Type: INTEGER

Access: read-only

Description: The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (PrtCapacityUnitTC) of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by management requests; otherwise, the value may be written (by a Remote Control Panel or a Management Application). The value (-1) means other and specifically indicates that the sub-unit places no restrictions on this parameter. The value (-2) means unknown. The value (-3) means that the printer knows that there remains capacity for at least one unit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional information: Replaces PML NOT-READY-OUTBIN-FULL and STATUS-OUTBIN-FULL. The values reported for output sub-unit 1 (face-down, top bin) will be either (-3) if it is not full or (0) if it is full.Output sub-unit 2 (face-up, left side bin) does not have any sensing, so it will always report unknown (-2).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5
snmpwalk -v2c -c public <target> LaserJet-Series8100-MIB::prtoutputremainingcapacity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5.1
snmpget -v2c -c public <target> LaserJet-Series8100-MIB::prtoutputremainingcapacity.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> prtoutputremainingcapacity.1

Start monitoring HP LaserJet 8100 series printer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LaserJet-Series8100-MIB::prtoutputremainingcapacity OID value, configure state conditions and alerts, and monitor any HP LaserJet 8100 series printer from a single console.

OID Breakdown

Upper-level ancestors (16 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9net_peripheralCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4netdmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2dmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.2printmibCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.2.9prtOutputCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.2.9.2prtOutputTableCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1prtOutputEntryCLJ8500-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5prtoutputremainingcapacityLaserJet-Series8100-MIB