TELDAT-CFG-INTERF-IEC101GW-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TELDAT-CFG-INTERF-IEC101GW-MIB

Category: IP Services and Protocols, SCADA and Industrial Protocols

Description: Manages Teldat router IEC 101 SCADA gateway interface configuration and serial link settings.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is TELDAT-CFG-INTERF-IEC101GW-MIB?

TELDAT-CFG-INTERF-IEC101GW-MIB is a vendor MIB from Teldat, a Spanish manufacturer of enterprise/industrial routers, covering configuration of the IEC 60870-5-101 protocol gateway interface on its router platforms. It exposes configuration objects for the serial link parameters and protocol settings that let a Teldat router act as a gateway translating IEC 101 SCADA traffic for utility/industrial control networks. Its monitoring relevance is primarily configuration and interface-state oriented: confirming the serial link parameters and gateway operating mode are correctly set, since a misconfigured baud rate, address, or protocol parameter would break SCADA polling between a remote terminal unit and its control center. As a gateway-protocol MIB it depends conceptually on the IEC 60870-5-101/104 standards it bridges between, though it doesn't appear to import other SNMP MIBs directly. It is deployed on Teldat routers used as protocol gateways in electrical utility, water, or other SCADA/industrial-control WAN deployments, where TELDAT-CFG-INTERF-IEC101GW-MIB SNMP monitoring verifies the gateway's serial-link configuration stays correct.

IPNetwork Monitor allows you to monitor SNMP objects defined in TELDAT-CFG-INTERF-IEC101GW-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Teldat routers configured as IEC 60870-5-101 SCADA protocol gateways

Monitoring Examples

No concrete object or table names were captured from this MIB's parsed source. In practice an operator would poll the gateway's serial-interface configuration objects (e.g., baud rate, station address, protocol mode) to confirm the IEC 101 link is configured as expected, with a mismatch or link-down condition explaining a SCADA master losing contact with a remote substation.

What Can Be Monitored

  • IEC 101 serial link configuration
  • gateway protocol mode/settings
  • interface operational parameters
Imported Objects

From RFC-1212

OBJECT-TYPE

From TELDAT-SW-STRUCTURE-MIB

telProdNpConfInterfaceOBJECT-IDENTITY
OIDs

RFC description

Manages configuration of IEC-101 gateway interfaces on Teldat networking devices, including serial communication parameters and protocol settings.

Start monitoring Teldat router configured as IEC 60870-5-101 SCADA protocol gateway (serial-link config status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download TELDAT-CFG-INTERF-IEC101GW-MIB