NETSCREEN-CHASSIS-MIB :: sysBatteryStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NETSCREEN-CHASSIS-MIB › sysBatteryStatus

sysBatteryStatus

Module: NETSCREEN-CHASSIS-MIB

OID (symbolic): NETSCREEN-CHASSIS-MIB::sysBatteryStatus

OID (numeric): 1.3.6.1.4.1.3224.21.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Information describing the installed Battery and its status: 1. Good 2. Error

What is sysBatteryStatus?

This object reports the health status of the chassis's backup battery, used to retain settings like the real-time clock during a power loss: 1 for good, 2 for error. Admins monitor this to catch a failing battery before it causes clock drift or configuration loss during a power interruption. For example, sysBatteryStatus reporting 2 (error) would prompt scheduling a battery replacement before the next planned power outage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3224.21.3
snmpwalk -v2c -c public <target> NETSCREEN-CHASSIS-MIB::sysBatteryStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3224.21.3.1
snmpget -v2c -c public <target> NETSCREEN-CHASSIS-MIB::sysBatteryStatus.1

Start monitoring Juniper NetScreen firewalls with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NETSCREEN-CHASSIS-MIB::sysBatteryStatus OID value, configure state conditions and alerts, and monitor any Juniper NetScreen firewalls from a single console.

How to Use in IPNetwork Monitor

Select a Juniper NetScreen firewall as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sysBatteryStatus into the Find box to locate it in the OID tree, then select it and click OK. It reports the information describing the installed Battery and its status: 1. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3224netscreenNETSCREEN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3224.21netscreenChassisNETSCREEN-CHASSIS-MIB
1.3.6.1.4.1.3224.21.3sysBatteryStatusNETSCREEN-CHASSIS-MIB