| OID symbolic | OID numeric | Type | Access | Description |
| buc1 | 1.3.6.1.4.1.23304.2.2.1 | | | |
| INT buc1Address | 1.3.6.1.4.1.23304.2.2.1.1.2.2 | INTEGER | read-write | Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected. |
| STR buc1BuildStandard | 1.3.6.1.4.1.23304.2.2.1.2.17 | DisplayString | read-only | Gets the BUC build standard.
**** No respond - message if buc1 not connected. |
| STR buc1BurstPwrThresh | 1.3.6.1.4.1.23304.2.2.1.1.5.3 | DisplayString | read-write | Sets/Gets burst power threshold.
**** No respond - message if buc1 not connected. |
| STR buc1Config | 1.3.6.1.4.1.23304.2.2.1.2.16 | DisplayString | read-only | Gets the BUC configuration.
**** No respond - message if buc1 not connected. |
| buc1Configuration | 1.3.6.1.4.1.23304.2.2.1.1 | | | |
| STR buc1DeviceType | 1.3.6.1.4.1.23304.2.2.1.2.10 | DisplayString | read-only | Gets the device type. Format is X,Y where X is the model and
Y is software version.
**** No respond - message if buc1 not connected. |
| INT buc1Faults | 1.3.6.1.4.1.23304.2.2.1.2.4 | INTEGER | read-only | Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault,
Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault
Bit6 LNB fault, Bit7 Red'cy Cont fault.
Respond -1 if buc2 not connected. |
| buc1Freqs | 1.3.6.1.4.1.23304.2.2.1.1.4 | | | |
| STR buc1Gateway | 1.3.6.1.4.1.23304.2.2.1.2.11 | DisplayString | read-only | Gets the BUC gateway address (Only for RBUC).
**** No respond - message if buc1 not connected. |
| STR buc1IdInfo | 1.3.6.1.4.1.23304.2.2.1.3.1 | DisplayString | read-only | Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown.
**** No respond - message if buc1 not connected. |
| INT buc1IFFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.2 | INTEGER | read-write | Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected. |
| buc1Info | 1.3.6.1.4.1.23304.2.2.1.3 | | | |
| STR buc1IpAddress | 1.3.6.1.4.1.23304.2.2.1.2.12 | DisplayString | read-only | Gets the BUC IP address (Only for RBUC).
**** No respond - message if buc1 not connected. |
| INT buc1LatchedFaults | 1.3.6.1.4.1.23304.2.2.1.2.5 | INTEGER | read-only | Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
| STR buc1LEDState | 1.3.6.1.4.1.23304.2.2.1.1.5.5 | DisplayString | read-write | Sets/Gets LEDs status on/off (Only for RBUC).
**** No respond - message if buc1 not connected. |
| STR buc1Limits | 1.3.6.1.4.1.23304.2.2.1.3.2 | DisplayString | read-only | Gets the limit data for the BUC. Format is:
Power meter MIN/MAX , IF,RF and LO frequencies.
This string will have a zero length if the revision is unknown.
**** No respond - message if buc1 not connected. |
| INT buc1LOFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.3 | INTEGER | read-write | Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected. |
| STR buc1MACAddress | 1.3.6.1.4.1.23304.2.2.1.2.13 | DisplayString | read-only | Gets the BUC MAC address (Only for RBUC).
**** No respond - message if buc1 not connected. |
| STR buc1MinMaxTemperature | 1.3.6.1.4.1.23304.2.2.1.2.7 | DisplayString | read-only | Gets the BUC temperature. Format is x.x,y.y where x.x is max
and y.y is min temperature.
**** No respond - message if buc1 not connected. |
| buc1Misc | 1.3.6.1.4.1.23304.2.2.1.1.5 | | | |
| INT buc1Mode | 1.3.6.1.4.1.23304.2.2.1.1.3.1 | INTEGER | read-write | Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected. |
| STR buc1Netmask | 1.3.6.1.4.1.23304.2.2.1.2.14 | DisplayString | read-only | Gets the BUC netmask (Only for RBUC).
**** No respond - message if buc1 not connected. |
| T/F buc1OnLine | 1.3.6.1.4.1.23304.2.2.1.1.3.2 | TruthValue | read-write | Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected. |
| INT buc1PaStatus | 1.3.6.1.4.1.23304.2.2.1.2.1 | INTEGER | read-only | Gets to 1 when PA is on. Respond -1 if buc1 not connected. |
| buc1PktProtocol | 1.3.6.1.4.1.23304.2.2.1.1.2 | | | |
| STR buc1PktProtocolsInfo | 1.3.6.1.4.1.23304.2.2.1.3.3 | DisplayString | read-only | Gets supported packet protocols and the corresponding address ranges.
**** No respond - message if buc1 not connected. |
| INT buc1Protocol | 1.3.6.1.4.1.23304.2.2.1.1.2.1 | INTEGER | read-write | Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected. |
| STR buc1PwrAlarmThresh | 1.3.6.1.4.1.23304.2.2.1.1.5.2 | DisplayString | read-write | Sets/Gets power alarm threshold.
**** No respond - message if buc1 not connected. |
| buc1RCSetting | 1.3.6.1.4.1.23304.2.2.1.1.3 | | | |
| STR buc1RefPower | 1.3.6.1.4.1.23304.2.2.1.2.15 | DisplayString | read-only | Gets the BUC reference power.
**** No respond - message if buc1 not connected. |
| STR buc1RefSource | 1.3.6.1.4.1.23304.2.2.1.1.5.4 | DisplayString | read-write | Sets/Gets reference source 0-external, 1-internal (Only for RBUC).
**** No respond - message if buc1 not connected. |
| INT buc1RFFreq | 1.3.6.1.4.1.23304.2.2.1.1.4.1 | INTEGER | read-write | Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected. |
| STR buc1SerIf | 1.3.6.1.4.1.23304.2.2.1.1.5.1 | DisplayString | read-write | Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.
**** No respond - message if buc1 not connected. |
| buc1Status | 1.3.6.1.4.1.23304.2.2.1.2 | | | |
| INT buc1SystemPoll | 1.3.6.1.4.1.23304.2.2.1.2.9 | INTEGER | read-only | Gets the system poll status. Format is
Bit0 - Fault, Bit1 - System change.
Respond -1 if buc1 not connected. |
| INT buc1SystemSetting | 1.3.6.1.4.1.23304.2.2.1.2.8 | INTEGER | read-only | Gets the current system status. Format is
Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx
Bit4 - Redundancy mode, Bit5 - Online,
Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx,
Bit10 - SNMP Tx.
Respond -1 if buc1 not connected. |
| STR buc1Temperature | 1.3.6.1.4.1.23304.2.2.1.2.6 | DisplayString | read-only | Gets the BUC temperature. Format is x.x.
**** No respond - message if buc1 not connected. |
| INT buc1TxAttenuator | 1.3.6.1.4.1.23304.2.2.1.1.1.3 | INTEGER | read-write | Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected. |
| STR buc1TxBurstPower | 1.3.6.1.4.1.23304.2.2.1.2.3 | DisplayString | read-only | Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst
power, y.y is min and z.z is max burts power.
**** No respond - message if buc1 not connected. |
| INT buc1TxDefault | 1.3.6.1.4.1.23304.2.2.1.1.1.2 | INTEGER | read-write | Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected. |
| INT buc1TxOn | 1.3.6.1.4.1.23304.2.2.1.1.1.1 | INTEGER | read-write | Sets Tx on/off. Respond -1 if buc1 not connected. |
| STR buc1TxPower | 1.3.6.1.4.1.23304.2.2.1.2.2 | DisplayString | read-only | Gets Tx power format x.x dB.
**** No respond - message if buc1 not connected. |
| buc1TxSettings | 1.3.6.1.4.1.23304.2.2.1.1.1 | | | |
| buc2 | 1.3.6.1.4.1.23304.2.2.2 | | | |
| INT buc2Address | 1.3.6.1.4.1.23304.2.2.2.1.2.2 | INTEGER | read-write | Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected. |
| STR buc2BuildStandard | 1.3.6.1.4.1.23304.2.2.2.2.17 | DisplayString | read-only | Gets the BUC build standard.
**** No respond - message if buc2 not connected. |
| STR buc2BurstPwrThresh | 1.3.6.1.4.1.23304.2.2.2.1.5.3 | DisplayString | read-write | Sets/Gets burst power threshold.
**** No respond - message if buc2 not connected. |
| STR buc2Config | 1.3.6.1.4.1.23304.2.2.2.2.16 | DisplayString | read-only | Gets the BUC configuration.
**** No respond - message if buc2 not connected. |
| buc2Configuration | 1.3.6.1.4.1.23304.2.2.2.1 | | | |
| STR buc2DeviceType | 1.3.6.1.4.1.23304.2.2.2.2.10 | DisplayString | read-only | Gets the device type. Format is X,Y where X is the model and
Y is software version.
**** No respond - message if buc2 not connected. |
| INT buc2Faults | 1.3.6.1.4.1.23304.2.2.2.2.4 | INTEGER | read-only | Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault,
Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault
Bit6 LNB fault, Bit7 Red'cy Cont fault.
Respond -1 if buc2 not connected. |
| buc2Freqs | 1.3.6.1.4.1.23304.2.2.2.1.4 | | | |
| STR buc2Gateway | 1.3.6.1.4.1.23304.2.2.2.2.11 | DisplayString | read-only | Gets the BUC gateway address (Only for RBUC).
**** No respond - message if buc2 not connected. |
| STR buc2IdInfo | 1.3.6.1.4.1.23304.2.2.2.3.1 | DisplayString | read-only | Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown.
**** No respond - message if buc2 not connected. |
| INT buc2IFFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.2 | INTEGER | read-write | Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected. |
| buc2Info | 1.3.6.1.4.1.23304.2.2.2.3 | | | |
| STR buc2IpAddress | 1.3.6.1.4.1.23304.2.2.2.2.12 | DisplayString | read-only | Gets the BUC IP address (Only for RBUC).
**** No respond - message if buc2 not connected. |
| INT buc2LatchedFaults | 1.3.6.1.4.1.23304.2.2.2.2.5 | INTEGER | read-only | Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected. |
| STR buc2LEDState | 1.3.6.1.4.1.23304.2.2.2.1.5.5 | DisplayString | read-write | Sets/Gets LEDs status on/off (Only for RBUC).
**** No respond - message if buc2 not connected. |
| STR buc2Limits | 1.3.6.1.4.1.23304.2.2.2.3.2 | DisplayString | read-only | Gets the limit data for the BUC. Format is:
Power meter MIN/MAX , IF,RF and LO frequencies.
This string will have a zero length if the revision is unknown.
**** No respond - message if buc2 not connected. |
| INT buc2LOFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.3 | INTEGER | read-write | Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected. |
| STR buc2MACAddress | 1.3.6.1.4.1.23304.2.2.2.2.13 | DisplayString | read-only | Gets the BUC MAC address (Only for RBUC).
**** No respond - message if buc2 not connected. |
| STR buc2MinMaxTemperature | 1.3.6.1.4.1.23304.2.2.2.2.7 | DisplayString | read-only | Gets the BUC temperature. Format is x.x,y.y where x.x is max
and y.y is min temperature.
**** No respond - message if buc2 not connected. |
| buc2Misc | 1.3.6.1.4.1.23304.2.2.2.1.5 | | | |
| INT buc2Mode | 1.3.6.1.4.1.23304.2.2.2.1.3.1 | INTEGER | read-write | Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected. |
| STR buc2Netmask | 1.3.6.1.4.1.23304.2.2.2.2.14 | DisplayString | read-only | Gets the BUC netmask (Only for RBUC).
**** No respond - message if buc2 not connected. |
| T/F buc2OnLine | 1.3.6.1.4.1.23304.2.2.2.1.3.2 | TruthValue | read-write | Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected. |
| INT buc2PaStatus | 1.3.6.1.4.1.23304.2.2.2.2.1 | INTEGER | read-only | Gets to 1 when PA is on. Respond -1 if buc2 not connected. |
| buc2PktProtocol | 1.3.6.1.4.1.23304.2.2.2.1.2 | | | |
| STR buc2PktProtocolsInfo | 1.3.6.1.4.1.23304.2.2.2.3.3 | DisplayString | read-only | Gets supported packet protocols and the corresponding address ranges.
**** No respond - message if buc2 not connected. |
| INT buc2Protocol | 1.3.6.1.4.1.23304.2.2.2.1.2.1 | INTEGER | read-write | Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected. |
| STR buc2PwrAlarmThresh | 1.3.6.1.4.1.23304.2.2.2.1.5.2 | DisplayString | read-write | Sets/Gets power alarm threshold.
**** No respond - message if buc2 not connected. |
| buc2RCSetting | 1.3.6.1.4.1.23304.2.2.2.1.3 | | | |
| STR buc2RefPower | 1.3.6.1.4.1.23304.2.2.2.2.15 | DisplayString | read-only | Gets the BUC reference power.
**** No respond - message if buc2 not connected. |
| STR buc2RefSource | 1.3.6.1.4.1.23304.2.2.2.1.5.4 | DisplayString | read-write | Sets/Gets reference source 0-external, 1-internal (Only for RBUC).
**** No respond - message if buc2 not connected. |
| INT buc2RFFreq | 1.3.6.1.4.1.23304.2.2.2.1.4.1 | INTEGER | read-write | Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected. |
| STR buc2SerIf | 1.3.6.1.4.1.23304.2.2.2.1.5.1 | DisplayString | read-write | Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.
**** No respond - message if buc2 not connected. |
| buc2Status | 1.3.6.1.4.1.23304.2.2.2.2 | | | |
| INT buc2SystemPoll | 1.3.6.1.4.1.23304.2.2.2.2.9 | INTEGER | read-only | Gets the system poll status. Format is
Bit0 - Fault, Bit1 - System change.
Respond -1 if buc2 not connected. |
| INT buc2SystemSetting | 1.3.6.1.4.1.23304.2.2.2.2.8 | INTEGER | read-only | Gets the current system status. Format is
Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx
Bit4 - Redundancy mode, Bit5 - Online,
Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx,
Bit10 - SNMP Tx.
Respond -1 if buc2 not connected. |
| STR buc2Temperature | 1.3.6.1.4.1.23304.2.2.2.2.6 | DisplayString | read-only | Gets the BUC temperature. Format is x.x.
**** No respond - message if buc2 not connected. |
| INT buc2TxAttenuator | 1.3.6.1.4.1.23304.2.2.2.1.1.3 | INTEGER | read-write | Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected. |
| STR buc2TxBurstPower | 1.3.6.1.4.1.23304.2.2.2.2.3 | DisplayString | read-only | Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst
power, y.y is min and z.z is max burts power.
**** No respond - message if buc2 not connected. |
| INT buc2TxDefault | 1.3.6.1.4.1.23304.2.2.2.1.1.2 | INTEGER | read-write | Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected. |
| INT buc2TxOn | 1.3.6.1.4.1.23304.2.2.2.1.1.1 | INTEGER | read-write | Sets Tx on/off. Respond -1 if buc2 not connected. |
| STR buc2TxPower | 1.3.6.1.4.1.23304.2.2.2.2.2 | DisplayString | read-only | Gets Tx power format x.x dB.
**** No respond - message if buc2 not connected. |
| buc2TxSettings | 1.3.6.1.4.1.23304.2.2.2.1.1 | | | |
| ctrl | 1.3.6.1.4.1.23304.2.2.3 | | | |
| INT faults | 1.3.6.1.4.1.23304.2.2.3.2.3 | INTEGER | read-only | Gets the current fault status. |
| STR gateway | 1.3.6.1.4.1.23304.2.2.3.1.14 | DisplayString | read-only | Gets the 7586 gateway address. |
| STR idInfo | 1.3.6.1.4.1.23304.2.2.3.3.1 | DisplayString | read-only | Gets the module firmware revision, serial number and model. This string
will have a zero length if the revision is unknown. |
| info | 1.3.6.1.4.1.23304.2.2.3.3 | | | |
| STR ipAddr | 1.3.6.1.4.1.23304.2.2.3.1.11 | DisplayString | read-only | Gets the 7586 IP address. |
| INT ledState | 1.3.6.1.4.1.23304.2.2.3.1.6 | INTEGER | read-write | Sets 7586 LED. |
| STR lnbCurrent | 1.3.6.1.4.1.23304.2.2.3.2.1 | DisplayString | read-only | Sets 7586 LNB current. |
| STR lnbCurrentLimit | 1.3.6.1.4.1.23304.2.2.3.1.5 | DisplayString | read-write | Sets LNB current limits. |
| STR lnbVoltage | 1.3.6.1.4.1.23304.2.2.3.2.2 | DisplayString | read-only | Sets 7586 LNB voltage. |
| STR macAddress | 1.3.6.1.4.1.23304.2.2.3.1.12 | DisplayString | read-only | Gets the 7586 MAC address. |
| STR netmask | 1.3.6.1.4.1.23304.2.2.3.1.13 | DisplayString | read-only | Gets the 7586 netmask. |
| INT onlineStream | 1.3.6.1.4.1.23304.2.2.3.1.2 | INTEGER | read-write | Sets the online stream. |
| INT operationalMode | 1.3.6.1.4.1.23304.2.2.3.1.1 | INTEGER | read-write | Sets 7586 operational mode - Auto, Manual Stream1, Stream2. |
| rc7586MIB | 1.3.6.1.4.1.23304.2.2 | | | The Structure of Management Information for the
Codan enterprise.
Copyright(c) 2009 All rights reserved |
| STR refPwr | 1.3.6.1.4.1.23304.2.2.3.1.10 | DisplayString | read-only | Gets 7586 reference power. |
| INT refSource | 1.3.6.1.4.1.23304.2.2.3.1.7 | INTEGER | read-write | Sets 7586 reference state. |
| STR refThresh | 1.3.6.1.4.1.23304.2.2.3.1.9 | DisplayString | read-write | Sets 7586 reference alarm treshold. |
| STR refTrim | 1.3.6.1.4.1.23304.2.2.3.1.8 | DisplayString | read-write | Sets 7586 reference trim. |
| settings | 1.3.6.1.4.1.23304.2.2.3.1 | | | |
| INT startupTime | 1.3.6.1.4.1.23304.2.2.3.1.4 | INTEGER | read-write | Sets Startup time. |
| status | 1.3.6.1.4.1.23304.2.2.3.2 | | | |
| INT waveguideSwitch | 1.3.6.1.4.1.23304.2.2.3.1.3 | INTEGER | read-write | Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only. |