on the system.
interfaceEntry1.3.6.1.4.1.33.16.5.1.1not-accessibleValues for an interface.
INT interfaceIndex1.3.6.1.4.1.33.16.5.1.1.1INTEGERread-onlyAn index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
OID interfaceNetwork1.3.6.1.4.1.33.16.5.1.1.2OBJECT IDENTIFIERread-writeThe instance identifier of the first object in the conceptual row entry for the segment, port, or controller this interface is to use, that is, segmentType, portType, or controllerType.
xSlotBootControl1.3.6.1.4.1.33.16.6
slotBootControlTable1.3.6.1.4.1.33.16.6.1not-accessibleA list of slot boot control entries.
slotBootControlEntry1.3.6.1.4.1.33.16.6.1.1not-accessibleValues for a chassis slot.
INT slotBootControlSlot1.3.6.1.4.1.33.16.6.1.1.1INTEGERread-onlyAn index value that uniquely identifies a slot, defined the same as slotIndex.
INT slotBootControlIndex1.3.6.1.4.1.33.16.6.1.1.2INTEGERread-onlyAn index value that uniquely identifies a boot control entry, from 1 to the number of entries for the slot.
INT slotBootControlStatus1.3.6.1.4.1.33.16.6.1.1.3INTEGERread-writeThe status of the entry. Set to 'disabled' to disable the entry.
OID slotBootControlController1.3.6.1.4.1.33.16.6.1.1.4OBJECT IDENTIFIERread-writeThe instance identifier of the first object in the conceptual row entry for the controller this entry selects for bootstrap operation, that is, controllerType. This entry must be compatible with slotBootControlNetwork, including being of the same network type. The value 0.0 indicates default action.
OID slotBootControlNetwork1.3.6.1.4.1.33.16.6.1.1.5OBJECT IDENTIFIERread-writeThe instance identifier of the first object in the conceptual row entry for the segment or port this entry selects for bootstrap operation, that is, segmentType or portType. This entry must be compatible with slotBootControlController, including being of the same network type. The value 0.0 indicates default action.
STR slotBootControlMopFile1.3.6.1.4.1.33.16.6.1.1.6DisplayStringread-writeThe software file name to request for down-line load of the server via MOP or XMOP.
STR slotBootControlInternetFile1.3.6.1.4.1.33.16.6.1.1.7DisplayStringread-writeThe filename to request when loading an image via TFTP.
IP slotBootControlInternetAddress1.3.6.1.4.1.33.16.6.1.1.8IpAddressread-writeThe internet address of the system is to use for itself when loading via TFTP. The value 0.0.0.0 indicates default action.
IP slotBootControlInternetServer1.3.6.1.4.1.33.16.6.1.1.9IpAddressread-writeThe internet address of the server to use when loading an image via TFTP. The value 0.0.0.0 indicates default action.
IP slotBootControlInternetGateway1.3.6.1.4.1.33.16.6.1.1.10IpAddressread-writeThe internet address of the gateway to use when loading an image via TFTP. The value 0.0.0.0 indicates default action.
STR slotBootControlInternetDelimiter1.3.6.1.4.1.33.16.6.1.1.11DisplayStringread-writeThe character separating the load file directory name from the file name.
slotBootControlFlagTable1.3.6.1.4.1.33.16.6.2not-accessibleA list of slot boot control source flag entries.
slotBootControlFlagEntry1.3.6.1.4.1.33.16.6.2.1not-accessibleValues for a boot control flag.
INT slotBootControlFlagLoadBootpTftp1.3.6.1.4.1.33.16.6.2.1.1INTEGERread-writeControl for performing load over BOOTP/TFTP.
INT slotBootControlFlagParamBootpTftp1.3.6.1.4.1.33.16.6.2.1.2INTEGERread-writeControl for performing parameter load over BOOTP/TFTP.
INT slotBootControlFlagDumpBootpTftp1.3.6.1.4.1.33.16.6.2.1.3INTEGERread-writeControl for performing dump over BOOTP/TFTP.
INT slotBootControlFlagLoadTftpDirect1.3.6.1.4.1.33.16.6.2.1.4INTEGERread-writeControl for performing load over direct TFTP.
INT slotBootControlFlagParamTftpDirect1.3.6.1.4.1.33.16.6.2.1.5INTEGERread-writeControl for performing parameter load over direct TFTP.
INT slotBootControlFlagDumpTftpDirect1.3.6.1.4.1.33.16.6.2.1.6INTEGERread-writeControl for performing dump over direct TFTP.
INT slotBootControlFlagLoadLocal1.3.6.1.4.1.33.16.6.2.1.7INTEGERread-writeControl for performing load from a local device.
INT slotBootControlFlagParamLocal1.3.6.1.4.1.33.16.6.2.1.8INTEGERread-writeControl for performing parameter load from a local device.
INT slotBootControlFlagDumpLocal1.3.6.1.4.1.33.16.6.2.1.9INTEGERread-writeControl for performing dump from a local device.
INT slotBootControlFlagLoadMop1.3.6.1.4.1.33.16.6.2.1.10INTEGERread-writeControl for performing load over Digital's MOP.
INT slotBootControlFlagParamMop1.3.6.1.4.1.33.16.6.2.1.11INTEGERread-writeControl for performing parameter load over Digital's MOP.
INT slotBootControlFlagDumpMop1.3.6.1.4.1.33.16.6.2.1.12INTEGERread-writeControl for performing dump over Digital's MOP.
INT slotBootControlFlagLoadXmop1.3.6.1.4.1.33.16.6.2.1.13INTEGERread-writeControl for performing load over MRV In-Reach extended MOP.
INT slotBootControlFlagParamXmop1.3.6.1.4.1.33.16.6.2.1.14INTEGERread-writeControl for performing parameter load over MRV In-Reach extended MOP.
INT slotBootControlFlagDumpXmop1.3.6.1.4.1.33.16.6.2.1.15INTEGERread-writeControl for performing dump over MRV In-Reach extended MOP.
INT slotBootControlFlagLoadRarpTftp1.3.6.1.4.1.33.16.6.2.1.16INTEGERread-writeControl for performing load over RARP/TFTP.
INT slotBootControlFlagParamRarpTftp1.3.6.1.4.1.33.16.6.2.1.17INTEGERread-writeControl for performing parameter load over RARP/TFTP.
INT slotBootControlFlagDumpRarpTftp1.3.6.1.4.1.33.16.6.2.1.18INTEGERread-writeControl for performing dump over RARP/TFTP.
slotBootControlStorageTable1.3.6.1.4.1.33.16.6.3not-accessibleA list of slot boot control Storage entries.
slotBootControlStorageEntry1.3.6.1.4.1.33.16.6.3.1not-accessibleValues for a chassis slot.
INT slotBootControlStorageClientSlot1.3.6.1.4.1.33.16.6.3.1.1INTEGERread-onlyAn index value that uniquely identifies a slot, defined the same as slotIndex.
INT slotBootControlStorageServerSlot1.3.6.1.4.1.33.16.6.3.1.2INTEGERread-onlyAn index value that uniquely identifies the slot in which the Storage record resides, with the same values as slotIndex.
INT slotBootControlStorageStatus1.3.6.1.4.1.33.16.6.3.1.3INTEGERread-onlyThe status of the entry.
CTR slotBootControlStorageFailures1.3.6.1.4.1.33.16.6.3.1.4Counterread-onlyThe number of times a read from or write to a given Storage location failed
xSlot1.3.6.1.4.1.33.16.7
slotTable1.3.6.1.4.1.33.16.7.1not-accessibleA list of slot entries.
slotEntry1.3.6.1.4.1.33.16.7.1.1not-accessibleValues for a chassis slot.
INT slotIndex1.3.6.1.4.1.33.16.7.1.1.1INTEGERread-onlyAn index value that uniquely identifies a slot, in the range 0 to basicSlotNumber, where the value 0 indicates the same slot as basicSlot. As the objects found at instance zero are duplicates, that instance does not appear in responses a get-next, that is, the lowest numbered slotIndex returned by get-next is 1.
INT slotAdminAction1.3.6.1.4.1.33.16.7.1.1.2INTEGERread-writeControl to cause reset of the system in a slot. When read, the value is always 'ready'. Setting to 'reset' or 'resetHold' causes a single attempt to take that action, but does not ensure transition to any particular value of slotOperStatus.
INT slotOperStatus1.3.6.1.4.1.33.16.7.1.1.3INTEGERread-onlyRelative to the chassis, the current operating status of the system in the slot.
GAU slotSecondsSinceReset1.3.6.1.4.1.33.16.7.1.1.4Gaugeread-onlyThe number of seconds since the system in the slot was last reset by hardware or software.
HAR slotHardwareType1.3.6.1.4.1.33.16.7.1.1.5HardwareTyperead-onlyThe type of hardware in the slot.
SER slotHardwareSerialNumber1.3.6.1.4.1.33.16.7.1.1.6SerialNumberread-onlyThe MRV In-Reach serial number of the function card hardware in this slot.
INT slotHardwareRevision1.3.6.1.4.1.33.16.7.1.1.7INTEGERread-onlyThis revision level of the function card hardware in the slot.
IOT slotIOCardType1.3.6.1.4.1.33.16.7.1.1.8IOTyperead-onlyThe hardware type of the I/O card in this slot.
SER slotIOCardSerialNumber1.3.6.1.4.1.33.16.7.1.1.9SerialNumberread-onlyThe MRV In-Reach serial number of the I/O card in this slot.
INT slotIOCardOperStatus1.3.6.1.4.1.33.16.7.1.1.10INTEGERread-onlyStatus of the I/O card relative to the function card in this slot.
INT slotBootstrapFirmwareRevision1.3.6.1.4.1.33.16.7.1.1.11INTEGERread-onlyThe firmware revision level of the bootstrap ROM installed in the system in the slot.
INT slotElementalFirmwareRevision1.3.6.1.4.1.33.16.7.1.1.12INTEGERread-onlyThe firmware revision level of the minimal function ROM (management bus microprocessor) installed in the system in the slot.
INT slotMemorySize1.3.6.1.4.1.33.16.7.1.1.13INTEGERread-onlyThe number of bytes of memory installed in the system in the slot.
GAU slotLedNumber1.3.6.1.4.1.33.16.7.1.1.14Gaugeread-onlyThe number of LEDs on the system in the slot. A value of 0 indicates none, unknown, or status not readable.
OCT slotLedStatus1.3.6.1.4.1.33.16.7.1.1.15OCTET STRINGread-onlyThe status of the LEDs displayed on the front and back of the system in the slot. The first bit is the high-order bit of the first byte of the value, proceeding to the low-order bit, then to then next byte. On the system hardware, the first LED is at the top, left, front, proceeding left to right, top to bottom, and front to back.
MAC slotBase802Address1.3.6.1.4.1.33.16.7.1.1.16MacAddressread-onlyBase IEEE 802 global address for the slot.
IP slotIpAddress1.3.6.1.4.1.33.16.7.1.1.17IpAddressread-onlyAn internet address to which the system in this slot might respond. May be one of many.
INT slotPlus5Status1.3.6.1.4.1.33.16.7.1.1.18INTEGERread-onlyStatus of the +5 volt power to the slot.
INT slotPlus12Status1.3.6.1.4.1.33.16.7.1.1.19INTEGERread-onlyStatus of the +12 volt power to the slot.
INT slotMinus12Status1.3.6.1.4.1.33.16.7.1.1.20INTEGERread-onlyStatus of the -12 volt power to the slot.
GAU slotPlus5Watts1.3.6.1.4.1.33.16.7.1.1.21Gaugeread-onlyTenths of watts of +5 volt power currently drawn by the slot.
GAU slotPlus12Watts1.3.6.1.4.1.33.16.7.1.1.22Gaugeread-onlyTenths of watts of +12 volt power currently drawn by the slot.
GAU slotMinus12Watts1.3.6.1.4.1.33.16.7.1.1.23Gaugeread-onlyTenths of watts of -12 volt power currently drawn by the slot.
INT slotIOCardHardwareVersion1.3.6.1.4.1.33.16.7.1.1.24INTEGERread-onlyVersion number of I/O card in the slot.
INT slotRestoreNVS1.3.6.1.4.1.33.16.7.1.1.25INTEGERread-writeSetting to 'execute' causes the non-volatile parameter storage to be restored from an installed memory card. Setting to 'ready' has no effect.
INT slotDefaultNVS1.3.6.1.4.1.33.16.7.1.1.26INTEGERread-writeSetting to 'execute' causes non-volatile stored parameters to be reset to factory defaults. Setting to 'ready' has no effect.
slotBootTable1.3.6.1.4.1.33.16.7.2not-accessibleA list of slot bootstrap status entries. A given slot has an entry in this table only when slotOperStatus is one of: loadRequested, loading, dumpRequested, dumping, paramRequested, paramLoading
slotBootEntry1.3.6.1.4.1.33.16.7.2.1not-accessibleBootstrap status values for a chassis slot.
INT slotBootIndex1.3.6.1.4.1.33.16.7.2.1.1INTEGERread-onlyAn index value that uniquely identifies a slot, defined the same as slotIndex.
INT slotBootIfIndex1.3.6.1.4.1.33.16.7.2.1.2INTEGERread-onlyAn index value that uniquely identifies the interface in use for bootstrap functions. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
OID slotBootNetwork1.3.6.1.4.1.33.16.7.2.1.3OBJECT IDENTIFIERread-onlyThe instance identifier of the first object in the conceptual row entry for the segment or port this interface is using, that is, segmentType or portType.
INT slotBootProtocol1.3.6.1.4.1.33.16.7.2.1.4INTEGERread-onlyThe protocol in use for bootstrap operation.
MAC slotBoot802Address1.3.6.1.4.1.33.16.7.2.1.5MacAddressread-onlyIEEE 802 global address in use for bootstrap operation.
ADR slotBootAddressType1.3.6.1.4.1.33.16.7.2.1.6AddressTyperead-onlyThe type of network address contained in slotBootAddress.
OCT slotBootAddress1.3.6.1.4.1.33.16.7.2.1.7OCTET STRINGread-onlyThe network address the system in the slot is using to identify itself for bootstrap operation.
ADR slotBootServerAddressType1.3.6.1.4.1.33.16.7.2.1.8AddressTyperead-onlyThe type of network address contained in slotBootServerAddress.
OCT slotBootServerAddress1.3.6.1.4.1.33.16.7.2.1.9OCTET STRINGread-onlyThe network address of the system supplying bootstrap services to the system in the slot.
IP slotBootGatewayAddress1.3.6.1.4.1.33.16.7.2.1.10IpAddressread-onlyThe internet address of the router in use for bootstrap operation.
STR slotBootFileName1.3.6.1.4.1.33.16.7.2.1.11DisplayStringread-onlyThe full name of the file in use for bootstrap operation.
GAU slotBootBlockNumber1.3.6.1.4.1.33.16.7.2.1.12Gaugeread-onlyThe current block number being transferred for bootstrap operation, zero if unknown or not applicable.
OCT slotBootCrashCode1.3.6.1.4.1.33.16.7.2.1.13OCTET STRINGread-onlyIf slotOperStatus is dumpRequested or dumping, a code number to identify the crash reason; otherwise zero length.
slotControllerTable1.3.6.1.4.1.33.16.7.3not-accessibleA list of controller entries, one for each controller of each type in each slot.
slotControllerEntry1.3.6.1.4.1.33.16.7.3.1not-accessibleValues for a controller.
NET slotControllerType1.3.6.1.4.1.33.16.7.3.1.1NetworkTyperead-onlyThe controller type.
INT slotControllerIndex1.3.6.1.4.1.33.16.7.3.1.2INTEGERread-onlyAn index value that uniquely identifies a controller.
OID slotControllerNetwork1.3.6.1.4.1.33.16.7.3.1.3OBJECT IDENTIFIERread-onlyThe instance identifier of the first object in the conceptual row entry for the segment or port this controller is to use, that is, segmentType or portType.
xPowerSupply1.3.6.1.4.1.33.16.8
powerSupplyTable1.3.6.1.4.1.33.16.8.1not-accessibleA list of power supply entries.
powerSupplyEntry1.3.6.1.4.1.33.16.8.1.1not-accessibleValues for a chassis power supply.
INT powerSupplyIndex1.3.6.1.4.1.33.16.8.1.1.1INTEGERread-onlyAn index value that uniquely identifies a power supply, in the range 1 to the number of power supply slots in the chassis.
INT powerSupplyAdminAction1.3.6.1.4.1.33.16.8.1.1.2INTEGERread-writeControl to cause reset of the power supply. When read, the value is always 'ready'. Setting to 'reset' or 'resetHold' causes a single attempt to take that action, but does not ensure transition to any particular value of powerSupplyRedundancyStatus.
INT powerSupplyFirmwareVersion1.3.6.1.4.1.33.16.8.1.1.3INTEGERread-onlyVersion number of power supply firmware.
INT powerSupplyRedundancyStatus1.3.6.1.4.1.33.16.8.1.1.4INTEGERread-onlyThe current redundancy status of the power supply.
INT powerSupplyPlus5Status1.3.6.1.4.1.33.16.8.1.1.5INTEGERread-onlyStatus of the +5 volt power from the power supply.
INT powerSupplyPlus12Status1.3.6.1.4.1.33.16.8.1.1.6INTEGERread-onlyStatus of the +12 volt power from the power supply.
INT powerSupplyMinus12Status1.3.6.1.4.1.33.16.8.1.1.7INTEGERread-onlyStatus of the -12 volt power from the power supply.
INT powerSupplyThermalWarningStatus1.3.6.1.4.1.33.16.8.1.1.8INTEGERread-onlyThe current thermal warning status of the power supply.
INT powerSupplyThermalShutdownStatus1.3.6.1.4.1.33.16.8.1.1.9INTEGERread-onlyThe current thermal shutdown status of the power supply.
INT powerSupplyFanStatus1.3.6.1.4.1.33.16.8.1.1.10INTEGERread-onlyThe current status of the power supply's fan.
INT powerSupplyHardwareInhibitStatus1.3.6.1.4.1.33.16.8.1.1.11INTEGERread-onlyThe current status of the power supply's hardware inhibit.
INT powerSupplyPlus5History1.3.6.1.4.1.33.16.8.1.1.12INTEGERread-onlyHistory of the +5 volt power from the power supply.
INT powerSupplyPlus12History1.3.6.1.4.1.33.16.8.1.1.13INTEGERread-onlyHistory of the +12 volt power from the power supply.
INT powerSupplyMinus12History1.3.6.1.4.1.33.16.8.1.1.14INTEGERread-onlyHistory of the -12 volt power from the power supply.
INT powerSupplyThermalWarningHistory1.3.6.1.4.1.33.16.8.1.1.15INTEGERread-onlyThe thermal warning history of the power supply.
INT powerSupplyThermalShutdownHistory1.3.6.1.4.1.33.16.8.1.1.16INTEGERread-onlyThe thermal shutdown history of the power supply.
INT powerSupplyFanHistory1.3.6.1.4.1.33.16.8.1.1.17INTEGERread-onlyThe status history of the power supply's fan.
INT powerSupplyHardwareInhibitHistory1.3.6.1.4.1.33.16.8.1.1.18INTEGERread-onlyThe status history of the power supply's hardware inhibit.
GAU powerSupplyPlus5Volts1.3.6.1.4.1.33.16.8.1.1.19Gaugeread-onlyIn hundredths, volts of +5 volt power currently provided by the power supply. A value of 0 indicates unknown.
GAU powerSupplyPlus12Volts1.3.6.1.4.1.33.16.8.1.1.20Gaugeread-onlyIn hundredths, volts of +12 volt power currently provided by the power supply. A value of 0 indicates unknown.
GAU powerSupplyMinus12Volts1.3.6.1.4.1.33.16.8.1.1.21Gaugeread-onlyIn hundredths, volts of -12 volt power currently provided by the power supply. A value of 0 indicates unknown.
GAU powerSupplyWatts1.3.6.1.4.1.33.16.8.1.1.22Gaugeread-onlyWatts of power currently drawn from this power supply. A value of 0 indicates unknown.
GAU powerSupplyWattsMax1.3.6.1.4.1.33.16.8.1.1.23Gaugeread-onlyMaximum watts of power available from this power supply. A value of 0 indicates unknown.
GAU powerSupplyChassisWatts1.3.6.1.4.1.33.16.8.1.1.24Gaugeread-onlyTotal watts of power currently drawn by the entire chassis. A value of 0 indicates unknown.
GAU powerSupplyChassisWattsMax1.3.6.1.4.1.33.16.8.1.1.25Gaugeread-onlyTotal maximum watts of power available from all the power supplies in the chassis. A value of 0 indicates unknown.
INT powerSupplyHardwareType1.3.6.1.4.1.33.16.8.1.1.26INTEGERread-onlyThe type of power supply.
xFirmwareUpdate1.3.6.1.4.1.33.16.9
firmwareUpdateTable1.3.6.1.4.1.33.16.9.1not-accessibleTable of descriptive and status information concerning the writing of firmware to a target I/O card.
firmwareUpdateEntry1.3.6.1.4.1.33.16.9.1.1not-accessibleAn entry in the table concerning the writing of firmware to a target I/O card.
INT firmwareUpdateSlotIndex1.3.6.1.4.1.33.16.9.1.1.1INTEGERread-onlyThis variable identifies the slot to which is to be the target of the firmware update.
STR firmwareUpdateDefaultFileName1.3.6.1.4.1.33.16.9.1.1.2DisplayStringread-onlyThis variable when read will obtain the default file name from the target.
STR firmwareUpdateFileName1.3.6.1.4.1.33.16.9.1.1.3DisplayStringread-writeThis variable contains the name of the file to be read from the flash memory card and written to the target.
INT firmwareUpdateStatus1.3.6.1.4.1.33.16.9.1.1.4INTEGERread-writeThis variable is used to start the update process. The agent always 'ready' for this value. Setting this value to 'execute' causes the agent to write the file specified by firmwareUpdateFileName to be written to the taget. Setting this value to 'execute' when firmwareUpdateFileName has not been written or when firmwareUpdateState is 'writing' causes bad value to be returned.
INT firmwareUpdateState1.3.6.1.4.1.33.16.9.1.1.5INTEGERread-onlyThis variable indicates the current state of firmware update, 'idle' indicates that firmware update may be initiated, and 'writing' indicates that an update is in process.
INT firmwareUpdateCompletionStatus1.3.6.1.4.1.33.16.9.1.1.6INTEGERread-onlyThis variable indicates the completion status of the the last firmware update attempt. 'none' indicates that no firmware update has yet been attempted.
INT firmwareUpdateMethod1.3.6.1.4.1.33.16.9.1.1.7INTEGERread-writeThis variable indicates the method of update of the firmware update attempt.

RFC description

Monitors MRV In-Reach network equipment chassis, slots, and interfaces on Network 9000 platforms.

Start monitoring MRV In-Reach modular console/terminal server chassis with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download MRV-IN-REACH-CHASSIS-MIB