All MIBs › Cisco90Series-MIB
Category: IP Routing
Description: Provides management objects for the Cisco 90 series router and access server platforms.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is Cisco90Series-MIB?
This is a legacy vendor-specific MIB module identifying the Cisco 90 series of routers/access servers within Cisco's proprietary OID tree. No populated object list is available in the source data, but such series-identification MIBs in Cisco's structure typically just define OID branches used elsewhere (e.g., for sysObjectID) to identify a hardware model, rather than exposing runtime telemetry themselves. It would not itself carry environmental, performance, or fault data; that data would instead come from generic Cisco MIBs (e.g., OLD-CISCO-CPU-MIB, ENTITY-MIB) applied to a device identified as this model. No dependency information is available from the source beyond its place in Cisco's proprietary product tree. Deployment context is identifying Cisco 90-series router/access-server hardware within an NMS inventory. Engineers can download the Cisco90Series-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in Cisco90Series-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Cisco 90 series router/access server
Monitoring Examples
No sample objects were provided for this MIB in the source data. This appears to be a product-identification/registration module with no runtime data objects, typically referenced via sysObjectID to identify the device model rather than polled directly for monitoring data.
This MIB depends on
Related MIBs
Imported Objects
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ciscoTelesend | 1.3.6.1.4.1.1570 | |||
| frMux | 1.3.6.1.4.1.1570.1 | |||
| NTF frxDownloadTrap | 1.3.6.1.4.1.1570.1.0.1 | This trap is sent if the Download Config pushbutton on the channel unit faceplate is pushed and frxDefaultTrap is set to 1. | ||
| NTF frxUPerfTrap | 1.3.6.1.4.1.1570.1.0.2 | This trap is sent if a performance monitoring threshold on a channel unit or a BRITE card is exceeded and the corresponding bit in the frxAlertMask is enabled and frxUPerfTrapEnable is enabled. The manager should read and clear all of the threshold condition registers for the specified channel unit to enable the trap to be sent again. | ||
| NTF frxInsertChUTrap | 1.3.6.1.4.1.1570.1.0.3 | This trap is sent when the channel unit is inserted. | ||
| NTF frxRemoveChUTrap | 1.3.6.1.4.1.1570.1.0.4 | This trap is sent when the channel unit is removed. | ||
| NTF frxDConfigFailed | 1.3.6.1.4.1.1570.1.0.5 | This trap is sent if downloading configuration data to a channel unit fails. | ||
| frxSys | 1.3.6.1.4.1.1570.1.1 | |||
| STR frxSysDescr | 1.3.6.1.4.1.1570.1.1.1 | DisplayString | read-only | Description of the Cisco 90 Series System. |
| INT frxClockHour | 1.3.6.1.4.1.1570.1.1.2 | INTEGER | read-write | Synchronized 24 hour clock for the Cisco 90 Series system - Hour. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals. |
| INT frxClockMin | 1.3.6.1.4.1.1570.1.1.3 | INTEGER | read-write | Synchronized 24 hour clock for the Cisco 90 Series system - Minutes. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals. |
| INT frxClockSec | 1.3.6.1.4.1.1570.1.1.4 | INTEGER | read-write | Synchronized 24 hour clock for the Cisco 90 Series system - Seconds. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals. |
| TIK frxUpTime | 1.3.6.1.4.1.1570.1.1.5 | TimeTicks | read-only | Time since the agent was last initialized in 0.01 second increments. |
| STR frxAdminContact | 1.3.6.1.4.1.1570.1.1.6 | DisplayString | read-write | Cisco 90 Series administrative contact name. |
| STR frxSysName | 1.3.6.1.4.1.1570.1.1.7 | DisplayString | read-write | Administratively assigned name for this Cisco 90 Series agent. |
| STR frxSysLoc | 1.3.6.1.4.1.1570.1.1.8 | DisplayString | read-write | Physical location of the Cisco 90 Series agent. |
| INT frxSysVersion | 1.3.6.1.4.1.1570.1.1.9 | INTEGER | read-only | Cisco 90 Series Agent version number. The version number is an INTEGER representation of the actual version number string. The way to translate to a version number string is 200 = 2.0.0, 201 = 2.0.1, etc. |
| INT frxUPerfTrapEnable | 1.3.6.1.4.1.1570.1.1.10 | INTEGER | read-write | 1=Enable sending the frxUPerfTrap trap to the SNMP manager when a performance monitoring threshold is crossed at an Cisco 90 Series channel unit or a downstream BRITE card. 2=Disable Trap. |
| CTR frxAgtLinkErrors | 1.3.6.1.4.1.1570.1.1.11 | Counter | read-only | Number of Annex-D signaling link reliability errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling reliability error is declared whenever the Cisco 90 Series Agent did not receive a reply from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry poll |
| CTR frxAgtProtErrors | 1.3.6.1.4.1.1570.1.1.12 | Counter | read-only | Number of Annex-D signaling protocol errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling protocol error is declared whenever the Cisco 90 Series Agent receives a reply with incorrect format or sequence numbers from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry poll |
| CTR frxAgtChInactive | 1.3.6.1.4.1.1570.1.1.13 | Counter | read-only | Number of times the Cisco 90 Series Agent Annex-D signaling channel was declared inactive. |
| INT frxAgtChStatus | 1.3.6.1.4.1.1570.1.1.14 | INTEGER | read-only | Current status of the Annex-D signaling channel between the Cisco 90 Series Agent and the Frame Relay Switch. |
| frxDefault | 1.3.6.1.4.1.1570.1.2 | |||
| INT frxDefaultEnable | 1.3.6.1.4.1.1570.1.2.1 | INTEGER | read-write | 1=Enable automatic loading of defaults (defined in this group) to the channel unit when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable loading. |
| INT frxDefaultTrap | 1.3.6.1.4.1.1570.1.2.2 | INTEGER | read-write | 1=Enable sending the frxDownloadTrap trap to the SNMP manager when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable Trap |
| INT frxDConfigSrc | 1.3.6.1.4.1.1570.1.2.3 | INTEGER | read-write | System default for frxConfigSrc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Data rate and protocol set by Annex-D assignment rules. 2=Data rate and protocol set by the SNMP variables frxPortSpeed and frxPortProtocol |
| INT frxDMgtT391 | 1.3.6.1.4.1.1570.1.2.4 | INTEGER | read-write | System Default for frxMgtT391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often (in seconds) the channel units send an Annex-D poll to the frame relay switch. This is the Annex-D T391 parameter (Typical value 10) |
| INT frxDMgtT392 | 1.3.6.1.4.1.1570.1.2.5 | INTEGER | read-write | System Default for frxMgtT392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15) |
| INT frxDMgtN391 | 1.3.6.1.4.1.1570.1.2.6 | INTEGER | read-write | System Default for frxMgtN391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often the channel units send a full status inquiry poll to the frame relay switch instead of a link integrity verification poll. This is the Annex-D N391 parameter (Typical value 6) |
| INT frxDMgtN392 | 1.3.6.1.4.1.1570.1.2.7 | INTEGER | read-write | System Default for frxMgtN392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3) |
| INT frxDMgtN393 | 1.3.6.1.4.1.1570.1.2.8 | INTEGER | read-write | System Default for frxMgtN393 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N393 parameter (Typical value 4) |
| INT frxDPortSpeed | 1.3.6.1.4.1.1570.1.2.9 | INTEGER | read-write | System Default for frxPortSpeed - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144kbps |
| INT frxDPortProtocol | 1.3.6.1.4.1.1570.1.2.10 | INTEGER | read-write | System Default for frxPortProtocol - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Port uses Frame Relay protocol 2=Port uses PPP protocol - do RFC-1973 encapsulation |
| INT frxDCktCIR | 1.3.6.1.4.1.1570.1.2.11 | INTEGER | read-write | System Default for frxCktCIR - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed information rate (CIR) in bits per second. (Typical value 1536000/#ports) |
| INT frxDCktBc | 1.3.6.1.4.1.1570.1.2.12 | INTEGER | read-write | System Default for frxCktBc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed BurstSize (Bc) in bits. The time interval over which the burst is measured is Bc/CIR. (Typically set to same number as frxDCktCIR). |
| INT frxDCktBe | 1.3.6.1.4.1.1570.1.2.13 | INTEGER | read-write | System Default for frxCktBe - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the excess BurstSize (Be) in bits. The time interval over which the excess burst is measured is Be/CIR. (Typical value 1536000). |
| frxBank | 1.3.6.1.4.1.1570.1.3 | |||
| frxBankTable | 1.3.6.1.4.1.1570.1.3.1 | not-accessible | This Cisco 90 Series Bank Di-group Table contains channel bank level information for each of the channel bank di-groups in the system. A di-group is a T1 interface to the frame relay network. The table is indexed using the Cisco 90 Series channel bank digroup number | |
| frxBankEntry | 1.3.6.1.4.1.1570.1.3.1.1 | not-accessible | A specific entry in the Cisco 90 Series Bank Di-group Table. There is one entry for each channel bank di-group (T1) in the system. There are no entries for unused banks | |
| INT frxBankIndex | 1.3.6.1.4.1.1570.1.3.1.1.1 | INTEGER | read-only | Channel Bank Di-group Number. This index is used to address the various channel banks in the system. This number is the same as the DLCI number used to communicate with the bank at the Cisco 90 SNMP Agent. (note that this is NOT the same as the DLCI number at the channel bank. The channel bank always uses DLCI 30 or 31 to communicate with the Agent.) |
| INT frxBankType | 1.3.6.1.4.1.1570.1.3.1.1.2 | INTEGER | read-write | This is the type of channel bank and is for future use. D4 banks return a value of 1. |
| frxChUnit | 1.3.6.1.4.1.1570.1.4 | |||
| frxChUTable | 1.3.6.1.4.1.1570.1.4.1 | not-accessible | This Cisco 90 Series Channel Unit Table contains channel unit level control and statistics for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24). | |
| frxChUEntry | 1.3.6.1.4.1.1570.1.4.1.1 | not-accessible | A specific entry in the Cisco 90 Series Channel Unit Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots | |
| INT frxChUIndex | 1.3.6.1.4.1.1570.1.4.1.1.1 | INTEGER | read-only | Channel Unit Number. This index is used to address a specific channel unit in a bank. For D4 channel banks this number is the same as the physical slot number 1-24 |
| INT frxChUType | 1.3.6.1.4.1.1570.1.4.1.1.2 | INTEGER | read-only | Type of Cisco 90 Series channel unit installed. |
| INT frxChUVersion | 1.3.6.1.4.1.1570.1.4.1.1.3 | INTEGER | read-only | Cisco 90 Series channel unit version number. |
| INT frxSigProtocol | 1.3.6.1.4.1.1570.1.4.1.1.4 | INTEGER | read-only | This is the type of Local In-channel Signaling used when the subscriber is running frame relay protocol. It is provided for future use. Set to 1 for T1.617 Annex-D |
| INT frxConfigSrc | 1.3.6.1.4.1.1570.1.4.1.1.5 | INTEGER | read-write | Source for configuring speed and protocol for each port. 1=Data rate and protocol set by DLCI assignment rules as reported by Annex-D. This option allows control of these basic parameters from the frame relay switch management station instead of the Cisco 90 Series management station. 2=Data rate and protocol set by SNMP variables frxPortSpeed and frxPortProtocol |
| INT frxDLCIAdLen | 1.3.6.1.4.1.1570.1.4.1.1.6 | INTEGER | read-only | The number of bytes used for the DLCI address. For future use. 1=two octets. |
| CTR frxNetInOctets | 1.3.6.1.4.1.1570.1.4.1.1.7 | Counter | read-only | Total number of octets received by this channel unit from Frame Relay Switch (on the T1 interface) Only frames whose DLCI is addressed to a port on this channel unit are counted. Bad frames, Annex-D and SNMP frames are not counted. CRC bytes are not counted |
| CTR frxNetOutOctets | 1.3.6.1.4.1.1570.1.4.1.1.8 | Counter | read-only | Total number of octets transmitted to the Frame Relay Switch (on the T1 interface) by this channel unit. Annex-D and SNMP frames are not counted. CRC bytes are not counted |
| CTR frxNetBadFrames | 1.3.6.1.4.1.1570.1.4.1.1.9 | Counter | read-only | Total number of frames received on the network (T1) interface that are discarded by this channel unit. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Frame was too short (less than 5 bytes) Frame was too long (more than 8192 bytes) Frame had bad RFC-1973 (PPP) header - this error only occurs if destination port is set for PPP protocol. Frame was discarded due to lack of buffer space. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetHDLCEs | 1.3.6.1.4.1.1570.1.4.1.1.10 | Counter | read-only | Network Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetCRCEs | 1.3.6.1.4.1.1570.1.4.1.1.11 | Counter | read-only | Network Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetLinkEs | 1.3.6.1.4.1.1570.1.4.1.1.12 | Counter | read-only | Network Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetFrShEs | 1.3.6.1.4.1.1570.1.4.1.1.13 | Counter | read-only | Network Errored Seconds caused by Short Frames received. Total number of seconds in which a frame that is too short (less than 5 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetFrLgEs | 1.3.6.1.4.1.1570.1.4.1.1.14 | Counter | read-only | Network Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| CTR frxNetPPPEs | 1.3.6.1.4.1.1570.1.4.1.1.15 | Counter | read-only | Errored seconds caused by bad RFC-1973 (PPP) header. Total number of seconds in which a frame with an invalid RFC-1973 (PPP) header is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port that is set to PPP protocol and is on this channel unit are counted. |
| CTR frxNetBufEs | 1.3.6.1.4.1.1570.1.4.1.1.16 | Counter | read-only | Errored Seconds caused by Buffer Overflow. Total number of seconds in which a frame received by this channel unit on the network (T1) interface was discarded due to insufficient buffer space. Only frames whose DLCI is addressed to a port on this channel unit are counted. |
| frxMgt | 1.3.6.1.4.1.1570.1.5 | |||
| frxMgtTable | 1.3.6.1.4.1.1570.1.5.1 | not-accessible | This table monitors and controls the T1-617 Annex-D parameters used by the channel units. There is one table row for every channel unit in every bank. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24). For best performance, all of the channel units in a given bank should be set to identical values. These values are typically set using global parameters in the frxDefaultTable instead of directly via this table. | |
| frxMgtEntry | 1.3.6.1.4.1.1570.1.5.1.1 | not-accessible | A specific entry in the Cisco 90 Series Management Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots | |
| INT frxPortsInSvc | 1.3.6.1.4.1.1570.1.5.1.1.1 | INTEGER | read-only | Ports in service. The number of ports on a Cisco 90 Series channel unit that have one or more active PVCs, as determined by Annex-D. |
| INT frxMgtT391 | 1.3.6.1.4.1.1570.1.5.1.1.2 | INTEGER | read-write | This controls how often (in seconds) the channel unit sends an Annex-D poll to the frame relay switch. This is the Annex-D T391 parameter (Typical value 10) |
| INT frxMgtT392 | 1.3.6.1.4.1.1570.1.5.1.1.3 | INTEGER | read-write | This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15) |
| INT frxMgtN391 | 1.3.6.1.4.1.1570.1.5.1.1.4 | INTEGER | read-write | This controls how often (in polls) the channel unit sends a full status inquiry poll to the frame relay switch instead of a link integrity verification poll. This is the Annex-D N391 parameter (Typical value 6) |
| INT frxMgtN392 | 1.3.6.1.4.1.1570.1.5.1.1.5 | INTEGER | read-write | When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3) |
| INT frxMgtN393 | 1.3.6.1.4.1.1570.1.5.1.1.6 | INTEGER | read-write | When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N393 parameter (Typical value 4) |
| CTR frxNetLinkErrors | 1.3.6.1.4.1.1570.1.5.1.1.7 | Counter | read-only | Number of signaling link reliability errors from network. A signaling reliability error is declared whenever the channel units did not receive a reply from the frame relay switch to an Annex-D link integrity poll or full status inquiry poll |
| CTR frxNetProtErrors | 1.3.6.1.4.1.1570.1.5.1.1.8 | Counter | read-only | Number of signaling protocol errors from network. A signaling protocol error is declared whenever the channel units receive a reply with incorrect format or sequence numbers from the frame relay switch in response to an Annex-D link integrity poll or full status inquiry poll |
| CTR frxNetChInactive | 1.3.6.1.4.1.1570.1.5.1.1.9 | Counter | read-only | Number of times network Annex-D signaling channel was declared inactive. |
| INT frxNetChStatus | 1.3.6.1.4.1.1570.1.5.1.1.10 | INTEGER | read-only | Current status of the Annex-D signaling channel on the network side of the channel bank. |
| frxMgtPortTable | 1.3.6.1.4.1.1570.1.5.2 | not-accessible | This table monitors the T1-617 Annex-D link between the channel units and the subscribers. There is one table row for every port on every channel unit in every bank. The table is indexed first using the channel bank digroup number, then the channel unit number (1 to 24), and then the port number (0 to 3). | |
| frxMgtPortEntry | 1.3.6.1.4.1.1570.1.5.2.1 | not-accessible | A specific entry in the Cisco 90 Series Management Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots. | |
| INT frxPortIndex | 1.3.6.1.4.1.1570.1.5.2.1.1 | INTEGER | read-only | Which subscriber port on the channel unit is addressed. Ports are numbered from 0 to 3. Some channel unit types have less than 4 ports. |
| CTR frxPortLinkErrors | 1.3.6.1.4.1.1570.1.5.2.1.2 | Counter | read-only | Number of signaling link reliability errors from subscriber port. A signaling reliability error is declared whenever the channel units did not receive an Annex-D link integrity poll or full status inquiry poll from the subscriber port within the required time. |
| CTR frxPortProtErrors | 1.3.6.1.4.1.1570.1.5.2.1.3 | Counter | read-only | Number of signaling protocol errors from subscriber port. A signaling protocol error is declared whenever the channel units receive an Annex-D link integrity poll or full status inquiry poll with incorrect format or sequence numbers from the subscriber port. |
| CTR frxPortChInactive | 1.3.6.1.4.1.1570.1.5.2.1.4 | Counter | read-only | Number of times the subscriber port Annex-D signaling channel was declared inactive |
| frxPort | 1.3.6.1.4.1.1570.1.6 | |||
| frxPortTable | 1.3.6.1.4.1.1570.1.6.1 | not-accessible | This Cisco 90 Series Port Table contains per-port control and statistics for each of the subscriber ports in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit number (1 to 24), and finally by the port number (0-3). | |
| frxPortEntry | 1.3.6.1.4.1.1570.1.6.1.1 | not-accessible | A specific entry in the Cisco 90 Series Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots. | |
| INT frxPortSpeed | 1.3.6.1.4.1.1570.1.6.1.1.1 | INTEGER | read-write | This is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144kbps This parameter can only be changed if frxConfigSrc is set to SNMP. |
| INT frxPortProtocol | 1.3.6.1.4.1.1570.1.6.1.1.2 | INTEGER | read-write | This parameter controls what protocol the channel unit should expect the subscriber to send on the port. 1=Port uses Frame Relay protocol - no encapsulation 2=Port uses PPP protocol - do RFC-1973 encapsulation This parameter can only be changed if frxConfigSrc is set to SNMP. |
| INT frxDSLStatus | 1.3.6.1.4.1.1570.1.6.1.1.3 | INTEGER | read-only | This is the status of the DSL loop to the subscriber. 1=Loop is down. 2=Frx card has achieved physical layer activation with the first BRITE card or the NT1 if there are no BRITE cards. 3=Link is up but Annex-D is still inactive. The ACT bit has been exchanged with the NT1 indicating a clear channel path to the customer has been established. Ports running protocols (i.e. PPP) that do not support Annex-D will never be in this state. 4=Link is fully up. Annex-D (if appropriate) is active. |
| INT frxPVCAssigned | 1.3.6.1.4.1.1570.1.6.1.1.4 | INTEGER | read-only | Number of PVCs assigned to Subscriber Port as determined by Annex-D |
| TIK frxLastChange | 1.3.6.1.4.1.1570.1.6.1.1.5 | TimeTicks | read-only | Time since DSL went in sync or lost sync in 0.01 second increments. |
| INT frxBrite | 1.3.6.1.4.1.1570.1.6.1.1.6 | INTEGER | read-only | Number of BRITE cards downstream. BRITE cards are used to extend the loop over subscriber loop carrier systems and are detected via a background polling operation. |
| CTR frxDSLInOctets | 1.3.6.1.4.1.1570.1.6.1.1.7 | Counter | read-only | Number of octets received from the subscriber DSL Does not include Annex-D octets |
| CTR frxDSLOutOctets | 1.3.6.1.4.1.1570.1.6.1.1.8 | Counter | read-only | Number of octets transmitted to the subscriber DSL. Does not include Annex-D octets |
| CTR frxT1InOctets | 1.3.6.1.4.1.1570.1.6.1.1.9 | Counter | read-only | Number of octets received from the network directed at this subscriber port |
| CTR frxT1OutOctets | 1.3.6.1.4.1.1570.1.6.1.1.10 | Counter | read-only | Number of octets transmitted to the network from this subscriber port |
| CTR frxDSLBadFrames | 1.3.6.1.4.1.1570.1.6.1.1.11 | Counter | read-only | Total number of frames received from this subscriber port that were discarded. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Frame was too short (less than 5 bytes) Frame was too long (more than 8192 bytes) Frame had illegal DLCI (not 16-23) Frame was discarded due to lack of buffer space or due to congestion control |
| CTR frxDSLHDLCEs | 1.3.6.1.4.1.1570.1.6.1.1.12 | Counter | read-only | Subscriber port Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received from this port. |
| CTR frxDSLCRCEs | 1.3.6.1.4.1.1570.1.6.1.1.13 | Counter | read-only | Subscriber port Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received from this port. |
| CTR frxDSLLinkEs | 1.3.6.1.4.1.1570.1.6.1.1.14 | Counter | read-only | Subscriber port Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received from this port. |
| CTR frxDSLFrShEs | 1.3.6.1.4.1.1570.1.6.1.1.15 | Counter | read-only | Subscriber port Errored Seconds caused by Short Frames. received Total number of seconds in which a frame that is too short (less than 5 bytes) is received from this port. |
| CTR frxDSLFrLgEs | 1.3.6.1.4.1.1570.1.6.1.1.16 | Counter | read-only | Subscriber port Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received from this port. |
| CTR frxDSLDLCIEs | 1.3.6.1.4.1.1570.1.6.1.1.17 | Counter | read-only | Subscriber port Errored Seconds caused by illegal DLCI. Total number of seconds in which a frame that has a DLCI other than 16 to 23 (or 0) is received from this port. |
| INT frxTxBuf | 1.3.6.1.4.1.1570.1.6.1.1.18 | INTEGER | read-only | Number of octets in the transmit buffer for this subscriber port. This data is waiting to be sent to the network (T1). |
| INT frxRxBuf | 1.3.6.1.4.1.1570.1.6.1.1.19 | INTEGER | read-only | Number of octets in the receive buffer for this subscriber port. This data is from the network (T1) and is waiting to be sent to the subscriber port. |
| CTR frxPortNetEs | 1.3.6.1.4.1.1570.1.6.1.1.20 | Counter | read-only | Total number of seconds in which a frame received from the network (T1) and targeted at this subscriber port was discarded. |
| frxCircuitTable | 1.3.6.1.4.1.1570.1.6.2 | not-accessible | This Cisco 90 Series Circuit Table contains per-virtual-circuit control and statistics for each of the permanent virtual circuits in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit number (1 to 24), then by the port number (0-3) and finally by the circuit DLCI number (16 to 23). | |
| frxCircuitEntry | 1.3.6.1.4.1.1570.1.6.2.1 | not-accessible | A specific entry in the Cisco 90 Series Circuit Table. There is one entry for each permanent virtual circuit in the system. There are no entries for unused banks or empty channel unit slots. | |
| INT frxPvcIndex | 1.3.6.1.4.1.1570.1.6.2.1.1 | INTEGER | read-only | This index is the subscriber loop DLCI number of the permanent virtual circuit. It ranges from 16 to 23. The corresponding network side DLCI must be assigned in the frame relay switch and communicated to the Cisco 90 Series channel units via the Annex-D protocol before this element can be addressed. |
| INT frxCktCIR | 1.3.6.1.4.1.1570.1.6.2.1.2 | INTEGER | read-write | This is the committed information rate (CIR) in bits per second for the addressed permanent virtual circuit. (Typical value 1536000/#ports). |
| INT frxCktBc | 1.3.6.1.4.1.1570.1.6.2.1.3 | INTEGER | read-write | This is the Committed Burst Size (Bc) in bits for the addressed permanent virtual circuit. The time interval over which the burst is measured is Bc/CIR. (Typically set to same number as frxCktCIR). |
| INT frxCktBe | 1.3.6.1.4.1.1570.1.6.2.1.4 | INTEGER | read-write | This is the Excess Burst Size (Be) in bits for the addressed permanent virtual circuit. The time interval over which the excess burst is measured is Be/CIR. (Typical value 1536000). |
| INT frxFarEndOpStat | 1.3.6.1.4.1.1570.1.6.2.1.5 | INTEGER | read-only | This is the status of the far end of the frame relay permanent virtual circuit (through the frame relay network) as determined by Annex-D. 1=active 2=inactive |
| CTR frxCktInOctets | 1.3.6.1.4.1.1570.1.6.2.1.6 | Counter | read-only | The number of input octets from the subscriber port on the addressed permanent virtual circuit. These octets are destined for the network (T1). |
| CTR frxCktOutOctets | 1.3.6.1.4.1.1570.1.6.2.1.7 | Counter | read-only | The number of output octets to the subscriber port on the addressed permanent virtual circuit. These octets were received from the network (T1). |
| CTR frxCktInFrames | 1.3.6.1.4.1.1570.1.6.2.1.8 | Counter | read-only | The number of input frames from the subscriber port on the addressed permanent virtual circuit. These frames are destined for the network (T1). |
| CTR frxCktOutFrames | 1.3.6.1.4.1.1570.1.6.2.1.9 | Counter | read-only | The number of output frames to the subscriber port on the addressed permanent virtual circuit. These frames were received from the network (T1). |
| CTR frxCktDiscards | 1.3.6.1.4.1.1570.1.6.2.1.10 | Counter | read-only | The number of input frames from the subscriber port on the addressed permanent virtual circuit that were discarded due to congestion (lack of buffer space or congestion control. |
| frxUEocTable | 1.3.6.1.4.1.1570.1.6.3 | not-accessible | This Cisco 90 Series Embedded Operations Channel Table is used to diagnose and sectionalize problems with the subscriber loop. It contains one entry for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24). | |
| frxUEocEntry | 1.3.6.1.4.1.1570.1.6.3.1 | not-accessible | A specific entry in the Cisco 90 Series Embedded Operations Channel Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots | |
| INT frxTestPort | 1.3.6.1.4.1.1570.1.6.3.1.1 | INTEGER | read-write | This parameter indicates which subscriber port on the channel unit to test. It has no effect until frxStartTest is set to start the test. Only one port on a given channel unit may be tested at a time. |
| INT frxTestType | 1.3.6.1.4.1.1570.1.6.3.1.2 | INTEGER | read-write | This parameter indicates the type of test to perform. It has no effect until frxStartTest is set to start the test. 1=Set up a loopback and run a PN-2047 Bit Error Rate Test. 2=Run a (straightaway) PN-2047 Bit Error Rate Test. This test assumes a loopback has been manually set up somewhere downstream or another test set running PN-2047 BERT is connected downstream. 3=Send corrupted CRC on the DSL. This has no effect on the frame relay CRC, only the out-of-band DSL CRC (used for performance monitoring) is corrupted. 4=Set up a loopback at the specified location to loop the frame relay or PPP data in both directions. 5=Setup a local loopback on all 4 ports. frxTestPort and frxLoopLoc are ignored for this test. |
| INT frxLoopLoc | 1.3.6.1.4.1.1570.1.6.3.1.3 | INTEGER | read-write | This parameter indicates the location of the loopback or the card that will send corrupt CRC. It has no effect until frxStartTest is set to start the test. It has no effect for a BertOnly test. 7=Local Cisco 90 Series card 8=NT1 at customer premise 1 to 6 is used to address intervening BRITE cards. |
| INT frxLoopCh | 1.3.6.1.4.1.1570.1.6.3.1.4 | INTEGER | read-write | This parameter indicates which channels to use for the loopbackOnly and localLoopAllPorts test. It has no effect until frxStartTest is set to start the test. Note that the loopbackAndBert test always loops all channels back. 1=B1 channel 2=B2 channel 3=All channels (includes all B channels plus all D channels |
| INT frxStartTest | 1.3.6.1.4.1.1570.1.6.3.1.5 | INTEGER | read-write | This parameter is used to start and stop the test. frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should be set up prior to starting the test. 1=stop test. 2=start test. |
| INT frxBertRst | 1.3.6.1.4.1.1570.1.6.3.1.6 | INTEGER | read-write | This parameter may be used during a LoopbackAndBert test or a BertOnly test to reset the frxBertBE counter. It must be returned to the normal posiion to allow errors to be counted. 1=normal. 2=Reset BERT counter. |
| CTR frxBertBE | 1.3.6.1.4.1.1570.1.6.3.1.7 | Counter | read-only | BERT test block errors |
| TIK frxBertTestTime | 1.3.6.1.4.1.1570.1.6.3.1.8 | TimeTicks | read-only | BERT test time in 0.01 second increments |
| INT frxTestInProg | 1.3.6.1.4.1.1570.1.6.3.1.9 | INTEGER | read-only | Test in progress (1); Normal operation (2) |
| frxUThrTable | 1.3.6.1.4.1.1570.1.6.4 | not-accessible | This table contains the U-interface Performance Monitoring Thresholds and Alarms for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24), then the port number (0, 1, etc) and finally the location number (the BRITE card number (1 to 6) or 7 for local parameters in the Cisco 90 Series card). These registers are defined by Bellcore TR-TSY-000829. | |
| frxUThrEntry | 1.3.6.1.4.1.1570.1.6.4.1 | not-accessible | A specific entry in the U-interface Performance Monitoring Threshold table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused banks or empty channel unit slots | |
| INT frxPAddrIndex | 1.3.6.1.4.1.1570.1.6.4.1.1 | INTEGER | read-only | This is the physical location where the performance monitoring takes place. It may be set to localFrx(7) to access and control PM values local to the Cisco 90 Series channel unit. If there are BRITE cards in the subscriber loop between the Cisco 90 Series channel unit and the customer, PM values contained in those cards may be accessed using briteCard1(1) to briteCard6(6) where briteCard1 is the card closest to the Cisco 90 Series channel unit. |
| INT frxChEsTh | 1.3.6.1.4.1.1570.1.6.4.1.2 | INTEGER | read-write | Current Hour Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 40. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxCdEsTh | 1.3.6.1.4.1.1570.1.6.4.1.3 | INTEGER | read-write | Current Day Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 100. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxChSesTh | 1.3.6.1.4.1.1570.1.6.4.1.4 | INTEGER | read-write | Current Hour Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 10. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxCdSesTh | 1.3.6.1.4.1.1570.1.6.4.1.5 | INTEGER | read-write | Current Day Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxThCond register is set and a trap is generated (depending on the state of frxUPerfTrapEnable). Factory defaut is 25. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxAlertMask | 1.3.6.1.4.1.1570.1.6.4.1.6 | INTEGER | read-write | 8-bit Alert Mask register. One bit for each threshold in both directions. When set to 1, the corresponding threshold crossing is ignored. When set to 0, the corresponding threshold crossing is indicated in frxThCond and may cause a trap to be sent depending on the state of frxUPerfTrapEnable. 1 Current Day Severely Errored Seconds Receive 2 Current Day Severely Errored Seconds Transmit 4 Current Day Errored Seconds Receive 8 Current Day Errored Seconds Receive 16 Current Hour Severely Errored Seconds Receive 32 Current Hour Severely Errored Seconds Transmit 64 Current Hour Errored Seconds Receive 128 Current Hour Errored Seconds Transmit Transmit is data from the customer towards the network. Receive is data from the network towards the Customer. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxThCond | 1.3.6.1.4.1.1570.1.6.4.1.7 | INTEGER | read-write | 8-bit Threshold Condition register. One bit for each threshold in both directions. Set to 1 if the threshold is exceeded and the corresponding bit in the frxAlertMask register is set to 0. Only set to 0 by the SNMP manager. 1 Current Day Severely Errored Seconds Receive 2 Current Day Severely Errored Seconds Transmit 4 Current Day Errored Seconds Receive 8 Current Day Errored Seconds Receive 16 Current Hour Severely Errored Seconds Receive 32 Current Hour Severely Errored Seconds Transmit 64 Current Hour Errored Seconds Receive 128 Current Hour Errored Seconds Transmit Receive is data from the customer towards the network. Transmit is data from the network towards the Customer. SNMP manager should reset bits to 0 after they it has been read by issuing a set using the inverted byte read. Sets will only reset bits where the set data is a 0. Setting a bit to a 1 has no effect. This register is defined by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits are inverted when read relative to that specification so the sense of the bits is the same for sets and gets. Indexed by Bank.ChannelUnit.Port.Address |
| frxUPerfTable | 1.3.6.1.4.1.1570.1.6.5 | not-accessible | This table contains the U-interface Performance Monitoring Statistics for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit number (1 to 24), then the port number (0, 1, etc) and finally the location number (the BRITE card number (1 to 6) or 7 for local parameters in the Cisco 90 Series card). These registers are defined by Bellcore TR-TSY-000829. | |
| frxUPerfEntry | 1.3.6.1.4.1.1570.1.6.5.1 | not-accessible | A specific entry in the U-interface Performance Monitoring Statistics table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused banks or empty channel unit slots | |
| INT frxResetPM | 1.3.6.1.4.1.1570.1.6.5.1.1 | INTEGER | read-write | Reset all of the performance monitoring statistics on the specified Cisco 90 Series channel unit or BRITE card. 1=Normal. 2=Reset. There is no need to set this register back to Normal after doing a reset. |
| INT frxPMtype | 1.3.6.1.4.1.1570.1.6.5.1.2 | INTEGER | read-only | Determines if the Cisco 90 Series channel unit or the downstream BRITE cards is doing segmented or path performance monitoring as specified in Bellcore document TR-NWT-000397. Only segmented performance monitoring should be used. In segmented PM, CRC errors are counted on each segment of the loop, instead of over the entire path. If no BRITE cards exist in the system, there is no difference between segmented and path PM 1=Segmented. 2=Path. |
| INT frxChEsTx | 1.3.6.1.4.1.1570.1.6.5.1.3 | INTEGER | read-only | Current Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxChEsRx | 1.3.6.1.4.1.1570.1.6.5.1.4 | INTEGER | read-only | Current Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPhEsTx | 1.3.6.1.4.1.1570.1.6.5.1.5 | INTEGER | read-only | Previous Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxPhEsRx | 1.3.6.1.4.1.1570.1.6.5.1.6 | INTEGER | read-only | Previous Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH2EsTx | 1.3.6.1.4.1.1570.1.6.5.1.7 | INTEGER | read-only | Errored Seconds 2 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH2EsRx | 1.3.6.1.4.1.1570.1.6.5.1.8 | INTEGER | read-only | Errored Seconds 2 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH3EsTx | 1.3.6.1.4.1.1570.1.6.5.1.9 | INTEGER | read-only | Errored Seconds 3 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH3EsRx | 1.3.6.1.4.1.1570.1.6.5.1.10 | INTEGER | read-only | Errored Seconds 3 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH4EsTx | 1.3.6.1.4.1.1570.1.6.5.1.11 | INTEGER | read-only | Errored Seconds 4 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH4EsRx | 1.3.6.1.4.1.1570.1.6.5.1.12 | INTEGER | read-only | Errored Seconds 4 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH5EsTx | 1.3.6.1.4.1.1570.1.6.5.1.13 | INTEGER | read-only | Errored Seconds 5 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH5EsRx | 1.3.6.1.4.1.1570.1.6.5.1.14 | INTEGER | read-only | Errored Seconds 5 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH6EsTx | 1.3.6.1.4.1.1570.1.6.5.1.15 | INTEGER | read-only | Errored Seconds 6 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH6EsRx | 1.3.6.1.4.1.1570.1.6.5.1.16 | INTEGER | read-only | Errored Seconds 6 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH7EsTx | 1.3.6.1.4.1.1570.1.6.5.1.17 | INTEGER | read-only | Errored Seconds 7 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH7EsRx | 1.3.6.1.4.1.1570.1.6.5.1.18 | INTEGER | read-only | Errored Seconds 7 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxH8EsTx | 1.3.6.1.4.1.1570.1.6.5.1.19 | INTEGER | read-only | Errored Seconds 8 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxH8EsRx | 1.3.6.1.4.1.1570.1.6.5.1.20 | INTEGER | read-only | Errored Seconds 8 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxCdEsTx | 1.3.6.1.4.1.1570.1.6.5.1.21 | INTEGER | read-only | Current Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxCdEsRx | 1.3.6.1.4.1.1570.1.6.5.1.22 | INTEGER | read-only | Current Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPdEsTx | 1.3.6.1.4.1.1570.1.6.5.1.23 | INTEGER | read-only | Previous Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxPdEsRx | 1.3.6.1.4.1.1570.1.6.5.1.24 | INTEGER | read-only | Previous Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxChSesTx | 1.3.6.1.4.1.1570.1.6.5.1.25 | INTEGER | read-only | Current Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxChSesRx | 1.3.6.1.4.1.1570.1.6.5.1.26 | INTEGER | read-only | Current Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPhSesTx | 1.3.6.1.4.1.1570.1.6.5.1.27 | INTEGER | read-only | Previous Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address (note: DDS loops cannot detect transmit errors) |
| INT frxPhSesRx | 1.3.6.1.4.1.1570.1.6.5.1.28 | INTEGER | read-only | Previous Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxCdSesTx | 1.3.6.1.4.1.1570.1.6.5.1.29 | INTEGER | read-only | Current Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxCdSesRx | 1.3.6.1.4.1.1570.1.6.5.1.30 | INTEGER | read-only | Current Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPdSesTx | 1.3.6.1.4.1.1570.1.6.5.1.31 | INTEGER | read-only | Previous Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPdSesRx | 1.3.6.1.4.1.1570.1.6.5.1.32 | INTEGER | read-only | Previous Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) and not at the frame relay level. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxChBeTx | 1.3.6.1.4.1.1570.1.6.5.1.33 | INTEGER | read-only | Current Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxChBeRx | 1.3.6.1.4.1.1570.1.6.5.1.34 | INTEGER | read-only | Current Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPhBeTx | 1.3.6.1.4.1.1570.1.6.5.1.35 | INTEGER | read-only | Previous Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
| INT frxPhBeRx | 1.3.6.1.4.1.1570.1.6.5.1.36 | INTEGER | read-only | Previous Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame relay level errors. This register is defined by Bellcore TR-TSY-000829. Indexed by Bank.ChannelUnit.Port.Address |
RFC description
Cisco 90 Series Frame Relay Multiplexer management for system clock, channel units, ports, and performance monitoring.
Start monitoring Cisco 90 series router/access server (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.