All MIBs › SOCOMECUPS-MIB › upsControlDelay
upsControlDelay
Module: SOCOMECUPS-MIB
OID (symbolic): SOCOMECUPS-MIB::upsControlDelay
OID (numeric): 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The Delay after the occurance of the curresponding shutdown event that Net Vision should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the configured Shutdowntime when Net Vision will start sending the warning message to the connected clients. The value is in units of minutes.
What is upsControlDelay?
Sets how many minutes after the corresponding shutdown event occurs that Net Vision should issue the shutdown warning/request to connected clients (or, for scheduled shutdowns, how far ahead of the configured shutdown time the warning starts). Lets admins tune the client warning lead time per event type.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3 snmpwalk -v2c -c public <target> SOCOMECUPS-MIB::upsControlDelay
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3.1 snmpget -v2c -c public <target> SOCOMECUPS-MIB::upsControlDelay.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> upsControlDelay.1
Start monitoring Socomec UPS, power protection equipment (battery/input-output/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SOCOMECUPS-MIB::upsControlDelay OID value, configure state conditions and alerts, and monitor any Socomec UPS, power protection equipment (battery/input-output/alarm status) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4555 | socomec | SOCOMECPDU-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4555.1 | software | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1 | network | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1 | netvision | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1.1 | upsObjects | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1.1.8 | upsControl | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1.1.8.4 | upsControlShutdownParametersTable | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1.1.8.4.1 | shutdownParametersEntry | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3 | upsControlDelay | SOCOMECUPS-MIB |