USR-TRAP-MIB

MIB Reference — IPNetwork Monitor

All MIBsUSR-TRAP-MIB

Category: CommWorks/3Com Access Equipment

Description:

Defines SNMP trap notifications for fault and event reporting on CommWorks broadband equipment.

Imported Objects

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

enterprises

From RFC1213-MIB

DisplayString

What Is USR-TRAP-MIB?

USR-TRAP-MIB is a vendor-specific SNMP module originally from U.S. Robotics/CommWorks defining trap notifications for fault and event reporting on CommWorks broadband access equipment (e.g. modem/remote-access concentrators). Its only confirmed content in the available source is the "usr" enterprise OID branch under which the vendor's trap and object definitions are rooted; the specific fault/event traps themselves are defined using this branch as their base. As a trap-oriented module it is used for fault monitoring - alerting on abnormal conditions or events on the equipment - rather than exposing polled hardware performance counters like temperature or CPU load directly, though the underlying traps would typically flag conditions such as line faults, port failures, or configuration issues. No other MIB dependency is evident beyond the standard SNMP notification framework and the vendor's own OID registration. Typical deployment context is legacy USR/CommWorks broadband remote-access or modem-bank equipment in telecom/ISP environments. Engineers can download the USR-TRAP-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in USR-TRAP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • fault/event trap notifications (specific trap types not detailed in available source)

Supported Devices

  • U.S. Robotics/CommWorks broadband access equipment (modem/remote-access concentrator)

Monitoring Examples

With only the "usr" root OID confirmed in the available sample objects, this module's specific trap objects (fault codes, event descriptions) are not directly enumerated in the source material; a network management station would subscribe to traps rooted under the "usr" enterprise branch to receive fault notifications from CommWorks equipment. Without further object detail, a more specific polling scenario cannot be responsibly constructed. This entry should be treated as based on limited available data pending fuller module content.

OIDs
OID symbolicOID numericTypeAccessDescription
usr1.3.6.1.4.1.429
NTF moduleInserted1.3.6.1.4.1.429.0.1A card has been inserted into the hub.
NTF moduleRemoved1.3.6.1.4.1.429.0.2A card has been removed from the hub.
NTF psuWarning1.3.6.1.4.1.429.0.3Power supply voltage out of normal operating range.
NTF psuFailure1.3.6.1.4.1.429.0.4Power supply failure.
NTF tempWarning1.3.6.1.4.1.429.0.5Internal hub temperature out of normal operating range.
NTF fanFailure1.3.6.1.4.1.429.0.6Hub cooling fan failed.
NTF entityWatchdogTimeout1.3.6.1.4.1.429.0.7Watchdog timeout detected; indication of software failure.
NTF entityMgtBusFailure1.3.6.1.4.1.429.0.8Management bus failure. Entity fails to respond to Managment Card.
NTF incomingConnectionEstablished1.3.6.1.4.1.429.0.9Incoming connection established on modem.
NTF outgoingConnectionEstablished1.3.6.1.4.1.429.0.10Outgoing connection established on modem.
NTF incomingConnectionTerminated1.3.6.1.4.1.429.0.11Incoming connection terminated on modem.
NTF outgoingConnectionTerminated1.3.6.1.4.1.429.0.12Outgoing connection terminated on modem.
NTF connectAttemptFailure1.3.6.1.4.1.429.0.13Modem failed an attempt to connect with another modem.
NTF connectTimerExpired1.3.6.1.4.1.429.0.14Modem's connection time limit expired. The connection was terminated.
NTF dteTransmitDataIdle1.3.6.1.4.1.429.0.15The DTE connected to this modem has not transmitted anything to this modem for a period longer than its idle time threshold.
NTF dtrTrue1.3.6.1.4.1.429.0.16The attached DTE is asserting the DTR signal in a 'true' condition.
NTF dtrFalse1.3.6.1.4.1.429.0.17The DTE attached to this modem is asserting DTR in a 'false' condition.
NTF blerCountAtThreshold1.3.6.1.4.1.429.0.18This modem's block error counter has exceeded the defined 'good' threshold during the current call.
NTF fallbackCountAtThreshold1.3.6.1.4.1.429.0.19This modem's fallback counter has exceeded the normal 'good' threshold during the current call.
NTF noDialtone1.3.6.1.4.1.429.0.20The modem has detected a lack of dial tone when it went off hook to dial.
NTF noLoopCurrent1.3.6.1.4.1.429.0.21The modem has detected a lack of loop current on the phone line when it went off hook to dial.
NTF yellowAlarm1.3.6.1.4.1.429.0.22A yellow alarm condition exists when the remote end of a DS1 is experiencing an 'out-of-frame' or 'OOF' condition.
NTF redAlarm1.3.6.1.4.1.429.0.23The framing pattern has been lost on the DS1's receiver. This is also known as an 'out-of-frame' or 'OOF' condition.
NTF lossOfSignal1.3.6.1.4.1.429.0.24The DS1 receiver has received 175 consecutive 0's. The DS1 is unable to recover a receive signal.
NTF alarmIndicationSignal1.3.6.1.4.1.429.0.25The DS1 is receiving an all ones pattern. This is an indication that the remote end has lost its receive signal. This condition is also known as blue alarm.
NTF transmitTimingSourceSwitch1.3.6.1.4.1.429.0.26The specified Dual T1 card has switched to an alternate timing source.
NTF modemResetByDte1.3.6.1.4.1.429.0.27This specific trap is generated when modem is reset by dte.
NTF modemRingNoAnswer1.3.6.1.4.1.429.0.28If the DTR is present and s0 register on the NAC is not equal to zero, then the Modem Ring No Answer event is generated.
NTF dteRingNoAnswer1.3.6.1.4.1.429.0.29The DTE Ring No Answer event is generated when the DTR is not present and the s0 register on the NAC is not equal to zero.
NTF pktBusSessActive1.3.6.1.4.1.429.0.30Packet bus session active trap.
NTF pktBusSessCongestion1.3.6.1.4.1.429.0.31Packet bus session congestion trap.
NTF pktBusSessLost1.3.6.1.4.1.429.0.32Packet bus session lost trap.
NTF pktBusSessInactive1.3.6.1.4.1.429.0.33Packet bus session inactive trap.
NTF nacUserInterfaceReset1.3.6.1.4.1.429.0.34The NAC has been RESET from the User Interface.
NTF gwWanPortOutOfService1.3.6.1.4.1.429.0.35A gateway WAN port has changed from Link Active to Out of Service.
NTF gwWanPortLinkActive1.3.6.1.4.1.429.0.36A gateway WAN port has changed from Out of Service to Link Active.
NTF dialOutLoginFail1.3.6.1.4.1.429.0.37A dial out login security session has failed.
NTF dialInLoginFail1.3.6.1.4.1.429.0.38A dial in login security session has failed.
NTF dialOutRestrictedNum1.3.6.1.4.1.429.0.39A dial out security session has failed as a result of attempting to dial a restricted phone number.
NTF dialBackRestrictedNum1.3.6.1.4.1.429.0.40A dial back security session has failed as a result of attempting to dial a restricted phone number.
NTF userBlacklisted1.3.6.1.4.1.429.0.41A security user has reached their final failed login attempt number and is now being blacklisted.
NTF loginAttemptByBlacklistedUser1.3.6.1.4.1.429.0.42A security login attempt by a currently blacklisted user has occurred.
NTF responseAttemptLimExceeded1.3.6.1.4.1.429.0.43A security user has failed to issue a valid response to a particular security prompt before the configured limit.
NTF mdmLoginAttemptLimExceeded1.3.6.1.4.1.429.0.44This signals a security session failure when the indicated user does not appear in the security user database.
NTF dialOutCallDuration1.3.6.1.4.1.429.0.45A dial out call has ended.
NTF dialInCallDuration1.3.6.1.4.1.429.0.46A dial in call has ended.
NTF pktBusSessError1.3.6.1.4.1.429.0.47Packet bus session error trap.
NTF nmcArCustomTrap1.3.6.1.4.1.429.0.48NMC AutoResponse SNMP TRAP
NTF acctSrvrLoss1.3.6.1.4.1.429.0.49Contact lost with RADIUS accounting server.
NTF yellowAlarmClear1.3.6.1.4.1.429.0.50A yellow alarm condition has been cleared.
NTF redAlarmClear1.3.6.1.4.1.429.0.51The red alarm condition has been cleared.
NTF lossOfSignalClear1.3.6.1.4.1.429.0.52The loss of signal condition has been cleared.
NTF alarmIndicationSignalClear1.3.6.1.4.1.429.0.53The blue alarm condition has been cleared.
NTF ctIncomingConnectionEstablished1.3.6.1.4.1.429.0.54Incoming connection established on modem.
NTF ctOutgoingConnectionEstablished1.3.6.1.4.1.429.0.55Outgoing connection established on modem.
NTF ctIncomingConnectionTerminated1.3.6.1.4.1.429.0.56Incoming connection terminated on modem.
NTF ctOutgoingConnectionTerminated1.3.6.1.4.1.429.0.57Outgoing connection terminated on modem.
NTF ctConnectAttemptFailure1.3.6.1.4.1.429.0.58Modem failed an attempt to connect with another modem.
NTF contCrcAlarm1.3.6.1.4.1.429.0.59A continuous CRC error condition has occurred on the DS1.
NTF contCrcAlarmClear1.3.6.1.4.1.429.0.60A continuous CRC error condition has cleared on the DS1.
NTF phyStateChng1.3.6.1.4.1.429.0.61A physical state change has occurred on the DS1.

RFC description

Defines SNMP trap types and event notifications for USR network management devices.

Start monitoring U.S. Robotics/CommWorks broadband access equipment, modem/remote-access concentrator (fault/event trap notification status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download USR-TRAP-MIB