| OID symbolic | OID numeric | Type | Access | Description |
| lumOcmMIBModule | 1.3.6.1.4.1.8708.1.1.33 | | | The optical control interface MIB.
- General
- Monitor interfaces
Note that, every time a get operation is performed and both ports are set
to admin status up, the switch will switch to update both ports. (unless
commissioning mode) The guaranteed durability of switching is 10 million times.
That means, if you switch (perform a get operation) more than every 50 second,
product lifetime of 15 years can not be guaranteed. |
| lumOcmConfs | 1.3.6.1.4.1.8708.2.33.1 | | | |
| lumOcmGroups | 1.3.6.1.4.1.8708.2.33.1.1 | | | |
| ocmGeneralGroup | 1.3.6.1.4.1.8708.2.33.1.1.1 | | | The general objects. |
| ocmIfGroup | 1.3.6.1.4.1.8708.2.33.1.1.2 | | | The ocm interface objects. |
| ocmChannelGroup | 1.3.6.1.4.1.8708.2.33.1.1.3 | | | The ocm channel objects. |
| ocmIfGroupV2 | 1.3.6.1.4.1.8708.2.33.1.1.4 | | | The ocm interface objects. |
| ocmIfGroupV3 | 1.3.6.1.4.1.8708.2.33.1.1.5 | | | The ocm interface objects. |
| ocmChannelGroupV2 | 1.3.6.1.4.1.8708.2.33.1.1.6 | | | The ocm channel objects. |
| ocmIfGroupV4 | 1.3.6.1.4.1.8708.2.33.1.1.7 | | | The ocm interface objects. |
| lumOcmCompl | 1.3.6.1.4.1.8708.2.33.1.2 | | | |
| lumOcmBasicComplV1 | 1.3.6.1.4.1.8708.2.33.1.2.1 | | | Basic implementation requirements for the OCM MIB V1. |
| lumOcmBasicComplV2 | 1.3.6.1.4.1.8708.2.33.1.2.2 | | | Basic implementation requirements for the OCM MIB V2 (14.0). |
| lumOcmBasicComplV3 | 1.3.6.1.4.1.8708.2.33.1.2.3 | | | Basic implementation requirements for the OCM MIB V2 (23.0). |
| lumOcmBasicComplV4 | 1.3.6.1.4.1.8708.2.33.1.2.4 | | | Basic implementation requirements for the OCM MIB V2 (30.0). |
| lumOcmBasicComplV5 | 1.3.6.1.4.1.8708.2.33.1.2.5 | | | Basic implementation requirements for the OCM MIB V2 (31.0). |
| lumOcmMinimalGroups | 1.3.6.1.4.1.8708.2.33.1.3 | | | |
| lumOcmMinimalCompl | 1.3.6.1.4.1.8708.2.33.1.4 | | | |
| lumOcmMinimalComplV1 | 1.3.6.1.4.1.8708.2.33.1.4.1 | | | Minimal implementation requirements for the OCM MIB V1. |
| lumOcmMIBObjects | 1.3.6.1.4.1.8708.2.33.2 | | | |
| ocmGeneral | 1.3.6.1.4.1.8708.2.33.2.1 | | | |
| DAT ocmGeneralLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.1.1 | DateAndTime | read-only | The time when the configuration of the MIB
was last changed. |
| DAT ocmGeneralStateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.1.2 | DateAndTime | read-only | The time when the state of the MIB was last
changed. |
| U32 ocmGeneralOcmIfTableSize | 1.3.6.1.4.1.8708.2.33.2.1.3 | Unsigned32 | read-only | Size of table |
| U32 ocmGeneralOcmChannelTableSize | 1.3.6.1.4.1.8708.2.33.2.1.4 | Unsigned32 | read-only | Size of table |
| ocmIfList | 1.3.6.1.4.1.8708.2.33.2.2 | | | |
| ocmIfTable | 1.3.6.1.4.1.8708.2.33.2.2.1 | | not-accessible | The interface list. |
| ocmIfEntry | 1.3.6.1.4.1.8708.2.33.2.2.1.1 | | not-accessible | An entry in the interface list. |
| U32 ocmIfIndex | 1.3.6.1.4.1.8708.2.33.2.2.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each entry. |
| STR ocmIfName | 1.3.6.1.4.1.8708.2.33.2.2.1.1.2 | MgmtNameString | read-only | The management name of the interface, for
example 'ocm:1:2:1', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
ocm:s:s:p - Optical channel module interface |
| STR ocmIfDescr | 1.3.6.1.4.1.8708.2.33.2.2.1.1.3 | DisplayString | read-write | User configurable label. |
| SUB ocmIfSubrack | 1.3.6.1.4.1.8708.2.33.2.2.1.1.4 | SubrackNumber | read-create | The number of the subrack where the interface
is located. |
| SLO ocmIfSlot | 1.3.6.1.4.1.8708.2.33.2.2.1.1.5 | SlotNumber | read-create | The number of the slot where the interface is
located. |
| POR ocmIfRxPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.6 | PortNumber | read-create | The number of the port where the RX-side of
the interface is located. |
| U32 ocmIfInvPhysIndexOrZero | 1.3.6.1.4.1.8708.2.33.2.2.1.1.7 | Unsigned32 | read-only | The row in the invPhysTable for this interface.
Set to 0 if not known. |
| NUM ocmIfAdminStatus | 1.3.6.1.4.1.8708.2.33.2.2.1.1.8 | BoardOrInterfaceAdminStatus | read-write | The administrative state for the interface.
down - The interface should be inactive.
service - The interface is activated but alarms
are suppressed. Intended for use during service
or re-configuration. When service is concluded
adminStatus should be set to 'up' again.
up - The interface should be activated when
it becomes available. Alarms are not suppressed. |
| NUM ocmIfOperStatus | 1.3.6.1.4.1.8708.2.33.2.2.1.1.9 | BoardOrInterfaceOperStatus | read-only | The operational state for the interface.
notPresent - The physical resources are not
available.
down - The interface is de-activated or the are
faults preventing it from going to the 'up'-state.
up - The interface is operational. |
| I32 ocmIfPowerThreshold | 1.3.6.1.4.1.8708.2.33.2.2.1.1.12 | Integer32 | read-create | The threshold for power levels. If the measured
power level is below the threshold, it is regarded
as no signal.
For OCM8p:
Default -13dBm
Range -35 to 100dBm
For OCM2p: |
| DAT ocmIfUpdateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.2.1.1.13 | DateAndTime | read-only | The time when the last measurement was done. |
| SUB ocmIfConnectedSubrack | 1.3.6.1.4.1.8708.2.33.2.2.1.1.14 | SubrackNumber | read-create | The number of the subrack where the connected
interface is located. (0 is not valid) |
| SLO ocmIfConnectedSlot | 1.3.6.1.4.1.8708.2.33.2.2.1.1.15 | SlotNumber | read-create | The number of the slot where the connected
interface is located. (not possible to set 0, 1,
19-22, oa/roadm can not be placed in those slots) |
| POR ocmIfConnectedPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.16 | PortNumber | read-create | The number of the connected port.
(the tx port number).
1 or 3 for OA,
5 for 1x2ROADM/100G/50G,
9 for 1x4ROADM/100G,ROADM1x4f,
17 for 1x8ROADM/50G,
19 for ROADM1x9f,
1 for OA26C,
5 for OARAED21HG
81 for MDU40.
and 1 to 82 for other boards. |
| POR ocmIfActivePort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.17 | PortNumber | read-only | The number of the active port.
Only valid when commissioning mode. |
| INT ocmIfControlMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.18 | INTEGER | read-only | What mode the ocm is in.
normal - the switch toggle every hour
and measure both ports.
commissioning - the switch is set to one active
port and measurement is made continuously on this port.
After 15 minutes it will change back to normal mode.
Note that it is not possible to get updated
values on port that is not chosen as active during
commissioning mode. |
| STR ocmIfReferenceTime | 1.3.6.1.4.1.8708.2.33.2.2.1.1.21 | DisplayString | read-create | Time where reference values were saved. |
| FAU ocmIfSwitchFailure | 1.3.6.1.4.1.8708.2.33.2.2.1.1.22 | FaultStatus | read-only | Switch failure.
A: The switch is stuck and it is not possible
to change port. It is not sure if it the values
comes from the expected port.
D: The switch works as expected. |
| FAU ocmIfDataSourceNotDefined | 1.3.6.1.4.1.8708.2.33.2.2.1.1.23 | FaultStatus | read-only | Data source not defined,
A: No connected slot, connected subrack
nor connected port is defined.
D: Connected slot, connected subrack and
connected port is ok. |
| FAU ocmIfCommissioningMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.24 | FaultStatus | read-only | Data source not defined,
A: Commissioning mode is used
D: Normal mode |
| FAU ocmIfModuleFailure | 1.3.6.1.4.1.8708.2.33.2.2.1.1.25 | FaultStatus | read-only | The module HW has detected a failure.
A: The module has failed
D: The module is OK again |
| STR ocmIfConfigurationCommand | 1.3.6.1.4.1.8708.2.33.2.2.1.1.26 | CommandString | read-only | Select which control mode to use.
normal - the switch toggle every hour
and measure both ports.
commissioning - the switch is set to one
port while adjusting surrounding boards. |
| STR ocmIfChangeConnectedPort | 1.3.6.1.4.1.8708.2.33.2.2.1.1.27 | CommandString | read-only | Select which monitor port that is connected
to this ocm port. |
| STR ocmIfSaveReference | 1.3.6.1.4.1.8708.2.33.2.2.1.1.28 | CommandString | read-only | Save current measurement as reference values |
| I32 ocmIfPowerOffset | 1.3.6.1.4.1.8708.2.33.2.2.1.1.29 | Integer32 | read-create | An offset value added to all power levels to get
an accurate presentation of channel powers at the line
port.
Generally offset values depends upon board type connected.
oa - 20.0
roadm - 17.0
oa26c - 20.0
mdu40 - 20.0
other - 20.0
oaraed21hg - 20.0
oaraed20lg - 20.0
OA boards have more accurate values for power offset
named Monitor port insertion loss visible in the OA
interface.
Note however that the reference power level values
are not affected by a change of this offset. A new
reference calculation should be made after a change. |
| INT ocmIfConnectedBoardType | 1.3.6.1.4.1.8708.2.33.2.2.1.1.30 | INTEGER | read-create | What board type that is connected to the ocm.
The power offset default value is changed
based on the chosen board type.
Please note that this function is not
applicable for mdu40lite boards. |
| STR ocmIfChangeConnectedBoardType | 1.3.6.1.4.1.8708.2.33.2.2.1.1.31 | CommandString | read-only | Select board type for the monitor port connected
to this ocm port. |
| I32 ocmIfMaxPowerLevel | 1.3.6.1.4.1.8708.2.33.2.2.1.1.32 | Integer32 | read-only | The maximum received power level for this port
in units of 0.1 dBm. |
| I32 ocmIfMinPowerLevel | 1.3.6.1.4.1.8708.2.33.2.2.1.1.33 | Integer32 | read-only | The minimum received power level for this port
in units of 0.1 dBm. |
| I32 ocmIfDeltaPower | 1.3.6.1.4.1.8708.2.33.2.2.1.1.34 | Integer32 | read-only | The difference between the maximum and the minimum
received power level for this port in units of 0.1 dBm. |
| STR ocmIfChangePowerThreshold | 1.3.6.1.4.1.8708.2.33.2.2.1.1.35 | CommandString | read-only | Select the power threshold for this ocm port.
If the measured power level is below the threshold, it
is regarded as no signal. |
| STR ocmIfChangePowerOffset | 1.3.6.1.4.1.8708.2.33.2.2.1.1.36 | CommandString | read-only | Select the power offset for this ocm port.
The power offset is a value added to all power levels to get
an accurate presentation of channel powers at the line port. |
| I32 ocmIfPowerOffsetAdjustment | 1.3.6.1.4.1.8708.2.33.2.2.1.1.37 | Integer32 | read-only | An offset adjustment added to the power offset to
mitigate the effects of differences between actual
power measured at the OCM and the configured power
offset value.
This adjustment allows the optical control loop to
regulate with better precision. |
| INT ocmIfSpacingMode | 1.3.6.1.4.1.8708.2.33.2.2.1.1.38 | INTEGER | read-create | Spacing mode is configured for monitoring channel power
with the channel spacing of 50GHz.
spacing50GHz: interface with channels in 50 GHz intervals |
| FAU ocmIfHighInputPower | 1.3.6.1.4.1.8708.2.33.2.2.1.1.39 | FaultStatus | read-only | The OCM module has detected a high input power.
A: OCM module has dectected high input power (above 20dBm)
on particular port.
D: Optical input power is within the limit (below 20dBm). |
| ocmChannelList | 1.3.6.1.4.1.8708.2.33.2.3 | | | |
| ocmChannelTable | 1.3.6.1.4.1.8708.2.33.2.3.1 | | not-accessible | The channel list. |
| ocmChannelEntry | 1.3.6.1.4.1.8708.2.33.2.3.1.1 | | not-accessible | An entry in the channel list. |
| U32 ocmChannelIndex | 1.3.6.1.4.1.8708.2.33.2.3.1.1.1 | Unsigned32 | read-only | An arbitrary index assigned to each entry. |
| STR ocmChannelName | 1.3.6.1.4.1.8708.2.33.2.3.1.1.2 | MgmtNameString | read-only | The management name of the interface, for
example 'ocm:1:2:1', where the first number
indicates sub-rack, the second slot number and
the third is the port number.
Examples:
ocm:s:s:p - Optical channel module interface |
| LAM ocmChannelFrequency | 1.3.6.1.4.1.8708.2.33.2.3.1.1.3 | LambdaFrequency | read-create | Freqency in hundreds of GHz (0.01 GHz). |
| I32 ocmChannelPowerLevel | 1.3.6.1.4.1.8708.2.33.2.3.1.1.4 | Integer32 | read-only | The received power level in units of 0.1 dBm. |
| DAT ocmChannelUpdateLastChangeTime | 1.3.6.1.4.1.8708.2.33.2.3.1.1.5 | DateAndTime | read-only | Time when last measurement was done. |
| U32 ocmChannelOcmRefIfIndex | 1.3.6.1.4.1.8708.2.33.2.3.1.1.6 | Unsigned32 | read-only | The SNMP-index of the OCM i/f object related to this
object. |
| I32 ocmChannelReferencePowerLevel | 1.3.6.1.4.1.8708.2.33.2.3.1.1.7 | Integer32 | read-create | The reference power level in units of 0.1 dBm. |
| STR ocmChannelReferenceTime | 1.3.6.1.4.1.8708.2.33.2.3.1.1.8 | DisplayString | read-create | Time where reference values were saved. |
| STR ocmChannelSaveReference | 1.3.6.1.4.1.8708.2.33.2.3.1.1.9 | CommandString | read-only | Save current measurement as reference values |
| lumentisOcmNotifications | 1.3.6.1.4.1.8708.2.33.2.4 | | | |