TELDAT-CFG-INTERF-IEC101GW-MIB :: telProdNpIec101GWIfcTestType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TELDAT-CFG-INTERF-IEC101GW-MIB › telProdNpIec101GWIfcTestType

telProdNpIec101GWIfcTestType

Module: TELDAT-CFG-INTERF-IEC101GW-MIB

OID (symbolic): TELDAT-CFG-INTERF-IEC101GW-MIB::telProdNpIec101GWIfcTestType

OID (numeric): 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Configure type of IEC-101 Link Test message to send to RTU. 0 Don't send message, 1 Send Test message, 2 Send Status message.

What is telProdNpIec101GWIfcTestType?

This object selects which type of IEC-101 link test message this interface sends to the RTU: none, a test message, or a status message. Admins choose the message type based on what the connected RTU supports or what best confirms link health for their deployment. For example, setting this to status(2) makes the interface send status-request link test messages instead of plain test frames.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15
snmpwalk -v2c -c public <target> TELDAT-CFG-INTERF-IEC101GW-MIB::telProdNpIec101GWIfcTestType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15.1
snmpget -v2c -c public <target> TELDAT-CFG-INTERF-IEC101GW-MIB::telProdNpIec101GWIfcTestType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> telProdNpIec101GWIfcTestType.1

Start monitoring Teldat router configured as IEC 60870-5-101 SCADA protocol gateway (serial-link config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TELDAT-CFG-INTERF-IEC101GW-MIB::telProdNpIec101GWIfcTestType OID value, configure state conditions and alerts, and monitor any Teldat router configured as IEC 60870-5-101 SCADA protocol gateway (serial-link config status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2007teldatTELDAT-MIB
1.3.6.1.4.1.2007.4telproductsTELDAT-MIB
1.3.6.1.4.1.2007.4.1telProductsNucleoxTELDAT-SW-STRUCTURE-MIB
1.3.6.1.4.1.2007.4.1.1telProductsNpConfigTELDAT-SW-STRUCTURE-MIB
1.3.6.1.4.1.2007.4.1.1.4telProdNpConfInterfaceTELDAT-SW-STRUCTURE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2007.4.1.1.4.16telProdNpConfInterfIec101GWTELDAT-CFG-INTERF-IEC101GW-MIB
1.3.6.1.4.1.2007.4.1.1.4.16.1telProdNpIec101GWTableTELDAT-CFG-INTERF-IEC101GW-MIB
1.3.6.1.4.1.2007.4.1.1.4.16.1.1telProdNpIec101GWEntryTELDAT-CFG-INTERF-IEC101GW-MIB
1.3.6.1.4.1.2007.4.1.1.4.16.1.1.15telProdNpIec101GWIfcTestTypeTELDAT-CFG-INTERF-IEC101GW-MIB