DKSF-70-4-X-X-1

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsDKSF-70-4-X-X-1

Organization: Alentis Electronics

Last Updated: 2015-05-29

Category: Domain: Environmental Monitoring, Vendor: NetPing/DKSF

Description: MIB for DKSF-70 NetPing device firmware 4.x providing environmental sensor monitoring and relay control.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is DKSF-70-4-X-X-1?

This MIB module belongs to NetPing, a Russian manufacturer of network-attached environmental sensing and relay-control devices, and it targets the DKSF-70 model running firmware version 4.x. It exposes data organized around two general categories: relay control outputs and thermal sensor inputs, alongside trap notification configuration. From a monitoring standpoint, it is used to track the hardware status of the device's temperature sensors (npThermoValue readings from up to several probes) and the operational state of its relays, which are often wired to door contacts, power switches, or environmental alarms. There is no strong dependency on other standard MIBs beyond the generic SNMPv2-SMI conventions, as this is a self-contained vendor MIB under the 'lightcom' enterprise branch. It is typically deployed in server rooms, telecom closets, or industrial cabinets where a small embedded device provides low-cost remote environmental monitoring and remote power/relay control over SNMP. Engineers can download the DKSF-70-4-X-X-1 file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in DKSF-70-4-X-X-1. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • NetPing DKSF-70 environmental sensor/relay controller

Monitoring Examples

An administrator would poll npThermoTable/npThermoEntry columns such as npThermoSensorN and npThermoValue to track ambient temperature at each connected probe, alerting if a reading exceeds a safe threshold indicating cooling failure in a rack. The npRelayTable/npRelayEntry with npRelayState and npRelayMode lets the admin confirm whether a relay (e.g., controlling a fan, UPS bypass, or door lock) is currently open or closed and whether it is in automatic or manual mode. npTrapEmailTo and npTrapInfo configure where alert emails are sent when a threshold or relay state change trap fires, and npRelayStartReset lets an operator remotely cycle power on a stuck device.

What Can Be Monitored

  • thermal sensor temperature readings
  • relay open/closed state
  • relay operating mode
  • relay reset/power-cycle status
  • trap email notification target
  • number of active thermo sensors
Imported Objects

From SNMPv2-MIB

snmpTrapsOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Counter64
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks
enterprises

From SNMPv2-TC

DisplayString
TEXTUAL-CONVENTION
TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using npIoPulseCounter OID:

Select a NetPing DKSF-70 environmental sensor/relay controller as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type npIoPulseCounter into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the pulse Counter on IO input line (counts positive fronts) Write 0 to reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages NetPing remote sensing and control devices with relay modes, IO lines, humidity sensors, and current loop monitoring.

Start monitoring NetPing DKSF-70 environmental sensor/relay controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download DKSF-70-4-X-X-1