All MIBs › ERI-DNX-NEST-SYS-MIB › xNdrAutoSwitchover
xNdrAutoSwitchover
Module: ERI-DNX-NEST-SYS-MIB
OID (symbolic): ERI-DNX-NEST-SYS-MIB::xNdrAutoSwitchover
OID (numeric): 1.3.6.1.4.1.644.2.4.1.11.3.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Indicates the user's desired N+1 Device Redundancy automatic Switchover setting when a primary card fails.
manual (0) Failed cards will not be switched automatically by the system. User is required to go to Node Summary Console screen and force a manual switchover of the failed card to the Redundant. automatic (1) The system will automatically switch out failed cards for either NDR Group with the Redundant card. narrowband-auto (2) The system will automatically switch out a failed card for the NDR Narrowband Group with the Redundant. broadband-1-auto(3) The system will automatically switch out a failed card for the NDR Broadband Group 1 with the Redundant. broadband-2-auto(4) The system will automatically switch out a failed card for the NDR Broadband Group 2 with the Redundant.
What is xNdrAutoSwitchover?
Controls how this expansion nest handles a failed redundant card: manual(0) requires an operator to force the switchover from the console, automatic(1) switches out any failed card in either NDR group automatically, and narrowband-auto(2)/broadband-1-auto(3)/broadband-2-auto(4) restrict automatic switchover to just that specific group.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.11.3.1.3 snmpwalk -v2c -c public <target> ERI-DNX-NEST-SYS-MIB::xNdrAutoSwitchover
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.11.3.1.3.1 snmpget -v2c -c public <target> ERI-DNX-NEST-SYS-MIB::xNdrAutoSwitchover.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.644.2.4.1.11.3.1.3.1 i <value>
Start monitoring Eastern Research Inc. DNX-88/DNX-11 nest multiplexer chassis (slot/redundancy administration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERI-DNX-NEST-SYS-MIB::xNdrAutoSwitchover OID value, configure state conditions and alerts, and monitor any Eastern Research Inc. DNX-88/DNX-11 nest multiplexer chassis (slot/redundancy administration) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.644 | eriEnterpriseRoot | ERI-ROOT-SMI |
| 1.3.6.1.4.1.644.2 | eriProducts | ERI-ROOT-SMI |
| 1.3.6.1.4.1.644.2.4 | dnx | ERI-DNX-SMC-MIB |
| 1.3.6.1.4.1.644.2.4.1 | sysMgr | ERI-DNX-SMC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.644.2.4.1.11 | eXpansionNestAdmin | ERI-DNX-NEST-SYS-MIB |
| 1.3.6.1.4.1.644.2.4.1.11.3 | xNdrTable | ERI-DNX-NEST-SYS-MIB |
| 1.3.6.1.4.1.644.2.4.1.11.3.1 | xNdrEntry | ERI-DNX-NEST-SYS-MIB |
| 1.3.6.1.4.1.644.2.4.1.11.3.1.3 | xNdrAutoSwitchover | ERI-DNX-NEST-SYS-MIB |