inletConfigfrequencyLowAction
Module: SOCOMECUPS-MIB-v2
OID (symbolic): SOCOMECUPS-MIB-v2::inletConfigfrequencyLowAction
OID (numeric): 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Reaction of the device when inlet frequency lower than set point.
What is inletConfigfrequencyLowAction?
Selects what the device does when this inlet's frequency drops below the inletConfigFrequencyLow threshold, such as logging the event, sending a trap, or triggering a relay output, flagging unstable upstream generator or utility power.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12 snmpwalk -v2c -c public <target> SOCOMECUPS-MIB-v2::inletConfigfrequencyLowAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12.1 snmpget -v2c -c public <target> SOCOMECUPS-MIB-v2::inletConfigfrequencyLowAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12.1 i <value>
Start monitoring Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SOCOMECUPS-MIB-v2::inletConfigfrequencyLowAction OID value, configure state conditions and alerts, and monitor any Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4555 | socomec | SOCOMECPDU-MIB |
| 1.3.6.1.4.1.4555.1 | software | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1 | network | SOCOMECUPS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4555.1.1.20 | iPDU | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1 | ipduObjects | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3 | ipduDevice | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1 | ipduDeviceInlet | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2 | ipduDeviceInletConfigTable | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1 | ipduDeviceInletConfigEntry | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.12 | inletConfigfrequencyLowAction | SOCOMECUPS-MIB-v2 |