ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB

Organization: ADTRAN Inc.

Last Updated: 2014-09-10

Category: Vendor: ADTRAN

Description: Provides per-CoS per-EVC MEF performance history intervals on ADTRAN devices for carrier Ethernet service monitoring.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB?

This MIB module, defined by ADTRAN for AOS products, implements MEF (Metro Ethernet Forum) performance-history statistics broken down per Class of Service (CoS) per Ethernet Virtual Connection (EVC). It exposes high-capacity performance counters over rolling 15-minute intervals, including ingress/egress green (conforming) frame and octet counts, discarded frames, and interval validity flags. This is a performance/traffic-monitoring MIB rather than a hardware health MIB: it lets carrier Ethernet operators track per-service, per-CoS throughput and frame loss trends over time to detect SLA violations or congestion on a specific EVC. It follows MEF performance-monitoring conventions and depends on the associated MEF EVC/UNI configuration MIBs to identify the EVC and CoS queue being measured. It is typically deployed on ADTRAN carrier Ethernet access devices delivering Metro Ethernet services where per-service SLA reporting is required. Engineers can download the ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • ADTRAN AOS carrier Ethernet access device delivering MEF EVC services

Monitoring Examples

An operator would poll adMefPerCosPerEvcPhCurIngressGreenFrames15Min and adMefPerCosPerEvcPhCurEgressGreenFrames15Min for a given adMefPerCosPerEvcPhCurEvcNameFixedLen and adMefPerCosPerEvcPhCurQueueNumber to compare ingress vs. egress frame counts for a specific EVC/CoS pair. A rising adMefPerCosPerEvcPhCurIngressGreenFrameDiscards15Min count alongside a low adMefPerCosPerEvcPhCurValidIntervals15Min value would indicate the EVC is experiencing frame loss and unreliable measurement intervals, suggesting congestion or a service-level problem.

What Can Be Monitored

  • per-CoS per-EVC ingress/egress green frame counts
  • per-CoS per-EVC ingress/egress green octet counts
  • ingress green frame discards
  • 15-minute interval elapsed time and validity
Imported Objects

From ADTRAN-AOS

adGenAOSConformanceOBJECT-IDENTITY
adGenAOSMefOBJECT-IDENTITY

From ADTRAN-MIB

adIdentityOBJECT-IDENTITY

From HC-PerfHist-TC-MIB

HCPerfCurrentCount
HCPerfIntervalCount
HCPerfInvalidIntervals
HCPerfTimeElapsed
HCPerfTotalCount
HCPerfValidIntervals

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DisplayString
OIDs

RFC description

Adtran vendor-private MIB; manages Metro Ethernet Forum (MEF) performance history metrics per Class of Service per Ethernet Virtual Circuit on Adtran equipment.

Start monitoring ADTRAN NetVanta/SDG-series AOS devices with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ADTRAN-MEF-PER-COS-PER-EVC-PERF-HISTORY-MIB