All MIBs › SOCOMECUPS-MIB-v2
Category: Environmental Monitoring and Power, Socomec Power Management
Description: Manages Socomec UPS v2 power configuration, battery health, input/output parameters, and alarm notifications.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is SOCOMECUPS-MIB-v2?
SOCOMECUPS-MIB-v2 is a vendor MIB from Socomec (Sicon product line) for managing UPS/PDU power devices, exposing device identity, agent software details, and system time/NTP synchronization configuration for the management agent itself. It covers configuration data such as manufacturer/model identity, agent MIB and software version, and network/NTP time settings, which underpin accurate timestamping of power events and alarms. Its monitoring relevance centers on device and software status: administrators verify ipduIdentAgentSoftwareVersion to track firmware currency across a UPS/PDU fleet, and confirm ipduAgentTimerFromNtp/ipduAgentNtpIpAddress are properly synchronized so that logged power events have accurate timestamps. It shares the same product family (Socomec Sicon) as SOCOMECPDU-MIB, indicating these UPS and PDU MIBs are commonly deployed and cross-referenced together. Typical deployment is in data-center or telecom facilities where Socomec UPS/PDU units protect and distribute power to critical IT equipment, monitored via SNMP for both electrical and management-agent health, and administrators can download the SOCOMECUPS-MIB-v2 file to load into their MIB browser before beginning this monitoring setup.
IPNetwork Monitor allows you to monitor SNMP objects defined in SOCOMECUPS-MIB-v2. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Socomec Sicon UPS
- Socomec PDU
Monitoring Examples
An administrator would poll ipduIdentManufacturer, ipduIdentModel, and ipduIdentAgentSoftwareVersion to inventory UPS agent firmware versions across a fleet and flag units needing an update. Checking ipduAgentTimeDate/ipduAgentTimeTime against ipduAgentTimerFromNtp and ipduAgentNtpIpAddress confirms the unit's clock is properly synced via NTP, which matters for correlating alarm timestamps during a power event. A misconfigured ipduAgentNetworkIpAdress or NTP setting would explain inconsistent event timestamps seen when cross-referencing logs from multiple Socomec units.
What Can Be Monitored
- agent/firmware software version
- device identity/model
- NTP time synchronization status
- system date/time configuration
- network IP configuration
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| socomecSicon | 1.3.6.1.4.1.4555 | |||
| product | 1.3.6.1.4.1.4555.1 | |||
| pduAgent | 1.3.6.1.4.1.4555.1.1 | |||
| iPDU | 1.3.6.1.4.1.4555.1.1.20 | |||
| ipduObjects | 1.3.6.1.4.1.4555.1.1.20.1 | |||
| ipduIdent | 1.3.6.1.4.1.4555.1.1.20.1.1 | |||
| STR ipduIdentManufacturer | 1.3.6.1.4.1.4555.1.1.20.1.1.1 | DisplayString | read-write | The name of manufacturer. |
| STR ipduIdentModel | 1.3.6.1.4.1.4555.1.1.20.1.1.2 | DisplayString | read-write | The Model designation of device. |
| STR ipduIdentAgentSoftwareVersion | 1.3.6.1.4.1.4555.1.1.20.1.1.3 | DisplayString | read-only | The firmware version of the device. |
| STR ipduIdentName | 1.3.6.1.4.1.4555.1.1.20.1.1.4 | DisplayString | read-write | A description of this device. |
| ipduAgent | 1.3.6.1.4.1.4555.1.1.20.1.2 | |||
| ipduAgentConfig | 1.3.6.1.4.1.4555.1.1.20.1.2.1 | |||
| INT ipduAgentMibVersion | 1.3.6.1.4.1.4555.1.1.20.1.2.1.1 | INTEGER | read-only | The Mib Version implemented on this device. |
| ipduAgentLog | 1.3.6.1.4.1.4555.1.1.20.1.2.1.4 | |||
| INT pduAgentDataLogInterval | 1.3.6.1.4.1.4555.1.1.20.1.2.1.4.1 | INTEGER | read-write | The interval of the updation of the data log. The value is in seconds |
| ipduAgentControl | 1.3.6.1.4.1.4555.1.1.20.1.2.1.5 | |||
| INT ipduAgentControlDefault | 1.3.6.1.4.1.4555.1.1.20.1.2.1.5.1 | INTEGER | read-write | Reset all parameters of the agent to default value. |
| INT ipduAgentControlRestart | 1.3.6.1.4.1.4555.1.1.20.1.2.1.5.2 | INTEGER | read-write | Restart the agent. |
| ipduAgentTrap | 1.3.6.1.4.1.4555.1.1.20.1.2.1.6 | |||
| INT ipduAgentTrapRetryCount | 1.3.6.1.4.1.4555.1.1.20.1.2.1.6.1 | INTEGER | read-write | The count of repeat traps send to NMS before trap acknowledgement received. |
| INT ipduAgentTrapRetryTime | 1.3.6.1.4.1.4555.1.1.20.1.2.1.6.2 | INTEGER | read-write | The time interval in seconds between retry traps sned to NMS. |
| INT ipduAgentTrapAckSignature | 1.3.6.1.4.1.4555.1.1.20.1.2.1.6.3 | INTEGER | read-write | The signature of trap acknowledgement. |
| ipduAgentTrapsReceiversTable | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7 | not-accessible | A list of managers to send traps to. The number of entries is given by the value of agentConfigNumTrapReceivers | |
| ipduAgentTrapsReceiversEntry | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1 | not-accessible | The managers to send traps to. | |
| INT trapsIndex | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.1 | INTEGER | read-only | The index to a trap receiver entry. |
| IP trapsReceiverAddr | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.2 | IpAddress | read-write | The IP address of the manager to send a trap to. |
| STR receiverCommunityString | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.3 | DisplayString | read-write | The community name to use in the trap when sent to the manager. |
| INT receiverNmsType | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.4 | INTEGER | read-write | The trap group that NMS desired. |
| INT receiverSeverityLevel | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.5 | INTEGER | read-write | The severity level of traps to be received by this manager. |
| STR receiverDescription | 1.3.6.1.4.1.4555.1.1.20.1.2.1.7.1.6 | DisplayString | read-write | Description of trap receivers |
| ipduAgentAccessControlTable | 1.3.6.1.4.1.4555.1.1.20.1.2.1.8 | not-accessible | A list of managers which can access the device with private community string. | |
| ipduAgentAccessControlEntry | 1.3.6.1.4.1.4555.1.1.20.1.2.1.8.1 | not-accessible | The managers. | |
| INT accessIndex | 1.3.6.1.4.1.4555.1.1.20.1.2.1.8.1.1 | INTEGER | read-only | The index to a access control entry. |
| IP accessControlAddr | 1.3.6.1.4.1.4555.1.1.20.1.2.1.8.1.2 | IpAddress | read-write | The IP address of the manager to access the device. |
| INT accessControlMode | 1.3.6.1.4.1.4555.1.1.20.1.2.1.8.1.3 | INTEGER | read-write | Access type, only read/Write access type can change parameter of the device. |
| ipduAgentTime | 1.3.6.1.4.1.4555.1.1.20.1.2.2 | |||
| STR ipduAgentTimeDate | 1.3.6.1.4.1.4555.1.1.20.1.2.2.1 | DisplayString | read-write | The date in agent, format is (dd/mm/yyyy) |
| STR ipduAgentTimeTime | 1.3.6.1.4.1.4555.1.1.20.1.2.2.2 | DisplayString | read-write | The time in agent, format is (hh:mm:ss) |
| INT ipduAgentTimerFromNtp | 1.3.6.1.4.1.4555.1.1.20.1.2.2.3 | INTEGER | read-write | Enable or disable the agent to synchronize date/time with NTP server. |
| IP ipduAgentNtpIpAddress | 1.3.6.1.4.1.4555.1.1.20.1.2.2.4 | IpAddress | read-write | The ip address of NTP server. |
| INT ipduAgentNtpTimeZone | 1.3.6.1.4.1.4555.1.1.20.1.2.2.5 | INTEGER | read-write | Time Zone to use when synchronize with NTP server. |
| INT ipduAgentDayLightSaving | 1.3.6.1.4.1.4555.1.1.20.1.2.2.6 | INTEGER | read-write | Enable/disable the Day Light Saving when synchronize with NTP server. |
| ipduAgentNetwork | 1.3.6.1.4.1.4555.1.1.20.1.2.3 | |||
| ipduAgentNetworkIp | 1.3.6.1.4.1.4555.1.1.20.1.2.3.1 | |||
| IP ipduAgentNetworkIpAdress | 1.3.6.1.4.1.4555.1.1.20.1.2.3.1.1 | IpAddress | read-write | The ip address that NMS can identify the managed device. |
| IP ipduAgentNetworkIpGateway | 1.3.6.1.4.1.4555.1.1.20.1.2.3.1.2 | IpAddress | read-write | The default gateway that allow device managed through routers. |
| IP ipduAgentNetworkIpSubnet | 1.3.6.1.4.1.4555.1.1.20.1.2.3.1.3 | IpAddress | read-write | Internet address subnet mask |
| INT ipduAgentNetworkDhcpControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.2 | INTEGER | read-write | Enable/disable DHCP protocol |
| INT ipduAgentNetworkPingControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.3 | INTEGER | read-write | Enable/disable to response to PING request. |
| INT ipduAgentNetworkTftpControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.4 | INTEGER | read-write | Enable/disable TFTP protocol |
| ipduAgentNetworkTelnet | 1.3.6.1.4.1.4555.1.1.20.1.2.3.5 | |||
| INT ipduAgentTelnetControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.5.1 | INTEGER | read-write | Enable/disable Telnet protocol. |
| INT ipduAgentTelnetPort | 1.3.6.1.4.1.4555.1.1.20.1.2.3.5.2 | INTEGER | read-write | The TCP port for telnet |
| ipduAgentNetworkHttp | 1.3.6.1.4.1.4555.1.1.20.1.2.3.6 | |||
| INT ipduAgentHttpControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.6.1 | INTEGER | read-write | Enable/disable HTTP protocol. |
| INT ipduAgentHttpPort | 1.3.6.1.4.1.4555.1.1.20.1.2.3.6.2 | INTEGER | read-write | The TCP port for HTTP. |
| ipduAgentNetworkSnmp | 1.3.6.1.4.1.4555.1.1.20.1.2.3.7 | |||
| INT ipduAgentSnmpControl | 1.3.6.1.4.1.4555.1.1.20.1.2.3.7.1 | INTEGER | read-write | Enable/disable SNMP protocol. |
| INT ipduAgentSnmpPort | 1.3.6.1.4.1.4555.1.1.20.1.2.3.7.2 | INTEGER | read-write | The UDP port for SNMP. |
| ipduDevice | 1.3.6.1.4.1.4555.1.1.20.1.3 | |||
| ipduDeviceInlet | 1.3.6.1.4.1.4555.1.1.20.1.3.1 | |||
| INT ipduDeviceInletNumber | 1.3.6.1.4.1.4555.1.1.20.1.3.1.1 | INTEGER | read-only | The inlet number on this device. |
| ipduDeviceInletConfigTable | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2 | not-accessible | A list of inlet on this device. | |
| ipduDeviceInletConfigEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1 | not-accessible | The inlet number of device. | |
| INT inletConfigIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.1 | INTEGER | read-only | The index to a access inlet configuration table. |
| STR inletConfigDesc | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.2 | DisplayString | read-write | A Description of inlet of device. |
| INT inletConfigVoltageHigh | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.3 | INTEGER | read-write | The Inlet high voltage threshold, in volts. |
| INT inletConfigVoltageHighAction | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4 | INTEGER | read-write | Reaction of the device when inlet voltage higher than set point. |
| INT inletConfigVoltageLow | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.5 | INTEGER | read-write | The Inlet low voltage threshold, in volts. |
| INT inletConfigVoltageLowAction | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.6 | INTEGER | read-write | Reaction of the device when inlet voltage lower than set point. |
| INT inletConfigCurrentHigh | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.7 | INTEGER | read-write | The Inlet low voltage threshold, in 0.1 amps. |
| INT inletConfigCurrentHighAction | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.8 | INTEGER | read-write | Reaction of the device when inlet current higher than set point. |
| INT inletConfigFrequencyHigh | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.9 | INTEGER | read-write | The Inlet high frequency threshold, in hz. |
| INT inletConfigfrequencyHighAction | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.10 | INTEGER | read-write | Reaction of the device when inlet frequency higher than set point. |
| INT inletConfigFrequencyLow | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.11 | INTEGER | read-write | The Inlet low frequency threshold, in hz. |
| INT inletConfigfrequencyLowAction | 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12 | INTEGER | read-write | Reaction of the device when inlet frequency lower than set point. |
| ipduDeviceInletStatusTable | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3 | not-accessible | A list of inlet on this device. | |
| ipduDeviceInletStatusEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1 | not-accessible | The inlet number of device. | |
| INT inletStatusIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.1 | INTEGER | read-only | The index to a access inlet configuration table. |
| INT inletStatusVoltage | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.2 | INTEGER | read-only | The Inlet Voltage in 0.1 volts |
| INT inletStatusCurrent | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.3 | INTEGER | read-only | The Inlet Current in 0.001 Amp. |
| INT inletStatusFrequency | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.4 | INTEGER | read-only | The Inlet Frequency in 0.1 Hz |
| INT inletStatusKwatt | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.5 | INTEGER | read-only | The Inlet Kwatt in 0.1 KW/H |
| INT inletStatusWH | 1.3.6.1.4.1.4555.1.1.20.1.3.1.3.1.6 | INTEGER | read-only | The Inlet Kwatt in 0.1 W/H |
| INT inletWattReset | 1.3.6.1.4.1.4555.1.1.20.1.3.1.4 | INTEGER | read-write | Reset inlet kw. |
| ipduDeviceOutlet | 1.3.6.1.4.1.4555.1.1.20.1.3.2 | |||
| INT ipduDeviceOutletNumber | 1.3.6.1.4.1.4555.1.1.20.1.3.2.1 | INTEGER | read-only | The outlet number on this device. |
| ipduDeviceOutletConfigTable | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2 | not-accessible | A list of outlet on this device. | |
| ipduDeviceOutletConfigEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1 | not-accessible | The inlet number of device. | |
| INT outletConfigIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.1 | INTEGER | read-only | The index to a access inlet configuration table. |
| STR outletConfigDesc | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.2 | DisplayString | read-write | A Description of outlet of device. |
| STR outletConfigLocation | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.3 | DisplayString | read-write | Location of device connectted to this outlet. |
| INT outletConfigOnDelay | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.4 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT outletConfigOffDelay | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.5 | INTEGER | read-write | The delay time before turn off tis outlet, in seconds. |
| INT outletConfigCurrentHigh | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.6 | INTEGER | read-write | The outlet high current threshold, in amp. |
| INT outletConfigCurrentHighAction | 1.3.6.1.4.1.4555.1.1.20.1.3.2.2.1.7 | INTEGER | read-write | Reaction of the device when outlet current higher than set point. |
| ipduDeviceOutletStatusTable | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3 | not-accessible | A list of outlet on this device. | |
| ipduDeviceOutletStatusEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1 | not-accessible | The outlet number of device. | |
| INT outletStatusIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT outletStatusStatus | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.2 | INTEGER | read-only | Outlet state |
| INT outletStatusCurrent | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.3 | INTEGER | read-only | The outlet Current in 0.001 Amp. |
| INT outletStatusKwatt | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.4 | INTEGER | read-only | The outlet Kwatt in 0.001 KW/H. |
| INT outletStatusWH | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.5 | INTEGER | read-only | The outlet Watt in 0.1 W/H. |
| INT outletStatusStateTime | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.6 | INTEGER | read-only | Time in seconds since the outlet changed to current state. |
| INT outletStatusTimeToGo | 1.3.6.1.4.1.4555.1.1.20.1.3.2.3.1.7 | INTEGER | read-only | Remain time the outlet state will be changed by agent, in seconds |
| ipduDeviceOutletControlTable | 1.3.6.1.4.1.4555.1.1.20.1.3.2.4 | not-accessible | A list of outlet on this device. | |
| ipduDeviceOutletControlEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.2.4.1 | not-accessible | The outlet number of device. | |
| INT outletControlIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.2.4.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT outletControlControl | 1.3.6.1.4.1.4555.1.1.20.1.3.2.4.1.2 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT ipduDeviceOutletControlAll | 1.3.6.1.4.1.4555.1.1.20.1.3.2.5 | INTEGER | read-write | Set to control all outlets perform action as requested. |
| INT ipduDeviceOutletWattReset | 1.3.6.1.4.1.4555.1.1.20.1.3.2.6 | INTEGER | read-write | Reset outlet kw. |
| ipduDeviceCcOut | 1.3.6.1.4.1.4555.1.1.20.1.3.3 | |||
| INT ipduDeviceCcOutNumber | 1.3.6.1.4.1.4555.1.1.20.1.3.3.1 | INTEGER | read-only | The contact closure output number on this device. |
| ipduDeviceCcOutConfigTable | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2 | not-accessible | A list of contact closure output on this device. | |
| ipduDeviceCcOutConfigEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1 | not-accessible | The CC number of device. | |
| INT ccOutConfigIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1.1 | INTEGER | read-only | The index to access contact closure output configuration table. |
| STR ccOutConfigDesc | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1.2 | DisplayString | read-write | A Description of a contact closure output of device. |
| INT ccOutConfigEventAction | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1.3 | INTEGER | read-write | Enable/disble the contact closure output to react to events. |
| INT ccOutConfigCloseDelay | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1.4 | INTEGER | read-write | The delay time in seconds when the contact closure output set to close. |
| INT ccOutConfigOpenDelay | 1.3.6.1.4.1.4555.1.1.20.1.3.3.2.1.5 | INTEGER | read-write | The delay time in seconds when the contact closure output set to open. |
| ipduDeviceCcOutStatusTable | 1.3.6.1.4.1.4555.1.1.20.1.3.3.3 | not-accessible | A list of contact closure output on this device. | |
| ipduDeviceCcOutStatusEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.3.3.1 | not-accessible | The CC number of device. | |
| INT ccOutStatusIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.3.3.1.1 | INTEGER | read-only | The index to access contact closure output configuration table. |
| INT ccOutStatusStatus | 1.3.6.1.4.1.4555.1.1.20.1.3.3.3.1.2 | INTEGER | read-only | State of a contact closure output of device. |
| INT ccOutStatusTimeOnState | 1.3.6.1.4.1.4555.1.1.20.1.3.3.3.1.3 | INTEGER | read-only | Time in seconds since the contact closure output changed to current state. |
| ipduDeviceCcOutControlTable | 1.3.6.1.4.1.4555.1.1.20.1.3.3.4 | not-accessible | A list of contact closure output on this device. | |
| ipduDeviceCcOutControlEntry | 1.3.6.1.4.1.4555.1.1.20.1.3.3.4.1 | not-accessible | The outlet number of device. | |
| INT ccOutControlIndex | 1.3.6.1.4.1.4555.1.1.20.1.3.3.4.1.1 | INTEGER | read-only | The index to a access contact closure output configuration table. |
| INT ccOutControlControl | 1.3.6.1.4.1.4555.1.1.20.1.3.3.4.1.2 | INTEGER | read-write | Set to control the contact closure output perform action as requested. |
| ipduSlave | 1.3.6.1.4.1.4555.1.1.20.1.4 | |||
| ipduSlaveState | 1.3.6.1.4.1.4555.1.1.20.1.4.1 | |||
| ipduSlaveStateTable | 1.3.6.1.4.1.4555.1.1.20.1.4.1.1 | not-accessible | A list of outlet on this device. | |
| ipduSlaveStateEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.1.1.1 | not-accessible | The outlet number of device. | |
| INT slaveStateIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.1.1.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveStateControl01 | 1.3.6.1.4.1.4555.1.1.20.1.4.1.1.1.2 | INTEGER | read-only | Set to control the outlet perform action as requested to slave outlet A |
| ipduSlaveInlet | 1.3.6.1.4.1.4555.1.1.20.1.4.2 | |||
| ipduSlaveInletStatus | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1 | |||
| ipduDeviceSlaveInletStatusTable | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1 | not-accessible | A list of inlet on this device. | |
| ipduDeviceSlaveInletStatusEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1 | not-accessible | The inlet number of device. | |
| INT inletSlaveStatusIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.1 | INTEGER | read-only | The index to a access inlet configuration table. |
| INT inletSlaveStatusVoltage | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.2 | INTEGER | read-only | The Inlet Voltage in 0.1 volts |
| INT inletSlaveStatusCurrent | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.3 | INTEGER | read-only | The Inlet Current in 0.001 Amp. |
| INT inletSlaveStatusFrequency | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.4 | INTEGER | read-only | The Inlet Frequency in 0.1 Hz |
| INT inletSlaveStatusKwatt | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.5 | INTEGER | read-only | The Inlet Kwatt in 0.001 KW/H |
| INT inletSlaveStatusWH | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.6 | INTEGER | read-only | The Inlet Kwatt in 0.001 KW/H |
| INT inletSlaveStatusVoltage2 | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.7 | INTEGER | read-only | The Inlet Voltage in 0.1 volts |
| INT inletSlaveStatusCurrent2 | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.8 | INTEGER | read-only | The Inlet Current in 0.001 Amp. |
| INT inletSlaveStatusFrequency2 | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.9 | INTEGER | read-only | The Inlet Frequency in 0.1 Hz |
| INT inletSlaveStatusKwatt2 | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.10 | INTEGER | read-only | The Inlet Kwatt in 0.001 KW/H |
| INT inletSlaveStatusWH2 | 1.3.6.1.4.1.4555.1.1.20.1.4.2.1.1.1.11 | INTEGER | read-only | The Inlet Kwatt in 0.001 KW/H |
| ipduSlaveInletConfig | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2 | |||
| ipduDeviceslaveInletConfigTable | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1 | not-accessible | A list of inlet on this device. | |
| ipduDeviceslaveInletConfigEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1 | not-accessible | The inlet number of device. | |
| INT slaveInletConfigIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1.1 | INTEGER | read-only | The index to a access inlet configuration table. |
| INT slaveInletConfigVoltageHigh | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1.2 | INTEGER | read-write | The Inlet high voltage threshold, in volts. |
| INT slaveInletConfigVoltageLow | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1.3 | INTEGER | read-write | The Inlet low voltage threshold, in volts. |
| INT slaveInlet2ConfigVoltageHigh | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1.4 | INTEGER | read-write | The Inlet 2 high voltage threshold, in volts. |
| INT slaveInlet2ConfigVoltageLow | 1.3.6.1.4.1.4555.1.1.20.1.4.2.2.1.1.5 | INTEGER | read-write | The Inlet low voltage threshold, in volts. |
| ipduSlaveOutlet | 1.3.6.1.4.1.4555.1.1.20.1.4.3 | |||
| ipduSlaveOutletConfig | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1 | |||
| ipduSlaveDeviceOutletNameTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletNameEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletNameIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| STR slaveOutletName01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.2 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.3 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.4 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.5 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.6 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.7 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.8 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.9 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.10 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.11 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.12 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletName12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.1.1.13 | DisplayString | read-write | A Description of a outlet name of device. |
| ipduSlaveDeviceOutletLocationTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletLocationEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletLocationIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| STR slaveOutletLocation01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.3 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.4 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.5 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.6 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.7 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.8 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.9 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.10 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.11 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.12 | DisplayString | read-write | A Description of a outlet name of device. |
| STR slaveOutletLocation12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.13 | DisplayString | read-write | A Description of a outlet name of device. |
| ipduSlaveDeviceOutletOnTimeTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletOnTimeEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletOnTimeIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletOnTime01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.2 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.3 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.4 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.5 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.6 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.7 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.8 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.9 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.10 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.11 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.12 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOnTime12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.3.1.13 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| ipduSlaveDeviceOutletOffTimeTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletOffTimeEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletOffTimeIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletOffTime01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.2 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.3 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.4 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.5 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.6 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.7 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.8 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.9 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.10 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.11 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.12 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| INT slaveOutletOffTime12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.4.1.13 | INTEGER | read-write | The delay time before turn on tis outlet, in seconds. |
| ipduSlaveDeviceOutletCurrThTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletCurrThEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletCurrThIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletCurrTh01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.2 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.3 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.4 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.5 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.6 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.7 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.8 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.9 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.10 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.11 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.12 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| INT slaveOutletCurrTh12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.5.1.13 | INTEGER | read-write | The Outlet Current Threshold ,in 0.1 Amp. |
| ipduSlaveOutletStatus | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2 | |||
| ipduSlaveDeviceOutletCurrentTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletCurrentEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletCurrentIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletCurrent01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.2 | INTEGER | read-only | The outlet A Current in 0.001 Amp. |
| INT slaveOutletCurrent02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.3 | INTEGER | read-only | The outlet B Current in 0.001 Amp. |
| INT slaveOutletCurrent03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.4 | INTEGER | read-only | The outlet C Current in 0.001 Amp. |
| INT slaveOutletCurrent04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.5 | INTEGER | read-only | The outlet D Current in 0.001 Amp. |
| INT slaveOutletCurrent05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.6 | INTEGER | read-only | The outlet E Current in 0.001 Amp. |
| INT slaveOutletCurrent06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.7 | INTEGER | read-only | The outlet F Current in 0.001 Amp. |
| INT slaveOutletCurrent07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.8 | INTEGER | read-only | The outlet G Current in 0.001 Amp. |
| INT slaveOutletCurrent08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.9 | INTEGER | read-only | The outlet H Current in 0.001 Amp. |
| INT slaveOutletCurrent09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.10 | INTEGER | read-only | The outlet I Current in 0.001 Amp. |
| INT slaveOutletCurrent10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.11 | INTEGER | read-only | The outlet J Current in 0.001 Amp. |
| INT slaveOutletCurrent11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.12 | INTEGER | read-only | The outlet K Current in 0.001 Amp. |
| INT slaveOutletCurrent12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.1.1.13 | INTEGER | read-only | The outlet L Current in 0.001 Amp. |
| ipduSlaveDeviceOutletWattTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletWattEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletWattIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletWatt01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.2 | INTEGER | read-only | The outlet A Watt in 0.1 W/H. |
| INT slaveOutletWatt02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.3 | INTEGER | read-only | The outlet B Watt in 0.1 W/H. |
| INT slaveOutletWatt03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.4 | INTEGER | read-only | The outlet C Watt in 0.1 W/H. |
| INT slaveOutletWatt04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.5 | INTEGER | read-only | The outlet D Watt in 0.1 W/H. |
| INT slaveOutletWatt05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.6 | INTEGER | read-only | The outlet E Watt in 0.1 W/H. |
| INT slaveOutletWatt06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.7 | INTEGER | read-only | The outlet F Watt in 0.1 W/H. |
| INT slaveOutletWatt07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.8 | INTEGER | read-only | The outlet G Watt in 0.1 W/H. |
| INT slaveOutletWatt08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.9 | INTEGER | read-only | The outlet H Watt in 0.1 W/H. |
| INT slaveOutletWatt09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.10 | INTEGER | read-only | The outlet I Watt in 0.1 W/H. |
| INT slaveOutletWatt10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.11 | INTEGER | read-only | The outlet J Watt in 0.1 W/H. |
| INT slaveOutletWatt11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.12 | INTEGER | read-only | The outlet K Watt in 0.1 W/H. |
| INT slaveOutletWatt12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.2.1.13 | INTEGER | read-only | The outlet L Watt in 0.1 W/H. |
| ipduSlaveDeviceOutletKwattTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletKwattEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletKwattIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletKwatt01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.2 | INTEGER | read-only | The outlet A Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.3 | INTEGER | read-only | The outlet B Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.4 | INTEGER | read-only | The outlet C Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.5 | INTEGER | read-only | The outlet D Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.6 | INTEGER | read-only | The outlet E Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.7 | INTEGER | read-only | The outlet F Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.8 | INTEGER | read-only | The outlet G Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.9 | INTEGER | read-only | The outlet H Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.10 | INTEGER | read-only | The outlet I Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.11 | INTEGER | read-only | The outlet J Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.12 | INTEGER | read-only | The outlet K Kwatt in 0.001 KW/H. |
| INT slaveOutletKwatt12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.2.3.1.13 | INTEGER | read-only | The outlet L Kwatt in 0.001 KW/H. |
| ipduSlaveOutletAction | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3 | |||
| ipduSlaveDeviceOutletActionTable | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1 | not-accessible | A list of outlet on this device. | |
| ipduSlaveDeviceOutletActionEntry | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1 | not-accessible | The outlet number of device. | |
| INT slaveOutletActionIndex | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.1 | INTEGER | read-only | The index to a access outlet configuration table. |
| INT slaveOutletAction01 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.2 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction02 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.3 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction03 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.4 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction04 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.5 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction05 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.6 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction06 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.7 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction07 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.8 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction08 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.9 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction09 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.10 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction10 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.11 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction11 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.12 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| INT slaveOutletAction12 | 1.3.6.1.4.1.4555.1.1.20.1.4.3.3.1.1.13 | INTEGER | read-write | Set to control the outlet perform action as requested. |
| ipduEnv | 1.3.6.1.4.1.4555.1.1.20.1.5 | |||
| ipduEnvEmd | 1.3.6.1.4.1.4555.1.1.20.1.5.1 | |||
| ipduEnvEmdStatus | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1 | |||
| INT ipduEnvEmdStatusEmdType | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1.1 | INTEGER | read-only | EMD Type. |
| INT ipduEnvEmdStatusTemperature | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1.2 | INTEGER | read-only | EMD Temperature in 0.1 degree C. |
| INT ipduEnvEmdStatusHumidity | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1.3 | INTEGER | read-only | EMD Humidity in 0.1%. |
| INT ipduEnvEmdStatusAlarm1 | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1.4 | INTEGER | read-only | EMD Alarm-1 state. |
| INT ipduEnvEmdStatusAlarm2 | 1.3.6.1.4.1.4555.1.1.20.1.5.1.1.5 | INTEGER | read-only | EMD Alarm-2 state. |
| ipduEnvEmdConfig | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2 | |||
| INT ipduEnvEmdConfigEmdPresence | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.1 | INTEGER | read-write | Configure the EMD presence by auto-detect or not exist (disabled). |
| STR ipduEnvEmdConfigEmdName | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.2 | DisplayString | read-write | The name of Emd. |
| ipduEnvEmdConfigTemp | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3 | |||
| STR ipduEnvEmdConfigTempName | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.1 | DisplayString | read-write | The name of EMD Temperature sensor. |
| INT ipduEnvEmdConfigTempHighSetPoint | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.2 | INTEGER | read-write | EMD Temperature set point high, alarm will active when temperature over this value, in degree C. |
| INT ipduEnvEmdConfigTempHighStatus | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.3 | INTEGER | read-write | Enabled/disabled the high setpoint be applied or not |
| INT ipduEnvEmdConfigTempLowSetPoint | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.4 | INTEGER | read-write | EMD Temperature set point high, alarm will active when temperature under this value, in degree C. |
| INT ipduEnvEmdConfigTempLowStatus | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.5 | INTEGER | read-write | Enabled/disabled the low setpoint be applied or not |
| INT ipduEnvEmdConfigTempOffset | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.3.6 | INTEGER | read-write | Offset of temperature in degree C to adjust EMD temperature measurement. |
| ipduEnvEmdConfigHumi | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4 | |||
| STR ipduEnvEmdConfigHumiName | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.1 | DisplayString | read-write | The name of EMD Humidity. |
| INT ipduEnvEmdConfigHumiHighSetPoint | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.2 | INTEGER | read-write | EMD humidity set point high, alarm will active when humidity over this value, in %. |
| INT ipduEnvEmdConfigHumiHighStatus | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.3 | INTEGER | read-write | Enabled/disabled the high setpoint be applied or not |
| INT ipduEnvEmdConfigHumiLowSetPoint | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.4 | INTEGER | read-write | EMD humidity set point low, alarm will active when humidity under this value, in %. |
| INT ipduEnvEmdConfigHumiLowStatus | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.5 | INTEGER | read-write | Enabled/disabled the high setpoint be applied or not |
| INT ipduEnvEmdConfigHumiOffset | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.4.6 | INTEGER | read-write | Emd Hum Offset; |
| ipduEnvEmdConfigAlarm1 | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.5 | |||
| STR ipduEnvEmdConfigAlarm1Name | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.5.1 | DisplayString | read-write | The name of EMD Alarm-1. |
| INT ipduEnvEmdConfigAlarm1Type | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.5.2 | INTEGER | read-write | EMD Alarm-1 type |
| ipduEnvEmdConfigAlarm2 | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.6 | |||
| STR ipduEnvEmdConfigAlarm2Name | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.6.1 | DisplayString | read-write | The name of EMD Alarm-2. |
| INT ipduEnvEmdConfigAlarm2Type | 1.3.6.1.4.1.4555.1.1.20.1.5.1.2.6.2 | INTEGER | read-write | EMD Alarm-2 type |
| ipduTraps | 1.3.6.1.4.1.4555.1.1.20.2 | |||
| NTF ipduInletVoltageTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.1 | CRITICAL: The input voltage over high threshold. | ||
| NTF ipduInletVoltageNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.2 | WARNING: The input voltage return from over high threshold. | ||
| NTF ipduInletVoltageTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.3 | CRITICAL: The input voltage under low threshold. | ||
| NTF ipduInletVoltageNotTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.4 | WARNING: The input voltage return from under low threshold. | ||
| NTF ipduInletCurrentTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.5 | CRITICAL: The input current over high threshold. | ||
| NTF ipduInletCurrentNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.6 | WARNING: The input current return from over high threshold. | ||
| NTF ipduInletFrequencyTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.7 | CRITICAL: The input frequency over high threshold. | ||
| NTF ipduInletFrequencyNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.8 | WARNING: The input frequency return from over high threshold. | ||
| NTF ipduInletFrequencyTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.9 | CRITICAL: The input frequency under low threshold. | ||
| NTF ipduInletFrequencyNotTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.10 | WARNING: The input frequency return from under low threshold. | ||
| NTF ipduInlet2VoltageTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.11 | CRITICAL: The input2 voltage over high threshold. | ||
| NTF ipduInlet2VoltageNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.12 | WARNING: The input2 voltage return from over high threshold. | ||
| NTF ipduInlet2VoltageTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.13 | CRITICAL: The input2 voltage under low threshold. | ||
| NTF ipduInlet2VoltageNotTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.14 | WARNING: The input2 voltage return from under low threshold. | ||
| NTF ipduInlet2CurrentTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.15 | CRITICAL: The input2 current over high threshold. | ||
| NTF ipduInlet2CurrentNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.16 | WARNING: The input2 current return from over high threshold. | ||
| NTF ipduInlet2FrequencyTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.17 | CRITICAL: The input2 frequency over high threshold. | ||
| NTF ipduInlet2FrequencyNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.18 | WARNING: The input2 frequency return from over high threshold. | ||
| NTF ipduInlet2FrequencyTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.19 | CRITICAL: The input2 frequency under low threshold. | ||
| NTF ipduInlet2FrequencyNotTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.20 | WARNING: The input2 frequency return from under low threshold. | ||
| NTF ipduOutletCurrentTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.21 | CRITICAL: The output current of outlet over high threshold. | ||
| NTF ipduOutletCurrentNotTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.22 | WARNING: The output current of outlet return from over high threshold. | ||
| NTF ipduOutletStateChanged | 1.3.6.1.4.1.4555.1.1.20.2.0.23 | INFORMATION: The outlet state had changed from on to off, or from off to on. | ||
| NTF ipduEmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.24 | INFORMATION: emd Temperature Not High. | ||
| NTF ipduEmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.25 | WARNING: emd Temperature Too High. | ||
| NTF ipduEmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.26 | INFORMATION: emd Temperature Not Low. | ||
| NTF ipduEmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.27 | WARNING: emd Temperature Too Low. | ||
| NTF ipduEmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.28 | INFORMATION: emd Humidity Not High. | ||
| NTF ipduEmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.29 | WARNING: emd Humidity Too High. | ||
| NTF ipduEmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.30 | INFORMATION: emd Humidity Not Low. | ||
| NTF ipduEmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.31 | WARNING: emd Humidity Too Low. | ||
| NTF ipduEmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.32 | INFORMATION: emd Alarm1 Normal. | ||
| NTF ipduEmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.33 | WARNING: emd Alarm1 Active. | ||
| NTF ipduEmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.34 | INFORMATION: emd Alarm2 Normal. | ||
| NTF ipduEmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.35 | WARNING: emd Alarm2 Active. | ||
| NTF ipduSlave01Inlet01OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.36 | CRITICAL: The Slave01 input01 voltage over high threshold. | ||
| NTF ipduSlave01Inlet01NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.37 | CRITICAL: The Slave01 input01 voltage Not over high threshold. | ||
| NTF ipduSlave01Inlet02OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.38 | CRITICAL: The Slave01 input02 voltage over high threshold. | ||
| NTF ipduSlave01Inlet02NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.39 | CRITICAL: The Slave01 input02 voltage Not over high threshold. | ||
| NTF ipduSlave01Inlet01UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.40 | CRITICAL: The Slave01 input01 voltage under low threshold. | ||
| NTF ipduSlave01Inlet01NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.41 | CRITICAL: The Slave01 input01 voltage Not under low threshold. | ||
| NTF ipduSlave01Inlet02UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.42 | CRITICAL: The Slave01 input02 voltage under low threshold. | ||
| NTF ipduSlave01Inlet02NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.43 | CRITICAL: The Slave01 input02 voltage Not under low threshold. | ||
| NTF ipduSlave01Inlet01CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.44 | CRITICAL: The Slave01 input01 current over high threshold. | ||
| NTF ipduSlave01Inlet01NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.45 | CRITICAL: The Slave01 input01 current not over high threshold. | ||
| NTF ipduSlave01Inlet02CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.46 | CRITICAL: The Slave01 input02 current over high threshold. | ||
| NTF ipduSlave01Inlet02NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.47 | CRITICAL: The Slave01 input02 current not over high threshold. | ||
| NTF ipduSlave01EmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.48 | INFORMATION: The Slave01 emd Temperature Not High. | ||
| NTF ipduSlave01EmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.49 | WARNING: The Slave01 emd Temperature Too High. | ||
| NTF ipduSlave01EmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.50 | INFORMATION: The Slave01 emd Temperature Not Low. | ||
| NTF ipduSlave01EmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.51 | WARNING: The Slave01 emd Temperature Too Low. | ||
| NTF ipduSlave01EmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.52 | INFORMATION: The Slave01 emd Humidity Not High. | ||
| NTF ipduSlave01EmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.53 | WARNING: The Slave01 emd Humidity Too High. | ||
| NTF ipduSlave01EmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.54 | INFORMATION: The Slave01 emd Humidity Not Low. | ||
| NTF ipduSlave01EmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.55 | WARNING: The Slave01 emd Humidity Too Low. | ||
| NTF ipduSlave01EmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.56 | INFORMATION: The Slave01 emd Alarm1 Normal. | ||
| NTF ipduSlave01EmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.57 | WARNING: The Slave01 emd Alarm1 Active. | ||
| NTF ipduSlave01EmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.58 | INFORMATION: The Slave01 emd Alarm2 Normal. | ||
| NTF ipduSlave01EmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.59 | WARNING: The Slave01 emd Alarm2 Active. | ||
| NTF ipduSlave01OutletCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.60 | WARNING: The Slave01 Outlet Current over threshold. | ||
| NTF ipduSlave02Inlet01OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.61 | CRITICAL: The Slave02 input01 voltage over high threshold. | ||
| NTF ipduSlave02Inlet01NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.62 | CRITICAL: The Slave02 input01 voltage Not over high threshold. | ||
| NTF ipduSlave02Inlet02OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.63 | CRITICAL: The Slave02 input02 voltage over high threshold. | ||
| NTF ipduSlave02Inlet02NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.64 | CRITICAL: The Slave02 input02 voltage Not over high threshold. | ||
| NTF ipduSlave02Inlet01UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.65 | CRITICAL: The Slave02 input01 voltage under low threshold. | ||
| NTF ipduSlave02Inlet01NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.66 | CRITICAL: The Slave02 input01 voltage Not under low threshold. | ||
| NTF ipduSlave02Inlet02UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.67 | CRITICAL: The Slave02 input02 voltage under low threshold. | ||
| NTF ipduSlave02Inlet02NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.68 | CRITICAL: The Slave02 input02 voltage Not under low threshold. | ||
| NTF ipduSlave02Inlet01CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.69 | CRITICAL: The Slave02 input01 current over high threshold. | ||
| NTF ipduSlave02Inlet01NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.70 | CRITICAL: The Slave02 input01 current not over high threshold. | ||
| NTF ipduSlave02Inlet02CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.71 | CRITICAL: The Slave02 input02 current over high threshold. | ||
| NTF ipduSlave02Inlet02NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.72 | CRITICAL: The Slave02 input02 current not over high threshold. | ||
| NTF ipduSlave02EmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.73 | INFORMATION: The Slave02 emd Temperature Not High. | ||
| NTF ipduSlave02EmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.74 | WARNING: The Slave02 emd Temperature Too High. | ||
| NTF ipduSlave02EmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.75 | INFORMATION: The Slave02 emd Temperature Not Low. | ||
| NTF ipduSlave02EmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.76 | WARNING: The Slave02 emd Temperature Too Low. | ||
| NTF ipduSlave02EmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.77 | INFORMATION: The Slave02 emd Humidity Not High. | ||
| NTF ipduSlave02EmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.78 | WARNING: The Slave02 emd Humidity Too High. | ||
| NTF ipduSlave02EmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.79 | INFORMATION: The Slave02 emd Humidity Not Low. | ||
| NTF ipduSlave02EmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.80 | WARNING: The Slave02 emd Humidity Too Low. | ||
| NTF ipduSlave02EmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.81 | INFORMATION: The Slave02 emd Alarm1 Normal. | ||
| NTF ipduSlave02EmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.82 | WARNING: The Slave02 emd Alarm1 Active. | ||
| NTF ipduSlave02EmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.83 | INFORMATION: The Slave02 emd Alarm2 Normal. | ||
| NTF ipduSlave02EmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.84 | WARNING: The Slave02 emd Alarm2 Active. | ||
| NTF ipduSlave02OutletCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.85 | WARNING: The Slave02 Outlet Current over threshold. | ||
| NTF ipduSlave03Inlet01OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.86 | CRITICAL: The Slave03 input01 voltage over high threshold. | ||
| NTF ipduSlave03Inlet01NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.87 | CRITICAL: The Slave03 input01 voltage Not over high threshold. | ||
| NTF ipduSlave03Inlet02OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.88 | CRITICAL: The Slave03 input02 voltage over high threshold. | ||
| NTF ipduSlave03Inlet02NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.89 | CRITICAL: The Slave03 input02 voltage Not over high threshold. | ||
| NTF ipduSlave03Inlet01UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.90 | CRITICAL: The Slave03 input01 voltage under low threshold. | ||
| NTF ipduSlave03Inlet01NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.91 | CRITICAL: The Slave03 input01 voltage Not under low threshold. | ||
| NTF ipduSlave03Inlet02UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.92 | CRITICAL: The Slave03 input02 voltage under low threshold. | ||
| NTF ipduSlave03Inlet02NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.93 | CRITICAL: The Slave03 input02 voltage Not under low threshold. | ||
| NTF ipduSlave03Inlet01CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.94 | CRITICAL: The Slave03 input01 current over high threshold. | ||
| NTF ipduSlave03Inlet01NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.95 | CRITICAL: The Slave03 input01 current not over high threshold. | ||
| NTF ipduSlave03Inlet02CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.96 | CRITICAL: The Slave03 input02 current over high threshold. | ||
| NTF ipduSlave03Inlet02NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.97 | CRITICAL: The Slave03 input02 current not over high threshold. | ||
| NTF ipduSlave03EmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.98 | INFORMATION: The Slave03 emd Temperature Not High. | ||
| NTF ipduSlave03EmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.99 | WARNING: The Slave03 emd Temperature Too High. | ||
| NTF ipduSlave03EmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.100 | INFORMATION: The Slave03 emd Temperature Not Low. | ||
| NTF ipduSlave03EmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.101 | WARNING: The Slave03 emd Temperature Too Low. | ||
| NTF ipduSlave03EmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.102 | INFORMATION: The Slave03 emd Humidity Not High. | ||
| NTF ipduSlave03EmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.103 | WARNING: The Slave03 emd Humidity Too High. | ||
| NTF ipduSlave03EmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.104 | INFORMATION: The Slave03 emd Humidity Not Low. | ||
| NTF ipduSlave03EmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.105 | WARNING: The Slave03 emd Humidity Too Low. | ||
| NTF ipduSlave03EmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.106 | INFORMATION: The Slave03 emd Alarm1 Normal. | ||
| NTF ipduSlave03EmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.107 | WARNING: The Slave03 emd Alarm1 Active. | ||
| NTF ipduSlave03EmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.108 | INFORMATION: The Slave03 emd Alarm2 Normal. | ||
| NTF ipduSlave03EmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.109 | WARNING: The Slave03 emd Alarm2 Active. | ||
| NTF ipduSlave03OutletCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.110 | WARNING: The Slave03 Outlet Current over threshold. | ||
| NTF ipduSlave04Inlet01OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.111 | CRITICAL: The Slave04 input01 voltage over high threshold. | ||
| NTF ipduSlave04Inlet01NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.112 | CRITICAL: The Slave04 input01 voltage Not over high threshold. | ||
| NTF ipduSlave04Inlet02OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.113 | CRITICAL: The Slave04 input02 voltage over high threshold. | ||
| NTF ipduSlave04Inlet02NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.114 | CRITICAL: The Slave04 input02 voltage Not over high threshold. | ||
| NTF ipduSlave04Inlet01UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.115 | CRITICAL: The Slave04 input01 voltage under low threshold. | ||
| NTF ipduSlave04Inlet01NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.116 | CRITICAL: The Slave04 input01 voltage Not under low threshold. | ||
| NTF ipduSlave04Inlet02UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.117 | CRITICAL: The Slave04 input02 voltage under low threshold. | ||
| NTF ipduSlave04Inlet02NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.118 | CRITICAL: The Slave04 input02 voltage Not under low threshold. | ||
| NTF ipduSlave04Inlet01CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.119 | CRITICAL: The Slave04 input01 current over high threshold. | ||
| NTF ipduSlave04Inlet01NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.120 | CRITICAL: The Slave04 input01 current not over high threshold. | ||
| NTF ipduSlave04Inlet02CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.121 | CRITICAL: The Slave04 input02 current over high threshold. | ||
| NTF ipduSlave04Inlet02NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.122 | CRITICAL: The Slave04 input02 current not over high threshold. | ||
| NTF ipduSlave04EmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.123 | INFORMATION: The Slave04 emd Temperature Not High. | ||
| NTF ipduSlave04EmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.124 | WARNING: The Slave04 emd Temperature Too High. | ||
| NTF ipduSlave04EmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.125 | INFORMATION: The Slave04 emd Temperature Not Low. | ||
| NTF ipduSlave04EmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.126 | WARNING: The Slave04 emd Temperature Too Low. | ||
| NTF ipduSlave04EmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.127 | INFORMATION: The Slave04 emd Humidity Not High. | ||
| NTF ipduSlave04EmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.128 | WARNING: The Slave04 emd Humidity Too High. | ||
| NTF ipduSlave04EmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.129 | INFORMATION: The Slave04 emd Humidity Not Low. | ||
| NTF ipduSlave04EmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.130 | WARNING: The Slave04 emd Humidity Too Low. | ||
| NTF ipduSlave04EmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.131 | INFORMATION: The Slave04 emd Alarm1 Normal. | ||
| NTF ipduSlave04EmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.132 | WARNING: The Slave04 emd Alarm1 Active. | ||
| NTF ipduSlave04EmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.133 | INFORMATION: The Slave04 emd Alarm2 Normal. | ||
| NTF ipduSlave04EmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.134 | WARNING: The Slave04 emd Alarm2 Active. | ||
| NTF ipduSlave04OutletCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.135 | WARNING: The Slave04 Outlet Current over threshold. | ||
| NTF ipduSlave05Inlet01OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.136 | CRITICAL: The Slave05 input01 voltage over high threshold. | ||
| NTF ipduSlave05Inlet01NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.137 | CRITICAL: The Slave05 input01 voltage Not over high threshold. | ||
| NTF ipduSlave05Inlet02OverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.138 | CRITICAL: The Slave05 input02 voltage over high threshold. | ||
| NTF ipduSlave05Inlet02NotOverHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.139 | CRITICAL: The Slave05 input02 voltage Not over high threshold. | ||
| NTF ipduSlave05Inlet01UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.140 | CRITICAL: The Slave05 input01 voltage under low threshold. | ||
| NTF ipduSlave05Inlet01NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.141 | CRITICAL: The Slave05 input01 voltage Not under low threshold. | ||
| NTF ipduSlave05Inlet02UnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.142 | CRITICAL: The Slave05 input02 voltage under low threshold. | ||
| NTF ipduSlave05Inlet02NotUnderLow | 1.3.6.1.4.1.4555.1.1.20.2.0.143 | CRITICAL: The Slave05 input02 voltage Not under low threshold. | ||
| NTF ipduSlave05Inlet01CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.144 | CRITICAL: The Slave05 input01 current over high threshold. | ||
| NTF ipduSlave05Inlet01NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.145 | CRITICAL: The Slave05 input01 current not over high threshold. | ||
| NTF ipduSlave05Inlet02CurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.146 | CRITICAL: The Slave05 input02 current over high threshold. | ||
| NTF ipduSlave05Inlet02NotCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.147 | CRITICAL: The Slave05 input02 current not over high threshold. | ||
| NTF ipduSlave05EmdTemperatureNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.148 | INFORMATION: The Slave05 emd Temperature Not High. | ||
| NTF ipduSlave05EmdTemperatureTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.149 | WARNING: The Slave05 emd Temperature Too High. | ||
| NTF ipduSlave05EmdTemperatureNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.150 | INFORMATION: The Slave05 emd Temperature Not Low. | ||
| NTF ipduSlave05EmdTemperatureTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.151 | WARNING: The Slave05 emd Temperature Too Low. | ||
| NTF ipduSlave05EmdHumidityNotHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.152 | INFORMATION: The Slave05 emd Humidity Not High. | ||
| NTF ipduSlave05EmdHumidityTooHigh | 1.3.6.1.4.1.4555.1.1.20.2.0.153 | WARNING: The Slave05 emd Humidity Too High. | ||
| NTF ipduSlave05EmdHumidityNotLow | 1.3.6.1.4.1.4555.1.1.20.2.0.154 | INFORMATION: The Slave05 emd Humidity Not Low. | ||
| NTF ipduSlave05EmdHumidityTooLow | 1.3.6.1.4.1.4555.1.1.20.2.0.155 | WARNING: The Slave05 emd Humidity Too Low. | ||
| NTF ipduSlave05EmdAlarm1Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.156 | INFORMATION: The Slave05 emd Alarm1 Normal. | ||
| NTF ipduSlave05EmdAlarm1Active | 1.3.6.1.4.1.4555.1.1.20.2.0.157 | WARNING: The Slave05 emd Alarm1 Active. | ||
| NTF ipduSlave05EmdAlarm2Normal | 1.3.6.1.4.1.4555.1.1.20.2.0.158 | INFORMATION: The Slave05 emd Alarm2 Normal. | ||
| NTF ipduSlave05EmdAlarm2Active | 1.3.6.1.4.1.4555.1.1.20.2.0.159 | WARNING: The Slave05 emd Alarm2 Active. | ||
| NTF ipduSlave05OutletCurrentOverTh | 1.3.6.1.4.1.4555.1.1.20.2.0.160 | WARNING: The Slave05 Outlet Current over threshold. |
RFC description
SOCOMEC Intelligent Power Management MIB for intelligent power distribution units (iPDU) monitoring and control.
Start monitoring Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.