All MIBs › DKSF-50-8-1-A-X
Organization: Alentis Electronics
Last Updated: 2010-04-14
Category: Domain: Environmental Monitoring, Vendor: NetPing/DKSF
Description: MIB for DKSF-50 NetPing device firmware 8.1 variant A providing sensor and relay management objects.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is DKSF-50-8-1-A-X?
This is a generic NetPing MIB (used by the DKSF-50-8-1-A-X firmware variant) for remote sensing and control devices that combine IP-based power/relay control with environmental sensors. It exposes a power/relay control table for managing reset/reboot channels and a thermometer table for temperature sensor readings, alongside counters tracking how often resets have occurred. As a monitoring module it directly supports hardware status monitoring: tracking ambient/cabinet temperature via its thermal sensor inputs, and tracking the power-cycling behavior (manual mode, reset counts) of whatever equipment is plugged into its controlled outlets. It defines its own private object structure (npPwr, npThermo, lightcom) without an evident dependency on other standard MIBs beyond generic SNMP conventions. It is deployed in server rooms, comms cabinets, or remote sites where DKSF-50-8-1-A-X SNMP monitoring provides remote power-cycling control and basic environmental monitoring for connected equipment via a NetPing unit.
IPNetwork Monitor allows you to monitor SNMP objects defined in DKSF-50-8-1-A-X. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- NetPing DKSF-50-8-1-A-X IP-based remote power/relay and sensor controller
Monitoring Examples
Polling npThermoTable entries -- npThermoSensorN and npThermoValue -- lets an administrator track cabinet or ambient temperature per sensor channel and catch a cooling failure before it damages equipment. Separately, npPwrTable exposes per-channel control (npPwrChannelN, npPwrManualMode, npPwrStartReset) and reset counters (npPwrResetsCounter, npPwrRepeatingResetsCounter); a rapidly climbing npPwrRepeatingResetsCounter would indicate a connected device stuck in a boot loop that the NetPing unit keeps power-cycling.
What Can Be Monitored
- temperature sensor readings
- power/relay channel state
- manual control mode
- reset/reboot counters
- repeating reset counter
Imported Objects
From RFC1155-SMI
| enterprises |
From SNMPv2-MIB
| snmpTraps | OBJECT-IDENTITY |
From SNMPv2-SMI
| Counter32 | |
| Counter64 | |
| Gauge32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| TimeTicks | |
| mib-2 |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TimeStamp | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using npRelHumSensorStatus OID:
OIDs
RFC description
Generic MIB for NetPing remote sensing and control devices with power outlet/relay management.
Start monitoring NetPing DKSF-50 IP-based remote power/relay and sensor controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.