All MIBs › SOCOMECUPS-MIB
Category: Environmental Monitoring and Power, Socomec Power Management
Description: Manages Socomec UPS power configuration, battery status, input/output measurements, and alarm conditions.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SOCOMECUPS-MIB?
SOCOMECUPS-MIB is a vendor-specific MIB from Socomec, a manufacturer of uninterruptible power supply (UPS) systems used to protect critical electrical loads. It exposes data on UPS identity and firmware, battery state, input/output power measurements, and alarm/fault conditions. It is heavily used for hardware health monitoring: battery status, seconds/time remaining on battery, estimated charge remaining, battery voltage and temperature, and input line frequency all let an operator detect an aging battery, an impending outage, or overheating before the UPS fails. It loosely follows the object-naming conventions of the standard UPS-MIB (RFC 1628) for battery and input groups, though it is Socomec's own private enterprise MIB. It is typically deployed in data centers and server rooms where Socomec UPS units protect racks of IT equipment, polled by facilities or NOC monitoring systems. Engineers can download the SOCOMECUPS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in SOCOMECUPS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Socomec UPS
- power protection equipment
Monitoring Examples
An administrator would poll upsBatteryStatus and upsEstimatedMinutesRemaining together with upsEstimatedChargeRemaining to catch a battery nearing depletion during a mains outage, and would watch upsSecondsOnBattery to see how long the unit has already been running unpowered. upsBatteryTemperature and upsBatteryVoltage reveal thermal stress or cell degradation, while upsInputFrequency and upsInputNumLines confirm the incoming utility feed is stable. A sudden jump in upsSecondsOnBattery combined with falling upsEstimatedChargeRemaining is a classic signal of an unexpected power event in progress.
What Can Be Monitored
- battery status
- estimated runtime remaining
- battery charge percentage
- battery voltage and temperature
- input line frequency
- firmware and serial number identity
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
From SNMPv2-TC
| AutonomousType | |
| DisplayString | |
| TestAndIncr | |
| TimeInterval | |
| TimeStamp |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| socomecSicon | 1.3.6.1.4.1.4555 | |||
| software | 1.3.6.1.4.1.4555.1 | |||
| network | 1.3.6.1.4.1.4555.1.1 | |||
| netvision | 1.3.6.1.4.1.4555.1.1.1 | |||
| upsObjects | 1.3.6.1.4.1.4555.1.1.1.1 | |||
| upsIdent | 1.3.6.1.4.1.4555.1.1.1.1.1 | |||
| STR upsIdentModel | 1.3.6.1.4.1.4555.1.1.1.1.1.1 | DisplayString | read-only | The UPS Model designation. |
| STR upsIdentUPSFirmwareVersion | 1.3.6.1.4.1.4555.1.1.1.1.1.2 | DisplayString | read-only | The UPS firmware version. |
| STR upsIdentAgentSoftwareVersion | 1.3.6.1.4.1.4555.1.1.1.1.1.3 | DisplayString | read-only | The UPS Net Vision software version. |
| STR upsIdentUpsSerialNumber | 1.3.6.1.4.1.4555.1.1.1.1.1.4 | DisplayString | read-only | The UPS serial no. |
| upsBattery | 1.3.6.1.4.1.4555.1.1.1.1.2 | |||
| INT upsBatteryStatus | 1.3.6.1.4.1.4555.1.1.1.1.2.1 | INTEGER | read-only | The present battery status |
| INT upsSecondsOnBattery | 1.3.6.1.4.1.4555.1.1.1.1.2.2 | INTEGER | read-only | If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. -1 shall be returned if the unit is not on battery power. |
| INT upsEstimatedMinutesRemaining | 1.3.6.1.4.1.4555.1.1.1.1.2.3 | INTEGER | read-only | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. |
| INT upsEstimatedChargeRemaining | 1.3.6.1.4.1.4555.1.1.1.1.2.4 | INTEGER | read-only | An estimate of the battery charge remaining expressed as a percent of full charge. |
| INT upsBatteryVoltage | 1.3.6.1.4.1.4555.1.1.1.1.2.5 | INTEGER | read-only | The magnitude of the present battery voltage in 0.1 Volt DC. |
| INT upsBatteryTemperature | 1.3.6.1.4.1.4555.1.1.1.1.2.6 | INTEGER | read-only | The ambient temperature at or near the UPS Battery casing. |
| upsInput | 1.3.6.1.4.1.4555.1.1.1.1.3 | |||
| INT upsInputNumLines | 1.3.6.1.4.1.4555.1.1.1.1.3.1 | INTEGER | read-only | The number of input lines utilized in this device. This variable indicates the number of rows in the input table. |
| INT upsInputFrequency | 1.3.6.1.4.1.4555.1.1.1.1.3.2 | INTEGER | read-only | The current input frequency to the UPS system in 0.1 HZ. |
| upsInputTable | 1.3.6.1.4.1.4555.1.1.1.1.3.3 | not-accessible | A list of input table entries. The number of entries is given by the value of upsInputNumLines. | |
| upsInputEntry | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1 | not-accessible | An entry containing information applicable to a particular input line. | |
| INT upsInputLineIndex | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1.1 | INTEGER | read-only | |
| INT upsInputVoltage | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2 | INTEGER | read-only | The input utility line voltage in 0.1 volts. |
| INT upsInputCurrent | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3 | INTEGER | read-only | The magnitude of the present input current in 0.1 A. |
| INT upsInputVoltageMax | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1.4 | INTEGER | read-only | The maximum utility line voltage in 0.1 VAC for last 1 minute. |
| INT upsInputVoltageMin | 1.3.6.1.4.1.4555.1.1.1.1.3.3.1.5 | INTEGER | read-only | The minimum utility line voltage in 0.1 VAC for last 1 minute. |
| upsOutput | 1.3.6.1.4.1.4555.1.1.1.1.4 | |||
| INT upsOutputSource | 1.3.6.1.4.1.4555.1.1.1.1.4.1 | INTEGER | read-only | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker. |
| INT upsOutputFrequency | 1.3.6.1.4.1.4555.1.1.1.1.4.2 | INTEGER | read-only | The current output frequency of the UPS system in 0.1 of HZ. |
| INT upsOutputNumLines | 1.3.6.1.4.1.4555.1.1.1.1.4.3 | INTEGER | read-only | The number of output lines utilized in this device. This variable indicates the number of rows in the output table. |
| upsOutputTable | 1.3.6.1.4.1.4555.1.1.1.1.4.4 | not-accessible | A list of output table entries. The number of entries is given by the value of upsOutputNumLines. | |
| upsOutputEntry | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1 | not-accessible | An entry containing information applicable to a particular output line. | |
| INT upsOutputLineIndex | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1.1 | INTEGER | read-only | The output line identifier. |
| INT upsOutputVoltage | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2 | INTEGER | read-only | The output voltage of the UPS system in 0.1 volts. |
| INT upsOutputCurrent | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3 | INTEGER | read-only | The output current of the UPS system in 0.1 Amps. |
| INT upsOutputPercentLoad | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4 | INTEGER | read-only | The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA. |
| INT upsOutputKva | 1.3.6.1.4.1.4555.1.1.1.1.4.4.1.5 | INTEGER | read-only | Output KVA. |
| upsBypass | 1.3.6.1.4.1.4555.1.1.1.1.5 | |||
| INT upsBypassFrequency | 1.3.6.1.4.1.4555.1.1.1.1.5.1 | INTEGER | read-only | The present bypass frequency. |
| INT upsBypassNumLines | 1.3.6.1.4.1.4555.1.1.1.1.5.2 | INTEGER | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. |
| upsBypassTable | 1.3.6.1.4.1.4555.1.1.1.1.5.3 | not-accessible | A list of bypass table entries. The number of entries is given by the value of upsBypassNumLines. | |
| upsBypassEntry | 1.3.6.1.4.1.4555.1.1.1.1.5.3.1 | not-accessible | An entry containing information applicable to a particular bypass input. | |
| INT upsBypassLineIndex | 1.3.6.1.4.1.4555.1.1.1.1.5.3.1.1 | INTEGER | read-only | The bypass line identifier. |
| INT upsBypassVoltage | 1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2 | INTEGER | read-only | The present bypass voltage. |
| INT upsBypassCurrent | 1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3 | INTEGER | read-only | The present bypass current. |
| upsAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6 | |||
| INT upsAlarmsPresent | 1.3.6.1.4.1.4555.1.1.1.1.6.1 | INTEGER | read-only | The present number of active alarm conditions. |
| upsAlarmTable | 1.3.6.1.4.1.4555.1.1.1.1.6.2 | not-accessible | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with upsAlarmId equal to 1, and increments the value of upsAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of upsAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because upsAlarmId might have wrapped. Alarms are named by an OBJECT IDENTIFIER, upsAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of upsAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of upsAlarmsPresent. | |
| upsAlarmEntry | 1.3.6.1.4.1.4555.1.1.1.1.6.2.1 | not-accessible | An entry containing information applicable to a particular alarm. | |
| NUM upsAlarmId | 1.3.6.1.4.1.4555.1.1.1.1.6.2.1.1 | PositiveInteger | read-only | A unique identifier for an alarm condition. This value must remain constant. |
| OID upsAlarmDescr | 1.3.6.1.4.1.4555.1.1.1.1.6.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. |
| TIM upsAlarmTime | 1.3.6.1.4.1.4555.1.1.1.1.6.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0. |
| STR upsAlarmExtDes | 1.3.6.1.4.1.4555.1.1.1.1.6.2.1.4 | DisplayString | read-only | Extra description. |
| upsWellKnownAlarms | 1.3.6.1.4.1.4555.1.1.1.1.6.3 | |||
| INT upsAlarmBatteryBad | 1.3.6.1.4.1.4555.1.1.1.1.6.3.1 | INTEGER | read-only | One or more batteries have been determined to require replacement. |
| INT upsAlarmOnBattery | 1.3.6.1.4.1.4555.1.1.1.1.6.3.2 | INTEGER | read-only | The UPS is drawing power from the batteries. |
| INT upsAlarmLowBattery | 1.3.6.1.4.1.4555.1.1.1.1.6.3.3 | INTEGER | read-only | The remaining battery run-time is less than or equal to upsConfigLowBattTime. |
| INT upsAlarmDepletedBattery | 1.3.6.1.4.1.4555.1.1.1.1.6.3.4 | INTEGER | read-only | The UPS will be unable to sustain the present load when and if the utility power is lost. |
| INT upsAlarmTempBad | 1.3.6.1.4.1.4555.1.1.1.1.6.3.5 | INTEGER | read-only | A temperature is out of tolerance. |
| INT upsAlarmInputBad | 1.3.6.1.4.1.4555.1.1.1.1.6.3.6 | INTEGER | read-only | An input condition is out of tolerance. |
| INT upsAlarmOutputBad | 1.3.6.1.4.1.4555.1.1.1.1.6.3.7 | INTEGER | read-only | An output condition (other than OutputOverload) is out of tolerance. |
| INT upsAlarmOutputOverload | 1.3.6.1.4.1.4555.1.1.1.1.6.3.8 | INTEGER | read-only | The output load exceeds the UPS output capacity. |
| INT upsAlarmOnBypass | 1.3.6.1.4.1.4555.1.1.1.1.6.3.9 | INTEGER | read-only | The Bypass is presently engaged on the UPS. |
| INT upsAlarmBypassBad | 1.3.6.1.4.1.4555.1.1.1.1.6.3.10 | INTEGER | read-only | The Bypass is out of tolerance. |
| INT upsAlarmOutputOffAsRequested | 1.3.6.1.4.1.4555.1.1.1.1.6.3.11 | INTEGER | read-only | The UPS has shutdown as requested, i.e., the output is off. |
| INT upsAlarmUpsOffAsRequested | 1.3.6.1.4.1.4555.1.1.1.1.6.3.12 | INTEGER | read-only | The entire UPS has shutdown as commanded. |
| INT upsAlarmChargerFailed | 1.3.6.1.4.1.4555.1.1.1.1.6.3.13 | INTEGER | read-only | An uncorrected problem has been detected within the UPS charger subsystem. |
| INT upsAlarmUpsOutputOff | 1.3.6.1.4.1.4555.1.1.1.1.6.3.14 | INTEGER | read-only | The output of the UPS is in the off state. |
| INT upsAlarmUpsSystemOff | 1.3.6.1.4.1.4555.1.1.1.1.6.3.15 | INTEGER | read-only | The UPS system is in the off state. |
| INT upsAlarmFanFailure | 1.3.6.1.4.1.4555.1.1.1.1.6.3.16 | INTEGER | read-only | The failure of one or more fans in the UPS has been detected. |
| INT upsAlarmFuseFailure | 1.3.6.1.4.1.4555.1.1.1.1.6.3.17 | INTEGER | read-only | The failure of one or more fuses has been detected. |
| INT upsAlarmGeneralFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.18 | INTEGER | read-only | A general fault in the UPS has been detected. |
| INT upsAlarmDiagnosticTestFailed | 1.3.6.1.4.1.4555.1.1.1.1.6.3.19 | INTEGER | read-only | The result of the last diagnostic test indicates a failure. |
| INT upsAlarmCommunicationLost | 1.3.6.1.4.1.4555.1.1.1.1.6.3.20 | INTEGER | read-only | A problem has been encountered in the communications between the agent and the UPS. |
| INT upsAlarmAwaitingPower | 1.3.6.1.4.1.4555.1.1.1.1.6.3.21 | INTEGER | read-only | The UPS output is off and the UPS is awaiting the return of input power. |
| INT upsAlarmShutdownPending | 1.3.6.1.4.1.4555.1.1.1.1.6.3.22 | INTEGER | read-only | A upsShutdownAfterDelay countdown is underway. |
| INT upsAlarmShutdownImminent | 1.3.6.1.4.1.4555.1.1.1.1.6.3.23 | INTEGER | read-only | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. |
| INT upsAlarmTestInProgress | 1.3.6.1.4.1.4555.1.1.1.1.6.3.24 | INTEGER | read-only | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-TYPE macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-TYPE. |
| INT upsAlarmPowerSupplyFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.25 | INTEGER | read-only | Digital power supply fault. |
| INT upsAlarmAuxMainFail | 1.3.6.1.4.1.4555.1.1.1.1.6.3.26 | INTEGER | read-only | Auxiliary mains out of tolerance. |
| INT upsAlarmManualBypassClose | 1.3.6.1.4.1.4555.1.1.1.1.6.3.27 | INTEGER | read-only | Manual By-pass closed |
| INT upsAlarmShortCircuit | 1.3.6.1.4.1.4555.1.1.1.1.6.3.28 | INTEGER | read-only | Short Circuit on UPS output. |
| INT upsAlarmBatteryChargerFailure | 1.3.6.1.4.1.4555.1.1.1.1.6.3.29 | INTEGER | read-only | Battery charger failure. |
| INT upsAlarmInverterOverCurrent | 1.3.6.1.4.1.4555.1.1.1.1.6.3.30 | INTEGER | read-only | Inverter Over-current. |
| INT upsAlarmInverterDistorsion | 1.3.6.1.4.1.4555.1.1.1.1.6.3.31 | INTEGER | read-only | Excessive Inverter Distorsion. |
| INT upsAlarmPrechargeVoltageFail | 1.3.6.1.4.1.4555.1.1.1.1.6.3.32 | INTEGER | read-only | Precharge voltage out of tolerance. |
| INT upsAlarmBoostTooLow | 1.3.6.1.4.1.4555.1.1.1.1.6.3.33 | INTEGER | read-only | Boost output voltage too low. |
| INT upsAlarmBoostTooHigh | 1.3.6.1.4.1.4555.1.1.1.1.6.3.34 | INTEGER | read-only | Boost output voltage too high. |
| INT upsAlarmBatteryTooHigh | 1.3.6.1.4.1.4555.1.1.1.1.6.3.35 | INTEGER | read-only | Battery voltage too high. |
| INT upsAlarmImproperCondition | 1.3.6.1.4.1.4555.1.1.1.1.6.3.36 | INTEGER | read-only | Improper condition of use |
| INT upsAlarmOverloadTimeout | 1.3.6.1.4.1.4555.1.1.1.1.6.3.37 | INTEGER | read-only | Overload timeout blocking Inverter. |
| INT upsAlarmControlSystemFailure | 1.3.6.1.4.1.4555.1.1.1.1.6.3.38 | INTEGER | read-only | Microprocessor control system failure |
| INT upsAlarmDataCorrupted | 1.3.6.1.4.1.4555.1.1.1.1.6.3.39 | INTEGER | read-only | Configuration data map corrupted. |
| INT upsAlarmPllFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.40 | INTEGER | read-only | Pll fault. |
| INT upsAlarmInputGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.41 | INTEGER | read-only | Input mains general alarm. |
| INT upsAlarmRectifierGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.42 | INTEGER | read-only | Rectifier general alarm. |
| INT upsAlarmBoostGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.43 | INTEGER | read-only | Boost general alarm. |
| INT upsAlarmInverterGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.44 | INTEGER | read-only | Inverter general alarm. |
| INT upsAlarmBatteryGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.45 | INTEGER | read-only | Bettery charger general alarm. |
| INT upsAlarmOutputOver | 1.3.6.1.4.1.4555.1.1.1.1.6.3.46 | INTEGER | read-only | Output voltage over limit. |
| INT upsAlarmOutputUnder | 1.3.6.1.4.1.4555.1.1.1.1.6.3.47 | INTEGER | read-only | Output voltage under limit. |
| INT upsAlarmBypassGeneralAlarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.48 | INTEGER | read-only | Bypass charger general alarm. |
| INT upsAlarmStopForOverload | 1.3.6.1.4.1.4555.1.1.1.1.6.3.49 | INTEGER | read-only | Stop for overload. |
| INT upsAlarmImminentStop | 1.3.6.1.4.1.4555.1.1.1.1.6.3.50 | INTEGER | read-only | UPS imminent stop |
| INT upsAlarmModule1Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.51 | INTEGER | read-only | Module 1 in parallel general alarm. |
| INT upsAlarmModule2Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.52 | INTEGER | read-only | Module 2 in parallel general alarm. |
| INT upsAlarmModule3Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.53 | INTEGER | read-only | Module 3 in parallel general alarm. |
| INT upsAlarmModule4Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.54 | INTEGER | read-only | Module 4 in parallel general alarm. |
| INT upsAlarmModule5Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.55 | INTEGER | read-only | Module 5 in parallel general alarm. |
| INT upsAlarmModule6Alarm | 1.3.6.1.4.1.4555.1.1.1.1.6.3.56 | INTEGER | read-only | Module 6 in parallel general alarm. |
| INT upsAlarmExternalAlarm1 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.57 | INTEGER | read-only | External Alarm 1. |
| INT upsAlarmExternalAlarm2 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.58 | INTEGER | read-only | External Alarm 2. |
| INT upsAlarmExternalAlarm3 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.59 | INTEGER | read-only | External Alarm 3. |
| INT upsAlarmExternalAlarm4 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.60 | INTEGER | read-only | External Alarm 4. |
| INT upsAlarmEService | 1.3.6.1.4.1.4555.1.1.1.1.6.3.61 | INTEGER | read-only | E-Service General Alarm |
| INT upsAlarmRedundancyLost | 1.3.6.1.4.1.4555.1.1.1.1.6.3.62 | INTEGER | read-only | Redundancy lost |
| INT upsAlarmPeriodicServiceCheck | 1.3.6.1.4.1.4555.1.1.1.1.6.3.63 | INTEGER | read-only | Periodic service check up. |
| INT upsAlarmAllTransferDisabled | 1.3.6.1.4.1.4555.1.1.1.1.6.3.64 | INTEGER | read-only | Automatic and manual transfer disabled |
| INT upsAlarmAutoTransferDisabled | 1.3.6.1.4.1.4555.1.1.1.1.6.3.65 | INTEGER | read-only | Automatic transfer disabled |
| INT upsAlarmBatteryRoom | 1.3.6.1.4.1.4555.1.1.1.1.6.3.66 | INTEGER | read-only | Battery room alarm |
| INT upsAlarmManualBypass | 1.3.6.1.4.1.4555.1.1.1.1.6.3.67 | INTEGER | read-only | Manual bypass alarm |
| INT upsAlarmBatteryDischarged | 1.3.6.1.4.1.4555.1.1.1.1.6.3.68 | INTEGER | read-only | Battery Discharged |
| INT upsAlarmInsufficientResources | 1.3.6.1.4.1.4555.1.1.1.1.6.3.69 | INTEGER | read-only | Insufficient resources |
| INT upsAlarmOptionalBoards | 1.3.6.1.4.1.4555.1.1.1.1.6.3.70 | INTEGER | read-only | Optional boards general alarm |
| INT upsAlarmRectifierFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.71 | INTEGER | read-only | Rectifier fault |
| INT upsAlarmBoostFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.72 | INTEGER | read-only | Boost fault |
| INT upsAlarmInverterFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.73 | INTEGER | read-only | Inverter fault |
| INT upsAlarmParallelModuleFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.74 | INTEGER | read-only | Parallel module fault |
| INT upsAlarmGenSetGeneral | 1.3.6.1.4.1.4555.1.1.1.1.6.3.75 | INTEGER | read-only | Gen-set general alarm |
| INT upsAlarmGenSetFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.76 | INTEGER | read-only | Gen-set fault |
| INT upsAlarmEmergencyStopActive | 1.3.6.1.4.1.4555.1.1.1.1.6.3.77 | INTEGER | read-only | Emergency stop active |
| INT upsAlarmBatteryCircuitOpen | 1.3.6.1.4.1.4555.1.1.1.1.6.3.78 | INTEGER | read-only | Battery circuit open |
| INT upsAlarmFansFailure | 1.3.6.1.4.1.4555.1.1.1.1.6.3.79 | INTEGER | read-only | Fans failure |
| INT upsAlarmPhaseRotationFault | 1.3.6.1.4.1.4555.1.1.1.1.6.3.80 | INTEGER | read-only | Phase rotation fault |
| INT upsAlarmA62 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.81 | INTEGER | read-only | A62. |
| INT upsAlarmA63 | 1.3.6.1.4.1.4555.1.1.1.1.6.3.82 | INTEGER | read-only | A63. |
| upsTest | 1.3.6.1.4.1.4555.1.1.1.1.7 | |||
| OID upsTestId | 1.3.6.1.4.1.4555.1.1.1.1.7.1 | OBJECT IDENTIFIER | read-write | The test named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of test, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. Setting this variable initiates the named test. Sets to this variable require the presence of upsTestSpinLock in the same SNMP message. The set request will be rejected with an appropriate error message if the requested test cannot be performed, including attempts to start a test when another test is already in progress. Tests in progress may be aborted by setting this variable to upsTestAbortTestInProgress. Read operations return the value of the name of the test in progress if a test is in progress or the name of the last test performed if no test is in progress, unless no test has bee run, in which case the well known value upsTestNoTestsInitiated is returned. |
| TES upsTestSpinLock | 1.3.6.1.4.1.4555.1.1.1.1.7.2 | TestAndIncr | read-write | A spin lock on the test subsystem. The spinlock is used as follows. Before starting a test, a manager-station should make sure that a test is not in progress as follows: try_again: get (upsTestSpinLock) while (upsTestResultsSummary == inProgress) { /* loop while a test is running for another manager */ short delay get (upsTestSpinLock) } lock_value = upsTestSpinLock /* no test in progress, start the test */ set (upsTestSpinLock = lock_value, upsTestId = requested_test) if (error_index == 1) { /* (upsTestSpinLock failed) */ /* if problem is not access control, then some other manager slipped in ahead of us */ goto try_again } if (error_index == 2) { /* (upsTestId) */ /* cannot perform the test */ give up } /* test started ok */ /* wait for test completion by polling upsTestResultsSummary */ get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) while (upsTestResultsSummary == inProgress) { short delay get (upsTestSpinLock, upsTestResultsSummary, upsTestResultsDetail) } /* when test completes, retrieve any additional test results */ /* if upsTestSpinLock == lock_value + 1, then these are our test */ /* results (as opposed to another manager's */ The initial value of upsTestSpinLock at agent initialization shall be 1. |
| INT upsTestResultsSummary | 1.3.6.1.4.1.4555.1.1.1.1.7.3 | INTEGER | read-only | The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results. |
| STR upsTestResultsDetail | 1.3.6.1.4.1.4555.1.1.1.1.7.4 | DisplayString | read-only | Additional information about upsTestResultsSummary. If no additional information available, a zero length string is returned. |
| TIM upsTestStartTime | 1.3.6.1.4.1.4555.1.1.1.1.7.5 | TimeStamp | read-only | The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestStartTime has the value 0. |
| NUM upsTestElapsedTime | 1.3.6.1.4.1.4555.1.1.1.1.7.6 | TimeInterval | read-only | The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 0. |
| upsWellKnownTests | 1.3.6.1.4.1.4555.1.1.1.1.7.7 | |||
| INT upsTestNoTestsInitiated | 1.3.6.1.4.1.4555.1.1.1.1.7.7.1 | INTEGER | read-only | No tests have been initiated and no test is in progress. |
| INT upsTestAbortTestInProgress | 1.3.6.1.4.1.4555.1.1.1.1.7.7.2 | INTEGER | read-only | The test in progress is to be aborted / the test in progress was aborted. |
| INT upsTestGeneralSystemsTest | 1.3.6.1.4.1.4555.1.1.1.1.7.7.3 | INTEGER | read-only | The manufacturer's standard test of UPS device systems. |
| INT upsTestQuickBatteryTest | 1.3.6.1.4.1.4555.1.1.1.1.7.7.4 | INTEGER | read-only | A test that is sufficient to determine if the battery needs replacement. |
| INT upsDeepBatteryCalibration | 1.3.6.1.4.1.4555.1.1.1.1.7.7.5 | INTEGER | read-only | The system is placed on battery to a discharge level, set by the manufacturer, sufficient to determine battery replacement and battery run-time with a high degree of confidence. WARNING: this test will leave the battery in a low charge state and will require time for recharging to a level sufficient to provide normal battery duration for the protected load. |
| upsControl | 1.3.6.1.4.1.4555.1.1.1.1.8 | |||
| INT upsControlStatusControl | 1.3.6.1.4.1.4555.1.1.1.1.8.1 | INTEGER | read-write | This object Control UPS status |
| INT upsShutdownDelay | 1.3.6.1.4.1.4555.1.1.1.1.8.2 | INTEGER | read-write | This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients |
| INT upsTurnOffAfterShutdown | 1.3.6.1.4.1.4555.1.1.1.1.8.3 | INTEGER | read-write | This object enable/disable UPS turn off function after shutdown process complete |
| upsControlShutdownParametersTable | 1.3.6.1.4.1.4555.1.1.1.1.8.4 | not-accessible | Table which describes the parametes for shutdown process when shutdown event occurs | |
| shutdownParametersEntry | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1 | not-accessible | ||
| STR upsControlEventDescr | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.1 | DisplayString | read-only | The shutdown event identification |
| INT upsControlEventStatus | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.2 | INTEGER | read-write | Status of the corresponding shutdown Event. When set to disable(), shutdown process will not start when corresponding event occured. |
| INT upsControlDelay | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3 | INTEGER | read-write | The Delay after the occurance of the curresponding shutdown event that Net Vision should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the configured Shutdowntime when Net Vision will start sending the warning message to the connected clients. The value is in units of minutes. |
| INT upsControlFirstWarning | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.4 | INTEGER | read-write | The delay after the occurance of the curresponding shutdown event that the Net Vision will start sending the warning message to the connected clients. The value is in units of seconds |
| INT upsControlWarningInterval | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.5 | INTEGER | read-write | The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds. |
| INT upsControlSeverity | 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.6 | INTEGER | read-write | Shutdown daemon severity. |
| upsControlWeeklyScheduleTable | 1.3.6.1.4.1.4555.1.1.1.1.8.5 | not-accessible | The table to schedule shutting down the ups by weekly. | |
| upsControlWeeklyScheduleEntry | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1 | not-accessible | The entries for each day. | |
| INT upsControlWeeklyIndex | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1.1 | INTEGER | read-only | The index of scheduled events. |
| INT upsControlWeeklyShutdownDay | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1.2 | INTEGER | read-write | The weekday on which the UPS should shut down. |
| STR upsControlWeeklyShutdownTime | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1.3 | DisplayString | read-write | The time that the process of shutting down the UPS will be initiated in hh:mm:ss format. |
| INT upsControlWeeklyRestartDay | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1.4 | INTEGER | read-write | The weekday on which the UPS should restart |
| STR upsControlWeeklyRestartTime | 1.3.6.1.4.1.4555.1.1.1.1.8.5.1.5 | DisplayString | read-write | The time the UPS will restart in hh:mm:ss format. |
| upsControlSpecialScheduleTable | 1.3.6.1.4.1.4555.1.1.1.1.8.6 | not-accessible | The table to schedule shutting down the ups. | |
| upsControlSpecialScheduleEntry | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1 | not-accessible | The entries for each day. | |
| INT upsControlSpecialIndex | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1.1 | INTEGER | read-only | The index of scheduled events. |
| STR upsControlSpecialShutdownDay | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1.2 | DisplayString | read-write | The date on which the UPS should shut down in dd/mm/yyyy format. |
| STR upsControlSpecialShutdownTime | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1.3 | DisplayString | read-write | The time that the process of shutting down the UPS will be initiated in hh:mm:ss format |
| STR upsControlSpecialRestartDay | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1.4 | DisplayString | read-write | The date on which the UPS should restart in dd/mm/yyyy format |
| STR upsControlSpecialRestartTime | 1.3.6.1.4.1.4555.1.1.1.1.8.6.1.5 | DisplayString | read-write | The time the UPS will restart in hh:mm:ss format. |
| upsControlEcoModeScheduleTable | 1.3.6.1.4.1.4555.1.1.1.1.8.7 | not-accessible | The table to schedule enable/disable ups eco/mode by weekly. | |
| upsControlEcoModeScheduleEntry | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1 | not-accessible | The entries for each day. | |
| INT upsControlEcoModeIndex | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1.1 | INTEGER | read-only | The index of scheduled events. |
| INT upsControlEcoModeStartDay | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1.2 | INTEGER | read-write | The weekday on which the UPS Eco/Mode should enable. |
| STR upsControlEcoModeStartTime | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1.3 | DisplayString | read-write | The time that the UPS Eco/Mode will be enabled, in hh:mm:ss format. |
| INT upsControlEcoModeEndDay | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1.4 | INTEGER | read-write | The weekday on which the UPS Eco/Mode should disable |
| STR upsControlEcoModeEndTime | 1.3.6.1.4.1.4555.1.1.1.1.8.7.1.5 | DisplayString | read-write | The time the UPS Eco/Mode will disabled, in hh:mm:ss format. |
| upsConfig | 1.3.6.1.4.1.4555.1.1.1.1.9 | |||
| INT upsConfigInputVoltage | 1.3.6.1.4.1.4555.1.1.1.1.9.1 | INTEGER | read-only | The magnitude of the nominal input voltage. |
| INT upsConfigInputFreq | 1.3.6.1.4.1.4555.1.1.1.1.9.2 | INTEGER | read-only | The nominal input frequency. |
| INT upsConfigOutputVoltage | 1.3.6.1.4.1.4555.1.1.1.1.9.3 | INTEGER | read-only | The magnitude of the nominal output voltage. |
| INT upsConfigOutputFreq | 1.3.6.1.4.1.4555.1.1.1.1.9.4 | INTEGER | read-only | The nominal output frequency. |
| upsDevicesTable | 1.3.6.1.4.1.4555.1.1.1.1.9.5 | not-accessible | The devices powered by UPS and registered to Net Vision | |
| upsDevicesEntry | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1 | not-accessible | The devices protected by Net Vision | |
| INT indexOfDevice | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.1 | INTEGER | read-only | The index of the device that is plugged into the UPS. |
| IP addrOfDevice | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.2 | IpAddress | read-only | The ip address of the device. |
| STR nameOfDevice | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.3 | DisplayString | read-only | The name/description of the device plugged into the UPS. |
| STR timeOfConnection | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.4 | DisplayString | read-only | The that device registered to Net Vision |
| INT statusOfConnection | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.5 | INTEGER | read-only | status |
| INT severityOfConnection | 1.3.6.1.4.1.4555.1.1.1.1.9.5.1.6 | INTEGER | read-only | severity |
| upsAgent | 1.3.6.1.4.1.4555.1.1.1.1.10 | |||
| IP upsAgentIpaddress | 1.3.6.1.4.1.4555.1.1.1.1.10.1 | IpAddress | read-write | The ip address that NMS can identify the managed device |
| IP upsAgentGateway | 1.3.6.1.4.1.4555.1.1.1.1.10.2 | IpAddress | read-write | The default gateway that allow device managed through routers |
| IP upsAgentSubnetMask | 1.3.6.1.4.1.4555.1.1.1.1.10.3 | IpAddress | read-write | Internet address subnet mask |
| STR upsAgentDate | 1.3.6.1.4.1.4555.1.1.1.1.10.4 | DisplayString | read-write | The date in agent, format is (dd/mm/yyyy) |
| STR upsAgentTime | 1.3.6.1.4.1.4555.1.1.1.1.10.5 | DisplayString | read-write | The time in agent, format is (hh:mm:ss) |
| STR upsAgentNtpTimeServer | 1.3.6.1.4.1.4555.1.1.1.1.10.6 | DisplayString | read-write | |
| INT upsAgentNtpTimeZone | 1.3.6.1.4.1.4555.1.1.1.1.10.7 | INTEGER | read-write | |
| INT upsAgentHistoryLogFrequency | 1.3.6.1.4.1.4555.1.1.1.1.10.8 | INTEGER | read-write | The frequency of the updation of the history log. The value is in seconds |
| INT upsAgentExtHistoryLogFrequency | 1.3.6.1.4.1.4555.1.1.1.1.10.9 | INTEGER | read-write | The ups parameters are sampled at the rate governed by the mconfigHistroyLogFrequency. These sampled values are further conslidated over period of time which is determined by this object. |
| INT upsAgentPollRate | 1.3.6.1.4.1.4555.1.1.1.1.10.10 | INTEGER | read-write | The frequency that proxy agent polls the connected UPS in JBUS protocol. (unit : second) |
| INT upsAgentBaudRate | 1.3.6.1.4.1.4555.1.1.1.1.10.11 | INTEGER | read-write | The serial port communication speed (2400/9600 allowed). |
| INT upsAgentDhcpStatus | 1.3.6.1.4.1.4555.1.1.1.1.10.12 | INTEGER | read-write | Enable or disable DHCP-BootP capability |
| INT upsAgentTelnetStatus | 1.3.6.1.4.1.4555.1.1.1.1.10.13 | INTEGER | read-write | Enable or disable telnet access |
| INT upsAgentTftpStatus | 1.3.6.1.4.1.4555.1.1.1.1.10.14 | INTEGER | read-write | Enable or disable network upgrade capability |
| INT upsAgentResetToDefault | 1.3.6.1.4.1.4555.1.1.1.1.10.15 | INTEGER | read-write | Reset all parameters of Net Vision to default value |
| INT upsAgentRestart | 1.3.6.1.4.1.4555.1.1.1.1.10.16 | INTEGER | read-write | Restart Net Vision |
| INT upsAgentClearAgentLog | 1.3.6.1.4.1.4555.1.1.1.1.10.17 | INTEGER | read-write | Clear agent log data |
| INT upsAgentClearEventLog | 1.3.6.1.4.1.4555.1.1.1.1.10.18 | INTEGER | read-write | Clear event log data |
| INT upsAgentClearExtHistoryLog | 1.3.6.1.4.1.4555.1.1.1.1.10.19 | INTEGER | read-write | Clear extented history log data |
| INT upsAgentClearHistoryLog | 1.3.6.1.4.1.4555.1.1.1.1.10.20 | INTEGER | read-write | Clear history log data |
| upsAgentTrapsReceiversTable | 1.3.6.1.4.1.4555.1.1.1.1.10.21 | not-accessible | A list of managers to send traps to. The number of entries is given by the value of upsAgentNumTrapReceivers | |
| upsAgentTrapsReceiversEntry | 1.3.6.1.4.1.4555.1.1.1.1.10.21.1 | not-accessible | The managers to send traps to. | |
| INT trapsIndex | 1.3.6.1.4.1.4555.1.1.1.1.10.21.1.1 | INTEGER | read-only | The index to a trap receiver entry. |
| STR trapsReceiverAddr | 1.3.6.1.4.1.4555.1.1.1.1.10.21.1.2 | DisplayString | read-write | The IP address of the manager to send a trap to. |
| STR receiverCommunityString | 1.3.6.1.4.1.4555.1.1.1.1.10.21.1.3 | DisplayString | read-write | The community name to use in the trap when sent to the manager. |
| STR receiverDescription | 1.3.6.1.4.1.4555.1.1.1.1.10.21.1.4 | DisplayString | read-write | Description of trap receivers |
| upsAgentAccessControlTable | 1.3.6.1.4.1.4555.1.1.1.1.10.22 | not-accessible | A list of managers which can access Net Vision with private community string. | |
| upsAgentAccessControlEntry | 1.3.6.1.4.1.4555.1.1.1.1.10.22.1 | not-accessible | The managers. | |
| INT accessIndex | 1.3.6.1.4.1.4555.1.1.1.1.10.22.1.1 | INTEGER | read-only | The index to a access control entry. |
| STR accessControlAddr | 1.3.6.1.4.1.4555.1.1.1.1.10.22.1.2 | DisplayString | read-write | The IP address of the manager to access Net Vision |
| STR accessCommunityString | 1.3.6.1.4.1.4555.1.1.1.1.10.22.1.3 | DisplayString | read-write | The community name to use in the manager when access Net Vision |
| INT accessControlMode | 1.3.6.1.4.1.4555.1.1.1.1.10.22.1.4 | INTEGER | read-write | Access type, only read-Write access type can change parameter of Net Vision |
| INT upsAgentMibVersion | 1.3.6.1.4.1.4555.1.1.1.1.10.23 | INTEGER | read-only | The version of MIB spec. |
| STR upsAgentTrapString | 1.3.6.1.4.1.4555.1.1.1.1.10.50 | DisplayString | read-only | This OID allows traps to be sent with an octet string argument that my not be defined in the. A get of this OID will return error or NULL string. |
| emdStatus | 1.3.6.1.4.1.4555.1.1.1.1.11 | |||
| INT emdSatatusTemperature | 1.3.6.1.4.1.4555.1.1.1.1.11.1 | INTEGER | read-only | The measurement of EMD temperature, in 0.1 degree |
| INT emdSatatusHumidity | 1.3.6.1.4.1.4555.1.1.1.1.11.2 | INTEGER | read-only | The measurement of EMD humidity, in 0.1 degree |
| upsTraps | 1.3.6.1.4.1.4555.1.1.1.2 | |||
| NTF upsTrapOnBattery | 1.3.6.1.4.1.4555.1.1.1.2.0.1 | The UPS is operating on battery power. This trap is persistent and is resent at one minute intervals until the UPS either turns off or is no longer running on battery. | ||
| NTF upsTrapTestCompleted | 1.3.6.1.4.1.4555.1.1.1.2.0.2 | This trap is sent upon completion of a UPS diagnostic test. | ||
| NTF upsTrapAlarmEntryAdded | 1.3.6.1.4.1.4555.1.1.1.2.0.3 | This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress. | ||
| NTF upsTrapAlarmEntryRemoved | 1.3.6.1.4.1.4555.1.1.1.2.0.4 | This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress. | ||
| NTF upsTrapUpsNormal | 1.3.6.1.4.1.4555.1.1.1.2.0.5 | INFORMATION: The UPS status is normal. | ||
| NTF upsTrapUpsBattTestFailed | 1.3.6.1.4.1.4555.1.1.1.2.0.6 | SEVERE: UPS failed the last test of battery. | ||
| NTF upsTrapOnBatteryPower | 1.3.6.1.4.1.4555.1.1.1.2.0.7 | WARNING: The UPS has switched to battery backup power. | ||
| NTF upsTrapBatteryLow | 1.3.6.1.4.1.4555.1.1.1.2.0.8 | SEVERE: Battery is near to be discharged. | ||
| NTF upsTrapPowerRestored | 1.3.6.1.4.1.4555.1.1.1.2.0.9 | INFORMATION: Input power has been restored. | ||
| NTF upsTrapImminentStop | 1.3.6.1.4.1.4555.1.1.1.2.0.10 | SEVERE: The UPS is near to switch off the output power. | ||
| NTF upsTrapTurnedOff | 1.3.6.1.4.1.4555.1.1.1.2.0.11 | WARNING: The UPS has been turned off by the management station. | ||
| NTF upsTrapOverTemperature | 1.3.6.1.4.1.4555.1.1.1.2.0.12 | SEVERE: The UPS has sensed a temperature greater than its limit. | ||
| NTF upsTrapOverload | 1.3.6.1.4.1.4555.1.1.1.2.0.13 | SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity. | ||
| NTF upsTrapOnMains | 1.3.6.1.4.1.4555.1.1.1.2.0.14 | SEVERE: The UPS output is on mains. | ||
| NTF upsTrapRedoundancyLost | 1.3.6.1.4.1.4555.1.1.1.2.0.15 | SEVERE: Redoundancy is lost. | ||
| NTF upsTrapEmdTempLow | 1.3.6.1.4.1.4555.1.1.1.2.0.16 | SEVERE: EMD Sensor detected low temperature. | ||
| NTF upsTrapEmdTempHigh | 1.3.6.1.4.1.4555.1.1.1.2.0.17 | SEVERE: EMD Sensor detected high temperature. | ||
| NTF upsTrapEmdHumidityLow | 1.3.6.1.4.1.4555.1.1.1.2.0.18 | SEVERE: EMD Sensor detected low humidity. | ||
| NTF upsTrapEmdHumidityHigh | 1.3.6.1.4.1.4555.1.1.1.2.0.19 | SEVERE: EMD Sensor detected high humidity. | ||
| NTF upsTrapEmdFirstInputActive | 1.3.6.1.4.1.4555.1.1.1.2.0.20 | SEVERE: The input is active. | ||
| NTF upsTrapEmdFirstInputRestored | 1.3.6.1.4.1.4555.1.1.1.2.0.21 | INFORMATION: The input is restored. | ||
| NTF upsTrapEmdSecondInputActive | 1.3.6.1.4.1.4555.1.1.1.2.0.22 | SEVERE: The input is active. | ||
| NTF upsTrapEmdSecondInputRestored | 1.3.6.1.4.1.4555.1.1.1.2.0.23 | INFORMATION: The input is restored. |
RFC description
Vendor-specific MIB for Socomec UPS (uninterruptible power supply) systems; defines objects for power monitoring and battery status.
Start monitoring Socomec UPS, power protection equipment (battery/input-output/alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.