SOCOMECUPS-MIB-v2 :: slaveOutletLocation01

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SOCOMECUPS-MIB-v2 › slaveOutletLocation01

slaveOutletLocation01

Module: SOCOMECUPS-MIB-v2

OID (symbolic): SOCOMECUPS-MIB-v2::slaveOutletLocation01

OID (numeric): 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: A Description of a outlet name of device.

What is slaveOutletLocation01?

A writable free-text field (up to 31 characters) recording the physical location of the equipment plugged into outlet 1 on the slave PDU, e.g. 'Rack 7, Shelf 2'. The source MIB's own DESCRIPTION text calls this an outlet 'name', but its position in the LocationXX series and object name show it is really the location field paired with slaveOutletName01.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2
snmpwalk -v2c -c public <target> SOCOMECUPS-MIB-v2::slaveOutletLocation01

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2.1
snmpget -v2c -c public <target> SOCOMECUPS-MIB-v2::slaveOutletLocation01.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2.1 s <value>

Start monitoring Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SOCOMECUPS-MIB-v2::slaveOutletLocation01 OID value, configure state conditions and alerts, and monitor any Socomec Sicon UPS, Socomec PDU (identity/agent-firmware/NTP-sync status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4555socomecSOCOMECPDU-MIB
1.3.6.1.4.1.4555.1softwareSOCOMECUPS-MIB
1.3.6.1.4.1.4555.1.1networkSOCOMECUPS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4555.1.1.20iPDUSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1ipduObjectsSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4ipduSlaveSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4.3ipduSlaveOutletSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4.3.1ipduSlaveOutletConfigSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2ipduSlaveDeviceOutletLocationTableSOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1ipduSlaveDeviceOutletLocationEntrySOCOMECUPS-MIB-v2
1.3.6.1.4.1.4555.1.1.20.1.4.3.1.2.1.2slaveOutletLocation01SOCOMECUPS-MIB-v2