| OID symbolic | OID numeric | Type | Access | Description |
| board | 1.3.6.1.4.1.534.6.6.6.1 | | | |
| compliance | 1.3.6.1.4.1.534.6.6.6.9.1.1 | | | The requirements for conformance to the PDU-MIB. |
| compliances | 1.3.6.1.4.1.534.6.6.6.9.1 | | | |
| NTF deviceUpdateStarted | 1.3.6.1.4.1.534.6.6.6.0.20 | | | The device update has started |
| eatonEpduMa | 1.3.6.1.4.1.534.6.6.6 | | | The MIB module for Eaton ePDUs (Enclosed Power Distribution Units)
-Managed Model. |
| environmental | 1.3.6.1.4.1.534.6.6.6.2 | | | |
| externalHumidityGroup | 1.3.6.1.4.1.534.6.6.6.9.2.7 | | | A collection of objects providing external humidity sensor readings and threshold settings. |
| externalTemperatureGroup | 1.3.6.1.4.1.534.6.6.6.9.2.6 | | | A collection of objects providing external temperature sensor readings and threshold settings. |
| NTF firmwareFileDiscarded | 1.3.6.1.4.1.534.6.6.6.0.36 | | | A firmware file discarded |
| NTF firmwareValidationFailed | 1.3.6.1.4.1.534.6.6.6.0.38 | | | A firmware validation failed |
| STR firmwareVersion | 1.3.6.1.4.1.534.6.6.6.1.1.1 | DisplayString | read-only | The current firmware version |
| IP gateway | 1.3.6.1.4.1.534.6.6.6.1.1.5 | IpAddress | read-only | The current Gateway. A value of 0.0.0.0 indicates an error
or an unset option. |
| NTF groupAdded | 1.3.6.1.4.1.534.6.6.6.0.14 | | | A group was added to the system |
| NTF groupDeleted | 1.3.6.1.4.1.534.6.6.6.0.16 | | | A group was deleted from the system |
| NTF groupModified | 1.3.6.1.4.1.534.6.6.6.0.15 | | | A group was modified |
| STR groupName | 1.3.6.1.4.1.534.6.6.6.1.1.15 | DisplayString | accessible-for-notify | The group record being operated on |
| groups | 1.3.6.1.4.1.534.6.6.6.9.2 | | | |
| I32 hardwareRev | 1.3.6.1.4.1.534.6.6.6.1.1.7 | Integer32 | read-only | The hardware revision number. |
| REL humidity | 1.3.6.1.4.1.534.6.6.6.2.4.1.3 | RelativeHumidity | read-only | The value of the external humidity sensor reported
as relative humidity (a percentage). |
| REL humidityLowerCritical | 1.3.6.1.4.1.534.6.6.6.2.4.1.6 | RelativeHumidity | read-write | The value of the lower critical threshold. |
| REL humidityLowerCriticalReset | 1.3.6.1.4.1.534.6.6.6.2.4.1.10 | RelativeHumidity | read-write | The value of the lower critical reset/hysteresis value. |
| REL humidityLowerWarning | 1.3.6.1.4.1.534.6.6.6.2.4.1.4 | RelativeHumidity | read-write | The value of the lower warning (non-critical) threshold. |
| REL humidityLowerWarningReset | 1.3.6.1.4.1.534.6.6.6.2.4.1.8 | RelativeHumidity | read-write | The value of the lower warning (non-critical) reset/hysteresis value. |
| I32 humiditySensorCount | 1.3.6.1.4.1.534.6.6.6.2.3 | Integer32 | read-only | The number of external humidity sensors (regardless of
their current state) present on this pdu. |
| humiditySensorEntry | 1.3.6.1.4.1.534.6.6.6.2.4.1 | | not-accessible | An entry containing sensor reading and threshold
settings for a particular humidity sensor. |
| I32 humiditySensorIndex | 1.3.6.1.4.1.534.6.6.6.2.4.1.1 | Integer32 | not-accessible | A unique value for each humidity sensor. Its value
ranges between 1 and humiditySensorCount. |
| STR humiditySensorLabel | 1.3.6.1.4.1.534.6.6.6.2.4.1.2 | DisplayString | read-write | A settable human-readable label for the external humidity
sensor. One possible use for this label is to convey sensor
location. |
| humiditySensorTable | 1.3.6.1.4.1.534.6.6.6.2.4 | | not-accessible | A list of humidity sensor entries. The number of
entries is given by the value of humiditySensorCount. |
| REL humidityUpperCritical | 1.3.6.1.4.1.534.6.6.6.2.4.1.7 | RelativeHumidity | read-write | The value of the upper critical threshold. |
| REL humidityUpperCriticalReset | 1.3.6.1.4.1.534.6.6.6.2.4.1.11 | RelativeHumidity | read-write | The value of the upper critical reset/hysteresis value. |
| REL humidityUpperWarning | 1.3.6.1.4.1.534.6.6.6.2.4.1.5 | RelativeHumidity | read-write | The value of the upper warning (non-critical) threshold. |
| REL humidityUpperWarningReset | 1.3.6.1.4.1.534.6.6.6.2.4.1.9 | RelativeHumidity | read-write | The value of the upper warning (non-critical) reset/hysteresis value. |
| STR imageVersion | 1.3.6.1.4.1.534.6.6.6.1.1.18 | DisplayString | accessible-for-notify | The version of the Upgrade image |
| info | 1.3.6.1.4.1.534.6.6.6.1.1 | | | |
| infoGroup | 1.3.6.1.4.1.534.6.6.6.9.2.1 | | | A collection of objects providing basic information
about the pdu. |
| IP ipAddress | 1.3.6.1.4.1.534.6.6.6.1.1.3 | IpAddress | read-only | The current IP address. A value of 0.0.0.0 indicates an error
or an unset option. |
| NTF logFileCleared | 1.3.6.1.4.1.534.6.6.6.0.41 | | | The log file has been cleared. |
| MAC mac | 1.3.6.1.4.1.534.6.6.6.1.1.6 | MacAddress | read-only | The current MAC address. |
| IP netmask | 1.3.6.1.4.1.534.6.6.6.1.1.4 | IpAddress | read-only | The current Netmask. A value of 0.0.0.0 indicates an error
or an unset option. |
| STR objectInstance | 1.3.6.1.4.1.534.6.6.6.1.1.13 | DisplayString | accessible-for-notify | The device name |
| STR objectName | 1.3.6.1.4.1.534.6.6.6.1.1.12 | DisplayString | accessible-for-notify | The model type of the device |
| WAT outletActivePower | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.7 | Watts | read-only | A unique value for the active power sensor
attached to the outlet. This value is
reported in Watts. |
| VOL outletApparentPower | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.8 | VoltAmps | read-only | A unique value for the apparent power sensor
attached to the outlet. This value is
reported in Volt-Amps |
| I32 outletCount | 1.3.6.1.4.1.534.6.6.6.1.2.1 | Integer32 | read-only | The number of outlets (regardless of
their current state) present on this pdu. |
| MIL outletCurrent | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.4 | MilliAmps | read-only | A unique value for the current sensor
attached to the outlet. This value is
reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentUpperCritical | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.23 | MilliAmps | read-write | The value of the upper critical current
threshold for the outlet. This value is
reported in milliamps (1/1000th of an amp) |
| MIL outletCurrentUpperWarning | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.21 | MilliAmps | read-write | The value of the upper warning (non-critical)
current threshold for the outlet. This value is
reported in milliamps (1/1000th of an amp) |
| outletEntry | 1.3.6.1.4.1.534.6.6.6.1.2.2.1 | | not-accessible | An outlet entry containing objects at the
for a particular outlet. |
| NTF outletGroupingConnectivityLost | 1.3.6.1.4.1.534.6.6.6.0.50 | | | Master PDU lost contact with the slave PDU in an outlet grouping configuration. |
| I32 outletIndex | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.1 | Integer32 | not-accessible | A unique value for each outlet. Its value
ranges between 1 and the value of outletCount. |
| STR outletLabel | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.2 | DisplayString | read-write | A textual string containing information
about the outlet. |
| MIL outletMaxCurrent | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.5 | MilliAmps | read-only | A unique value for the max. current sensor
attached to the outlet. This value is
reported in milliamps (1/1000th of an amp) |
| INT outletOperationalState | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.3 | INTEGER | read-write | A value for each outlet which describes the
operational state of the outlet. It is also
used to set the operational state of the outlet |
| POW outletPowerFactor | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.9 | PowerFactorPercentage | read-only | A unique value for the power factor
of the outlet. The reading represents a
percentage in the range of 0% to 100%. |
| outlets | 1.3.6.1.4.1.534.6.6.6.1.2 | | | |
| outletsGroup | 1.3.6.1.4.1.534.6.6.6.9.2.2 | | | A collection of objects providing basic information
about the outlets, including sensor readings. |
| outletTable | 1.3.6.1.4.1.534.6.6.6.1.2.2 | | not-accessible | A list of outlet entries. The number of
entries is given by the value of outletCount. |
| MIL outletVoltage | 1.3.6.1.4.1.534.6.6.6.1.2.2.1.6 | MilliVolts | read-only | A unique value for the voltage sensor
attached to the outlet.This value is
reported in millivolts (1/1000th of a volt) |
| NTF passwordSettingsChanged | 1.3.6.1.4.1.534.6.6.6.0.28 | | | Strong password settings changed |
| NTF powerControl | 1.3.6.1.4.1.534.6.6.6.0.23 | | | An outlet has been switched |
| NTF rebootCompleted | 1.3.6.1.4.1.534.6.6.6.0.2 | | | The reboot process is complete |
| NTF rebootStarted | 1.3.6.1.4.1.534.6.6.6.0.1 | | | The reboot process has started |
| NTF securityViolation | 1.3.6.1.4.1.534.6.6.6.0.39 | | | Security violation. |
| STR sensorDescr | 1.3.6.1.4.1.534.6.6.6.1.1.19 | DisplayString | accessible-for-notify | Sensor description indicating which sensor experienced a threshold exceeded
event. When applicable the description will indicate the sensor number. |
| STR serialNumber | 1.3.6.1.4.1.534.6.6.6.1.1.2 | DisplayString | read-only | The serial number. |
| IP slaveIpAddress | 1.3.6.1.4.1.534.6.6.6.1.1.24 | IpAddress | read-only | In a shepherding configuration, this is the IP address of slave PDU. A value of 0.0.0.0 indicates an error
or an unset option. |
| STR status | 1.3.6.1.4.1.534.6.6.6.1.1.23 | DisplayString | accessible-for-notify | The success status of an operation |
| STR targetUser | 1.3.6.1.4.1.534.6.6.6.1.1.14 | DisplayString | accessible-for-notify | The user record being operated on |
| DEG temperature | 1.3.6.1.4.1.534.6.6.6.2.2.1.3 | DegreesCelsius | read-only | The value of the external temperature sensor reported
in degrees celsius. |
| DEG tempLowerCritical | 1.3.6.1.4.1.534.6.6.6.2.2.1.6 | DegreesCelsius | read-write | The value of the lower critical threshold. |
| DEG tempLowerCriticalReset | 1.3.6.1.4.1.534.6.6.6.2.2.1.10 | DegreesCelsius | read-write | The value of the lower critical reset/hysteresis value. |
| DEG tempLowerWarning | 1.3.6.1.4.1.534.6.6.6.2.2.1.4 | DegreesCelsius | read-write | The value of the lower warning (non-critical) threshold. |
| DEG tempLowerWarningReset | 1.3.6.1.4.1.534.6.6.6.2.2.1.8 | DegreesCelsius | read-write | The value of the lower warning (non-critical) reset/hysteresis value. |
| I32 tempSensorCount | 1.3.6.1.4.1.534.6.6.6.2.1 | Integer32 | read-only | The number of external temperature sensors (regardless of
their current state) present on this pdu. |
| tempSensorEntry | 1.3.6.1.4.1.534.6.6.6.2.2.1 | | not-accessible | An entry containing sensor reading and threshold
settings for a particular temperature sensor. |
| I32 tempSensorIndex | 1.3.6.1.4.1.534.6.6.6.2.2.1.1 | Integer32 | not-accessible | A unique value for each temperature sensor. Its value
ranges between 1 and tempSensorCount. |
| STR tempSensorLabel | 1.3.6.1.4.1.534.6.6.6.2.2.1.2 | DisplayString | read-write | A settable human-readable label for the external temperature
sensor. One possible use for this label is to convey sensor
location. |
| tempSensorTable | 1.3.6.1.4.1.534.6.6.6.2.2 | | not-accessible | A list of temperature sensor entries. The number of
entries is given by the value of tempSensorCount. |
| DEG tempUpperCritical | 1.3.6.1.4.1.534.6.6.6.2.2.1.7 | DegreesCelsius | read-write | The value of the upper critical threshold. |
| DEG tempUpperCriticalReset | 1.3.6.1.4.1.534.6.6.6.2.2.1.11 | DegreesCelsius | read-write | The value of the upper critical reset/hysteresis value. |
| DEG tempUpperWarning | 1.3.6.1.4.1.534.6.6.6.2.2.1.5 | DegreesCelsius | read-write | The value of the upper warning (non-critical) threshold. |
| DEG tempUpperWarningReset | 1.3.6.1.4.1.534.6.6.6.2.2.1.9 | DegreesCelsius | read-write | The value of the upper warning (non-critical) reset/hysteresis value. |
| NTF thresholdAlarm | 1.3.6.1.4.1.534.6.6.6.0.45 | | | Configured sensor theshold event. The 'thresholdType' variable will indicate whether or not
the threshold triggered or cleared |
| STR thresholdDescr | 1.3.6.1.4.1.534.6.6.6.1.1.20 | DisplayString | accessible-for-notify | Threshold description indicating which configured threshold has been triggered (or cleared). |
| STR thresholdEventType | 1.3.6.1.4.1.534.6.6.6.1.1.22 | DisplayString | accessible-for-notify | String (triggered, cleared) indicating if the threshold event indicates that a configured threshold
has been triggered or cleared. |
| STR thresholdSeverity | 1.3.6.1.4.1.534.6.6.6.1.1.21 | DisplayString | accessible-for-notify | String (Warning, Critical, etc...) indicating the severity of the threshold which has been triggered (or cleared). |
| traps | 1.3.6.1.4.1.534.6.6.6.0 | | | |
| trapsGroup | 1.3.6.1.4.1.534.6.6.6.9.2.9 | | | A collection of traps. |
| unit | 1.3.6.1.4.1.534.6.6.6.1.3 | | | |
| WAT unitActivePower | 1.3.6.1.4.1.534.6.6.6.1.3.1.3 | Watts | read-only | The value for the unit's voltage sensor in volt-amps. |
| WAT unitApparentPower | 1.3.6.1.4.1.534.6.6.6.1.3.1.4 | Watts | read-only | The value for the unit's voltage sensor in volt-amps. |
| MIL unitCircuitBreak0Current | 1.3.6.1.4.1.534.6.6.6.1.3.1.40 | MilliAmps | read-only | The value for the unit's circuit breaker current sensor 0. |
| INT unitCircuitBreak0State | 1.3.6.1.4.1.534.6.6.6.1.3.1.20 | INTEGER | read-only | The value for the unit's circuit breaker state sensor 0. |
| MIL unitCircuitBreak1Current | 1.3.6.1.4.1.534.6.6.6.1.3.1.41 | MilliAmps | read-only | The value for the unit's circuit breaker current sensor 1. |
| INT unitCircuitBreak1State | 1.3.6.1.4.1.534.6.6.6.1.3.1.21 | INTEGER | read-only | The value for the unit's circuit breaker state sensor 1. |
| MIL unitCircuitBreak2Current | 1.3.6.1.4.1.534.6.6.6.1.3.1.42 | MilliAmps | read-only | The value for the unit's circuit breaker current sensor 2. |
| INT unitCircuitBreak2State | 1.3.6.1.4.1.534.6.6.6.1.3.1.22 | INTEGER | read-only | The value for the unit's circuit breaker state sensor 2. |
| DEG unitCpuTemp | 1.3.6.1.4.1.534.6.6.6.1.3.1.5 | DegreesCelsius | read-only | The value for the unit's CPU temperature sensor in degrees Celsius. |
| MIL unitCurrent | 1.3.6.1.4.1.534.6.6.6.1.3.1.1 | MilliAmps | read-only | The value for the unit's current sensor in millamps. |
| MIL unitCurrentUpperCritical | 1.3.6.1.4.1.534.6.6.6.1.3.1.71 | MilliAmps | read-only | The value of the upper critical unit level current threshold. NOTE: This
particular threshold is NOT settable |
| MIL unitCurrentUpperWarning | 1.3.6.1.4.1.534.6.6.6.1.3.1.70 | MilliAmps | read-write | The value of the upper warning (non-critical) unit level current threshold. |
| unitReadings | 1.3.6.1.4.1.534.6.6.6.1.3.1 | | | |
| unitSensorsGroup | 1.3.6.1.4.1.534.6.6.6.9.2.4 | | | A collection of objects providing unit level sensor readings. |
| DEG unitTempLowerCritical | 1.3.6.1.4.1.534.6.6.6.1.3.1.81 | DegreesCelsius | read-write | The value of the lower critical unit level temperature threshold. |
| DEG unitTempLowerWarning | 1.3.6.1.4.1.534.6.6.6.1.3.1.80 | DegreesCelsius | read-write | The value of the lower warning (non-critical) unit level temperature threshold. |
| DEG unitTempUpperCritical | 1.3.6.1.4.1.534.6.6.6.1.3.1.83 | DegreesCelsius | read-write | The value of the upper critical unit level temperature threshold. |
| DEG unitTempUpperWarning | 1.3.6.1.4.1.534.6.6.6.1.3.1.82 | DegreesCelsius | read-write | The value of the upper warning (non-critical) unit level temperature threshold. |
| MIL unitVoltage | 1.3.6.1.4.1.534.6.6.6.1.3.1.2 | MilliVolts | read-only | The value for the unit's voltage sensor in millivolts. |
| MIL unitVoltageLowerCritical | 1.3.6.1.4.1.534.6.6.6.1.3.1.61 | MilliVolts | read-write | The value of the lower critical unit level voltage threshold. |
| MIL unitVoltageLowerWarning | 1.3.6.1.4.1.534.6.6.6.1.3.1.60 | MilliVolts | read-write | The value of the lower warning (non-critical) unit level voltage threshold. |
| MIL unitVoltageUpperCritical | 1.3.6.1.4.1.534.6.6.6.1.3.1.63 | MilliVolts | read-write | The value of the upper critical unit level voltage threshold. |
| MIL unitVoltageUpperWarning | 1.3.6.1.4.1.534.6.6.6.1.3.1.62 | MilliVolts | read-write | The value of the upper warning (non-critical) unit level voltage threshold. |
| NTF userAdded | 1.3.6.1.4.1.534.6.6.6.0.11 | | | A user was added to the system |
| NTF userAuthenticationFailure | 1.3.6.1.4.1.534.6.6.6.0.5 | | | A user authentication attempt failed |
| NTF userBlocked | 1.3.6.1.4.1.534.6.6.6.0.22 | | | A blocked user tried to log in |
| NTF userDeleted | 1.3.6.1.4.1.534.6.6.6.0.13 | | | A user was deleted from the system |
| NTF userLogin | 1.3.6.1.4.1.534.6.6.6.0.3 | | | A user logged in |
| NTF userLogout | 1.3.6.1.4.1.534.6.6.6.0.4 | | | A user logged out |
| NTF userModified | 1.3.6.1.4.1.534.6.6.6.0.12 | | | A user account was modified |
| STR userName | 1.3.6.1.4.1.534.6.6.6.1.1.10 | DisplayString | accessible-for-notify | The login of a user. |
| NTF userPasswordChanged | 1.3.6.1.4.1.534.6.6.6.0.24 | | | A user password was changed |
| NTF userSessionTimeout | 1.3.6.1.4.1.534.6.6.6.0.8 | | | A user timed out from the device |