ELTEK-DISTRIBUTED-PLANTV4-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ELTEK-DISTRIBUTED-PLANTV4-MIB

Category: Domain: Power/UPS, Vendor: Eltek

Description: Eltek Distributed Plant v4 MIB for monitoring fourth-generation telecom power plant components including rectifiers, batteries, and breakers.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ELTEK-DISTRIBUTED-PLANTV4-MIB?

ELTEK-DISTRIBUTED-PLANTV4-MIB is Eltek's fourth-generation "Distributed Plant" MIB for telecom DC power plants, covering rectifiers, batteries, and breakers distributed across a site's power infrastructure. It exposes system-wide configuration such as system time/date (used for event timestamping), trap repeat rate and notification behavior, and a hierarchy of "control units" (systemControlUnitTable) each representing a distributed power controller with configurable inputs. Its core value is monitoring the hardware/operational status of telecom power plants -- tracking each control unit's presence and configuration, its user-configurable digital inputs, and system-level alarm/trap generation (systemSendOffTrap) that reports rectifier, battery, or breaker faults across the distributed plant. It's a self-contained Eltek enterprise MIB, though it functions as the top-level "controlSystem" branch that other Eltek plant-specific sub-MIBs (for rectifiers, batteries, etc.) build on. It is deployed in telecom central offices, cell sites, and cabinets where an Eltek DC power plant provides regulated, battery-backed power to networking or telecom equipment. Engineers can download the ELTEK-DISTRIBUTED-PLANTV4-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ELTEK-DISTRIBUTED-PLANTV4-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Eltek Distributed Plant v4 telecom DC power system (rectifiers, batteries, breakers)

Monitoring Examples

An administrator polls systemControlUnitTable/systemControlUnitEntry via systemControlUnitIndex to enumerate each distributed power controller in the plant and confirm all expected units are reporting in. systemTimeTime is checked to ensure the plant's clock is synchronized so that alarm event timestamps are trustworthy, and systemTrapRepeatRate/systemSendOffTrap settings are reviewed to confirm alarms (e.g., a rectifier or battery fault elsewhere in the Eltek plant hierarchy) will be re-sent until acknowledged. inputUserConfigurable1-3 on a given control unit can be checked to see custom digital input status wired to site-specific alarms such as a door or generator contact.

What Can Be Monitored

  • system time/clock sync
  • control unit inventory/status
  • trap repeat rate/alarm notification settings
  • custom digital input status
  • distributed power controller configuration
Imported Objects

From ELTEK-COMMON-MIB

eltekMODULE-IDENTITY

From SNMPv2-CONF

NOTIFICATION-GROUP

From SNMPv2-SMI

Counter32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
enterprises
mib-2

From SNMPv2-TC

DisplayString
OIDs

RFC description

Eltek distributed plant (DC power system) v4 MIB. Monitors rectifier, charger, battery modules, and distribution equipment in distributed power systems.

Start monitoring Eltek telecom DC power systems with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.