All MIBs › ELTEK-DISTRIBUTED-PLANT-MIB
Category: Domain: Power/UPS, Vendor: Eltek
Description: Eltek distributed plant MIB for managing Eltek distributed power plant installations including rectifiers and battery systems.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ELTEK-DISTRIBUTED-PLANT-MIB?
ELTEK-DISTRIBUTED-PLANT-MIB is a vendor-specific MIB from Eltek for managing distributed DC power plant installations - rectifier systems and battery backup - typically used to power telecom sites. It exposes a system-level table of control units (rectifier/monitoring controllers distributed across a site) along with system time, trap-repeat rate, and generic user-configurable input points. Its core monitoring purpose is hardware/environmental status of the power plant: tracking systemNumOfControlUnits and per-unit inputControlUnitID lets an operator confirm every rectifier/controller in a distributed plant is present and reporting, while systemSendOffTrap and systemTrapRepeatRate control how persistently power-fault alarms such as rectifier failure or low battery are repeated until acknowledged. It is a self-contained proprietary MIB defining its own OID branch (eltekDistributedPlant) rather than depending on standard power/UPS MIBs. It is deployed in telecom central offices, cell sites, and other facilities using Eltek distributed DC power/rectifier plants for critical equipment power, where ELTEK-DISTRIBUTED-PLANT-MIB SNMP monitoring gives operations staff early warning of rectifier or battery faults before they affect service.
IPNetwork Monitor allows you to monitor SNMP objects defined in ELTEK-DISTRIBUTED-PLANT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Eltek distributed DC power plant/rectifier systems
- telecom site power and battery backup equipment
Monitoring Examples
An operator polls systemControlUnitTable/systemControlUnitEntry indexed by inputControlUnitID to confirm all systemNumOfControlUnits expected units are reporting in; a missing or non-responding control unit signals a lost rectifier/battery controller in the distributed plant. systemTimeTime is checked against NTP to ensure alarm timestamps are trustworthy, and systemTrapRepeatRate/systemSendOffTrap are tuned so an ongoing rectifier or DC-power fault keeps re-alerting operations staff until resolved. inputUserConfigurable1-3 expose site-specific analog/digital points, such as a door alarm or generator status, that the plant controller monitors.
What Can Be Monitored
- number and status of distributed control units
- system time/clock
- trap repeat rate for ongoing alarms
- off/on trap send control
- user-configurable site input points
This MIB depends on
Related MIBs
Imported Objects
From ELTEK-COMMON-MIB
| eltek | MODULE-IDENTITY |
From SNMPv2-CONF
| NOTIFICATION-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises | |
| mib-2 |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| eltekDistributedPlant | 1.3.6.1.4.1.12148.8 | |||
| controlSystem | 1.3.6.1.4.1.12148.8.1 | |||
| systemTime | 1.3.6.1.4.1.12148.8.1.1 | |||
| STR systemTimeTime | 1.3.6.1.4.1.12148.8.1.1.1 | DisplayString | read-only | The system date and time. Used for event timestamps and logging |
| INT systemInfoRefresh | 1.3.6.1.4.1.12148.8.1.2 | INTEGER | read-write | This object will re-initialize the agent, updating MIB data values. |
| I32 systemTrapRepeatRate | 1.3.6.1.4.1.12148.8.1.3 | Integer32 | read-write | This object sets the repeat rate of any active traps, in seconds. Entering 0 (zero) will prevent repeating traps - one trap only will be sent per alarm event. |
| INT systemSendOffTrap | 1.3.6.1.4.1.12148.8.1.4 | INTEGER | read-write | A separate off-trap will be issued when an alarm condition goes off, if this flag is set to 1. Entering 0 (zero) will prevent OFF traps from being transmitted. |
| I32 systemNumOfControlUnits | 1.3.6.1.4.1.12148.8.1.5 | Integer32 | read-only | The number of expected system controllers (smartpacks, smartnodes stc.) in a distributed system |
| I32 systemControlUnitIndex | 1.3.6.1.4.1.12148.8.1.6 | Integer32 | accessible-for-notify | Index used for navigating int the table of 1 to 8 system controller input groups |
| systemControlUnitTable | 1.3.6.1.4.1.12148.8.1.7 | not-accessible | ||
| systemControlUnitEntry | 1.3.6.1.4.1.12148.8.1.7.1 | not-accessible | ||
| I32 inputControlUnitID | 1.3.6.1.4.1.12148.8.1.7.1.1 | Integer32 | read-only | |
| INT inputUserConfigurable1 | 1.3.6.1.4.1.12148.8.1.7.1.2 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable2 | 1.3.6.1.4.1.12148.8.1.7.1.3 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable3 | 1.3.6.1.4.1.12148.8.1.7.1.4 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable4 | 1.3.6.1.4.1.12148.8.1.7.1.5 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable5 | 1.3.6.1.4.1.12148.8.1.7.1.6 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable6 | 1.3.6.1.4.1.12148.8.1.7.1.7 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable7 | 1.3.6.1.4.1.12148.8.1.7.1.8 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable8 | 1.3.6.1.4.1.12148.8.1.7.1.9 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable9 | 1.3.6.1.4.1.12148.8.1.7.1.10 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT inputUserConfigurable10 | 1.3.6.1.4.1.12148.8.1.7.1.11 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT systemLinkStatus | 1.3.6.1.4.1.12148.8.1.8 | INTEGER | read-only | A flag showing the status of the serial port used between the Webpower adapter and the Control system. If this flag shows status linkdown, the propable cause is that the wrong baudrate is set, which again is likely to happen when booting a brand new board. Execute a 'systemInitiateEEPROM' command to fix. |
| INT systemInitiateEEPROM | 1.3.6.1.4.1.12148.8.1.9 | INTEGER | read-write | pushbutton function that initiates a forced write of baudrate of 38400bps for the serial port. It also writes default data to the eeprom. This function is used for productiontest only. The 3rd party OS used in this application are not able to write default data to EEPROM at boot time. A minimum set of configuration is thus created in RAM. A production test facility must therefore run this command as a part of the production test for the unit to function properly. |
| dcSystem | 1.3.6.1.4.1.12148.8.2 | |||
| dcPlant | 1.3.6.1.4.1.12148.8.2.1 | |||
| systemSiteInfo | 1.3.6.1.4.1.12148.8.2.1.3 | |||
| STR systemSiteInfoCustomer | 1.3.6.1.4.1.12148.8.2.1.3.1 | DisplayString | read-only | The Customer name (as stored in the Smartpack Control Unit) |
| STR systemSiteInfoLocation | 1.3.6.1.4.1.12148.8.2.1.3.2 | DisplayString | read-only | The system/site Location details (as stored in the Smartpack Control Unit). |
| STR systemSiteInfoMessage1 | 1.3.6.1.4.1.12148.8.2.1.3.3 | DisplayString | read-only | The system/site Info Message record #1 (as stored in the Smartpack Control Unit). 31 Bytes. |
| STR systemSiteInfoMessage2 | 1.3.6.1.4.1.12148.8.2.1.3.4 | DisplayString | read-only | The system/site Info Message record #2 (as stored in the Smartpack Control Unit). 31 Bytes. |
| STR systemSiteInfoInstalledDate | 1.3.6.1.4.1.12148.8.2.1.3.5 | DisplayString | read-only | The system's Installed Date text string (as stored in the Smartpack Control Unit) 16bytes. |
| INT systemSiteInfoControllerType | 1.3.6.1.4.1.12148.8.2.1.3.6 | INTEGER | read-only | The system Controller Module currently connected. AL175/MCU=0; AEON Gold=1; AL6000=2; Smartpack=3 |
| STR systemSiteInfoSystemSeriaNum | 1.3.6.1.4.1.12148.8.2.1.3.7 | DisplayString | read-only | The serial number for the complete system |
| STR systemSiteInfoControllerSeriaNum | 1.3.6.1.4.1.12148.8.2.1.3.8 | DisplayString | read-only | The serial number for the system controller |
| INT systemNominalVoltage | 1.3.6.1.4.1.12148.8.2.1.4 | INTEGER | read-only | The nominal voltage rating. 12V/24V/48V/60V systems 0=48V 1=24V 2=12V 3=26V 4=60V |
| INT systemOperationalStatus | 1.3.6.1.4.1.12148.8.2.2 | INTEGER | read-only | A summary status showing if the system is testing, boosting, floating etc. 0=Float, voltage regulated 1=Float, temperature comp. regulated; 2=equalize 3=battery test |
| battery | 1.3.6.1.4.1.12148.8.3 | |||
| STR batteryName | 1.3.6.1.4.1.12148.8.3.1 | DisplayString | read-only | A descriptive name of the battery installed in the system |
| I32 batteryVoltage | 1.3.6.1.4.1.12148.8.3.2 | Integer32 | read-only | The measured battery voltage. |
| I32 batteryCurrent | 1.3.6.1.4.1.12148.8.3.3 | Integer32 | read-only | The measured battery current. |
| I32 batteryTemp | 1.3.6.1.4.1.12148.8.3.4 | Integer32 | read-only | The battery temperature |
| INT batteryBreakerStatus | 1.3.6.1.4.1.12148.8.3.5 | INTEGER | read-only | The state of the battery fuse/breaker can be either closed(0) or open(1) |
| INT batteryChargeCurrentLimitCtrl | 1.3.6.1.4.1.12148.8.3.6 | INTEGER | read-write | Control field for the battery charge limitation feature; 0=inactive, 1=active. |
| I32 batteryChargeCurrentLimitValue | 1.3.6.1.4.1.12148.8.3.7 | Integer32 | read-write | Battery charging current limit value |
| INT batteryTempCompEnable | 1.3.6.1.4.1.12148.8.3.8 | INTEGER | read-write | Enable (0) or Disable (1) Battery Temperature Compensated output regulation mode |
| I32 batteryFloatVoltConfig | 1.3.6.1.4.1.12148.8.3.9 | Integer32 | read-write | The Voltage at which the DC System float charges. |
| I32 batteryEqualizeVoltConfig | 1.3.6.1.4.1.12148.8.3.10 | Integer32 | read-write | The Voltage at which the DC System boost charges the batteries. |
| I32 batteryHighMajorAlarmVoltageConfig | 1.3.6.1.4.1.12148.8.3.11 | Integer32 | read-write | The High Battery Voltage alarm limit set voltage |
| I32 batteryHighMinorAlarmVoltageConfig | 1.3.6.1.4.1.12148.8.3.12 | Integer32 | read-write | The High Battery Voltage alarm limit set voltage |
| I32 batteryLowMajorAlarmVoltageConfig | 1.3.6.1.4.1.12148.8.3.13 | Integer32 | read-write | The Low Battery Voltage Alarm limit set voltage |
| I32 batteryLowMinorAlarmVoltageConfig | 1.3.6.1.4.1.12148.8.3.14 | Integer32 | read-write | The Very Low Battery Voltage Alarm limit set voltage |
| INT batteryStartManualTest | 1.3.6.1.4.1.12148.8.3.15 | INTEGER | read-write | This pushbutton will start a manual battery test if otherwise the system allows it. |
| INT batteryStartManualBoost | 1.3.6.1.4.1.12148.8.3.16 | INTEGER | read-write | This pushbutton will start a manual battery boost if otherwise the system allows it. |
| batteryLVD | 1.3.6.1.4.1.12148.8.3.17 | |||
| INT batteryLVDStatus | 1.3.6.1.4.1.12148.8.3.17.1 | INTEGER | read-only | Contactor is closed(0) or open(1) |
| I32 batteryLVDDisconnectVoltage | 1.3.6.1.4.1.12148.8.3.17.2 | Integer32 | read-write | The Contactor Disconnect Voltage |
| I32 batteryLVDConnectVoltage | 1.3.6.1.4.1.12148.8.3.17.3 | Integer32 | read-write | The Contactor Reconnect Voltage |
| I32 batteryBanksNumofBanks | 1.3.6.1.4.1.12148.8.3.18 | Integer32 | read-only | |
| batteryBanks | 1.3.6.1.4.1.12148.8.3.19 | |||
| I32 batterySymmetryDeltaLimitVoltage | 1.3.6.1.4.1.12148.8.3.19.1 | Integer32 | read-write | The allowable deviation of the midpoint battery voltage from the theoretical. Exceeding this value in either direction (+/-) causes an alarm state |
| I32 batteryBanksIndex | 1.3.6.1.4.1.12148.8.3.19.2 | Integer32 | accessible-for-notify | Index used for navigating int the table of 1 to 8 batterybank symmetry groups |
| batteryBanksTable | 1.3.6.1.4.1.12148.8.3.19.3 | not-accessible | A table of up to 8 battery banks. Each bank may have up to 8 symmetry or midpoint measuments | |
| batteryBanksEntry | 1.3.6.1.4.1.12148.8.3.19.3.1 | not-accessible | a distributed control system may contain up to 8 battery banks. | |
| I32 batteryBankID | 1.3.6.1.4.1.12148.8.3.19.3.1.1 | Integer32 | read-only | |
| INT batteryBanksSymmetry1enable | 1.3.6.1.4.1.12148.8.3.19.3.1.2 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry1status | 1.3.6.1.4.1.12148.8.3.19.3.1.3 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry1deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.4 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry2enable | 1.3.6.1.4.1.12148.8.3.19.3.1.5 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry2status | 1.3.6.1.4.1.12148.8.3.19.3.1.6 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry2deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.7 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry3enable | 1.3.6.1.4.1.12148.8.3.19.3.1.8 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry3status | 1.3.6.1.4.1.12148.8.3.19.3.1.9 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry3deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.10 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry4enable | 1.3.6.1.4.1.12148.8.3.19.3.1.11 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry4status | 1.3.6.1.4.1.12148.8.3.19.3.1.12 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry4deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.13 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry5enable | 1.3.6.1.4.1.12148.8.3.19.3.1.14 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry5status | 1.3.6.1.4.1.12148.8.3.19.3.1.15 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry5deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.16 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry6enable | 1.3.6.1.4.1.12148.8.3.19.3.1.17 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry6status | 1.3.6.1.4.1.12148.8.3.19.3.1.18 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry6deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.19 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry7enable | 1.3.6.1.4.1.12148.8.3.19.3.1.20 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry7status | 1.3.6.1.4.1.12148.8.3.19.3.1.21 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry7deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.22 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| INT batteryBanksSymmetry8enable | 1.3.6.1.4.1.12148.8.3.19.3.1.23 | INTEGER | read-write | When set to 'on' the the symmetry input is activated. when turned off, measuments for this input is turned off and the correcponding value will read 0 volts and the alarm flag will be turned off |
| INT batteryBanksSymmetry8status | 1.3.6.1.4.1.12148.8.3.19.3.1.24 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 batteryBanksSymmetry8deltaVoltage | 1.3.6.1.4.1.12148.8.3.19.3.1.25 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| loadDistribution | 1.3.6.1.4.1.12148.8.4 | |||
| I32 loadDistributionCurrent | 1.3.6.1.4.1.12148.8.4.1 | Integer32 | read-only | The total load current |
| INT loadDistributionBreakerStatus | 1.3.6.1.4.1.12148.8.4.2 | INTEGER | read-only | The state of the load fuse/breaker can be either closed(0) or open(1) |
| loadDistributionLVDStatus | 1.3.6.1.4.1.12148.8.4.3 | |||
| INT loadLVD1EnableStatus | 1.3.6.1.4.1.12148.8.4.3.1 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD1Status | 1.3.6.1.4.1.12148.8.4.3.2 | INTEGER | read-only | The primary load Contactor is closed(0) or open(1) |
| I32 loadLVD1ConnectVoltage | 1.3.6.1.4.1.12148.8.4.3.3 | Integer32 | read-write | The primary loads Contactor Connect Voltage |
| I32 loadLVD1DisconnectVoltage | 1.3.6.1.4.1.12148.8.4.3.4 | Integer32 | read-write | The primary load Contactor Disconnect Voltage |
| INT loadLVD2EnableStatus | 1.3.6.1.4.1.12148.8.4.3.5 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD2Status | 1.3.6.1.4.1.12148.8.4.3.6 | INTEGER | read-only | The secondary load Contactor is closed(0) or open(1) |
| I32 loadLVD2ConnectVoltage | 1.3.6.1.4.1.12148.8.4.3.7 | Integer32 | read-write | The secondary load Contactor Connect Voltage |
| I32 loadLVD2DisconnectVoltage | 1.3.6.1.4.1.12148.8.4.3.8 | Integer32 | read-write | The secondary loads Contactor Disconnect Voltage |
| INT loadLVD3EnableStatus | 1.3.6.1.4.1.12148.8.4.3.9 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD3Status | 1.3.6.1.4.1.12148.8.4.3.10 | INTEGER | read-only | The third critical loads Contactor is closed(0) or open(1) |
| I32 loadLVD3ConnectVoltage | 1.3.6.1.4.1.12148.8.4.3.11 | Integer32 | read-write | The third critical load Contactor Connect Voltage |
| I32 loadLVD3DisconnectVoltage | 1.3.6.1.4.1.12148.8.4.3.12 | Integer32 | read-write | The third critical loads Contactor Disconnect Voltage |
| rectifier | 1.3.6.1.4.1.12148.8.5 | |||
| I32 rectifierInstalledRectifiers | 1.3.6.1.4.1.12148.8.5.1 | Integer32 | read-only | The installed number of rectifiers for this DC Power System. |
| I32 rectifierRectifiersActive | 1.3.6.1.4.1.12148.8.5.2 | Integer32 | read-only | The actual number of active rectifiers in this DC Power System. |
| I32 rectifierTotalCurrent | 1.3.6.1.4.1.12148.8.5.3 | Integer32 | read-only | The DC system's total available current |
| I32 rectifierUtilization | 1.3.6.1.4.1.12148.8.5.4 | Integer32 | read-only | Utilization in % of available rectifier capacity |
| rectifierStatus | 1.3.6.1.4.1.12148.8.5.5 | |||
| I32 rectifierStatusNoIndex | 1.3.6.1.4.1.12148.8.5.5.1 | Integer32 | read-write | A starting index for the rectifierStatusTable array |
| rectifierStatusTable | 1.3.6.1.4.1.12148.8.5.5.2 | not-accessible | A table listing up to sixteen sequential recifiers, starting from the rectifier number specified by rectifierStatusNoIndex | |
| rectifierStatusEntry | 1.3.6.1.4.1.12148.8.5.5.2.1 | not-accessible | A row of rectifier status data corresponding to the rectifierStatusNoIndex value | |
| I32 rectifierStatusID | 1.3.6.1.4.1.12148.8.5.5.2.1.1 | Integer32 | read-only | The rectifier ID number of the rectifier record. |
| INT rectifierStatusStatus | 1.3.6.1.4.1.12148.8.5.5.2.1.2 | INTEGER | read-only | The operational status of the rectifier record. absent (0), active (1), failed (2), walkin (3), disabledbycommand (4) |
| I32 rectifierStatusOutputCurrent | 1.3.6.1.4.1.12148.8.5.5.2.1.3 | Integer32 | read-only | The rectifier current of the rectifier record. |
| I32 rectifierStatusOutputVoltage | 1.3.6.1.4.1.12148.8.5.5.2.1.4 | Integer32 | read-only | The rectifier voltage of the rectifier record. |
| I32 rectifierStatusTemp | 1.3.6.1.4.1.12148.8.5.5.2.1.5 | Integer32 | read-only | The heatsink temperature of the rectifier record. |
| STR rectifierStatusType | 1.3.6.1.4.1.12148.8.5.5.2.1.6 | DisplayString | read-only | The rectifier article number string of the rectifier record. |
| STR rectifierStatusSKU | 1.3.6.1.4.1.12148.8.5.5.2.1.7 | DisplayString | read-only | The rectifier Stock Keeping Unit number or other user-defined ID of the rectifier record. |
| STR rectifierStatusSerialNo | 1.3.6.1.4.1.12148.8.5.5.2.1.8 | DisplayString | read-only | The rectifier serial number string of the rectifier record. |
| STR rectifierStatusRevisionLevel | 1.3.6.1.4.1.12148.8.5.5.2.1.9 | DisplayString | read-only | The rectifier version number string of the rectifier record. |
| acDistribution | 1.3.6.1.4.1.12148.8.6 | |||
| I32 acVoltage1 | 1.3.6.1.4.1.12148.8.6.1 | Integer32 | read-only | The AC Voltage of phase 1 |
| I32 acVoltage2 | 1.3.6.1.4.1.12148.8.6.2 | Integer32 | read-only | The AC Voltage of phase 2 |
| I32 acVoltage3 | 1.3.6.1.4.1.12148.8.6.3 | Integer32 | read-only | The AC Voltage of phase 3 |
| alarmGroup | 1.3.6.1.4.1.12148.8.7 | |||
| alarmWellknownAlarms | 1.3.6.1.4.1.12148.8.7.1 | |||
| INT alarmMajorHighBattVolt | 1.3.6.1.4.1.12148.8.7.1.1 | INTEGER | read-only | The Very High Battery Voltage Alarm |
| INT alarmMinorHighBattVolt | 1.3.6.1.4.1.12148.8.7.1.2 | INTEGER | read-only | The High Battery Voltage alarm |
| INT alarmMajorLowBattVolt | 1.3.6.1.4.1.12148.8.7.1.3 | INTEGER | read-only | The Very Low Battery Voltage Alarm |
| INT alarmMinorLowBattVolt | 1.3.6.1.4.1.12148.8.7.1.4 | INTEGER | read-only | The Low Battery Voltage Alarm |
| INT alarmMajorBatteryHighTemp | 1.3.6.1.4.1.12148.8.7.1.5 | INTEGER | read-only | Temperature much too high alarm, or temperature compensation circuit / probe failure alarm |
| INT alarmMinorBatteryHighTemp | 1.3.6.1.4.1.12148.8.7.1.6 | INTEGER | read-only | Temperature much too high alarm |
| INT alarmBatteryDisconnectOpen | 1.3.6.1.4.1.12148.8.7.1.7 | INTEGER | read-only | The Battery Disconnect Contactor alarm |
| INT alarmLVD1open | 1.3.6.1.4.1.12148.8.7.1.8 | INTEGER | read-only | The A Bus (primary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmLVD2open | 1.3.6.1.4.1.12148.8.7.1.9 | INTEGER | read-only | The B Bus (secondary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmLVD3open | 1.3.6.1.4.1.12148.8.7.1.10 | INTEGER | read-only | The C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmACmains | 1.3.6.1.4.1.12148.8.7.1.11 | INTEGER | read-only | The AC voltage has dropped below critical level, or one or more AC input phases was lost. |
| INT alarmBatteryBreakerOpen | 1.3.6.1.4.1.12148.8.7.1.12 | INTEGER | read-only | Battery string disconnect breaker/fuse alarm |
| INT alarmDistributionBreakerOpen | 1.3.6.1.4.1.12148.8.7.1.13 | INTEGER | read-only | The Load Distribution breaker/fuse alarm |
| INT alarmMajorRectifier | 1.3.6.1.4.1.12148.8.7.1.14 | INTEGER | read-only | This is a 'multiple rectifiers have failed' alarm |
| INT alarmMinorRectifier | 1.3.6.1.4.1.12148.8.7.1.15 | INTEGER | read-only | This is a 'one rectifier has failed' alarm |
| INT alarmMajorBatteryMidpoint | 1.3.6.1.4.1.12148.8.7.1.16 | INTEGER | read-only | Battery Symmetry (midpoint) Delta Voltage is badly out of limits alarm |
| INT alarmMinorBatteryMidpoint | 1.3.6.1.4.1.12148.8.7.1.17 | INTEGER | read-only | Battery Symmetry (midpoint) Delta Voltage out of limits alarm |
| INT alarmBatteryLifeEnded | 1.3.6.1.4.1.12148.8.7.1.18 | INTEGER | read-only | The battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery lifecycle to be near expired. |
| INT alarmBatteryTestmodeEntered | 1.3.6.1.4.1.12148.8.7.1.19 | INTEGER | read-only | The system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testing is reached, the charge voltage is increased to commence normal charging. |
| INT alarmBatteryBoostmodeEntered | 1.3.6.1.4.1.12148.8.7.1.20 | INTEGER | read-only | The system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is reached, the charge voltage is lowered to commence normal charging. |
| dcSystemTraps | 1.3.6.1.4.1.12148.8.8 | This branch contains the Alarm Notification Traps, which duplicate the alarmGroup OIDs. Each alarm condition is represented by a Alarm Condition Trap and an associated OFF Trap, which is optionally transmitted according to the state of OID systemSendOffTrap | ||
| NTF alarmMajorHighBattVoltTrap | 1.3.6.1.4.1.12148.8.8.1 | The Very High Battery Voltage alarm | ||
| NTF alarmMinorHighBattVoltTrap | 1.3.6.1.4.1.12148.8.8.2 | The High Battery Voltage alarm | ||
| NTF alarmMajorLowBattVoltTrap | 1.3.6.1.4.1.12148.8.8.3 | The Very Low Battery Voltage Alarm | ||
| NTF alarmMinorLowBattVoltTrap | 1.3.6.1.4.1.12148.8.8.4 | The Low Battery Voltage Alarm | ||
| NTF alarmMajorBatteryHighTempTrap | 1.3.6.1.4.1.12148.8.8.5 | High Battery temperature alarm or Temperature Compensation circuit / probe failure alarm | ||
| NTF alarmMinorBatteryHighTempTrap | 1.3.6.1.4.1.12148.8.8.6 | High Battery temperature alarm | ||
| NTF alarmBatteryDisconnectOpenTrap | 1.3.6.1.4.1.12148.8.8.7 | The Battery Disconnect Contactor alarm | ||
| NTF alarmLVD1openTrap | 1.3.6.1.4.1.12148.8.8.8 | The A Bus (primary loads) Contactor is open alarm | ||
| NTF alarmLVD2openTrap | 1.3.6.1.4.1.12148.8.8.9 | The B Bus (secondary loads) Contactor is open alarm | ||
| NTF alarmLVD3openTrap | 1.3.6.1.4.1.12148.8.8.10 | The C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor is released. | ||
| NTF alarmACmainsTrap | 1.3.6.1.4.1.12148.8.8.11 | The AC voltage has dropped below critical level, or one or more AC input phases was lost. | ||
| NTF alarmBatteryBreakerOpenTrap | 1.3.6.1.4.1.12148.8.8.12 | Battery string disconnect breaker/fuse alarm | ||
| NTF alarmDistributionBreakerOpenTrap | 1.3.6.1.4.1.12148.8.8.13 | The Load Distribution breaker/fuse alarm | ||
| NTF alarmMajorRectifierTrap | 1.3.6.1.4.1.12148.8.8.14 | This is a 'multiple rectifiers have failed' alarm | ||
| NTF alarmMinorRectifierTrap | 1.3.6.1.4.1.12148.8.8.15 | This is a 'one rectifier has failed' alarm | ||
| NTF alarmMajorBatteryMidpointTrap | 1.3.6.1.4.1.12148.8.8.16 | Battery Symmetry (midpoint) Delta Voltage out of 'major fault' limits alarm | ||
| NTF alarmMinorBatteryMidpointTrap | 1.3.6.1.4.1.12148.8.8.17 | Battery Symmetry (midpoint) Delta Voltage out of limits alarm | ||
| NTF alarmBatteryLifeEndedTrap | 1.3.6.1.4.1.12148.8.8.18 | The battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery lifecycle to be near expired. | ||
| NTF alarmBatteryTestmodeEnteredTrap | 1.3.6.1.4.1.12148.8.8.19 | The system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testing is reached, the charge voltage is increased to commence normal charging. | ||
| NTF alarmBatteryBoostmodeEnteredTrap | 1.3.6.1.4.1.12148.8.8.20 | The system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is reached, the charge voltage is lowered to commence normal charging. | ||
| NTF alarmController1proginputTrap | 1.3.6.1.4.1.12148.8.8.21 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController2proginputTrap | 1.3.6.1.4.1.12148.8.8.22 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController3proginputTrap | 1.3.6.1.4.1.12148.8.8.23 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController4proginputTrap | 1.3.6.1.4.1.12148.8.8.24 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController5proginputTrap | 1.3.6.1.4.1.12148.8.8.25 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController6proginputTrap | 1.3.6.1.4.1.12148.8.8.26 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController7proginputTrap | 1.3.6.1.4.1.12148.8.8.27 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmController8proginputTrap | 1.3.6.1.4.1.12148.8.8.28 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
RFC description
Manages ELTEK Distributed Control System power plant designs with system time and event trapping.
Start monitoring Eltek distributed DC power plant/rectifier system with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.