| OID symbolic | OID numeric | Type | Access | Description |
| lantronix | 1.3.6.1.4.1.244 | | | |
| products | 1.3.6.1.4.1.244.1 | | | |
| slp | 1.3.6.1.4.1.244.1.9 | | | |
| slp1 | 1.3.6.1.4.1.244.1.9.1 | | | This is the MIB module for the SecureLinx Power Manager. |
| slp1SystemGroup | 1.3.6.1.4.1.244.1.9.1.1 | | | |
| STR slp1SystemVersion | 1.3.6.1.4.1.244.1.9.1.1.1 | DisplayString | read-only | The firmware version of the system. |
| STR slp1SystemNICSerialNumber | 1.3.6.1.4.1.244.1.9.1.1.2 | DisplayString | read-only | The serial number of the network interface card in the
system. |
| STR slp1SystemLocation | 1.3.6.1.4.1.244.1.9.1.1.3 | DisplayString | read-write | The location of the system. |
| INT slp1SystemTowerCount | 1.3.6.1.4.1.244.1.9.1.1.4 | INTEGER | read-only | The number of towers in the system. |
| INT slp1SystemEnvMonCount | 1.3.6.1.4.1.244.1.9.1.1.5 | INTEGER | read-only | The number of environmental monitors in the system. |
| slp1SystemTables | 1.3.6.1.4.1.244.1.9.1.2 | | | |
| slp1TowerTable | 1.3.6.1.4.1.244.1.9.1.2.1 | | not-accessible | A table of towers. |
| slp1TowerEntry | 1.3.6.1.4.1.244.1.9.1.2.1.1 | | not-accessible | Row definition for the tower table. |
| INT slp1TowerIndex | 1.3.6.1.4.1.244.1.9.1.2.1.1.1 | INTEGER | not-accessible | Index for the tower table. |
| STR slp1TowerID | 1.3.6.1.4.1.244.1.9.1.2.1.1.2 | DisplayString | read-only | The ID of the tower. |
| STR slp1TowerName | 1.3.6.1.4.1.244.1.9.1.2.1.1.3 | DisplayString | read-write | The name of the tower. |
| INT slp1TowerStatus | 1.3.6.1.4.1.244.1.9.1.2.1.1.4 | INTEGER | read-only | The operational status of the tower. |
| INT slp1TowerInfeedCount | 1.3.6.1.4.1.244.1.9.1.2.1.1.5 | INTEGER | read-only | The number of input feeds on the tower. |
| slp1InfeedTable | 1.3.6.1.4.1.244.1.9.1.2.2 | | not-accessible | A table of input feeds. |
| slp1InfeedEntry | 1.3.6.1.4.1.244.1.9.1.2.2.1 | | not-accessible | Row definition for the input feed table. |
| INT slp1InfeedIndex | 1.3.6.1.4.1.244.1.9.1.2.2.1.1 | INTEGER | not-accessible | Index for the input feed table. |
| STR slp1InfeedID | 1.3.6.1.4.1.244.1.9.1.2.2.1.2 | DisplayString | read-only | The ID of the input feed. |
| STR slp1InfeedName | 1.3.6.1.4.1.244.1.9.1.2.2.1.3 | DisplayString | read-write | The name of the input feed. |
| BIT slp1InfeedCapabilities | 1.3.6.1.4.1.244.1.9.1.2.2.1.4 | Bits | read-only | The capabilities of the input feed. |
| INT slp1InfeedStatus | 1.3.6.1.4.1.244.1.9.1.2.2.1.5 | INTEGER | read-only | The status of the input feed. If the slp1InfeedCapabilities
'onSense' bit is TRUE, then all of the states are supported
and indicate the sensed state of the input feed. If the
slp1InfeedCapabilities 'onSense' bit is FALSE, then only the
'on' and 'noComm' states are supported, and 'on' indicates
a derived state, not a sensed state. |
| INT slp1InfeedLoadStatus | 1.3.6.1.4.1.244.1.9.1.2.2.1.6 | INTEGER | read-only | The status of the load measured on the input feed. If the
slp1InfeedCapabilities 'loadSense' bit is TRUE, then all of
the states are supported. If the slp1InfeedCapabilities
'loadSense' bit is FALSE, then only the 'normal' and 'noComm'
states are supported. |
| INT slp1InfeedLoadValue | 1.3.6.1.4.1.244.1.9.1.2.2.1.7 | INTEGER | read-only | The load measured on the input feed. A non-negative value
indicates the measured load in hundredths of Amps. A
negative value indicates that a load value was not able to
be measured. |
| INT slp1InfeedLoadHighThresh | 1.3.6.1.4.1.244.1.9.1.2.2.1.8 | INTEGER | read-write | The load high threshold value of the input feed in Amps. |
| INT slp1InfeedOutletCount | 1.3.6.1.4.1.244.1.9.1.2.2.1.9 | INTEGER | read-only | The number of outlets on the input feed. |
| slp1OutletTable | 1.3.6.1.4.1.244.1.9.1.2.3 | | not-accessible | A table of outlets. |
| slp1OutletEntry | 1.3.6.1.4.1.244.1.9.1.2.3.1 | | not-accessible | Row definition for the outlet table. |
| INT slp1OutletIndex | 1.3.6.1.4.1.244.1.9.1.2.3.1.1 | INTEGER | not-accessible | Index for the outlet table. |
| STR slp1OutletID | 1.3.6.1.4.1.244.1.9.1.2.3.1.2 | DisplayString | read-only | The ID of the outlet. |
| STR slp1OutletName | 1.3.6.1.4.1.244.1.9.1.2.3.1.3 | DisplayString | read-write | The name of the outlet. |
| BIT slp1OutletCapabilities | 1.3.6.1.4.1.244.1.9.1.2.3.1.4 | Bits | read-only | The capabilities of the outlet. |
| INT slp1OutletStatus | 1.3.6.1.4.1.244.1.9.1.2.3.1.5 | INTEGER | read-only | The status of the outlet. If the slp1OutletCapabilities
'onSense' bit is TRUE, then all of the states are supported
and indicate the sensed state of the outlet. If the
slp1OutletCapabilities 'onSense' bit is FALSE, then only the
'off', 'on', and 'noComm' states are supported, and 'off'
and 'on' indicate a derived state, not a sensed state. |
| INT slp1OutletLoadStatus | 1.3.6.1.4.1.244.1.9.1.2.3.1.6 | INTEGER | read-only | The status of the load measured on the outlet. If the
slp1OutletCapabilities 'loadSense' bit is TRUE, then all of
the states are supported. If the slp1OutletCapabilities
'loadSense' bit is FALSE, then only the 'normal' and 'noComm'
states are supported. |
| INT slp1OutletLoadValue | 1.3.6.1.4.1.244.1.9.1.2.3.1.7 | INTEGER | read-only | The load measured on the outlet. A non-negative value
indicates the measured load in hundredths of Amps. A
negative value indicates that a load value was not able to
be measured. |
| INT slp1OutletLoadLowThresh | 1.3.6.1.4.1.244.1.9.1.2.3.1.8 | INTEGER | read-write | The load low threshold value of the outlet in Amps. |
| INT slp1OutletLoadHighThresh | 1.3.6.1.4.1.244.1.9.1.2.3.1.9 | INTEGER | read-write | The load high threshold value of the outlet in Amps. |
| INT slp1OutletControlState | 1.3.6.1.4.1.244.1.9.1.2.3.1.10 | INTEGER | read-only | The control state of the outlet. The supported states are
dependent upon the slp1OutletCapabilities 'powerControl' and
'shutdown' bits, as well as the supported features of the
firmware version. |
| INT slp1OutletControlAction | 1.3.6.1.4.1.244.1.9.1.2.3.1.11 | INTEGER | read-write | An action to change the control state of the outlet. If the
slp1OutletCapabilities 'powerControl' bit is TRUE, then the
'on', 'off', and 'reboot' actions can be used to change the
control state of the outlet. If the slp1OutletCapabilities
'powerControl' bit is FALSE, then the actions have no effect. |
| slp1EnvMonTable | 1.3.6.1.4.1.244.1.9.1.2.4 | | not-accessible | A table of environmental monitors. |
| slp1EnvMonEntry | 1.3.6.1.4.1.244.1.9.1.2.4.1 | | not-accessible | Row definition for the environmental monitor table. |
| INT slp1EnvMonIndex | 1.3.6.1.4.1.244.1.9.1.2.4.1.1 | INTEGER | not-accessible | Index for the environmental monitor table. |
| STR slp1EnvMonID | 1.3.6.1.4.1.244.1.9.1.2.4.1.2 | DisplayString | read-only | The ID of the environmental monitor. |
| STR slp1EnvMonName | 1.3.6.1.4.1.244.1.9.1.2.4.1.3 | DisplayString | read-write | The name of the environmental monitor. |
| INT slp1EnvMonStatus | 1.3.6.1.4.1.244.1.9.1.2.4.1.4 | INTEGER | read-only | The operational status of the environmental monitor. |
| STR slp1EnvMonWaterSensorName | 1.3.6.1.4.1.244.1.9.1.2.4.1.5 | DisplayString | read-write | The name of the water sensor. |
| INT slp1EnvMonWaterSensorStatus | 1.3.6.1.4.1.244.1.9.1.2.4.1.6 | INTEGER | read-only | The status of the water sensor. |
| STR slp1EnvMonADCName | 1.3.6.1.4.1.244.1.9.1.2.4.1.7 | DisplayString | read-write | The name of the analog-to-digital converter. |
| INT slp1EnvMonADCStatus | 1.3.6.1.4.1.244.1.9.1.2.4.1.8 | INTEGER | read-only | The status of the analog-to-digital converter. |
| INT slp1EnvMonADCCount | 1.3.6.1.4.1.244.1.9.1.2.4.1.9 | INTEGER | read-only | The 8-bit count value from the analog-to-digital converter.
A non-negative value indicates the digital value retrieved
from the ADC. A negative value indicates that a digital
value was not able to be retrieved. |
| INT slp1EnvMonADCLowThresh | 1.3.6.1.4.1.244.1.9.1.2.4.1.10 | INTEGER | read-write | The 8-bit count low threshold value of the analog-to-digital
converter. |
| INT slp1EnvMonADCHighThresh | 1.3.6.1.4.1.244.1.9.1.2.4.1.11 | INTEGER | read-write | The 8-bit count high threshold value of the analog-to-digital
converter. |
| INT slp1EnvMonTempHumidSensorCount | 1.3.6.1.4.1.244.1.9.1.2.4.1.12 | INTEGER | read-only | The number of temperature/humidity sensors on the
environmental monitor. |
| INT slp1EnvMonContactClosureCount | 1.3.6.1.4.1.244.1.9.1.2.4.1.13 | INTEGER | read-only | The number of contact closures on the environmental monitor. |
| slp1TempHumidSensorTable | 1.3.6.1.4.1.244.1.9.1.2.5 | | not-accessible | A table of temperature/humidity sensors. |
| slp1TempHumidSensorEntry | 1.3.6.1.4.1.244.1.9.1.2.5.1 | | not-accessible | Row definition for the temperature/humidity sensor table. |
| INT slp1TempHumidSensorIndex | 1.3.6.1.4.1.244.1.9.1.2.5.1.1 | INTEGER | not-accessible | Index for the temperature/humidity sensor table. |
| STR slp1TempHumidSensorID | 1.3.6.1.4.1.244.1.9.1.2.5.1.2 | DisplayString | read-only | The ID of the temperature/humidity sensor. |
| STR slp1TempHumidSensorName | 1.3.6.1.4.1.244.1.9.1.2.5.1.3 | DisplayString | read-write | The name of the temperature/humidity sensor. |
| INT slp1TempHumidSensorStatus | 1.3.6.1.4.1.244.1.9.1.2.5.1.4 | INTEGER | read-only | The operational status of the temperature/humidity sensor. |
| INT slp1TempHumidSensorTempStatus | 1.3.6.1.4.1.244.1.9.1.2.5.1.5 | INTEGER | read-only | The status of the temperature sensor. |
| INT slp1TempHumidSensorTempValue | 1.3.6.1.4.1.244.1.9.1.2.5.1.6 | INTEGER | read-only | The temperature measured by the sensor. A non-negative value
indicates the measured temperature in tenths of degrees
Celsius. A negative value indicates that a temperature value
was not able to be measured. |
| INT slp1TempHumidSensorTempLowThresh | 1.3.6.1.4.1.244.1.9.1.2.5.1.7 | INTEGER | read-write | The temperature low threshold value of the sensor in degrees
Celsius. |
| INT slp1TempHumidSensorTempHighThresh | 1.3.6.1.4.1.244.1.9.1.2.5.1.8 | INTEGER | read-write | The temperature high threshold value of the sensor in degrees
Celsius. |
| INT slp1TempHumidSensorHumidStatus | 1.3.6.1.4.1.244.1.9.1.2.5.1.9 | INTEGER | read-only | The status of the humidity sensor. |
| INT slp1TempHumidSensorHumidValue | 1.3.6.1.4.1.244.1.9.1.2.5.1.10 | INTEGER | read-only | The humidity measured by the sensor. A non-negative value
indicates the measured humidity in percentage relative
humidity. A negative value indicates that a humidity value
was not able to be measured. |
| INT slp1TempHumidSensorHumidLowThresh | 1.3.6.1.4.1.244.1.9.1.2.5.1.11 | INTEGER | read-write | The humidity low threshold value of the sensor in percentage
relative humidity. |
| INT slp1TempHumidSensorHumidHighThresh | 1.3.6.1.4.1.244.1.9.1.2.5.1.12 | INTEGER | read-write | The humidity low threshold value of the sensor in percentage
relative humidity. |
| slp1ContactClosureTable | 1.3.6.1.4.1.244.1.9.1.2.6 | | not-accessible | A table of contact closures. |
| slp1ContactClosureEntry | 1.3.6.1.4.1.244.1.9.1.2.6.1 | | not-accessible | Row definition for the contact closure table. |
| INT slp1ContactClosureIndex | 1.3.6.1.4.1.244.1.9.1.2.6.1.1 | INTEGER | not-accessible | Index for the contact closure table. |
| STR slp1ContactClosureID | 1.3.6.1.4.1.244.1.9.1.2.6.1.2 | DisplayString | read-only | The ID of the contact closure. |
| STR slp1ContactClosureName | 1.3.6.1.4.1.244.1.9.1.2.6.1.3 | DisplayString | read-write | The name of the contact closure. |
| INT slp1ContactClosureStatus | 1.3.6.1.4.1.244.1.9.1.2.6.1.4 | INTEGER | read-only | The status of the contact closure. |
| slp1Traps | 1.3.6.1.4.1.244.1.9.1.100 | | | |
| slp1Events | 1.3.6.1.4.1.244.1.9.1.100.0 | | | |
| NTF slp1TowerStatusEvent | 1.3.6.1.4.1.244.1.9.1.100.0.1 | | | Tower status event. If enabled, this trap is sent when the
slp1TowerStatus indicates an error state ('noComm'). This
trap is repeated periodically while the slp1TowerStatus
remains in an error state. If the slp1TowerStatus returns
to a non-error state ('normal'), this trap is sent once more
with the non-error slp1TowerStatus, and then stops being
repeated.
While the slp1TowerStatus indicates an error state, all
status and load traps are suppressed for input feeds and
outlets on the tower. |
| NTF slp1InfeedStatusEvent | 1.3.6.1.4.1.244.1.9.1.100.0.2 | | | Input feed status event. If enabled, this trap is sent when
the slp1InfeedStatus indicates an error state ('offError',
'onError', or 'noComm'). This trap is repeated periodically
while the slp1InfeedStatus remains in an error state. If
the slp1InfeedStatus returns to a non-error state ('off' or
'on'), this trap is sent once more with the non-error
slp1InfeedStatus, and then stops being repeated.
While the slp1InfeedStatus indicates an error state, load
traps are suppressed for the input feed, and, if the
slp1InfeedCapabilities 'failSafe' bit is FALSE, all status
and load traps are suppressed for outlets on the input feed. |
| NTF slp1InfeedLoadEvent | 1.3.6.1.4.1.244.1.9.1.100.0.3 | | | Input feed load event. If enabled, this trap is sent when
the slp1InfeedLoadStatus indicates an error state ('loadLow',
'loadHigh', 'overLoad', 'readError', or 'noComm'). This
trap is repeated periodically while the slp1InfeedLoadStatus
remains in an error state. If the slp1InfeedLoadStatus
returns to a non-error state ('normal' or 'notOn'), this trap
is sent once more with the non-error slp1InfeedLoadStatus,
and then stops being repeated. |
| NTF slp1OutletStatusEvent | 1.3.6.1.4.1.244.1.9.1.100.0.4 | | | Outlet status event. If enabled, this trap is sent when the
slp1OutletStatus indicates an error state ('offError',
'onError', or 'noComm'). This trap is repeated periodically
while the slp1OutletStatus remains in an error state. If
the slp1OutletStatus returns to a non-error state ('off' or
'on'), this trap is sent once more with the non-error
slp1OutletStatus, and then stops being repeated.
While the slp1OutletStatus indicates an error state, load
traps are suppressed for the outlet. |
| NTF slp1OutletLoadEvent | 1.3.6.1.4.1.244.1.9.1.100.0.5 | | | Outlet load event. If enabled, this trap is sent when the
slp1OutletLoadStatus indicates an error state ('loadLow',
'loadHigh', 'overLoad', 'readError', or 'noComm'). This
trap is repeated periodically while the slp1OutletLoadStatus
remains in an error state. If the slp1OutletLoadStatus
returns to a non-error state ('normal' or 'notOn'), this trap
is sent once more with the non-error slp1OutletLoadStatus,
and then stops being repeated. |
| NTF slp1OutletChangeEvent | 1.3.6.1.4.1.244.1.9.1.100.0.6 | | | Outlet on/off change event. If enabled, this trap is sent
when the slp1OutletStatus changes from any 'on' state ('on',
'onWait' or 'onError') to any 'off' state ('off', 'offWait'
or 'offError'), and vice-versa. |
| NTF slp1EnvMonStatusEvent | 1.3.6.1.4.1.244.1.9.1.100.0.7 | | | Environmental monitor status event. If enabled, this trap
is sent when the slp1EnvMonStatus indicates an error state
('noComm'). This trap is repeated periodically while the
slp1EnvMonStatus remains in an error state. If the
slp1EnvMonStatus returns to a non-error state ('normal'),
this trap is sent once more with the non-error
slp1EnvMonStatus, and then stops being repeated.
While the slp1EnvMonStatus indicates an error state, all
status traps are suppressed for the water sensor, ADC,
temperature/humudity sensors, and contact closures on the
environmental monitor. |
| NTF slp1EnvMonWaterSensorEvent | 1.3.6.1.4.1.244.1.9.1.100.0.8 | | | Environmental monitor water sensor event. If enabled, this
trap is sent when the slp1EnvMonWaterSensorStatus indicates
an error state ('alarm'). This trap is repeated periodically
while the slp1EnvMonWaterSensorStatus remains in an error
state. If the slp1EnvMonWaterSensorStatus returns to a
non-error state ('normal'), this trap is sent once more with
the non-error slp1EnvMonWaterSensorStatus, and then stops
being repeated. |
| NTF slp1EnvMonADCEvent | 1.3.6.1.4.1.244.1.9.1.100.0.9 | | | Environmental monitor analog-to-digital converter event.
If enabled, this trap is sent when the slp1EnvMonADCStatus
indicates an error state ('countLow' or 'countHigh'). This
trap is repeated periodically while the slp1EnvMonADCStatus
remains in an error state. If the slp1EnvMonADCStatus
returns to a non-error state ('normal'), this trap is sent
once more with the non-error slp1EnvMonADCStatus, and then
stops being repeated. |
| NTF slp1TempHumidSensorStatusEvent | 1.3.6.1.4.1.244.1.9.1.100.0.10 | | | Temperature/humidity sensor status event. If enabled, this
trap is sent when the slp1TempHumidSensorStatus indicates an
error state ('lost'). This trap is repeated periodically
while the slp1TempHumidSensorStatus remains in an error
state. If the slp1TempHumidSensorStatus returns to a
non-error state ('found'), this trap is sent once more with
the non-error slp1TempHumidSensorStatus, and then stops
being repeated.
While the slp1TempHumidSensorStatus indicates an error state,
all temperature and humidity status traps are suppressed for
the temperature/humudity sensor. |
| NTF slp1TempHumidSensorTempEvent | 1.3.6.1.4.1.244.1.9.1.100.0.11 | | | Temperature/humidity sensor temperature event. If enabled,
this trap is sent when the slp1TempHumidSensorTempStatus
indicates an error state ('tempLow' or 'tempHigh').
This trap is repeated periodically while the
slp1TempHumidSensorTempStatus remains in an error state.
If the slp1TempHumidSensorTempStatus returns to a non-error
state ('normal'), this trap is sent once more with the
non-error slp1TempHumidSensorTempStatus, and then stops
being repeated. |
| NTF slp1TempHumidSensorHumidEvent | 1.3.6.1.4.1.244.1.9.1.100.0.12 | | | Temperature/humidity sensor humidity event. If enabled,
this trap is sent when the slp1TempHumidSensorHumidStatus
indicates an error state ('humidLow' or 'humidHigh').
This trap is repeated periodically while the
slp1TempHumidSensorHumidStatus remains in an error state.
If the slp1TempHumidSensorHumidStatus returns to a non-error
state ('normal'), this trap is sent once more with the
non-error slp1TempHumidSensorHumidStatus, and then stops
being repeated. |
| NTF slp1ContactClosureEvent | 1.3.6.1.4.1.244.1.9.1.100.0.13 | | | Contact closure event. If enabled, this trap is sent when
the slp1ContactClosureStatus indicates an error state
('alarm'). This trap is repeated periodically while the
slp1ContactClosureStatus remains in an error state. If the
slp1ContactClosureStatus returns to a non-error state
('normal'), this trap is sent once more with the non-error
slp1ContactClosureStatus, and then stops being repeated. |