| OID symbolic | OID numeric | Type | Access | Description |
| sleMpls | 1.3.6.1.4.1.6296.101.16 | | | SLE MplsTp. |
| sleMplsTpLps | 1.3.6.1.4.1.6296.101.16.18 | | | This management information module supports the
configuration and management of MplsTp TP linear
protection groups. |
| sleMplsTpLpsCfg | 1.3.6.1.4.1.6296.101.16.18.1 | | | |
| sleMplsTpLpsCfgInfoTable | 1.3.6.1.4.1.6296.101.16.18.1.1 | | read-only | This table lists the sleMplsTp linear protection groups that
have been configured on the system. |
| sleMplsTpLpsCfgInfoEntry | 1.3.6.1.4.1.6296.101.16.18.1.1.1 | | read-only | A conceptual row in the sleMplsTpLpsCfgInfoTable. |
| U32 sleMplsTpLpsCfgInfoGroupIndex | 1.3.6.1.4.1.6296.101.16.18.1.1.1.1 | Unsigned32 | read-only | Index for the conceptual row identifying a protection group. |
| OCT sleMplsTpLpsCfgInfoGroupName | 1.3.6.1.4.1.6296.101.16.18.1.1.1.2 | OCTET STRING | read-only | Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. |
| INT sleMplsTpLpsCfgInfoMode | 1.3.6.1.4.1.6296.101.16.18.1.1.1.3 | INTEGER | read-only | The architectural mode of the Protection group. This can
either be 1+1, 1:1, 1:n.
1+1
In the 1+1 protection scheme, a fully dedicated
protection entity is allocated. Data traffic is copied
and fed at the source to both the working and the
protection entities. The traffic on the working and the
protection entities is transmitted simultaneously to
the sink of the protection domain, where selection
between the working and protection entities is performed
1:1
In the 1:1 scheme, a protection path is allocated to
protect against a defect, failure, or a degradation in a
working path. In normal conditions, data traffic is
transmitted over the working entity, while the
protection entity functions in the idle state. If there
is a defect on the working entity or a specific
administrative request, traffic is switched to the
protection entity.
1:n
In case of 1:n linear protection, one protection entity
is allocated to protect n working entities. The protection
entity might not have sufficient resources to protect all the
working entities that may be affected by fault conditions at a
specific time. In this case, in order to guaranteed
protection, the protection entity should support enough
capacity and bandwidth to protect any of the n working
entities. |
| INT sleMplsTpLpsCfgInfoProtectionScheme | 1.3.6.1.4.1.6296.101.16.18.1.1.1.4 | INTEGER | read-only | The object represents the operational scheme of
protection switching group. The protection scheme may
either be unidirectional or bidirectional.
bidirectional
In bidirectional protection scheme, both the directions
will be switched simultaneously even if the fault
applies to only one direction of the path.
unidirectional
In unidirectional protection scheme protection switching
will be performed independently for each direction of a
bidirectional transport path
This object may not be modified if the associated
sleMplsTpLpsCfgRowStatus object is equal to active(1). |
| INT sleMplsTpLpsCfgInfoRevertive | 1.3.6.1.4.1.6296.101.16.18.1.1.1.5 | INTEGER | read-only | This object represents the reversion mode of the Linear
Protection Switching group. The reversion mode of
protection mechanism may be either revertive or
non-revertive.
In non-revertive mode, after a service has been
recovered, traffic will be forwarded on the recovery
path revertive
In revertive mode, after a service has been
recovered, traffic will be redirected back onto the
original working path. |
| U32 sleMplsTpLpsCfgInfoWtr | 1.3.6.1.4.1.6296.101.16.18.1.1.1.6 | Unsigned32 | read-only | This object hold the Wait To Restore timer value in
seconds.
The WTR timer is used to delay reversion of PSC state
to Normal state when recovering from a failure
condition on the working path when the protection
domain is configured for revertive behavior
This object may not be modified if the associated
sleMplsTpLpsCfgRowStatus object is equal to active(1). |
| U32 sleMplsTpLpsCfgInfoContinualTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.1.1.7 | Unsigned32 | read-only | The Continual Tx Time in Seconds. Represents the time
interval to send the continual LPS packet to the other
end based on the current state. |
| U32 sleMplsTpLpsCfgInfoRapidTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.1.1.8 | Unsigned32 | read-only | The Rapid Tx interval in micro-Seconds. Represents the time
interval to send the LPS packet to the other end, when
there is a change in state of Linear Protection domain due
to local input. The default value is 3.3 milli-seconds
which is 3300 micro-seconds |
| INT sleMplsTpLpsCfgInfoSwitchOver | 1.3.6.1.4.1.6296.101.16.18.1.1.1.9 | INTEGER | read-only | this object used for switch the traffic to the back up path. |
| INT sleMplsTpLpsCfgInfoLockOut | 1.3.6.1.4.1.6296.101.16.18.1.1.1.10 | INTEGER | read-only | this is object is used for preventing the swith traffic by the protection path. |
| U32 sleMplsTpLpsCfgInfoHoldOffTimer | 1.3.6.1.4.1.6296.101.16.18.1.1.1.11 | Unsigned32 | read-only | this object used for show the hold off timer. |
| INT sleMplsTpLpsCfgInfoActivePath | 1.3.6.1.4.1.6296.101.16.18.1.1.1.12 | INTEGER | read-only | This object say which path is Active . |
| INT sleMplsTpLpsCfgInfoOperationState | 1.3.6.1.4.1.6296.101.16.18.1.1.1.13 | INTEGER | read-only | this object says Operational Status of LPS. The LPS is between PE to PE. |
| INT sleMplsTpLpsCfgInfoEventStatus | 1.3.6.1.4.1.6296.101.16.18.1.1.1.14 | INTEGER | read-only | This is object says EVENT Status of LPS protection . |
| sleMplsTpLpsCfgControl | 1.3.6.1.4.1.6296.101.16.18.1.2 | | | |
| INT sleMplsTpLpsCfgControlRequest | 1.3.6.1.4.1.6296.101.16.18.1.2.1 | INTEGER | read-write | the configuration commands, and user can configure functions
via setting this entry as proper value. |
| SLE sleMplsTpLpsCfgControlStatus | 1.3.6.1.4.1.6296.101.16.18.1.2.2 | SleControlStatusType | read-only | status of user command. User have to check this value as
.busy. or .idle. before do setRequest. |
| G32 sleMplsTpLpsCfgControlTimer | 1.3.6.1.4.1.6296.101.16.18.1.2.3 | Gauge32 | read-write | the wait-time until setRequest end. In case of short-time command, this value is 0 |
| TIK sleMplsTpLpsCfgControlTimeStamp | 1.3.6.1.4.1.6296.101.16.18.1.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| SLE sleMplsTpLpsCfgControlReqResult | 1.3.6.1.4.1.6296.101.16.18.1.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| OCT sleMplsTpLpsCfgControlGroupName | 1.3.6.1.4.1.6296.101.16.18.1.2.6 | OCTET STRING | read-write | Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. |
| INT sleMplsTpLpsCfgControlMode | 1.3.6.1.4.1.6296.101.16.18.1.2.7 | INTEGER | read-write | The architectural mode of the Protection group. This can
either be 1+1, 1:1, 1:n.
1+1
In the 1+1 protection scheme, a fully dedicated
protection entity is allocated. Data traffic is copied
and fed at the source to both the working and the
protection entities. The traffic on the working and the
protection entities is transmitted simultaneously to
the sink of the protection domain, where selection
between the working and protection entities is performed
1:1
In the 1:1 scheme, a protection path is allocated to
protect against a defect, failure, or a degradation in a
working path. In normal conditions, data traffic is
transmitted over the working entity, while the
protection entity functions in the idle state. If there
is a defect on the working entity or a specific
administrative request, traffic is switched to the
protection entity.
1:n
In case of 1:n linear protection, one protection entity
is allocated to protect n working entities. The protection
entity might not have sufficient resources to protect all the
working entities that may be affected by fault conditions at a
specific time. In this case, in order to guaranteed
protection, the protection entity should support enough
capacity and bandwidth to protect any of the n working
entities. |
| INT sleMplsTpLpsCfgControlProtectionScheme | 1.3.6.1.4.1.6296.101.16.18.1.2.8 | INTEGER | read-write | The object represents the operational scheme of
protection switching group. The protection scheme may
either be unidirectional or bidirectional.
bidirectional
In bidirectional protection scheme, both the directions
will be switched simultaneously even if the fault
applies to only one direction of the path.
unidirectional
In unidirectional protection scheme protection switching
will be performed independently for each direction of a
bidirectional transport path
This object may not be modified if the associated
sleMplsTpLpsCfgControlRowStatus object is equal to active(1). |
| INT sleMplsTpLpsCfgControlRevertive | 1.3.6.1.4.1.6296.101.16.18.1.2.9 | INTEGER | read-write | This object represents the reversion mode of the Linear
Protection Switching group. The reversion mode of
protection mechanism may be either revertive or
non-revertive.
nonrevertive
In non-revertive mode, after a service has been
recovered, traffic will be forwarded on the recovery
path
revertive
In revertive mode, after a service has been
recovered, traffic will be redirected back onto the
original working path. |
| U32 sleMplsTpLpsCfgControlWtr | 1.3.6.1.4.1.6296.101.16.18.1.2.10 | Unsigned32 | read-write | This object hold the Wait To Restore timer value in
seconds.
The WTR timer is used to delay reversion of PSC state
to Normal state when recovering from a failure
condition on the working path when the protection
domain is configured for revertive behavior
This object may not be modified if the associated
sleMplsTpLpsCfgControlRowStatus object is equal to active(1). |
| U32 sleMplsTpLpsCfgControlContinualTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.2.11 | Unsigned32 | read-write | The Continual Tx Time in Seconds. Represents the time
interval to send the continual LPS packet to the other
end based on the current state. |
| U32 sleMplsTpLpsCfgControlRapidTxInterval | 1.3.6.1.4.1.6296.101.16.18.1.2.12 | Unsigned32 | read-write | The Rapid Tx interval in micro-Seconds. Represents the time
interval to send the LPS packet to the other end, when
there is a change in state of Linear Protection domain due
to local input. The default value is 3.3 milli-seconds
which is 3300 micro-seconds |
| INT sleMplsTpLpsCfgControlswitchOver | 1.3.6.1.4.1.6296.101.16.18.1.2.13 | INTEGER | read-write | this object used for switch the traffic to the back up path. |
| INT sleMplsTpLpsCfgControlLockOut | 1.3.6.1.4.1.6296.101.16.18.1.2.14 | INTEGER | read-write | this is object is used for preventing the swith traffic by the protection path. |
| U32 sleMplsTpLpsCfgControlHoldOffTimer | 1.3.6.1.4.1.6296.101.16.18.1.2.15 | Unsigned32 | read-write | This object is used to set the holdofftimer |
| sleMplsTpLpsMeCfg | 1.3.6.1.4.1.6296.101.16.18.2 | | | |
| sleMplsTpLpsMeCfgInfoTable | 1.3.6.1.4.1.6296.101.16.18.2.1 | | not-accessible | This table lists Maintenance Association that have been
configured in Protection groups. |
| sleMplsTpLpsMeCfgInfoEntry | 1.3.6.1.4.1.6296.101.16.18.2.1.1 | | not-accessible | A conceptual row in the sleMplsTpLpsMeCfgInfoTable. |
| U32 sleMplsTpLpsMeCfgInfoMegIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.1 | Unsigned32 | not-accessible | Uniquely identifies a maintenance entity index within
a MEG. |
| U32 sleMplsTpLpsMeCfgInfoMeIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.2 | Unsigned32 | not-accessible | This object denotes the ME name, each
Maintenance Entity has unique name within MEG. |
| U32 sleMplsTpLpsMeCfgInfoMPId | 1.3.6.1.4.1.6296.101.16.18.2.1.1.3 | Unsigned32 | not-accessible | Indicates the maintenance point index, used to create
multiple MEPs in a node of single ME. The value of this
object can be MEP index or MIP index. Managers should
obtain new values for row creation in this table by reading
mplsOamIdMeMpIndexNext. |
| U32 sleMplsTpLspMeCfgInfoGroupIndex | 1.3.6.1.4.1.6296.101.16.18.2.1.1.4 | Unsigned32 | read-only | Textual name represents the sleMplsTp tp protection group.
Each Protection Group is identified by a unique
protection group name. |
| INT sleMplsTpLpsMeCfgInfoState | 1.3.6.1.4.1.6296.101.16.18.2.1.1.5 | INTEGER | read-write | This object represents the operational state of the ME
as either primary or backup |
| sleMplsTpLpsMeCfgControl | 1.3.6.1.4.1.6296.101.16.18.2.2 | | | |
| INT sleMplsTpLpsMeCfgControlRequest | 1.3.6.1.4.1.6296.101.16.18.2.2.1 | INTEGER | read-write | the configuration commands, and user can configure functions via setting
this entry as proper value. |
| SLE sleMplsTpLpsMeCfgControlStatus | 1.3.6.1.4.1.6296.101.16.18.2.2.2 | SleControlStatusType | read-only | status of user command. User have to check this value as
.busy. or .idle. before do setRequest. |
| G32 sleMplsTpLpsMeCfgControlTimer | 1.3.6.1.4.1.6296.101.16.18.2.2.3 | Gauge32 | read-write | the wait-time until setRequest end. In case of short-time command, this value is 0 |
| TIK sleMplsTpLpsMeCfgControlTimeStamp | 1.3.6.1.4.1.6296.101.16.18.2.2.4 | TimeTicks | read-only | the time stamp of the last command. (don.t care) |
| SLE sleMplsTpLpsMeCfgControlReqResult | 1.3.6.1.4.1.6296.101.16.18.2.2.5 | SleControlRequestResultType | read-only | Result of the last command. |
| OCT sleMplsTpLpsMeCfgControlMegName | 1.3.6.1.4.1.6296.101.16.18.2.2.6 | OCTET STRING | read-write | Uniquely identifies a maintenance entity index within
a MEG |
| OCT sleMplsTpLpsMeCfgControlMeName | 1.3.6.1.4.1.6296.101.16.18.2.2.7 | OCTET STRING | read-write | This object denotes the ME name, each
Maintenance Entity has unique name within MEG. |
| U32 sleMplsTpLpsMeCfgControlMpId | 1.3.6.1.4.1.6296.101.16.18.2.2.8 | Unsigned32 | read-write | |
| OCT sleMplsTpLpsMeCfgControlGroupName | 1.3.6.1.4.1.6296.101.16.18.2.2.9 | OCTET STRING | read-write | This object holds the Protection group index wherein
this ME included in. If this ME is not part of a protection
group this value is set to 0. |
| INT sleMplsTpLpsMeCfgControlState | 1.3.6.1.4.1.6296.101.16.18.2.2.10 | INTEGER | read-write | This object represents the operational state of the ME
as either primary or backup |