All MIBs › ERI-DNX-NEST-SYS-MIB
Organization: Eastern Research, Inc.
Last Updated: 2003-07-17
Category: Domain: WAN/TDM, Vendor: ERI
Description: Eastern Research Inc. DNX nest system administration MIB for chassis, slot, and system-level management of DNX-88/DNX-11.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ERI-DNX-NEST-SYS-MIB?
This is Eastern Research Inc.'s enterprise MIB for administering the "nest" chassis system of the DNX-88/DNX-11 multiplexer platforms, managing slot, device, and redundancy configuration. It exposes a slot configuration table capturing configured vs. actual device type per slot, device operational state, alarm level, device name/version, and redundancy role, plus objects for software upgrade and nest expansion administration. This is a clear hardware status monitoring MIB: an operator can check slotDeviceState and slotAlarmLevel per slotNbr to detect a failed or alarming card, compare slotConfigDeviceType against slotActualDeviceType to catch a mismatched/incorrectly inserted module, and track slotDeviceRedundancy to confirm redundant slot pairing is intact. No explicit dependency on other MIBs is indicated; it appears self-contained. It is typically deployed in Eastern Research DNX-88/DNX-11 telecom multiplexer chassis used in carrier/enterprise transport networks. Network engineers evaluating or troubleshooting this functionality can download the ERI-DNX-NEST-SYS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ERI-DNX-NEST-SYS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Eastern Research Inc. DNX-88/DNX-11 nest multiplexer chassis
Monitoring Examples
Polling slotConfigTable for slotDeviceState and slotAlarmLevel per slotNbr identifies a slot reporting a fault or alarm condition, while comparing slotConfigDeviceType to slotActualDeviceType reveals a mismatch, such as a technician inserting the wrong card type into a slot. slotDeviceVersion shows the installed card's software/firmware version, useful for confirming all nest modules are running a consistent, supported release before a maintenance window.
What Can Be Monitored
- per-slot device operational state
- per-slot alarm level
- configured vs. actual device type mismatch
- device firmware/software version
- slot redundancy role
This MIB depends on
Related MIBs
Imported Objects
From ERI-DNX-SMC-MIB
| DecisionType | |
| NestSlotAddress | |
| UnsignedInt | |
| database | OBJECT-IDENTITY |
| devices | OBJECT-IDENTITY |
| dnx | OBJECT-IDENTITY |
| dnxTrapEnterprise | OBJECT-IDENTITY |
| sysMgr | OBJECT-IDENTITY |
| trapSequence | OBJECT-TYPE |
From ERI-ROOT-SMI
| eriMibs | OBJECT-IDENTITY |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using slotMiscState OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF slotConfigTrap | 1.3.6.1.4.1.644.2.4.0.5 | This trap is used to notify a NMS that a user has updated the configuration for a given slot entry. | ||
| NTF ndrGroupStatusTrap | 1.3.6.1.4.1.644.2.4.0.8 | This trap is used to notify a NMS that due to an alarm condition or system state change, the N+1 Redundancy Groups have been modified. This means the one or more devices have been removed or added to the actual N+1 Redundancy Groups and this will affect which cards will be protected (switched) in the event of a failure. | ||
| NTF nestConfigTrap | 1.3.6.1.4.1.644.2.4.0.9 | This trap is used to notify a NMS that a user has updated the configuration for a given nest entry. | ||
| NTF dbSyncProgressTrap | 1.3.6.1.4.1.644.2.4.0.12 | This trap is used to notify a NMS that the system has either started or just completed the Database synchronization process. | ||
| slotConfigTable | 1.3.6.1.4.1.644.2.4.1.3 | not-accessible | A list of the device cards in this node with the static and dynamic type information. The maximum number of entries depends on the number of slots in the system plus 3 default entries for the system manager cards and the Protection Switch. | |
| slotConfigEntry | 1.3.6.1.4.1.644.2.4.1.3.1 | not-accessible | The conceptual row of the Slot Configuration table. A row in this table can not be created or deleted. A row in this table can be modified by providing valid values for either the Slot Name, Configured Device Type, Device Redundancy, or Slot Command Status. Deleting the Slot Configuration using the Slot Command Status value of 'delete-slot-config' will result in the removal of all configured connections associated with that slot number. The slotConfigCmdStatus field must be included as a variable in a SET PDU for the action to take effect. If the slotConfigCmdStatus is missing from the SET PDU, the GET RESPONSE will contain the SNMP error status of 'genErr' for and an error index equal to the last variable. | |
| INT slotNbr | 1.3.6.1.4.1.644.2.4.1.3.1.1 | INTEGER | read-only | The slot number in the node. |
| DNX slotConfigDeviceType | 1.3.6.1.4.1.644.2.4.1.3.1.2 | DnxSlotDeviceType | read-write | This is the slot type configured by the user. The value, slot(0) is the default type for an unconfigured device. If slot(0) is used in a Set Request, the agent will return an error status of 'badValue'. The slot entries representing the System Manager Cards and the Protection Switch device cannot be used in a Set Request since their device type is static. |
| DNX slotActualDeviceType | 1.3.6.1.4.1.644.2.4.1.3.1.3 | DnxSlotDeviceType | read-only | This is the actual slot type sent back by the card. |
| DNX slotDeviceState | 1.3.6.1.4.1.644.2.4.1.3.1.4 | DnxSlotDeviceState | read-only | The current machine state of the device. not-present (0) Indicates no hardware detected in the slot. online (1) Device is present and is considered primary operational. offline (2) Device is present but currently not operational. disabled (3) Applies to the Protection Switch box if system cannot support redundancy. standby (4) Device is present but considered as secondary. defective (5) Device is present but could not be activated. bus-error (6) Device is present and reporting a bus connection error. out-of-serv (7) Operator has placed device in Out of Service mode. |
| INT slotAlarmLevel | 1.3.6.1.4.1.644.2.4.1.3.1.5 | INTEGER | read-only | The current slot device alarm condition level that indicates it's severity. |
| STR slotDeviceName | 1.3.6.1.4.1.644.2.4.1.3.1.6 | DisplayString | read-write | The user defined name for this slot/device. |
| STR slotDeviceVersion | 1.3.6.1.4.1.644.2.4.1.3.1.7 | DisplayString | read-only | The software version release identification number for this device. |
| INT slotDeviceRedundancy | 1.3.6.1.4.1.644.2.4.1.3.1.8 | INTEGER | read-write | The configured N+1 Redundancy state of the device. The slot entries representing the System Manager Cards and the Protection Switch device cannot be used in a Set Request since N+1 Redundancy does not apply to them. disable (0) Device is not configured as part of the Redundancy Group. enable (1) Device is configured as part of the Redundancy Group. n/a (2) Device does not support Redundancy. |
| INT slotMiscStateEx | 1.3.6.1.4.1.644.2.4.1.3.1.9 | INTEGER | read-only | The current slot/device miscellaneous state conditions. none (0) no misc condition errors (1) errors reported on device test (2) device is in test mode errors-test (3) errors reported on device while in test mode clockSrc (4) device is the source for the system clock errors-clockSrc (5) device is the source for the system clock and errors found test-clockSrc (6) device is the source for the system clock and is in test mode errors-test-clockSrc (7) device is the source for the system clock and is in test mode and errors were found |
| INT slotConfigCmdStatus | 1.3.6.1.4.1.644.2.4.1.3.1.10 | INTEGER | read-write | The command status for this slot configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Slot Device Commands used in SET Command (1..99) update-slot-config (1) change an aspect of current slot configuration delete-slot-config (2) remove existing Slot Configuration. Deleting the Slot Configuration using the Slot Command Status will result in the removal of all configured connections associated with that slot number. ndr-switchover (10) force a switchover to the Standby device ndr-restore (11) force a restore back to the original device Response States used in GET RESPONSE Command (100..199) update-successful (101) slot data has been successfully changed delete-successful (102) slot data has been successfully removed switch-successful (110) Slot N+1 Redundancy device has been successfully switched over to Standby device restore-successful (111) Slot N+1 Redundancy device has been successfully restored back to Primary device Slot Config Error Codes used in GET RESPONSE Command (200..799) err-general-slot-config-error (200) Unknown slot configuration error occurred. err-invalid-slot-type (201) Configured slot type not in valid range err-invalid-slot-command (202) Unrecognized slot command-action err-invalid-slot-name (203) Configured slot name too long err-redundancy-disabled (204) Redundancy disabled on this system or does not apply to device type err-cannot-chg-sys-device (205) System Device type does not support configuration change err-invalid-redundancy-state (207) Redundancy state does not apply or invalid err-cannot-delete-online-device (208) Device cannot be present when deleting configuration err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big |
| I32 numberSlots | 1.3.6.1.4.1.644.2.4.1.4 | Integer32 | read-only | This is the number of slots in the node. |
| STR softwareRelease | 1.3.6.1.4.1.644.2.4.1.5 | DisplayString | read-only | In the form Release x.xx where x.xx is the release number. |
| redundancy | 1.3.6.1.4.1.644.2.4.1.9 | |||
| DEC ndrEnabled | 1.3.6.1.4.1.644.2.4.1.9.1 | DecisionType | read-write | Indicates the system's capability of supporting the N+1 Device Redundancy functionality. The user should configure this variable based on the existence of the Protection Switch Box (PSX) Device. The ndrState will reflect the actual status of N+1 Redundancy. no (0) No PSX attached, N+1 Redundancy disabled. yes (1) PSX attached, N+1 Redundancy enabled. |
| INT ndrState | 1.3.6.1.4.1.644.2.4.1.9.2 | INTEGER | read-only | This is the current N+1 Device Redundancy state. disabled (1) N+1 Redundancy disabled by the user. frozen (2) N+1 Redundancy is not active due to missing hardware components. delayed (3) N+1 Redundancy is delayed due to switchover. enabled (4) N+1 Redundancy enabled and ready. |
| INT ndrAutoSwitchover | 1.3.6.1.4.1.644.2.4.1.9.3 | INTEGER | read-write | Indicates the user's desired N+1 Device Redundancy automatic Switchover setting when a primary card fails. manual (0) Failed cards will not be switched automatically by the system. User is required to go to Node Summary Console screen and force a manual switchover of the failed card to the Redundant. automatic (1) The system will automatically switch out failed cards for either NDR Group with the Redundant card. narrowband-auto (2) The system will automatically switch out a failed card for the NDR Narrowband Group with the Redundant. broadband-1-auto(3) The system will automatically switch out a failed card for the NDR Broadband Group 1 with the Redundant. broadband-2-auto(4) The system will automatically switch out a failed card for the NDR Broadband Group 2 with the Redundant. |
| INT ndrAutoRestore | 1.3.6.1.4.1.644.2.4.1.9.4 | INTEGER | read-only | Indicates the system's N+1 Device Redundancy automatic Restore setting when a protected card becomes operational. manual (0) Protected cards that become operational will not be restored automatically by the system. User is required to go to Node Summary Console screen and force a manual switchover of the Redundant card back to the Primary card. automatic (1) The system will automatically restore protected cards that become operational for either NDR Group. narrowband-auto (2) The system will automatically restore protected cards that become operational for the NDR Narrowband Group. broadband-1-auto(3) The system will automatically restore protected cards that become operational for the NDR Broadband Group 1. broadband-2-auto(4) The system will automatically restore protected cards that become operational for the NDR Broadband Group 2. |
| I32 ndrBroadbandGroup1 | 1.3.6.1.4.1.644.2.4.1.9.5 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Broadband Group 1. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Group 1 N+1 Redundancy Group. |
| I32 ndrNarrowbandGroup | 1.3.6.1.4.1.644.2.4.1.9.6 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Narrowband Group. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Narrowband N+1 Redundancy Group. |
| I32 ndrBroadbandGroup1Protected | 1.3.6.1.4.1.644.2.4.1.9.7 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Broadband Group 1 has been currently switched over. Valid Protected slots for NDR Broadband Group1 are 8 through 10. If a zero value is returned, no device card is currently protected. |
| I32 ndrNarrowbandProtected | 1.3.6.1.4.1.644.2.4.1.9.8 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Narrowband Group has been currently switched over. Valid Protected slots for NDR Narrowband Group are 2 through 11. If a zero value is returned, no device card is currently protected. |
| INT ndrBroadbandGroup1Type | 1.3.6.1.4.1.644.2.4.1.9.9 | INTEGER | read-write | This indicates which type of device is currently occupying the status of active NDR Broadband Group 1. Only one type of broadband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Broadband Group 1 type should match the device type of the card in Slot 11, which is the designated Broadband Group 1 NDR Redundant slot. |
| INT ndrNarrowbandType | 1.3.6.1.4.1.644.2.4.1.9.10 | INTEGER | read-only | This indicates which type of device is currently occupying the status of active NDR Narrowband Group. Only one type of Narrowband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Narrowband type should match the device type of the card in Slot 1, which is the designated Narrowband NDR Redundant slot. |
| DEC ndrDualBroadbandEnabled | 1.3.6.1.4.1.644.2.4.1.9.11 | DecisionType | read-write | Indicates the system's capability of supporting the N+1 Device Redundancy Dual Broadband Group functionality. The user should configure this variable based on the existence of the Upgraded PSX Hardware. no (0) PSX Dual Broadband Groups disabled or not supported. yes (1) PSX Dual Broadband Groups enabled. |
| I32 ndrBroadbandGroup2 | 1.3.6.1.4.1.644.2.4.1.9.12 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Broadband Group 2. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Group 2 N+1 Redundancy Group. |
| I32 ndrBroadbandGroup2Protected | 1.3.6.1.4.1.644.2.4.1.9.13 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Broadband Group 2 has been currently switched over. Valid Protected slots for NDR Broadband Group2 are 1 through 6. If a zero value is returned, no device card is currently protected. |
| INT ndrBroadbandGroup2Type | 1.3.6.1.4.1.644.2.4.1.9.14 | INTEGER | read-write | This indicates which type of device is currently occupying the status of active NDR Broadband Group 2. Only one type of broadband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Broadband Group 2 type should match the device type of the card in Slot 7, which is the designated Broadband Group 2 NDR Redundant slot. |
| INT ndrPsxChassisType | 1.3.6.1.4.1.644.2.4.1.9.15 | INTEGER | read-write | This indicates which type of Protection Switch Chassis Hardware has been detected. In order to run with Dual Broadband Group configuration, this value should be set to psx5300. |
| upgradeSw | 1.3.6.1.4.1.644.2.4.1.10 | |||
| devDownloadTable | 1.3.6.1.4.1.644.2.4.1.10.1 | not-accessible | A Table listing the files one could download from smc to a device card using TFTP | |
| devDownloadEntry | 1.3.6.1.4.1.644.2.4.1.10.1.1 | not-accessible | An entry in the Device Download Table | |
| I32 programFileIndex | 1.3.6.1.4.1.644.2.4.1.10.1.1.1 | Integer32 | read-only | The index of the program file available for download |
| STR programFileName | 1.3.6.1.4.1.644.2.4.1.10.1.1.2 | DisplayString | read-only | The name of the program file available for download |
| I32 programFileSize | 1.3.6.1.4.1.644.2.4.1.10.1.1.3 | Integer32 | read-only | The size in bytes of the program file available for download |
| INT programLoadStatus | 1.3.6.1.4.1.644.2.4.1.10.1.1.4 | INTEGER | read-only | The load status of the program file |
| STR programLoadInitiator | 1.3.6.1.4.1.644.2.4.1.10.1.1.5 | DisplayString | read-only | The name of the user who initiated the program file download |
| I32 programBytesSent | 1.3.6.1.4.1.644.2.4.1.10.1.1.6 | Integer32 | read-only | The number of bytes sent in the current program file download |
| I32 programSlotNumber | 1.3.6.1.4.1.644.2.4.1.10.1.1.7 | Integer32 | read-write | The slot number to which a program file is to be downloaded |
| INT programFileCommand | 1.3.6.1.4.1.644.2.4.1.10.1.1.8 | INTEGER | read-write | The command to change the load status of the program file, or an error returned from a command. |
| INT programNestNumber | 1.3.6.1.4.1.644.2.4.1.10.1.1.9 | INTEGER | read-write | The Nest number to which a program file is to be downloaded. If this field is not included in the SET PDU, the file will be downloaded to the specified slot in the First Nest (nest1). |
| eXpansionNestAdmin | 1.3.6.1.4.1.644.2.4.1.11 | |||
| xNestCfgTable | 1.3.6.1.4.1.644.2.4.1.11.1 | not-accessible | A list of the Configured and Unconfigured Nests in this node with the static and dynamic type information. The maximum number of entries is 8 nests but if this is an Stand-Alone DNX-11 system, only 1 nest entry will be returned. | |
| xNestCfgEntry | 1.3.6.1.4.1.644.2.4.1.11.1.1 | not-accessible | The conceptual row of the Nest Configuration table. A row in this table can not be created or deleted. A row in this table can be modified by providing valid values for either the Nest Name, Configured Nest Type, NDR Capability, Alarm Contacts, Dual SMCs, Dual XLCs or XCCs, or Nest Command Status. Deleting the Nest Configuration using the Nest Command Status value of 'delete-nest-config' will result in the removal of all configured slots, ports, & connections associated with that nest number. The xNestCmdStatus field must be included as a variable in a SET PDU for the action to take effect. If the xNestCmdStatus is missing from the SET PDU, the GET RESPONSE will contain the SNMP error status of 'genErr' for and an error index equal to the last variable. | |
| I32 xNestIndex | 1.3.6.1.4.1.644.2.4.1.11.1.1.1 | Integer32 | read-only | The nest index number in the node. Nests are indexed 0 through 7 but correspond to Nests 1 to 8. |
| STR xNestUnitName | 1.3.6.1.4.1.644.2.4.1.11.1.1.2 | DisplayString | read-write | The user defined name for this nest. |
| INT xNestType | 1.3.6.1.4.1.644.2.4.1.11.1.1.3 | INTEGER | read-write | This is the nest type configured by the user. The value, notConfig(0), is the default type for an unconfigured device. Note, if notConfig(0) or stm1X-oc3X(3) is used in a Set Request, the agent will return an error status of 'badValue'. Virtual stm1X-oc3X Nests are configured automatically by the system whenever the user Assigns an available Nest to an STM1X or OC3X Device pair. This can be done via the opticalDevConfigTable after a STM1X or OC3X card has been configured in a Even numbered slot. |
| INT xNestState | 1.3.6.1.4.1.644.2.4.1.11.1.1.4 | INTEGER | read-only | The current machine state of the Nests. mismatch (2) Nest is configured as wrong type. notPresent (8) Nest is unconfigured. missing (12) Nest is configured but communications are down. online (16) Nest is present and operational. offline (32) Nest is present but currently not operational. |
| INT xNestAlarmStatus | 1.3.6.1.4.1.644.2.4.1.11.1.1.5 | INTEGER | read-only | The current nest device alarm condition level that indicates it's severity. |
| I32 xNestDeviceCards | 1.3.6.1.4.1.644.2.4.1.11.1.1.6 | Integer32 | read-only | The number of device cards presently active in the nest. |
| DEC xNestNDRCapable | 1.3.6.1.4.1.644.2.4.1.11.1.1.7 | DecisionType | read-write | The configured N+1 Redundancy state of the Nest. no (0) N+1 Redundancy is not available in the Nest. yes (1) N+1 Redundancy is available in the Nest. |
| INT xNestAlarmContacts | 1.3.6.1.4.1.644.2.4.1.11.1.1.8 | INTEGER | read-write | Determines the type of desired response from the rear SMC/XNM Alarm Contact switches during an alarm event. |
| DEC xNestDualSMCs | 1.3.6.1.4.1.644.2.4.1.11.1.1.9 | DecisionType | read-write | The number of SMCs configured for the Nest. If running with only a single SMC, this should be set to 'no' in order to suppress unecessary alarms. no (0) Only 1 SMC resides in the Nest. yes (1) Both SMCs reside in the Nest. |
| DEC xNestDualXccXlc | 1.3.6.1.4.1.644.2.4.1.11.1.1.10 | DecisionType | read-write | The number of XCC devices configured for the Node Manager or number of XLC devices configured for the Nest Manager depending on Type of Nest. Nest #1 is considered the Node Manager and all other Nests are considered as Nest Managers. If running with only a single XCC or XLC, this should be set to 'no' in order to suppress unecessary alarms. no (0) Only 1 XCC/XLC resides in the Nest. yes (1) Both XCCs/XLCs reside in the Nest. |
| INT xNestCmdStatus | 1.3.6.1.4.1.644.2.4.1.11.1.1.11 | INTEGER | read-write | The command status for this nest configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Nest Device Commands used in SET Command (1..99) update-nest-config (1) change an aspect of current nest configuration delete-nest-config (2) remove existing Nest Configuration. Deleting the Nest Configuration using the Nest Command Status will result in the removal of all configured connections associated with that nest number. switch-mgr-cards (3) Perform Switchover to Standby SMC/XNM card in associated Nest reset-device-cards (4) Reset all device cards in associated Nest clear-device-errors (5) Clear error counters for all channel cards in associated Nest switch-xcc-cards (6) Perform Switchover to Standby XCC card in associated Nest switch-xlink-cards (7) Perform Switchover to Standby XLC card in associated Nest. Response States used in GET RESPONSE Command (100..199) update-successful (101) nest data has been successfully changed delete-successful (102) nest data has been successfully removed switch-mgr-successful (103) nest system managers has been successfully switched reset-successful (104) nest device cards have been issued reset requests clear-successful (105) nest device cards have been issued clear error requests switch-xcc-successful (106) nest xcc's has been successfully switched switch-xlink-successful (107) nest xlink cards has been successfully switched Nest Config Error Codes used in GET RESPONSE Command (200..799) err-general-nest-config-error (200) Unknown nest configuration error occurred. err-invalid-nest-type (201) Configured nest type not in valid range err-invalid-nest-command (202) Unrecognized nest command-action err-invalid-nest-name (203) Configured nest name too long err-invalid-nest-alrm (204) Configured nest alarm contacts not in valid range err-invalid-nest-ndr (205) N+1 Redundancy not supported for nest err-invalid-nest-option (206) Dual XCC/XLC or Dual SMC option not valid err-cannot-delete-online-nest (207) Nest cannot be online when deleting configuration err-nest-not-present (208) Nest not ready for command err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big |
| DEC xNestDualPower | 1.3.6.1.4.1.644.2.4.1.11.1.1.12 | DecisionType | read-write | The number of DNX Power Supplies configured for the Nest. If running with only a single Power Supply, this should be set to 'no' in order to suppress unecessary alarms. no (0) Only 1 Power Supply resides in the Nest. yes (1) Both Power Supplies reside in the Nest. |
| xSlotTable | 1.3.6.1.4.1.644.2.4.1.11.2 | not-accessible | A list of the Configured device cards in this node with the static and dynamic type information. The maximum number of entries depends on the number of nests times the number of slots in the system plus 3 default entries for the system manager cards and the Protection Switch. | |
| xSlotEntry | 1.3.6.1.4.1.644.2.4.1.11.2.1 | not-accessible | The conceptual row of the Slot Configuration table. A row in this table can not be created or deleted. A row in this table can be modified by providing valid values for either the Slot Name, Configured Device Type, Device Redundancy, or Slot Command Status. Deleting the Slot Configuration using the Slot Command Status value of 'delete-slot-config' will result in the removal of all configured connections associated with that slot number. The xnmSlotCfgCmdStatus field must be included as a variable in a SET PDU for the action to take effect. If the xnmSlotCfgCmdStatus is missing from the SET PDU, the GET RESPONSE will contain the SNMP error status of 'genErr' for and an error index equal to the last variable. | |
| ADR xSlotNestAddr | 1.3.6.1.4.1.644.2.4.1.11.2.1.1 | NestSlotAddress | read-only | This number uniquely identifies an Device's Nest-Slot Address. This number will be used throughout the system to identify a unique slot. The format is represented using an IP address syntax (4 byte string). The 1st byte represents the Nest Number (0..7) The 2nd byte represents the Slot Number (1..11) The 3rd byte unused The 4th byte unused |
| DNX xSlotDeviceType | 1.3.6.1.4.1.644.2.4.1.11.2.1.2 | DnxSlotDeviceType | read-write | This is the slot type configured by the user. The value, slot(0) is the default type for an unconfigured device. If slot(0) is used in a Set Request, the agent will return an error status of 'badValue'. The slot entries representing the System Manager Cards and the Protection Switch device cannot be used in a Set Request since their device type is static. |
| DNX xSlotActualDeviceType | 1.3.6.1.4.1.644.2.4.1.11.2.1.3 | DnxSlotDeviceType | read-only | This is the actual slot type sent back by the card. |
| DNX xSlotDeviceState | 1.3.6.1.4.1.644.2.4.1.11.2.1.4 | DnxSlotDeviceState | read-only | The current machine state of the device. not-present (0) Indicates no hardware detected in the slot. online (1) Device is present and is considered primary operational. offline (2) Device is present but currently not operational. disabled (3) Applies to the Protection Switch box if system cannot support redundancy. standby (4) Device is present but considered as secondary. defective (5) Device is present but could not be activated. bus-error (6) Device is present and reporting a bus connection error. out-of-serv (7) Operator has placed device in Out of Service mode. |
| INT xSlotAlarmLevel | 1.3.6.1.4.1.644.2.4.1.11.2.1.5 | INTEGER | read-only | The current slot device alarm condition level that indicates it's severity. |
| STR xSlotDeviceName | 1.3.6.1.4.1.644.2.4.1.11.2.1.6 | DisplayString | read-write | The user defined name for this slot/device. |
| STR xSlotDeviceVersion | 1.3.6.1.4.1.644.2.4.1.11.2.1.7 | DisplayString | read-only | The software version release identification number for this device. |
| INT xSlotDeviceRedundancy | 1.3.6.1.4.1.644.2.4.1.11.2.1.8 | INTEGER | read-write | The configured N+1 Redundancy state of the device. The slot entries representing the System Manager Cards and the Protection Switch device cannot be used in a Set Request since N+1 Redundancy does not apply to them. disable (0) Device is not configured as part of the Redundancy Group. enable (1) Device is configured as part of the Redundancy Group. n/a (2) Device does not support Redundancy. |
| INT xSlotMiscState | 1.3.6.1.4.1.644.2.4.1.11.2.1.9 | INTEGER | read-only | The current slot/device miscellaneous state conditions. none (0) no misc condition errors (1) errors reported on device test (2) device is in test mode errors-test (3) errors reported on device while in test mode clockSrc (4) device is the source for the system clock errors-clockSrc (5) device is the source for the system clock and errors found test-clockSrc (6) device is the source for the system clock and is in test mode errors-test-clockSrc (7) device is the source for the system clock and is in test mode and errors were found |
| INT xSlotCmdStatus | 1.3.6.1.4.1.644.2.4.1.11.2.1.10 | INTEGER | read-write | The command status for this slot configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Slot Device Commands used in SET Command (1..99) update-slot-config (1) change an aspect of current slot configuration delete-slot-config (2) remove existing Slot Configuration. Deleting the Slot Configuration using the Slot Command Status will result in the removal of all configured connections associated with that slot number. ndr-switchover (10) force a switchover to the Standby device ndr-restore (11) force a restore back to the original device Response States used in GET RESPONSE Command (100..199) update-successful (101) slot data has been successfully changed delete-successful (102) slot data has been successfully removed switch-successful (110) Slot N+1 Redundancy device has been successfully switched over to Standby device restore-successful (111) Slot N+1 Redundancy device has been successfully restored back to Primary device Slot Config Error Codes used in GET RESPONSE Command (200..799) err-general-slot-config-error (200) Unknown slot configuration error occurred. err-invalid-slot-type (201) Configured slot type not in valid range err-invalid-slot-command (202) Unrecognized slot command-action err-invalid-slot-name (203) Configured slot name too long err-redundancy-disabled (204) Redundancy disabled on this system or does not apply to device type err-cannot-chg-sys-device (205) System Device type does not support configuration change err-invalid-redundancy-state (207) Redundancy state does not apply or invalid err-cannot-delete-online-device (208) Device cannot be present when deleting configuration err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big |
| NUM xSlotRawDeviceState | 1.3.6.1.4.1.644.2.4.1.11.2.1.11 | UnsignedInt | read-only | The current raw bitmask form of the state of the slot/device. |
| xNdrTable | 1.3.6.1.4.1.644.2.4.1.11.3 | not-accessible | A list of the Nests with N+1 Redundancy capability in this node. The maximum number of entries depends on the number of nests that have a Protection Switch Device. | |
| xNdrEntry | 1.3.6.1.4.1.644.2.4.1.11.3.1 | not-accessible | The conceptual row of the N+1 Redundancy table. A row in this table can not be created or deleted. A row in this table can be modified by providing valid values for any of the configurable N+1 Redundancy fields. The xNdrCmdStatus field must be included as a variable in a SET PDU for the action to take effect. If the xNdrCmdStatus is missing from the SET PDU, the GET RESPONSE will contain the SNMP error status of 'genErr' for and an error index equal to the last variable. | |
| I32 xNdrNestIndex | 1.3.6.1.4.1.644.2.4.1.11.3.1.1 | Integer32 | read-only | The nest index number in the node. Nests are indexed 0 through 7 but correspond to Nests 1 to 8. |
| INT xNdrState | 1.3.6.1.4.1.644.2.4.1.11.3.1.2 | INTEGER | read-only | This is the current N+1 Device Redundancy state. disabled (1) N+1 Redundancy disabled by the user. frozen (2) N+1 Redundancy is not active due to missing hardware components. delayed (3) N+1 Redundancy is delayed due to switchover. enabled (4) N+1 Redundancy enabled and ready. |
| INT xNdrAutoSwitchover | 1.3.6.1.4.1.644.2.4.1.11.3.1.3 | INTEGER | read-write | Indicates the user's desired N+1 Device Redundancy automatic Switchover setting when a primary card fails. manual (0) Failed cards will not be switched automatically by the system. User is required to go to Node Summary Console screen and force a manual switchover of the failed card to the Redundant. automatic (1) The system will automatically switch out failed cards for either NDR Group with the Redundant card. narrowband-auto (2) The system will automatically switch out a failed card for the NDR Narrowband Group with the Redundant. broadband-1-auto(3) The system will automatically switch out a failed card for the NDR Broadband Group 1 with the Redundant. broadband-2-auto(4) The system will automatically switch out a failed card for the NDR Broadband Group 2 with the Redundant. |
| INT xNdrAutoRestore | 1.3.6.1.4.1.644.2.4.1.11.3.1.4 | INTEGER | read-only | Indicates the system's N+1 Device Redundancy automatic Restore setting when a protected card becomes operational. manual (0) Protected cards that become operational will not be restored automatically by the system. User is required to go to Node Summary Console screen and force a manual switchover of the Redundant card back to the Primary card. automatic (1) The system will automatically restore protected cards that become operational for either NDR Group. narrowband-auto (2) The system will automatically restore protected cards that become operational for the NDR Narrowband Group. broadband-1-auto(3) The system will automatically restore protected cards that become operational for the NDR Broadband Group 1. broadband-2-auto(4) The system will automatically restore protected cards that become operational for the NDR Broadband Group 2. |
| I32 xNdrBroadbandGroup1 | 1.3.6.1.4.1.644.2.4.1.11.3.1.5 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Broadband Group 1. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Group 1 N+1 Redundancy Group. |
| I32 xNdrNarrowbandGroup | 1.3.6.1.4.1.644.2.4.1.11.3.1.6 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Narrowband Group. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Narrowband N+1 Redundancy Group. |
| I32 xNdrBroadbandGroup1Protected | 1.3.6.1.4.1.644.2.4.1.11.3.1.7 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Broadband Group 1 has been currently switched over. Valid Protected slots for NDR Broadband Group1 are 8 through 10. If a zero value is returned, no device card is currently protected. |
| I32 xNdrNarrowbandProtected | 1.3.6.1.4.1.644.2.4.1.11.3.1.8 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Narrowband Group has been currently switched over. Valid Protected slots for NDR Narrowband Group are 2 through 11. If a zero value is returned, no device card is currently protected. |
| INT xNdrBroadbandGroup1Type | 1.3.6.1.4.1.644.2.4.1.11.3.1.9 | INTEGER | read-write | This indicates which type of device is currently occupying the status of active NDR Broadband Group 1. Only one type of broadband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Broadband Group 1 type should match the device type of the card in Slot 11, which is the designated Broadband Group 1 NDR Redundant slot. |
| INT xNdrNarrowbandType | 1.3.6.1.4.1.644.2.4.1.11.3.1.10 | INTEGER | read-only | This indicates which type of device is currently occupying the status of active NDR Narrowband Group. Only one type of Narrowband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Narrowband type should match the device type of the card in Slot 1, which is the designated Narrowband NDR Redundant slot. |
| DEC xNdrDualBroadbandEnabled | 1.3.6.1.4.1.644.2.4.1.11.3.1.11 | DecisionType | read-write | Indicates the system's capability of supporting the N+1 Device Redundancy Dual Broadband Group functionality. The user should configure this variable based on the existence of the Upgraded PSX Hardware. no (0) PSX Dual Broadband Groups disabled or not supported. yes (1) PSX Dual Broadband Groups enabled. |
| I32 xNdrBroadbandGroup2 | 1.3.6.1.4.1.644.2.4.1.11.3.1.12 | Integer32 | read-only | This is a 2 byte bit field reflecting the slots that are part of the current active NDR Broadband Group 2. The first 11 bits represent each of the slot numbers. If any of the bits are set, those slots are currently part of the Group 2 N+1 Redundancy Group. |
| I32 xNdrBroadbandGroup2Protected | 1.3.6.1.4.1.644.2.4.1.11.3.1.13 | Integer32 | read-only | This is a slot number that indicates which device card from the active NDR Broadband Group 2 has been currently switched over. Valid Protected slots for NDR Broadband Group2 are 1 through 6. If a zero value is returned, no device card is currently protected. |
| INT xNdrBroadbandGroup2Type | 1.3.6.1.4.1.644.2.4.1.11.3.1.14 | INTEGER | read-write | This indicates which type of device is currently occupying the status of active NDR Broadband Group 2. Only one type of broadband device can be supported by N+1 Redundancy at one time. Whichever type is selected as the active Broadband Group 2 type should match the device type of the card in Slot 7, which is the designated Broadband Group 2 NDR Redundant slot. |
| INT xNdrPsxChassisType | 1.3.6.1.4.1.644.2.4.1.11.3.1.15 | INTEGER | read-write | This indicates which type of Protection Switch Chassis Hardware has been detected. In order to run with Dual Broadband Group configuration, this value should be set to psx5300. |
| INT xNdrCmdStatus | 1.3.6.1.4.1.644.2.4.1.11.3.1.16 | INTEGER | read-write | The command status for this ndr configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row NDR Device Commands used in SET Command (1..99) update-ndr (1) change an aspect of current nest N+1 Redundancy Response States used in GET RESPONSE Command (100..199) update-successful (101) ndr data has been successfully changed NDR Config Error Codes used in GET RESPONSE Command (200..799) err-general-ndr-config-error (200) Unknown ndr configuration error occurred. err-invalid-ndr-group-type (201) Configured NDR Group type not in valid range err-invalid-ndr-command (202) Unrecognized NDR command-action err-invalid-ndr-autoswitch (203) NDR Auto Switchover value not in valid range err-invalid-ndr-chassis (204) NDR Chassis Type value not in valid range err-invalid-ndr-dual-bb (205) NDR Dual Broadband Group value not in valid err-invalid-ndr-dual-psx (206) NDR Dual PSX Power Supply value not in valid err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big |
| DEC xNdrDualPowerSupply | 1.3.6.1.4.1.644.2.4.1.11.3.1.17 | DecisionType | read-write | The number of N+1 Protection Switch Power Supplies configured for the Nest. If running with only a single PSX Power Supply, this should be set to 'no' in order to suppress unecessary alarms. no (0) Only 1 Power Supply resides in the PSX. yes (1) Both Power Supplies reside in the PSX. |
| dbSyncronize | 1.3.6.1.4.1.644.2.4.1.12.1.2 | |||
| DEC dbAutoSyncMode | 1.3.6.1.4.1.644.2.4.1.12.1.2.1 | DecisionType | read-write | Enables or disables the Automatic Database Synchronization. |
| INT dbSyncStatus | 1.3.6.1.4.1.644.2.4.1.12.1.2.2 | INTEGER | read-only | The current status of the System DB Synchronization. |
| U32 dbSyncProgressTime | 1.3.6.1.4.1.644.2.4.1.12.1.2.3 | Unsigned32 | read-only | The number of seconds elapsed since the DB Synchronization has been started. |
| INT dbSyncCmdStatus | 1.3.6.1.4.1.644.2.4.1.12.1.2.4 | INTEGER | read-write | The command status for this DB Synchronization. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row DB Sync Commands used in SET Command (1..99) update (1) Change the auto sync mode startDBSync (2) Starts the DB synchronization process Response States used in GET RESPONSE Command (100..199) update-successful (101) Auto Sync data has been successfully changed sync-start-successful (102) DB Sync process has been successfully started sync-completed-successful (120) DB Sync process has been successfully finished DB Sync Error Codes used in GET RESPONSE Command (200..799) err-gen-dbsync-cfg-error (200) Unknown DB Sync configuration error occurred. err-standby-not-present (201) DB Synchronization cannot be started without standby systemManager Device. err-dbsync-failed (202) DB Synchronization process has failed err-invalid-dbsync-command (203, Unrecognized DB Sync command action err-invalid-dbsync-mode (204) Unrecognized auto sync setting err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big |
| deviceAboutTable | 1.3.6.1.4.1.644.2.4.2.225 | not-accessible | This is the Device About Information table which consists of an entry for each of the Actual device cards in this node with the module, board, revision and software release information. The maximum number of entries depends on the number of nests times the number of slots in each nest. | |
| deviceAboutEntry | 1.3.6.1.4.1.644.2.4.2.225.1 | not-accessible | The conceptual row of the Device About Information table. A row in this table cannot be added or deleted, only modified. | |
| ADR devCardAddress | 1.3.6.1.4.1.644.2.4.2.225.1.1 | NestSlotAddress | read-only | This number uniquely identifies an Device's Nest-Slot Address. This number will be used throughout the system to identify a unique slot. The format is represented using an IP address syntax (4 byte string). The 1st byte represents the Nest Number (0..7) The 2nd byte represents the Slot Number (1..11) The 3rd byte unused The 4th byte unused |
| STR devSwReleaseDate | 1.3.6.1.4.1.644.2.4.2.225.1.2 | DisplayString | read-only | The release date of the software resident on the device card. |
| STR devSwChecksum | 1.3.6.1.4.1.644.2.4.2.225.1.3 | DisplayString | read-only | The checksum of the software resident on the device card. |
| STR devFrontCardType | 1.3.6.1.4.1.644.2.4.2.225.1.4 | DisplayString | read-only | The Hardware type of Front card for the device. |
| I32 devFrontCardRev | 1.3.6.1.4.1.644.2.4.2.225.1.5 | Integer32 | read-only | The Hardware revision number of the Front card. |
| STR devXilinxVersion | 1.3.6.1.4.1.644.2.4.2.225.1.6 | DisplayString | read-only | The version of Xilinx Hardware on the device card. |
| STR devRearCardType | 1.3.6.1.4.1.644.2.4.2.225.1.7 | DisplayString | read-only | The Hardware type of Rear card reported by the device. |
| I32 devRearCardRev | 1.3.6.1.4.1.644.2.4.2.225.1.8 | Integer32 | read-only | The Hardware revision number of the Rear card. |
| STR devSwVersion | 1.3.6.1.4.1.644.2.4.2.225.1.9 | DisplayString | read-only | The software version release identification number for this device. |
| eriDNXNestSysMIB | 1.3.6.1.4.1.644.3.14 | The ERI Enterprise MIB Module for the DNX Nest System Admistration. |
RFC description
Manages system-level administration and monitoring of Eastern Research DNX-88 and DNX-11 telecom switching systems.
Start monitoring Eastern Research Inc. DNX-88/DNX-11 nest multiplexer chassis (slot/redundancy administration) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.