All MIBs › SOCOMECUPS-MIB-v2 › inletConfigVoltageHighAction
inletConfigVoltageHighAction
Module: SOCOMECUPS-MIB-v2
OID (symbolic): SOCOMECUPS-MIB-v2::inletConfigVoltageHighAction
OID (numeric): 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Reaction of the device when inlet voltage higher than set point.
What is inletConfigVoltageHighAction?
Selects what the device does when this inlet's voltage exceeds the inletConfigVoltageHigh threshold, such as logging the event, sending a trap, or triggering a relay output, so an admin is alerted to an overvoltage condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4 snmpwalk -v2c -c public <target> SOCOMECUPS-MIB-v2::inletConfigVoltageHighAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4.1 snmpget -v2c -c public <target> SOCOMECUPS-MIB-v2::inletConfigVoltageHighAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4.1 i <value>
Start monitoring Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SOCOMECUPS-MIB-v2::inletConfigVoltageHighAction OID value, configure state conditions and alerts, and monitor any Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4555 | socomec | SOCOMECPDU-MIB |
| 1.3.6.1.4.1.4555.1 | software | SOCOMECUPS-MIB |
| 1.3.6.1.4.1.4555.1.1 | network | SOCOMECUPS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4555.1.1.20 | iPDU | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1 | ipduObjects | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3 | ipduDevice | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1 | ipduDeviceInlet | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2 | ipduDeviceInletConfigTable | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1 | ipduDeviceInletConfigEntry | SOCOMECUPS-MIB-v2 |
| 1.3.6.1.4.1.4555.1.1.20.1.3.1.2.1.4 | inletConfigVoltageHighAction | SOCOMECUPS-MIB-v2 |